首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 828 毫秒
1.
A simple Cu-DNAzyme system is used for signal transduction of a CuO nanoparticle-labeled immunoassay, which makes the immunoassay fast, simple, cost-effective, and sensitive, thus promising for biomedical applications and point-of-care testing.  相似文献   

2.
Zhou F  Wang M  Yuan L  Cheng Z  Wu Z  Chen H 《The Analyst》2012,137(8):1779-1784
The availability of techniques for the sensitive detection of early stage cancer is crucial for patient survival. Our previous research (Langmuir, 2011, 27, 2155-2158) showed that gold nanoparticle layers (GNPL) used in indirect format ELISA amplified the signal, and gave a lower limit of detection (LOD) compared with commercial ELISA plates. However, due to its intrinsic limitations, indirect ELISA is not suitable for samples of complex composition, such as serum, plasma, etc., thus limiting the clinical performance of this kind of ELISA. In the work reported here, a GNPL-based sandwich format ELISA was developed, which showed superiority in terms of detection limit and sensitivity in the determination of rabbit IgG in buffer. More importantly, experiments using plasma spiked with carcinoembryonic antigen (CEA) as a representative biomarker showed that our GNPL-based ELISA assay amplified the signal and lowered the LOD compared to other assays, including commercialized CEA ELISA kits. This simple and cost-effective GNPL-based sandwich ELISA holds promise in clinical applications.  相似文献   

3.
Journal of Solid State Electrochemistry - In this paper, a simple and feasible immunoassay protocol with signal amplification for sensitive determination of alpha fetoprotein (AFP, used as a model)...  相似文献   

4.
We report on a novel immunoassay for porcine pseudorabies virus (PRV) antibody that is based on fluorescence signal amplification induced by silver(I) ion exchange in CdSe nanocrystals. An antigen-antibody-secondary antibody sandwich structure was first formed from PRV, PRV antibody, and CdSe-labeled rabbit anti-pig antibody. Then, the Cd(II) ions in the CdSe labels were released by a cation exchange reaction with Ag(I). Released Cd(II) was finally quantified using the sensitive fluorescent probe Rhodamine 5 N. Due to this signal amplification, the sensitivity and linear range of the immunoassay were largely improved (compared to the traditional ELISA) in having a limit of detection as low as 1.2 ng?mL?1 of PRV antibody and a linear range from 2.44 to 312 ng?mL?1. The successful determination of PRV antibody in pig serum samples is proof for the utility of the method.
Figure
A simple, rapid and sensitive method for the detection of PRV antibody through the fluorescence signal amplification caused by cation-exchange in CdSe NCs was reported. The CdSe NCs labeled rabbit anti-pig IgG was used to capture the PRV antibody. After the immunoreaction, the Cd2+ in the CdSe labels was completely replaced by the cation-exchange reaction with Ag+. Then Cd2+sensitive fluorescence indicator Rhod-5 N was added to bind with Cd2+ and caused the fluorescence signal enhance substantially. Thus a novel method for rapid and sensitive detection of porcine pseudorabies based on the fluorescence signal amplification was developed.  相似文献   

5.
We present a simple device for multiplex quantitative enzyme-linked immunosorbant assays (ELISA) made from a novel melt-extruded microcapillary film (MCF) containing a parallel array of 200 μm capillaries along its length. To make ELISA devices different protein antigens or antibodies were immobilised inside individual microcapillaries within long reels of MCF extruded from fluorinated ethylene propylene (FEP). Short pieces of coated film were cut and interfaced with a pipette, allowing sequential uptake of samples and detection solutions into all capillaries from a reagent well. As well as being simple to produce, these FEP MCF devices have excellent light transmittance allowing direct optical interrogation of the capillaries for simple signal quantification. Proof of concept experiments demonstrate both quantitative and multiplex assays in FEP MCF devices using a standard direct ELISA procedure and read using a flatbed scanner. This new multiplex immunoassay platform should find applications ranging from lab detection to point-of-care and field diagnostics.  相似文献   

