首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This paper reports unusual on-column degradations of aniline compounds on Waters XBridge Shield RP18 column when ammonium hydroxide in water and acetonitrile were used as mobile phases in liquid chromatography. The change of the level of on-column degradation of a model compound (Compound 1) with time was observed in the first fifteen injections when started at 60 °C. During a subsequent cooling program from 60 °C to 10 °C with a 10 °C interval, the levels of the degradation products of Compound 1 changed with the change of temperature and reached a maximum at 40 °C. The on-column degradation of Compound 1 was observed when started at 10 °C in the first injection, however, the magnitude of the change of the level of on-column degradation of Compound 1 with time in the first fifteen injections was much smaller than that at 60 °C. During a subsequent heating program from 10 to 60 °C with a 10 °C interval, the levels of the degradation products of Compound 1 increased with the increase in temperature but without a maximum. The change of the degradation product levels of this model compound in the heating process is not super-imposable with that in the cooling process, which demonstrates the degree of the degradation also depends on the heating or cooling process. Column history studies demonstrated that the on-column degradation of Compound 1 changed dramatically on the used columns at both starting temperatures while the dependency of heating and cooling processes on on-column degradation still existed. The unusual on-column degradation of Compound 1 on the used columns can be regenerated in a very similar fashion with an acetic acid column-wash procedure, but is not identical to that on the new column. Similar degradations of other commercially available aniline compounds were also observed with this high pH aqueous mobile phase system.  相似文献   

2.
3.
The chiral resolution of some clinically used drugs namely metoprolol, teratolol, tolamolol, nebivolol (beta-adrenergic blockers), econazole, miconazole (anti-fungal agents), cromakalim (anti-hypertensive agent) and etodolac (anti-inflammatory agent) was achieved on cellulose tris (3,5-dichlorophenylcarbamate) chiral stationary phase. The mobile phase used was 2-propanol at 0.5 mL/min with detection at 220 nm. The separation factors (alpha) of these drugs ranged from 1.24 to 3.90 while the resolution factors were from 1.05 to 5.0. The chiral recognition mechanisms between the racemates and the chiral selector are discussed.  相似文献   

4.
Reversed-phase liquid chromatography (RPLC) is very widely used for the separation and characterization of proteins and peptides. A novel type of highly stable silica-based stationary phase has been developed for protein separations. A dense monolayer of dimethyl-(chloromethyl)phenylethyl)-chlorosilane (DM-CMPES) on the surface of silica is "hyper-crosslinked" with a polyfunctional aromatic crosslinker through Friedel-Crafts chemistry resulting in stationary phases with extraordinary stability in acidic media. Elemental analysis data confirm the high degree of cross-linking among the surface groups. The hyper-crosslinked phases are extremely stable under highly acidic mobile phase conditions even at a temperature as high as 150 degrees C. A wide-pore (300 A) material made in this way is used here to separate proteins by a reversed-phase mechanism and compared to a commercially available "sterically protected" C18 phase. For small molecules, including neutral and basic compounds, these crosslinked phases give comparable peak shape and efficiency to the commercial phase. Our results show that no pore blockage takes place as commonly afflicts polymer coated phases. In consequence, protein separations on the new phases are acceptable. Using strong ion-pairing reagents, such as HPF6, improves the separation efficiency. Compared to the commercial phases, these new phases can be used at lower pHs and much higher temperatures thereby enabling much faster separations which is the primary focus of this work. Better efficiency for proteins was obtained at high temperature. However, at conventional linear velocities the instability of proteins at high temperature becomes a problem which establishes an upper temperature limit. Uses of a narrowbore column and high flow rates both solves this problem by reducing the time that proteins spend on the hot column and, of course, speeds up the separation of the protein mixture. Finally, an ultrafast gradient (<1 min) protein separation was obtained by utilizing the high temperature and thus high linear velocities afforded by the extreme stability of these new phases. The phases are stable even after 50h of exposure to 0.1% TFA at 120 degrees C. This paper is dedicated to the memory of Csaba Horvath whose work in high temperature HPLC inspired the development of the stationary phases described here.  相似文献   

