首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Summary: A rapidly expanding field of on-line process monitoring and on-line control in biotechnology, food industry, pharmaceutical industry, process chemistry, environmental measuring technology, water treatment and sewage processing requires the development of new micro fabricated reliable chemical and biosensors that are specific for particular species and can attain the analytic information in a faster, simpler and cheaper manner. Using a functionalised polymer coating in sensors provides the possibility to detect, transmit and record the information regarding the concentration change or the presence of a specific analyte (a chemical or biological substance that needs to be measured) by producing a signal proportional to the concentration of the target analyte. However, the sensor response time and signal reproducibility are limited by the visco-elastical and hysteresis behaviour of the polymer material. We propose some methods improving the properties of the chemical sensors on the basis of thermo-shrinking N-isopropylacrylamide (NIPAAm) copolymer gels.  相似文献   

2.
Rohe T  Becker W  Kölle S  Eisenreich N  Eyerer P 《Talanta》1999,50(2):283-290
In recent years, near infrared (NIR) spectroscopy has become an analytical tool frequently used in many chemical production processes. In particular, on-line measurements are of interest to increase process stability and to document constant product quality. Application to polymer processing e.g. polymer extrusion, could even increase product quality. Interesting parameters are composition of the processed polymer, moisture, or reaction status in reactive extrusion. For this issue a transmission sensor was developed for application of NIR spectroscopy to extrusion processes. This sensor includes fibre optic probes and a measuring cell to be adapted to various extruders for in-line measurements. In contrast to infrared sensors, it only uses optical quartz components. Extrusion processes at temperatures up to 300 degrees C and pressures up to 37 MPa have been investigated. Application of multivariate data analysis (e.g. partial least squares, PLS) demonstrated the performance of the system with respect to process monitoring: in the case of polymer blending, deviations between predicted and actual polymer composition were quite low (in the range of +/-0.25%). So the complete system is suitable for harsh industrial environments and could lead to improved polymer extrusion processes.  相似文献   

3.
Du M  Flanagan JH  Lin B  Ma Y 《Electrophoresis》2003,24(18):3147-3153
The detection of point and other simple mutations in DNA is important for cancer research and diagnosis and other biological studies. Capillary electrophoresis has been successfully used for separating DNA fragments. However, a low-viscosity polymer sieving buffer for DNA separation with on-line coating has never been reported. In this paper, a new method using capillary electrophoresis with on-line coating and laser-induced fluorescence detection (CE-LIF) for screening for point or simple DNA mutations has been demonstrated. The method uses an on-line dynamic coating technique that increases capillary lifetime and analysis reproducibility, and employs a low-viscosity polymer solution, which allows the user to rinse the capillary rapidly and refill with polymer solution easily. Experiments proved that the additives in the separation buffer for on-line capillary coating do not affect the separation efficiency of the running buffer, and do not interfere with the formation of hydrogen-bonded network between boric acid, mannitol and hydroxypropylmethylcellulose polymers. The stability of the dynamically coated capillary was quantitatively studied; the capillary lifetime was increased 6- to 7-fold compared with that of permanently coated CE columns. Standard DNA fragments containing mutations, with sizes of 209, 219, and 338 bps, were successfully separated and detected with this system, after the mutated DNA fragments were cleaved by CEL-I endonuclease. The technique is very sensitive for the size-separation of low-range, middle-range, and high-range DNA fragments. Results were compared with the HPLC methods developed by Transgenomic, Inc. and were in good agreement. The method should be applicable to mutation detection for all relevant biological and clinical studies. The factors influencing separations and the stability of dynamic capillary coatings are also discussed in the paper.  相似文献   

4.
Molten polymer process streams are difficult to analyze either in- or on-line because of sampling problems due to the high temperature and viscosity of the molten state. Real-time monitoring of chemical compositions in these processes can significantly improve safety and product quality and minimize process costs and waste. The information content of the mid-infrared spectrum combined with the recent development of rugged process Fourier transform (FT) IR spectrometers is stimulating the application of process FT-IR to industrial polymer melt processes. Sampling considerations for polymer melts are reviewed. Also, the use of FT-IR spectrometry for on-line measurements of the polymer composition for polymer blends and copolymers in the melt, and the question of how this information could be used to monitor and control the quality of the product given by the process are discussed.  相似文献   

