首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In recent years, comprehensive two-dimensional gas chromatography (GC x GC) has attained increasing attention for its outstanding separation potential and capability to solve demanding analytical tasks. Trace level analysis of pesticides residues in complex food matrices represents such a demanding task. For some commodities, such as baby food, the requirements on method detection limits are very strict and the unambiguous confirmation of the pesticide presence based on mass spectrometric detection is required. In this work, GC x GC coupled to time-of-flight mass spectrometry (TOF MS) has been evaluated for the determination of pesticides residues in fruit samples. Twenty modern pesticides with a broad range of physico-chemical properties were analysed in apple and peach samples. It has been demonstrated that the application of comprehensive two-dimensional gas chromatography brings distinct advantages such as enhanced separation of target pesticides from matrix co-extracts as well as their improved detectability. The limits of detection of the pesticides comprised in the study (determined at S/N = 5) ranged from 0.2 to 30 pg, injected with the exception of the last eluted deltamethrin, for which 100 pg could be detected. When compared to one-dimentional GC-TOF MS analysis under essentially the same conditions the detectability enhancement was 1.5-50-fold. Full mass spectral information by time-of-flight mass spectrometry and the deconvolution capability of the dedicated software allowed for reliable identification of most pesticides at levels below 0.01 mg/kg (< 10 pg injected) in fruit. Performance characteristics of the GC x GC-TOF MS method, such as linearity of calibration curves, repeatability of (summed) peak areas, as well as repeatability of first and second dimension retention times, were shown to fully satisfy the requirements for trace level analysis of the pesticide residues in food.  相似文献   

2.
The present research is focused on the development of a comprehensive two-dimensional gas chromatography–rapid scanning quadrupole mass spectrometric (GC x GC-qMS) methodology for the analysis of trace-amount pesticides contained in a complex real-world sample. Reliable peak assignment was carried out by using a recently developed, dedicated pesticide MS library (for comprehensive GC analysis), characterized by a twin-filter search procedure, the first based on a minimum degree of spectral similarity and the second on the interactive use of linear retention indices (LRI). The library was constructed by subjecting mixtures of commonly used pesticides to GC x GC-qMS analysis and then deriving their pure mass spectra and LRI values. In order to verify the effectiveness of the approach, a pesticide-contaminated red grapefruit extract was analysed. The certainty of peak assignment was attained by exploiting both the enhanced separation power of dual-oven GC x GC and the highly effective search procedure.  相似文献   

3.
The potential of gas chromatography‐time‐of‐flight mass spectrometry (GC‐TOF MS) for screening anthropogenic organic contaminants in human breast adipose tissues has been investigated. Initially a target screening was performed for a list of 125 compounds which included persistent halogen pollutants [organochlorine (OC) pesticides, polychlorinated biphenylss (PCBs), polybrominated diphenyl ethers (PBDEs)], polyaromatic hydrocarbons (PAHs), alkylphenols, and a notable number of pesticides from the different fungicide, herbicide and insecticide families. Searching for target pollutants was done by evaluating the presence of up to five representative ions for every analyte, all measured at accurate mass (20‐mDa mass window). The experimental ion abundance ratios were then compared to those of reference standards for confirmation. Sample treatment consisted of an extraction with hexane and subsequent normal‐phase (NP) High performance liquid chromatography (HPLC) or SPE cleanup. The fat‐free LC fractions were then investigated by GC‐TOF MS. Full‐spectral acquisition and accurate mass data generated by GC‐TOF MS also allowed the investigation of nontarget compounds using appropriate processing software to manage MS data. Identification was initially based on library fit using commercial nominal mass libraries. This was followed by comparing the experimental accurate masses of the most relevant ions with the theoretical exact masses with calculations made using the elemental composition calculator included in the software. The application of both target and nontarget approaches to around 40 real samples allowed the detection and confirmation of several target pollutants including p,p′‐DDE, hexachlorobenzene (HCB), and some polychlorinated biphenyls (PCBs) and polyaromatic hydrocarbons (PAHs). Several nontarget compounds that could be considered anthropogenic pollutants were also detected. These included 3,5‐di‐tert‐butyl‐4‐hydroxy‐toluene (BHT) and its metabolite 3,5‐di‐tert‐butyl‐4‐hydroxybenzaldehyde (BHT‐CHO), dibenzylamine, N‐butyl benzenesulfonamide (N‐BBSA), some naphthalene‐related compounds and several PCBs isomers not included in the target list. As some of the compounds detected are xenoestrogens, the methodology developed in this paper could be useful in human breast cancer research. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