5.
6.
Summary Specific side-on-fixed liquid-crystalline polymers (SOLCP) have been synthesized for use in silica-modified stationary phases in high-performance liquid chromatography (HPLC). The mesogenic side group of the SOLCP is composed of three benzoate-type phenyl rings with terminal alkoxy chains and is laterally linked to a polysiloxane backbone via an alkyl ester spacer arm. The dependence of the logarithm of the retention factor on the reciprocal temperature showed that the liquid-crystalline anisotropic order was conserved in the small pores (200 ? diameter) of the silica gel. The first-order nematic-isotropic transition is lost and probably becomes second-order. Adsorption enthalpies for the liquid-crystalline stationary phases have been measurement for three polycyclic aromatic hydrocarbon isomers (ortho-terphenyl, triphenylene, and chrysene) and compared with those for a commercial C18 phase. The adsorption enthalpies never exceeded 30 kJ mol−1, i.e. ten times the thermal agitation energy,RT. They were always less on the SOLCP stationary phase than on the C18 column, emphasizing the more rigid structure of the liquid crystalline phase and its mechanism based upon adsorption. Better separation of steroids, pesticides and amino acids were obtained with the LCP-coated silica than the commercial bonded C18 column. Four small peptides were successfully separated by using pure water as mobile phase.  相似文献   

7.
2-(2,3-anthracenedicarboximido)cyclohexane derivatives (AC) have been known as the evolutionary diastereomerizing reagents for enantiomer discrimination in HPLC with ODS. However, a substantial separation of diastereomers can be observed only at lower temperatures, such as -40 degrees C. Therefore, in this work, poly(octadecyl acrylate)-grafted silica, ODAn was applied as an alternative stationary phase to ODS for the separation of AC-derived diastereomers. As a result, complete separation was achieved even under the conventional condition: for example, methanol as the mobile phase and 0 degrees C as the column temperature. An investigation on the temperature dependency of the selectivity demonstrated that ODAn shows a remarkable increase in selectivity at temperatures below 30 degrees C, which almost agreed with the peak-top temperature of the endothermic peak in a DSC thermogram for ODA35 immersed in a mobile phase. The better separation would be derived from a highly ordered structure of ODAn and a carbonyl-pi interaction with AC-derived diastereomers.  相似文献   

8.
A butylimidazolium bromide surface-confined ionic liquid stationary phase was synthesized in-house. The synthesized phase was investigated for the separation of five peptides (Gly-Tyr, Val-Tyr-Val, leucine enkephalin, methionine enkephalin, and angiotensin-II). The peptides were successfully separated in less than 5 min. The effect of trifluoroacetic acid (TFA) on the separation of peptides was evaluated with results confirming that TFA was not acting as ion-pairing agent in separation of peptides on this phase.  相似文献   

9.
Summary L-N-(3,5-dimethoxyoxybenzoyl)isoleucine, ionically bonded to γ-aminopropyl silica, has been tested as a chiral stationary phase for the separation of racemates by HPLC. The phase shows good selectivity towards different types of racemates and in particular for those having an electron-poor aromatic group in their molecule. The separation of benzoin racemate can be achieved on the developed chiral phase with an α value of 1.10.  相似文献   

10.
J. Köhler 《Chromatographia》1986,21(10):573-582
Summary Poly(vinylpyrrolidone) (PVP) is immobilized on both, small- and large-pore silicas by thermal treatment, γ-radiation, or peroxide initiated polymerization. The hydrolytic stability of such a highly polar stationary phase significantly exceeds that of a comparable phase prepared by the chemical reaction of silica with a pyrrolidone ethyl dimethylchlorosilane silanization reagent. The properties of the different PVP-silicas are evaluated by elemental analysis, spectroscopy, and chromatography. Columns of PVP-silica packings can be used in several modes: a) under normal-phase conditions as a polar bonded stationary phase, b) under reversed-phase conditions, for the separation of organic proton-donor and hydrogen-bonding compounds, c) for the aqueous size exclusion chromatography of proteins, and d) with salt gradients for the hydrophobic interaction chromatography of proteins. The minimum observable reduced plate-height of PVP-silica columns is about 3. Double-layer polymer coating experiments using PVP-silica covered with poly(methyloctadecylsiloxane) have been performed to study diffusion and shielding effects of different polymer layers in the stationary phase. Depending on separation conditions, one or the other polymer governs the retention process. A mixed selectivity was observed in a reversed phase mode with acidic eluents.  相似文献   