5.
The development of rapid and simple wall coating strategies for high-efficiency electrophoretic separation of DNA is of crucial importance for the successful implementation of miniaturized polymeric DNA analysis systems. In this report, we characterize and compare different methods for the chemical modification of poly(methyl methacrylate) (PMMA) surfaces for the application of wall coating polymers. PMMA surfaces coated with 40 mol% diethylacrylamide and 60 mol% dimethylacrylamide are compared to the PMMA surfaces first oxidized and then coated with hydroxypropylmethyl-cellulose or poly(vinyl alcohol) (PVA). PMMA oxidation was accomplished with UV/ozone or an aqueous solution of HNO(3) to yield hydrogen-bond donors for the spontaneous adsorption of the coating polymers. Contact angle measurements of UV/ozone exposed PMMA surfaces indicate increase in hydrophilicity, and polymer coated surfaces show a strong dependence on the coating polymer and the oxidation method. Fast and repeatable electrophoretic separations of a 10-base and 20-base DNA ladder were performed in PMMA micro CE devices. All analyses were completed in less than 10 min, resulting in the number of theoretical plates as high as 583 000 in a 7.7 cm long separation channel. The duration of UV/ozone treatment was found to have a considerable impact on separation performance. The microchips irradiated with UV for 10 min and coated with PVA as well as the microchips treated with HNO(3) and coated with HPMC were found to have the best separation performance. These results demonstrate facile and robust methods for the surface modification of PMMA enabling low-cost single use devices for electrophoretic DNA separations.  相似文献   

6.
The weathering resistance of organic materials has been substantially increased by protecting their surface with a photocured coating containing both a UV absorber (UVA) and a radical scavenger (HALS). A kinetic study by real-time IR spectroscopy has shown that HALS have no effect on the cure rate, whereas UV absorbers slow down the cure process, due to their radiation inner filter effect. 3D analysis of the depth of cure profile revealed an incomplete cure at the coating/substrate interface, leading to adhesion failure. To prevent this detrimental effect, the UV-cured coating was photochemically grafted onto the substrate. The polymer material was first coated with a thin layer of a benzophenone solution in a diacrylate monomer. Polymer radicals, generated by hydrogen abstraction from the substrate by the excited benzophenone molecules, effectively initiate the polymerization of the acrylate functions, thus ensuring a chemical bonding between the coating and the substrate. The grafting reaction was characterized by ATR spectroscopy analysis and by surface energy measurements. Excellent adhesion was achieved by applying to the treated substrate a photocurable acrylate coating, containing the light stabilizers, because of the copolymerization reaction taking place with the unreacted acrylate double bonds of the base coat, upon UV exposure. The efficiency of this on-line stabilization process has been demonstrated on poly(vinyl chloride) that was made eight times more resistant to accelerated weathering. © 1998 John Wiley & Sons, Inc. J. Polym. Sci. A Polym. Chem. 36: 2571–2580, 1998  相似文献   

7.
A sol-gel polydimethyldiphenylsiloxane (PDMDPS) coating was developed for capillary microextraction on-line hyphenated with high-performance liquid chromatography (HPLC). This coating was created using methyltrimethoxysilane (MTMS) as the sol-gel precursor and di-hydroxy-terminated PDMDPS as the sol-gel active polymer. The methyl and phenyl groups on the sol-gel active polymer and the methyl groups on the sol-gel precursor ultimately turned into pendant groups providing the ability to extract non-polar analytes. A 40-cm segment of 0.25mm I.D. fused silica capillary containing the sol-gel PDMDPS coating was installed as an external sampling loop in an HPLC injection port. Aqueous samples containing polycyclic aromatic hydrocarbons (PAHs), aromatic compounds, ketones, and aldehydes were passed through this capillary wherein the analytes were extracted by the sol-gel coating. The extracted analytes were then transferred to the HPLC column using isocratic or gradient elution with an acetonitrile/water mobile phase. This capillary demonstrated excellent extraction capability for non-polar (e.g., polycyclic aromatic hydrocarbons and aromatic compounds) as well as moderately polar compounds, such as aromatic amines, ketones, and aldehydes. The test results indicate that PDMDPS can be successfully immobilized into a sol-gel network and that the resulting solvent-resistant sol-gel organic-inorganic hybrid coating can be effectively used for on-line hyphenation of capillary microextraction with high-performance liquid chromatography. The test results also indicate that the sol-gel PDMDPS coated capillary is resistant to high-temperature solvents, making it suitable for applications in high-temperature HPLC. To the best of our knowledge, this is the first report on the creation of a silica-based sol-gel PDMDPS coating used in capillary microextraction on-line hyphenated to HPLC.  相似文献   