6.
Shen GY  Wang H  Deng T  Shen GL  Yu RQ 《Talanta》2005,67(1):217-220
A simple, rapid, and highly sensitive immunosensor for the direct determination of carcinoembryonic antigen (CEA) in human serum using a piezoelectric crystal has been developed and optimized. In order to improve sensitivity of the immunosensor, a protein A-based orientation-controlled immobilization method for antibodies was adopted together with an immunoreactive accelerant of polyethyleneglycol (PEG) used to amplify the signal response of frequency. Human normal serum was utilized as a reference background. The linear range for CEA concentration obtained by the end-point method was 66.7-466.7 ng/mL. Clinical samples from cancer patients were analyzed by the proposed piezoelectric immunoassay, and the analytical results were reasonably comparable with those obtained by the chemiluminescence immunoassay (CLIA). The proposed immunosensor provides a new promising method for the highly sensitive immunoassay of CEA in clinical laboratory.  相似文献   

7.
发展了一种基于Nation膜修饰电极构制的无分离步骤的异相免疫分析法,羊抗人IgM抗血清和邻氨基酚通过Nation膜固定在电极表面,形成生物敏感膜。采用竞争吸附免疫分析法,以HRP—IgM作标记物,只有结合在生物敏感膜的酶标物才能催化邻氨基酚与H2O2的反应,产生电分析信号,从而与游离在溶液里的酶标物区分开。因此分析过程勿需洗脱步骤,简化了分析过程,在优化的条件下,对IgM的检测范围为0.07~1.8mg/L。该分析技术操作简单、分析速度快。  相似文献   

8.
Boosting the detection sensitivity of enzyme-linked immunosorbent assay (ELISA) is significant to the early clinical diagnosis of various diseases. Here, we developed a versatile immunosensor using silica nanospheres as carriers for sensitive detection of porcine circovirus type 2 (PCV2) antibody. With HRP enzyme covalently immobilized on the silica nanospheres and CdSe nanocrystals embedded inside, these signal probes were successfully utilized in the sensitive detection of PCV2 antibody by ELISA, fluorometry and square-wave voltammetry (SWV). To further demonstrate the performance of the immunosensor, Human IgG (HIgG) was used as a model analyte. Since more HRP and CdSe QDs were loaded, 5-, 200- and 400-fold enhancements in amplified ELISA, fluorometry and voltammetry responses for HIgG could be achieved compared to conventional ELISA. The respective detection limits of theses methods for HIgG were 3.9, 0.1 and 0.05 ng mL−1 with a RSD below 5% for amplified ELISA, fluorescence and SWV measurements. Additionally, a 100-fold improvement was obtained in the detection sensitivity for PCV2 antibody immunoassay. The versatile immunosensor exhibits good sensitivity, stability and reproducibility, suggesting its potential applications in clinical diagnostics.  相似文献   

9.
Dichlobenil is an extensively used herbicide worldwide which is transformed to the mobile 2,6-dichlorobenzamide (BAM) in soil. BAM has been found in many European groundwater resources that are exploited for drinking water. Currently, immunoassay based monitoring technique (plate based ELISA) is being employed to quantitatively detect BAM in water samples. In this work, as a starting step of developing immunoassay based on-site monitoring systems for pesticide analysis, the heterogeneous BAM immunoassay is optimised in terms of surface (polymer) regeneration. We have synthesised a small library of BAM haptens which are slightly different in chemical structures, immobilised them on surfaces and compared the affinity constants of the monoclonal antibody HYB 273 towards them. By using ELISA technology, we also have checked the regeneration potentials of the haptens, correlated these results to the affinity constants and found that BAM hapten with an intermediate affinity has better regeneration potential.  相似文献   

10.
Herein, we demonstrate that a very familiar, yet underutilized, physical parameter—gas pressure—can serve as signal readout for highly sensitive bioanalysis. Integration of a catalyzed gas‐generation reaction with a molecular recognition component leads to significant pressure changes, which can be measured with high sensitivity using a low‐cost and portable pressure meter. This new signaling strategy opens up a new way for simple, portable, yet highly sensitive biomedical analysis in a variety of settings.  相似文献   

11.
Herein, we demonstrate that a very familiar, yet underutilized, physical parameter—gas pressure—can serve as signal readout for highly sensitive bioanalysis. Integration of a catalyzed gas‐generation reaction with a molecular recognition component leads to significant pressure changes, which can be measured with high sensitivity using a low‐cost and portable pressure meter. This new signaling strategy opens up a new way for simple, portable, yet highly sensitive biomedical analysis in a variety of settings.  相似文献   