11.
12.
A sensitive enantioselective high-performance liquid chromatography (HPLC) method was developed and validated to determine S-(+)- and R-(-)-arotinolol in human plasma. Baseline resolution was achieved by using teicoplanin macrocyclic antibiotic chiral stationary phase (CSP) known as Chirobiotic T with a polar organic mobile phase consisting of methanol:glacial acetic acid:triethylamine, 100:0.1:0.1, (v/v/v) at a fl ow rate of 0.8 mL/min and UV detection set at 317 nm. Human plasma was spiked with stock solution of arotinolol enantiomers and labetalol as the internal standard. The assay involved the use of liquid-liquid extraction procedure with ethyl ether under alkaline condition for human plasma sample prior to HPLC analysis. Recoveries for S-(+)- and R-(-)-arotinolol enantiomers were in the range 93-103% at 200-1400 ng/mL level. Intra-day and inter-day precision calculated as %RSD was in the ranges 1.3-3.4 and 1.9-4.5% for both enantiomers, respectively. Intra-day and inter-day accuracies calculated as percentage error were in the ranges 1.2-3.5 and 1.5-6.2% for both enantiomers, respectively. Linear calibration curves in the concentration range 100-1500 ng/mL for each enantiomer showed a correlation coefficient (r) of 0.9998. The limit of quantitation (LOQ) and limit of detection (LOD) for each enantiomer in human plasma were 100 and 50 ng/mL (S/N = 3), respectively.  相似文献   

13.
The enantiomers of fourteen O,O-dialkyl-2-benzyloxycarbonyl-aminoarylmethyl-phosphonates are directly separated on the tris(3,5-dimethylphenylcarbamate) cellulose column (Chiralcel OD-R) under reversed phase mode. The results of the chiral separation are different from the results obtained in the normal phase mode. The mobile phase plays an essential role in chiral discrimination when using Chiralcel OD-R. The influences of the mobile phase composition on the retention and the enantioselectivity are investigated. The influences on chiral separation of the length and steric hindrance of alkoxy groups of the phosphonate ester and of the nature of the substituent on the benzene ring that is attached to the chiral carbon atom are also discussed.  相似文献   

14.
Summary A method for simultaneous determination of Cr(III) and Cr(VI), using sodium diethyldithiocarbamate as chelating agent is given. At room temperature and pH 5.8 sodium diethyldithiocarbamate reacts with both Cr(III) and Cr(VI). Examination of this reaction by reversed phase high-performance liquid chromatography, makes it possible to correct for the interference between Cr(III) and Cr(VI) when determining the amount of Cr(III) present in the solution.  相似文献   

15.
We studied the quantification of an intact therapeutic monoclonal antibody (mAb), rituximab (RTX), using (reverse-phase) high-performance liquid chromatography with diode array detection ((RP)HPLC/DAD). To this end, we developed a chromatographic method and validated it as stability-indicating in accordance with the International Conference on Harmonization guidelines (ICH). A 300-Å C8 column (250 mm?×?4.6 mm, 5 μm) was used to perform the analysis, and the temperature was maintained at 70 °C. Although only one mAb was analyzed, it was necessary to apply a gradient to elute it with a complex organic mixture. Chromatograms were registered at several wavelengths, with λ?=?214 nm employed for quantification purposes. The method was developed to quantify marketed RTX under typical hospital administration conditions. Further dilution was avoided in order to prevent additional mAb modification, and in this way the method was shown to be linear from 60 to 5000 mg/L. The precision of the method (repeatability and intermediate precision, estimated as the relative standard deviation, RSD %), was less than 1.0 %. Accuracy, specificity, robustness, and system suitability were also evaluated as specified in the ICH guidelines. We conducted a comprehensive chromatographic analysis by submitting RTX to several informative stress conditions. These forced degradation studies were conducted for two reasons: to estimate the specificity of the method, and to evaluate the robustness of the mAb formulation against external stress factors when handling it in preparation for administration. Thus, we investigated the effects of acid, base, oxidation, ionic strength, temperature, and UV light. Although a slight modification to the intact mAb could not be distinguished chromatographically in the stress studies we conducted, the procedure proposed here to evaluate peak purity enabled us to detect it with a satisfactory level of confidence. The proposed method could therefore be considered stability-indicating for quantyfying the intact mAb since it is qualified to detect its degradation/modification. Finally, the method was used to evaluate RTX in a long-term stability study performed under hospital conditions of use.  相似文献   