8.
A new approach is reported on the use of poly(N-isopropylacrylamide) (PNIPAM)-coated molecularly imprinted beads (coated MIP beads) for controlling the release of protein. The coated MIP beads were composed of double layers, an internal thermosensitive lysozyme-imprinted layer, and an external PNIPAM layer. The coated MIP beads were prepared by two-step surface-initiated living-radical polymerization (SIP). In this systemic study, the coated MIP beads had good selectivity to the template protein (lysozyme) and temperature stimulus-responsive behavior, both of which were superior to those of MIP beads having a layer of thermosensitive lysozyme-imprinted polymer only. Using the coated MIP beads, reference proteins and the template lysozyme could be released separately at 38 °C and at 23 °C. The corresponding coated non-imprinted beads (coated NIP beads) did not have such double thermosensitive “gates” with specific selectivity for a particular protein. The proposed smart controlled imprinted system for protein is attractive for chemical carriers, drug-delivery system, and sensors.  相似文献   

9.
Emulsion‐based coatings and adhesives are in growing demand due to an increased awareness of health and safety issues arising from solvent‐based polymer manufacturing processes. However, emulsion‐based techniques often require additional development to achieve equal or better application performance compared to solvent‐based processes. The inclusion of nanoparticles in emulsion‐based coatings and adhesives can be considered as a promising means to enhance performance. This paper reviews the current progress on the synthesis of emulsion‐based nanocomposites for coating and adhesive applications and addresses the principles and techniques for nanoparticle dispersions and their inclusion into polymer latexes. The effects of nanoparticle shape and size on the enhancement of nanocomposite properties are also highlighted. Among the reinforcing nanoparticles such as nanoclays, carbon nanotubes, and cellulose nanocrystals (CNCs), CNCs are promising due to their abundance, nontoxicity, and accessible surface hydroxyl groups, which facilitate their compatibility with polymer latexes via physical and chemical treatments.  相似文献   

10.
Quartz Crystal Microbalance (QCM) based sensors have been used extensively to detect trace amounts of organic chemical vapors. These devices typically incorporate a polymer coating as an active layer that can bind the analytes of interest. Analyte adsorption causes a shift in the resonant frequency of the device proportional to the amount of adsorbed material. Currently some of the polymer coatings used in these sensors utilize hydrogen bonding to adsorb analytes. Dipole-dipole type interactions can also be utilized to promote interaction of the analytes with the polymer coating. Polymer coating containing segments that have a permanent molecular dipole can interact with explosive taggants. In this study, novel polypropylene glycol based polymers that incorporate both hydrogen bonding moieties and segments having large permanent dipole moment (p-nitroazobenzene functional groups) were synthesized and tested. The precursor polymer was prepared by the polymerization of the diglycidyl ether end functionalized polypropylene glycol macromer and aniline. The precursor polymers were post functionalized by an azo-coupling reaction. The sensor response to saturated vapors of o-nitrotoluene, nitrobenzene and 2,4 dinitrotoluene (DNT) saturated vapors was evaluated. Incorporation of p-nitroazobenzene moieties in the polymer increased the sensitivity of detection of the analytes. These studies offer new possibilities for using combination of interactions to improve the sensitivity of the QCM based sensors in the detection of nitroaromatic materials.  相似文献   

11.
Stir‐bar sorptive extraction is based on the partitioning of target analytes between the sample (mostly aqueous‐based liquid samples) and a stationary phase‐coated magnetic stir bar. Until now, only PDMS‐coated stir bars are commercially available, restricting the range of applications to the non‐selective extraction of hydrophobic compounds due to the apolar character of PDMS. In this work, a novel stir bar coated with molecularly imprinted polymer as selective extraction phase for sorptive extraction of thiabendazole (TBZ) was developed. Two different procedures, based on physical or chemical coating, were assessed for the preparation of molecularly imprinted stir bars. Under optimum conditions, recoveries achieved both in imprinted and non‐imprinted polymer stir bars obtained by physical coating were very low, whereas TBZ was favourably retained by imprinted over non‐imprinted polymer stir bars obtained by chemical coating and thus the latter approach was used in further studies. Different parameters affecting both stir‐bars preparation (i.e. cross‐linker, porogen, polymerization time) and the subsequent selective extraction of TBZ (i.e. washing, loading and elution solvents, extraction time) were properly optimized. The molecularly imprinted coated stir bars were applied to the extraction of TBZ from citrus samples (orange, lemon and citrus juices) allowing its final determination at concentrations levels according to current regulations.  相似文献   