4.
Comprehensive two-dimensional gas chromatography (GC x GC) with fast acquisition time-of-flight (TOF) mass spectrometry (MS) was used to analyze a tobacco extract for pesticides. The emphasis was on qualitative characterization of the sample, using automated peak find and spectral deconvolution software to identify 14 pesticides in the extract. Two additional pesticides were located based on manual review of the data. Matrix-matched standards of tobacco extract spiked with 2.5 to 50 ng/mL concentrations of numerous organochlorine and organophosphorus pesticides were used to demonstrate linearity and the GC x GC benefit of eliminating interferences that might contribute to quantification bias.  相似文献   

5.
Accurate mass measurement (used to determine elemental formulae) is an essential tool for impurity identification in pharmaceutical development for process understanding. Accurate mass liquid chromatography/mass spectrometry (LC/MS) is used widely for these types of analyses; however, there are still many occasions when gas chromatography (GC)/MS is the appropriate technique. Therefore, the provision of robust technology to provide accurate mass GC/MS (and GC/MS/MS) for this type of activity is essential. In this report we describe the optimisation and application of a newly available atmospheric pressure chemical ionisation (APCI) interface to couple GC to time‐of‐flight (TOF) MS. To fully test the potential of the new interface the APCI source conditions were optimised, using a number of standard compounds, with a variety of structures, as used in synthesis at AstraZeneca. These compounds were subsequently analysed by GC/APCI‐TOF MS. This study was carried out to evaluate the range of compounds that are amenable to analysis using this technique. The range of compounds that can be detected and characterised using the technique was found to be extremely broad and include apolar hydrocarbons such as toluene. Both protonated molecules ([M + H]+) and radical cations (M+.) were observed in the mass spectra produced by APCI, along with additional ion signals such as [M + H + O]+. The technique has been successfully applied to the identification of impurities in reaction mixtures from organic synthesis in process development. A typical mass accuracy of 1–2 mm/zunits (m/z 80–500) was achieved allowing the reaction impurities to be identified based on their elemental formulae. These results clearly demonstrate the potential of the technique as a tool for problem solving and process understanding in pharmaceutical development. The reaction mixtures were also analysed by GC/electron ionisation (EI)‐MS and GC/chemical ionisation (CI)‐MS to understand the capability of GC/APCI‐MS relative to these two firmly established techniques. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

6.
建立了全二维气相色谱-飞行时间质谱(GC×GC-TOF MS)分析卷烟主流烟气中中性化学成分的方法。以较长的弱极性柱HP-5MS(50 m×0.2 mm i.d.×0.33μm)作为第一维柱,较短的薄液膜中等极性柱DB-17MS(1.7 m×0.1 mm i.d.×0.1μm)作为第二维柱,对优质烟叶单料卷烟烟气的中性成分进行定性分析,经过人工纠错等分析初步鉴定出匹配度大于700的1 464种成分,重点讨论了中性香味羰基化合物全二维点阵的谱图特征,为烟气和复杂体系的深入研究提供了方法学基础。  相似文献   

7.
A gas chromatographic/mass spectrometric (GS/MS) method was developed for the multiple determination of pesticides in sediment. The investigated pesticides included 85 compounds, i.e., 13 fungicides, 43 herbicides, and 29 insecticides. The pesticides were extracted from sediment samples by an ultrasonically assisted procedure. The extract was cleaned up by using reversed-phase column chromatography followed by normal-phase column chromatography. A styrene-divinylbenzene copolymer cartridge and a silica gel cartridge were used as the reversed-phase column and the normal-phase column, respectively. The compounds were determined by GC/MS with 2 internal standard compounds. The overall recoveries were 70-105%, and the relative standard deviations ranged from 1.5 to 18%. The minimum detectable concentrations were 2-10 microg/kg. This method was successfully applied to sediment samples from the Shin River in Niigata, Japan. Twenty-five pesticides (6 fungicides, 11 herbicides, and 8 insecticides) were detected in the sediment samples. The concentrations of the detected pesticides ranged from 3 to 69 microg/kg. Herbicides were found May through July; insecticides and fungicides were found July through August, and during July through September, respectively. The presence of pesticides in the river sediment was correlated with the time of pesticide application in the Shin River basin.  相似文献   