16.
Summary A method for the simultaneous determination of Cr(III) and Cr(VI) in water samples is described. The different reaction products of Cr(III) and Cr(VI) species with ammonium pyrrolidinedithiocarbamate (APDC) are extracted with ethyl acetate and determined by reversed phase HPLC using UV-detection. The procedure is optimized and its detection limit accordingly improved as compared to literature data. The detection limits achieved are 2.4 g/l for Cr(III) and 2.1 g/l for Cr(VI) and the calibration curves are linear between 5 g/l and 5000 g/l. For the speciation of Cr, APDC was demonstrated to be more suitable as chelating agent than sodium diethyldithiocarbamate (NaDDC). The procedure was applied to the determination of both Cr species in galvanic waste waters and its accuracy was approved by comparing the results (at the 100 g/l level) with those of a photometric determination of Cr(VI) species.Dedicated to Professor Dr. Wilhelm Fresenius on the occasion of his 80th birthday  相似文献   

17.
18.
A previously reported chromatographic method to determine the 1-octanol/water partition coefficient (log P(o/w)) of organic compounds is used to estimate the hydrophobicity of bases, mainly commercial drugs with diverse chemical nature and pK(a) values higher than 9. For that reason, mobile phases buffered at high pH to avoid the ionization of the solutes and three different columns (Phenomenex Gemini NX, Waters XTerra RP-18 and Waters XTerra MS C(18)) with appropriate alkaline-resistant stationary phases have been used. Non-ionizable substances studied in previous works were also included in the set of compounds to evaluate the consistency of the method. The results showed that all the columns provide good estimations of the log P(o/w) for most of the compounds included in this study. The Gemini NX column has been selected to calculate log P(o/w) values of the set of studied drugs, and really good correlations between the determined log P(o/w) values and those considered as reference were obtained, proving the ability of the procedure for the lipophilicity assessment of bioactive compounds with very different structures and functionalities.  相似文献   

19.
Plots of the retention factor against mobile phase composition were used to organize a varied group of solutes into three categories according to their retention mechanism on an octadecylsiloxane-bonded silica stationary phase HyPURITY C18 with methanol-water and acetonitrile-water mobile phase compositions containing 10-70% (v/v) organic solvent. The solutes in category 1 could be fit to a general retention model, Eq. (2), and exhibited normal retention behavior for the full composition range. The solutes in category 2 exhibited normal retention behavior at high organic solvent composition with a discontinuity at low organic solvent compositions. The solutes in category 3 exhibited a pronounced step or plateau in the middle region of the retention plots with a retention mechanism similar to category 1 solutes at mobile phase compositions after the discontinuity and a different retention mechanism before the discontinuity. Selecting solutes and appropriate composition ranges from the three categories where a single retention mechanism was operative allowed modeling of the experimental retention factors using the solvation parameter model. These models were then used to predict retention factors for solutes not included in the models. The overwhelming number of residual values [log k (experimental) - log k (model predicted)] were negative and could be explained by contributions from steric repulsion, defined as the inability of the solute to insert itself fully into the stationary phase because of its bulkiness (i.e., volume and/or shape). Steric repulsion is shown to strongly depend on the mobile phase composition and was more significant for mobile phases with a low volume fraction of organic solvent in general and for mobile phases containing methanol rather than acetonitrile. For mobile phases containing less than about 20 % (v/v) organic solvent the mobile phase was unable to completely wet the stationary phase resulting in a significant change in the phase ratio and for acetonitrile (but less so methanol) changes in the solvation environment indicated by a discontinuity in the system maps.  相似文献   

20.
A novel stationary phase is demonstrated for the separation of proteins. Capillary-channeled polymer (C-CP) fibers provide a stationary phase that is characterized by a high surface activity (yielding strong wicking action) and drastically reduced back pressures. Columns prepared by pulling approximately 1200 50- micro m diameter polypropylene C-CP fibers through stainless steel tubing with column dimensions of 4.6-mm i.d. and 306-mm length exhibit reversed-phase characteristics in the separation of the proteins. A gradient method [95:5 water-acetonitrile (ACN)/propanol (1:1) to 35:65 water-ACN/propanol] with trifluoroacetic acid added as an ion-pairing agent yields high-quality separations of superoxide dismutase, hemoglobin, hemocyanin, and myoglobin. It is believed that the C-CP fiber stationary phase holds a number of promising traits for applications in both analytical and prep-scale separations of diverse organic species, including a wide range of biomolecules.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号