12.
杜迎翔  陈建民 《分析化学》2004,32(10):1295-1298
以阴离子聚合物聚丙烯酸为涂层材料,研制了一种新型的阴离子型毛细管电泳Polybrene/聚丙烯酸双涂层柱。此法不但操作方便,而且毛细管涂层重现性好,柱寿命超过100次电泳分析,经1mol/LHCl、0.1mol/LNaOH、CH3OH和CH3CN等冲洗15min后,涂层未发生变化,化学稳定性强。将该双涂层柱用于以新型多糖作手性选择剂的碱性药物手性拆分中,毛细管内壁对碱性药物的吸附作用大大降低,样品色谱峰对称性显著改善,手性分离的效果良好。  相似文献   

13.
Polypyrrole is one of the most frequently studied conducting polymers, having high electrical conductivity and stability, suitable for multi-functionalised applications. Coatings of chemically synthesised polypyrrole applied onto various organic and inorganic materials, such as polymer particles and films, nanoparticles of metal oxides, clay minerals, and carbon nanotubes are reviewed in this paper. Its primary subject is the formation of new materials and their application in which chemical oxidative polymerisation of pyrrole was used. These combined materials are used in antistatic applications, such as anti-corrosion coating, radiation-shielding, but also as new categories of sensors, batteries, and components for organic electronics are created by coating substrates with conducting polymer layers or imprinting technologies.  相似文献   

14.
A novel positively charged polymer of quaternary ammonium substituted agarose (Q-agarose) has been synthesized and explored for use as a coating in capillary electrophoresis. The fast and simple coating procedure is based on a multi-site electrostatic interaction between the polycationic agarose polymer and the negatively charged fused-silica surface. By simply flushing fused-silica capillaries with hot polymer solution a positively charged, hydrophilic deactivation layer is achieved. The polymer surface provides an intermediate electroosmotic flow of reversed direction, over a range of pH 2-11, compared to unmodified fused-silica. The coating procedure was highly reproducible with an RSD of 4%, evaluated as the electroosmotic flow mobility for 30 capillaries prepared at 10 different occasions. The application of Q-agarose coated capillaries in separation science was investigated using a set of basic drugs and model proteins and peptides. Due to the intermediate electroosmotic flow generated, the resolution of basic drugs could be increased, compared to using bare fused-silica capillaries. Moreover, the coating enabled separation of proteins and peptides with efficiencies up to 300.000 plates m(-1).  相似文献   

15.
Gas sensors are demanded in many different application fields. Especially the ever-growing field of batteries creates a great need for early hazard detection by gas sensors. Metal oxides are well known for gas sensing; however, moisture continues to be a major problem for the sensors, especially for the application in battery systems. This study reports on a new type of moisture protected gas sensor, which is capable to solve this problem. Sensitive nano-materials of CuO/Cu2O/ZnO:Fe heterostructures are grown and subsequently coated with an ultrathin hydrophobic cyclosiloxane-polymer film via initiated chemical vapor deposition to protect the sensor from moisture. The monomer 1,3,5-trimethyl-1,3,5-trivinylcyclotrisiloxane is combined with the initiator perfluorobutanesulfonyl fluoride to obtain hydrophobic properties. Surface chemistry, film formation and preservation of functional groups are confirmed by X-ray photoelectron spectroscopy and Fourier-transform infrared spectroscopy. It turns out that the hydrophobicity is retained even after annealing at 400 °C, which is ideal for gas sensing. Molecular distances in the polymer nanolayer are estimated by geometry optimization via MMFF94 followed by density functional theory. Compared with unprotected CuO/Cu2O/ZnO:Fe, the coated CuO/Cu2O/ZnO:Fe exhibit a much better sensing performance at a higher relative humidity, as well as tunability of the gas selectivity. This is highly beneficial for hazard detection in case of thermal runaway in batteries because the sensors can be used under high concentrations of relative humidity, which is ideal for Li–S battery applications.  相似文献   