8.
Five different mass spectrometers interfaced to GC or LC were evaluated for their application to targeted and nontargeted screening of pesticides in two foods, spinach and ginseng. The five MS systems were capillary GC/MS/MS, GC-high resolution time-of-flight (GC/HR-TOF)-MS, TOF-MS interfaced with a comprehensive multidimensional GC (GCxGC/TOF-MS), an MS/MS ion trap hybrid mass (qTrap) system interfaced with an ultra-performance liquid chromatograph (UPLC-qTrap), and UPLC interfaced to an orbital trap high resolution mass spectrometer (UPLC/Orbitrap HR-MS). Each MS system was tested with spinach and ginseng extracts prepared through a modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) procedure. Each matrix was fortified at 10 and 50 ng/g for spinach or 25 and 100 ng/g for ginseng with subsets of 486 pesticides, isomers, and metabolites representing most pesticide classes. HR-TOF-MS was effective in a targeted search for characteristic accurate mass ions and identified 97% of 170 pesticides in ginseng at 25 ng/g. A targeted screen of either ginseng or spinach found 94-95% of pesticides fortified for analysis at 10 ng/g with GC/MS/MS or LC/MS/MS using multiple reaction monitoring (MRM) procedures. Orbitrap-MS successfully found 89% of 177 fortified pesticides in spinach at 25 ng/g using a targeted search of accurate mass pseudomolecular ions in the positive electrospray ionization mode. A comprehensive GCxGC/TOF-MS system provided separation and identification of 342 pesticides and metabolites in a single 32 min acquisition with standards. Only 67 or 81% of the pesticides were identified in ginseng and spinach matrixes at 25 ng/g or 10 ng/g, respectively. MS/MS or qTrap-MS operated in the MRM mode produced the lowest false-negative rates, at 10 ng/g. Improvements to instrumentation, methods, and software are needed for efficient use of nontargeted screens in parallel with triple quadrupole MS.  相似文献   

9.
A rapid screening method for pesticides has been developed to promote more efficient processing of produce entering the United States. Foam swabs were used to recover a multiclass mixture of 132 pesticides from the surfaces of grapes, apples, and oranges. The swabs were analyzed using direct analysis in real time (DART) ionization coupled with a high‐resolution Exactive Orbitrap? mass spectrometer. By using a DART helium temperature gradient from 100–350°C over 3 min, a minimal separation of analytes based on volatility differences was achieved. This, combined with the Exactive's mass resolution of 100 000, allowed the chromatographic step, along with the typical compositing and extraction steps associated with gas chromatography/mass spectrometry (GC/MS) or liquid chromatography/mass spectrometry (LC/MS) approaches, to be eliminated. Detection of 86% of the analytes present was consistently achieved at levels of 2 ng/g (per each apple or orange) and 10 ng/g (per grape). A resolution study was conducted with four pairs of isobaric compounds analyzed at a mass resolution of 100 000. Baseline separation was achieved with analyte ions differing in mass by 25 ppm and analyte ions with a mass difference of 10 ppm were partially resolved. In addition, field samples that had undergone traditional sample preparation using QuEChERS (quick, easy, cheap, rugged, and safe) were analyzed using both LC/MS and DART‐MS and the results from the two techniques were found to be comparable in terms of identification of the pesticides present. The use of swabs greatly increased sample throughput by reducing sample preparation and analysis time. Published in 2010 by John Wiley & Sons, Ltd.  相似文献   

10.
A procedure for identification of malting barley varieties using matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS) of ethanol‐soluble barley proteins (hordeins) is described. The hordeins were first extracted from milled barley grains by several extraction protocols (using different extraction agents and conditions). Hordein extracts were then analyzed directly via MALDI‐TOF MS without any preliminary purification or separation step, and the protein profiles of analyzed hordein extracts were compared in order to find out the most suitable extraction procedure for mass spectrometric analysis. The optimized procedure was successfully applied to identification of 13 malting barley varieties. Our results revealed that the proposed mass spectrometry‐based approach provides characteristic mass patterns of extracted hordeins, which can be advantageously used for barley variety identification. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
12.
The suitability of gas chromatography with pulsed flame-photometric detection (GC–PFPD) for determination of 24 organophosphorus (OP) pesticides in vegetables has been assessed. Pesticides were extracted with dichloromethane and analyzed without cleanup. The performance of the method was fit for purpose; recovery was between 73 and 110% and precision was better than 15%. Calculated lower limits of detection were typically <0.01 mg kg?1, much lower than the maximum residue levels stipulated by European legislation. Three pesticides were detected in vegetable samples. Their presence was confirmed by GC with tandem mass spectrometric detection (GC–MS–MS).  相似文献   