12.
A highly sensitive electrochemical immunosensor for avian influenza A (H7N9) virus (H7N9 AIV) detection was proposed by using electrochemical magnetoimmunoassay coupled with biometallization and anodic stripping voltammetry. This strategy could accumulate the enzyme‐generated product on the surface of the magneto electrode by means of silver deposition, which amplified the detection signal about 80 times. The use of magnetic beads (MBs) and the magneto electrode could also amplify the detection signal. Furthermore, a bi‐electrode signal transduction system was introduced into this immunosensor, which is also beneficial to the immunoassay. A concentration as low as 0.011 ng mL?1 of H7N9 AIV could be detected in about 1.5 h with good specificity. This study not only provides a simple and sensitive approach for virus detection but also offers an effective signal enhancement strategy for the development of highly sensitive MB‐based electrochemical immunoassays.  相似文献   

13.
In this study, we described a pH ELISA using synthetic melanin nanoparticles (SMNPs) for the co-immobilization of glucose oxidase and second antibody as signal labels, portable pH meter as signal readout device for detecting biomarker of myocardial injury. This assay is easy-to-use, portable, sensitive and able to realize point-of-care testing (POCT), which was demonstrated the signifi cant promising in the early diagnosis and screening of acute myocardial infarction.  相似文献   

14.
Cowles CL  Zhu X  Publicover NG 《The Analyst》2011,136(14):2975-2980
In this work, a fluorescence signal transduction mechanism based on cation release from ZnS nanocrystals was developed for sandwich immunoassay. In this mechanism, ZnS nanocrystals as labels in immunoassay are dissolved by acid to release zinc ions. After pH adjustment of the dissolving solution using a basic solution, zinc-ion sensitive fluorescence indicator Fluozin-3 is added to bind with the released zinc ions for sensitive fluorescence measurement. Using mouse IgG as a model analyte, the immunoassay adopting this signal transduction mechanism demonstrates a low detection limit around 1 pM and a detection range with two orders of magnitude (1 pM to 0.5 nM).  相似文献   

15.
Constructing a recombinant protein between a reporter enzyme and a detector protein to produce a homogeneous immunological reagent is advantageous over random chemical conjugation. However, the approach hardly recombines multiple enzymes in a difunctional fusion protein, which results in insufficient amplification of the enzymatic signal, thereby limiting its application in further enhancement of analytical signal. In this study, two site-specific biotinylated recombinant proteins, namely, divalent biotinylated alkaline phosphatase (AP) and monovalent biotinylated ZZ domain, were produced by employing the Avitag–BirA system. Through the high streptavidin (SA)–biotin interaction, the divalent biotinylated APs were clustered in the SA–biotin complex and then incorporated with the biotinylated ZZ. This incorporation results in the formation of a functional macromolecule that involves numerous APs, thereby enhancing the enzymatic signal, and in the production of several ZZ molecules for the interaction with immunoglobulin G (IgG) antibody. The advantage of this signal amplification strategy is demonstrated through ELISA, in which the analytical signal was substantially enhanced, with a 32-fold increase in the detection sensitivity compared with the ZZ–AP fusion protein approach. The proposed immunoassay without chemical modification can be an alternative strategy to enhance the analytical signals in various applications involving immunosensors and diagnostic chips, given that the label-free IgG antibody is suitable for the ZZ protein.  相似文献   

16.
Alpha-methylacyl-CoA racemase (AMACR) is over-expressed in many cancer types and can serve as a novel diagnostic biomarker. Development of convenient and sensitive detection methods of AMACR is of particular importance for cancer diagnosis. Aptamers are a type of recognition elements, which possess many advantages over antibody, making them suitable for applications in biosensing and biotechnology. In this work, we use the efficient surface modification of gold nanoparticles (AuNPs) to prepare the horseradish peroxidase (HRP) and aptamer dual-functionalized nanoprobe. The immobilization of HRP and thiol-terminated aptamer on the surface of AuNPs can be achieved through electrostatic interaction and the formation of Au–S bond, respectively. This nanoprobe, which is used as discriminating and catalytic probe, can be combined with enzyme immunoassay method to increase the detection sensitivity of AMACR. The detection limit can reach as low as 4.6 pg mL−1 due to the dual signal amplification from enzymatic cycling and the high loading of enzymes on AuNPs. This sensitivity is about three orders of magnitude higher than that of AMACR aptamer based fluorescence method, which is also comparable to or one order of magnitude higher than that of ELISA. Furthermore, this method is more simple and effective, which not only avoids the conjugation between recognition element and the catalytic enzyme, but also achieves greater signal amplification. This assay could be used as a sensitive and selective platform for the detection of target protein.  相似文献   