16.
Chemical sensors can also be used for process control since they are able to follow concentration changes nearly instantaneously. The mass sensitive quartz-micro-balance (QMB), coated with cross-linked cyclodextrin cavities was applied to monitor the formation of the Grignard reagent. It was possible to detect the reactant chlorobenzene even in a saturated diethyl ether atmosphere down to some ppm (μL/L). This is equivalent to a molar ratio of 50000:1 of diethyl ether to chlorobenzene. The sensor characteristic is completely linear in the concentration range from 10 to 500 ppm (μL/L) chlorobenzene. As a practical application, the end point of the Grignard reaction can be determined in an accuracy of approximately 2% of the reagent supply. This was achieved by a direct on-line acquisition of the QMB frequency response or its derivative. Received: 7 January 1998 / Accepted: 1 February 1998  相似文献   

17.
Physically adsorbed (dynamic) polymeric wall coatings for microchannel electrophoresis have distinct advantages over covalently linked coatings. In order to determine the critical factors that control the formation of dynamic wall coatings, we have created a set of model polymers and copolymers based on N,N-dimethylacrylamide (DMA) and N,N-diethylacrylamide (DEA), and studied their adsorption behavior from aqueous solution as well as their performance for microchannel electrophoresis of DNA. This study is revealing in terms of the polymer properties that help create an "ideal" wall coating. Our measurements indicate that the chemical nature of the coating polymer strongly impacts its electroosmotic flow (EOF) suppression capabilities. Additionally, we find that a critical polymer chain length is required for polymers of this type to perform effectively as microchannel wall coatings. The effective mobilities of double-stranded (dsDNA) fragments within dynamically coated capillaries were determined in order to correlate polymer hydrophobicity with separation performance. Even for dsDNA, which is not expected to be a strongly adsorbing analyte, wall coating hydrophobicity has a deleterious influence on separation performance.  相似文献   

18.
Chemical sensors can also be used for process control since they are able to follow concentration changes nearly instantaneously. The mass sensitive quartz-micro-balance (QMB), coated with cross-linked cyclodextrin cavities was applied to monitor the formation of the Grignard reagent. It was possible to detect the reactant chlorobenzene even in a saturated diethyl ether atmosphere down to some ppm (μL/L). This is equivalent to a molar ratio of 50000:1 of diethyl ether to chlorobenzene. The sensor characteristic is completely linear in the concentration range from 10 to 500 ppm (μL/L) chlorobenzene. As a practical application, the end point of the Grignard reaction can be determined in an accuracy of approximately 2% of the reagent supply. This was achieved by a direct on-line acquisition of the QMB frequency response or its derivative. Received: 7 January 1998 / Accepted: 1 February 1998  相似文献   

19.
The weathering characteristics of thin film formed from plasma polymerisation of perfluoro(methylcyclohexane) on an EPDM substrate under cold plasma process operated at 13.56 MHz was investigated using an ATLAS Ci 3000 Xenon weatherometer. The effects of weathering conditions on the chemical composition of the substrate and the coating were examined using photoacoustic Fourier transform infrared spectroscopy (PA-FTIR) and X-ray photoelectron spectroscopy (XPS). The wear behaviour was examined using scanning electron microscopy (SEM). The change in the surface morphological behaviour of the coating indicates that the mending line of the patch-wise coating deposition or the fissure/crack line of the coating is particularly sensitive to the initiation of decomposition. FTIR and XPS spectroscopic investigations confirm that under humid and UV conditions, elimination of fluorine and introduction of new oxygen-containing functional groups play predominant role in the decomposition of the coating. Plausible mechanisms of degradation for the elastomer and the coating have been proposed. The coated substrate shows superior abrasion resistance characteristics with respect to the neat elastomer. The adhesion between the substrate and the plasma polymer coating appears to be excellent and remains strong after weathering.  相似文献   

20.
Zirconia nanoparticles were encapsulated by polyethylene via a polymerization compounding method using a Ziegler-Natta catalyst. The chemical reaction was carried out in an organic solvent under moderate pressure of ethylene monomer. Transmission electron microscopy (TEM) indicated the presence of a thin layer of polymer, about 6 nm, uniformly applied around the particles. However, the thickness of coating layer can be controlled as a function of time and operating conditions of the process. The morphology study using scanning electron microscopy (SEM) as well as TEM revealed that although the nanoparticles seem to be coated individually, some agglomerates, encapsulated by a polymer film, could be observed. The grafting of the catalyst to the original surface of particles was further confirmed by X-ray photoelectron spectroscopy (XPS).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