13.
This work presents a strategy for elucidation of unknown migrants from plastic food contact materials (baby bottles) using a combination of analytical techniques in an untargeted approach. First, gas chromatography (GC) coupled to mass spectrometry (MS) in electron ionisation mode was used to identify migrants through spectral library matching. When no acceptable match was obtained, a second analysis by GC‐(electron ionisation) high resolution mass spectrometry time of flight (TOF) was applied to obtain accurate mass fragmentation spectra and isotopic patterns. Databases were then searched to find a possible elemental composition for the unknown compounds. Finally, a GC hybrid quadrupole‐TOF‐MS with an atmospheric pressure chemical ionisation source was used to obtain the molecular ion or the protonated molecule. Accurate mass data also provided additional information on the fragmentation behaviour as two acquisition functions with different collision energies were available (MSE approach). In the low‐energy function, limited fragmentation took place, whereas for the high‐energy function, fragmentation was enhanced. For less volatile unknowns, ultra‐high pressure liquid chromatography‐quadrupole‐TOF‐MS was additionally applied. Using a home‐made database containing common migrating compounds and plastic additives, tentative identification was made for several positive findings based on accurate mass of the (de)protonated molecule, product ion fragments and characteristic isotopic ions. Six illustrative examples are shown to demonstrate the modus operandi and the difficulties encountered during identification. The combination of these techniques was proven to be a powerful tool for the elucidation of unknown migrating compounds from plastic baby bottles. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

14.
Two different toxicity tests, an electrochemical biosensor Cellsense and a bioluminescence inhibition assay ToxAlert were performed in order to establish and compare the acute toxicity responses of different types of raw and spiked water for a selected group of pesticides. The selected compounds were endosulfan, chlorfenvinphos, dimethoate, fenamiphos, ametryn, deltamethrin and alpha-cypermethrin; all of them are used in large quantities for agricultural purposes. In the first step, the study of the toxicity responses for each individual pesticide with Milli-Q water was carried out. Next, the toxic responses of different mixtures of these pesticides in different water matrices, i.e., Milli-Q water, surface water, groundwater and wastewater were studied in order to evaluate (i) device advantages and limitations for the toxicity evaluation of real environmental samples, (ii) antagonistic or synergistic effects and (iii) the influence of the water matrices. The survey of pesticides in real samples was carried out using a combined method involving both chemical analysis and toxicity bioassays. Chemical analysis involved the use of solid-phase micro-extraction (SPME) followed by gas chromatography with electron capture detection (GC/ECD) or thermoionic specific detection (GC/TSD) with mass spectrometric confirmation (GC/MS).  相似文献   

15.
GC–MS optimization method including both advantages from chromatographic separation and mass spectrometric detection was designed for a set of 93 volatile organic compounds. Only a few experiments were necessary to determine the thermodynamic retention parameters for all compounds on a RTX-VMS column. From these data, computer simulation was used in order to predict the retention times of the compounds in temperature programmed gas chromatography. Then, an automatic selection of ions from the NIST database was performed and compared to the optimum conditions (full separation of VOC). This simulation-selection procedure was used to screen a numerous set of GC and MS conditions in order to quickly design a GC–MS method whatever the set of compounds considered.  相似文献   

16.
The direct qualification and quantification of the volatile components of Teucrium chamaedrys was studied using a direct thermal desorption (DTD) technique with comprehensive two-dimensional (2D) gas chromatography-time-of-flight mass spectrometry (GC x GC-TOF/MS). The GC x GC separation chromatographically resolved hundreds of components within this sample, and with the separation coupled with TOF/MS for detection, high probability identifications were made for 68 compounds. The quantitative results were determined through the use of internal standards and the desorption of differing amounts of raw material in the injector. The highest yield of volatile compounds (0.39%, w/w) was obtained at 150 degrees C thermal desorption temperature using 1.0mg of dried sample placed in a glass injector liner when studied over the range 1.0-7.0mg. Lowest yield of 0.33% (w/w) was found for the largest sample size of 7.0mg. Relative standard deviation (RSD) for 10 replicates at each size sample were in the range 3.9-21.6%. The major compounds identified were beta-pinene, germacrene D, alpha-pinene, alpha-farnesene, alpha-gurjunene, gamma-elemene and gamma-cadinene. All identified compounds were quantified using total ion chromatogram (TIC) peak areas. DTD is a promising method for quantitative analysis of complex mixtures, and in particular for quantitative analysis of plant samples, which can yield data without the traditional obligation for costly and time-consuming extraction techniques.  相似文献   