17.
To determine sulphamethazine (SMZ) residues in edible animal foods (pig muscle, chicken muscle, egg, fish, milk and liver), a competitive direct enzyme-linked immunosorbent assay (ELISA) and a colloidal gold immunoassay were established. The limits of detection of the ELISA and the colloidal gold immunoassay were 0.02 and 0.5 μg kg−1, respectively. The specificity of the ELISA developed to the SMZ was high according to the results of cross-reactivity testing with 14 kinds of sulphonamides. To obtain a more sensitive immunoassay, buffer solution (30 mmol L−1 phosphate-buffered saline with 0.05% Tween 20, pH 8.5) was optimized through the whole test procedure. A simple and efficient extraction method for the rapid detection of SMZ residues in foods was developed, with recoveries between 74 and 117.5%. Matrix effects can be avoided by 1:10 dilution of pig muscle, chicken muscle, egg, fish, milk and liver with optimal buffer. The detection limit of SMZ was 5 μg kg−1 in liver and 2 μg kg−1 in the other five samples. For the validation of the ELISA tests, sample extracts were analysed by ELISA and high-performance liquid chromatography. The results obtained by these two methods showed a good correlation (r 2) which was greater than 0.9. The colloidal gold immunoassay presented in this assay was successfully applied to determine SMZ in pig muscle, milk and fish below or equal to the maximum residue level (20 μg kg−1).  相似文献   

18.
Cucumber mosaic virus (CMV) causes major losses to agricultural and horticultural crops around the world. Hence, a rapid assay for the detection of CMV which can be employed in both laboratory and field is essential. A portable electrochemical immunosensor system for the detection of CMV, based on immobilized CMV specific antibodies conjugated with gold nanoparticle was developed for this purpose. The conjugated antibodies were added with polymer and deposited onto carbon screen printed working electrodes. Optimization of the modified surface immunosensor was performed using sandwich immunoassay format (ELISA). The initial ELISA result for the standard curve development showed a limit of detection down to 0.1mg/mL. Subsequently, the immunosensor was tested for cross reactivity with other plant pathogens. The performance of the electrochemical immunosensor revealed that it has a high selectivity in sample matrix with other organism. This immunosensor provides a promising technology for simple and sensitive detection system that is essential in rapid detection of plant pathogens.  相似文献   

19.
A rapid immunoassay for sensitive detection of microcystin-LR using a portable chemiluminescence multichannel immunosensor (CL-MADAG) was developed. The sensor device is based on a capillary ELISA technique in combination with a miniaturized fluidics system and uses chemiluminescence as the detection principle. Minimum concentrations of at least 0.2 μg L−1 microcystin-LR could be unambiguously measured in a spiked buffer system as well as in spiked real water samples. A single sample analysis for detection of microcystin-LR could be accomplished in just 13 min on the CL-MADAG. Besides providing a highly reproducible, fast and easy to perform test format, one major advantage of the newly established capillary immunoassay is represented by the feasibility of an internal retrospective quality control mechanism. Finally, simultaneous CL-MADAG measurements employing our inhibition immunoassay and a sandwich ELISA could be successfully demonstrated.  相似文献   

20.
The present study described a novel fluorescence enzyme-linked immunosorbent assay (ELISA) used to detect ochratoxin A (OTA) by using the glucose oxidase (GOx)-mediated fluorescence quenching of mercaptopropionic acid-capped CdTe quantum dots (MPA-QDs), in which GOx was used as an alternative to horseradish peroxidase (HRP) for the oxidization of glucose into hydrogen peroxide (H2O2) and gluconic acid. The MPA-QDs were used as a fluorescent signal output, whose fluorescence variation was extremely sensitive to the presence of H2O2 or hydrogen ions in the solution. Under the optimized conditions, the proposed fluorescence ELISA demonstrated a good linear detection of OTA in corn extract from 2.4 pg mL−1 to 625 pg mL−1 with a limit of detection of 2.2 pg mL−1, which was approximately 15-fold lower than that of conventional HRP-based ELISA. Our developed fluorescence immunoassay was also similar to HRP-based ELISA in terms of selectivity, accuracy, and reproducibility. In summary, this study was the first to use the GOx-mediated fluorescence quenching of QDs in immunoassay to detect OTA, offering a new possibility for the analysis of other mycotoxins and biomolecules.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号