17.
A comprehensive GCxGC-TOFMS method was optimized for multiresidue analysis of pesticides using a combination of a non-polar (RTX-5MS, 10 m x 0.18 mm x 0.2 microm) and a polar capillary column (TR-50MS, 1 m x 0.1 mm x 0.1 microm), connected in series through a dual stage thermal modulator. The method resolved the co-elution problems as observed in full scan one-dimensional GC-MS analysis and allowed chromatographic separation of 51 pesticides within 24 min run time with library-searchable mass spectrometric confirmation. Four pesticides, viz. chlorpyrifos-methyl, vinclozoline, parathion-methyl and heptachlor could be baseline separated on GCxGC, which were otherwise closely eluting and interfering each other's detection in 1D GC-MS run. Similarly, it could be possible to separate myclobutanil, buprofezin, flusilazole and oxyfluorfen on GCxGC. Although in 1D GC-MS, these closely eluting compounds could be identified through deconvolution algorithm and 'peak-find' option of the Chromatof software but the spectral purity significantly improved on GCxGC analysis. Thorough optimization was accomplished for the oven temperature programming, ion source temperature and GCxGC parameters like modulation period, duration of hot pulses, modulation-offset temperature, acquisition rate, etc. to achieve best possible separation of the test compounds. The limit of detection significantly improved by 2-12 times on GCxGC-TOFMS against GC-TOFMS because of sharper and narrower peak shapes. The method was tested for grape matrix after preparing the samples using previously described method and recoveries of the entire test pesticides were within 70-110% at 10 ng/g level of fortification. GCxGC-TOFMS was found to be an excellent technique for library-based screening of pesticides with high accuracy and sensitivity.  相似文献   

18.
Qiu Y  Lu X  Pang T  Ma C  Li X  Xu G 《Journal of separation science》2008,31(19):3451-3457
Comprehensive 2-D GC (GC x GC) coupled with TOF MS or flame ionization detector (FID) was employed to characterize and quantify the chemical composition of volatile oil in the radixes of Panax ginseng C. A. Mey. (ginseng) at different ages. Thirty-six terpenoids were tentatively identified based on the MS library search and retention index in a ginseng sample at the age of 3 years. An obvious group-type separation was obtained in the GC x GC-TOF MS chromatogram. The data collected by GC x GC-FID were processed using a principal component analysis (PCA) method to classify the samples at different ages. The compounds responsible for the significant differentiation among samples were defined. It was found that the relative abundances of alpha-cadinol, alpha-bisabolol, thujopsene, and n-hexadecanoic acid significantly rise with the increase in age.  相似文献   

19.
A rapid identification, classification and discrimination tool, using Fourier Transform Infrared (FTIR) spectroscopy combined with Principal Component Analysis (PCA), was developed and applied to determine the profile of the Supercritical Fluid Extraction (SFE) of Parkia speciosa seeds under various temperature and pressure conditions (313, 323, 333, 343, 353 and 363 K and 20.68, 27.58, 34.47, 41.37, 48.26, and 55.16 MPa). The separation and identification of the compounds was carried out by Gas Chromatography coupled with Time of Flight Mass Spectrometry (GC/TOF‐MS). This technique has made it possible to detect the variability obtained under different SFE conditions and the separation of different chemical compounds in P. speciosa seeds. The FTIR‐PCA results were verified by GC/TOF‐MS, and the FTIR‐PCA method successfully identified the unsaturated carboxylic acids with the highest percentage area under the different conditions.  相似文献   

20.
A method has been developed for the target analysis of over 100 pesticides and contaminants in a complex feed matrix. The method is based on extraction with ethyl acetate, cleanup by gel permeation chromatography (GPC) and dispersive solid-phase extraction (SPE) with primary secondary amine phase (PSA), and analysis by comprehensive two-dimensional gas chromatography with full scan time-of-flight mass spectrometric detection (GC x GC-TOF-MS). Parameters studied during method development included a dispersive SPE cleanup step after GPC, large volume injection into the GC system and the GC x GC separation. Qualitative and quantitative performance of the GC x GC system was evaluated by analyzing spiked extracts in the range equivalent to 1-100 microg/kg in feed. At levels of 50 microg/kg and higher, all compounds targeted for could be identified fully automatically by the software based on their mass spectra. At lower levels the hit rate decreased with the concentration. System linearity was excellent in solvent and only slightly affected by matrix (correlation coefficients r>or=0.995 for 90% of the compounds). Limits of quantification were in the 1-20 microg/kg range for most compounds. The overall method was validated for 106 compounds at the 10 and 100 microg/kg level. Recoveries between 70% and 110% and RSDs below 20% were obtained for the majority of the compounds.  相似文献   