共查询到20条相似文献,搜索用时 15 毫秒
1.
《Biomedical chromatography : BMC》2017,31(12)
Through blocking the cardiac persistent sodium current, riluzole has the potential to prevent myocardial damage post cardiac bypass surgery. A sensitive UHPLC–MS/MS method was developed and validated for quantitation of riluzole and 5‐methoxypsoralen in human plasma and myocardial tissue homogenate using a liquid–liquid extraction with dichloromethane. The chromatographic separation was achieved using Shimadzu Shim‐pack XR‐ODS III, 2.0 × 50 mm, 1.6 μm column with a gradient mobile phase comprising methanol and ammonium acetate buffer pH 3.6 in purified water. The analyte and internal standard were separated within 3.5 min. Riluzole quantitation was achieved using the mass transitions of 235–138 for riluzole and 217–156 for 5‐methoxypsoralen. The method was linear for riluzole plasma concentrations from 0.2 to 500 ng/mL and myocardial tissue homogenate concentrations from 0.2 to 100 ng/mL. The method developed was successfully applied to a clinical study for patients receiving riluzole while undergoing cardiac bypass surgery. 相似文献
2.
J P Weijers-Everhard J Wijker R Verrijk H H van Rooij W Soudijn 《Journal of chromatography. A》1986,374(2):339-346
The abuse of flunitrazepam (Rohypnol), a potent benzodiazepine-type hypnotic, cannot be established with the widely used immunoassays for urine analysis owing to lack of specificity. A simple method is described which is based on the formation of acridine derivatives and measures the sum of metabolites of flunitrazepam in urine samples using column liquid chromatography with fluorimetric detection. 相似文献
3.
A K Singh U Mishra M Ashraf E H Abdennebi K Granley D Dombrovskis D Hewetson C M Stowe 《Journal of chromatography. A》1987,404(1):223-232
Chemical ionization- and electron impact ionization-selective ion monitoring provided a simple and sensitive method for measuring detomidine (Domosedan), a potent sedative-analgesic drug for horses and cattle. Chemical ionization was at least 10 times more sensitive than electron impact ionization. By using propranolol as an internal standard, we found that the recovery of detomidine from the extraction procedure used in this study was greater than 75% for plasma, whole blood, or urine samples. Approximately 68% of detomidine was bound to plasma protein and 53% was bound to red blood cells. 相似文献
4.
A monolithic spin column was developed for the extraction of analytes from biological materials. This column was constructed by packing a monolithic silica disk into a spin column. Sample loading, washing, and elution of the target drugs were accomplished simply by centrifugation of the column. Opiates and benzodiazepines are abused throughout the world. Identification and quantification of these drugs is very important to solve crimes or the cause of death. Three opiates (morphine, codeine, and dihydrocodeine) were extracted from urine and serum by using the column. After conversion to trimethylsilyl derivatives of the opiates by vigorous mixing with the derivatizing reagent, the solution was subjected to GC/MS. A linear curve was observed for opiates from 10 to 2500 ng/mL in urine and 5 to 1200 ng/mL in serum, respectively (correlation coefficient > 0.996). For benzodiazepines, the hydroxyl metabolites of triazolam and etizolam were extracted from urine using the column, and the eluate was directly analyzed by HPLC/MS without evaporation. The LOD values were at the ppb level, with RSD values lower than 15%. The proposed methods were successfully applied to clinical and forensic cases, and good agreement of results was obtained compared to conventional methods. 相似文献
5.
M. Reza Hormozi-Nezhad M. Azargun N. Fahimi-Kashani 《Journal of the Iranian Chemical Society》2014,11(5):1249-1255
We report herein the development of a highly sensitive colorimetric method for detection of d-Penicillamine using citrate-capped gold nanoparticles (AuNPs). This assay relies upon the distance-dependent of gold nanoparticles surface plasmon resonance band of gold nanoparticles. By replacing the thiol-containing chelator drug, d-Penicillamine, with citrate on the gold nanoparticles surface, a new peak appearing at a longer wavelength intensifies and shifts further to the red from the original peak position due to aggregation of gold nanoparticles which depends on ionic strength, gold nanoparticles and d-Penicillamine concentration. During this process, the plasmon band at 521 nm decreases gradually along with the formation of a new red-shifted band at 630 nm. The calibration curve which is derived from the ratio intensities of absorbance at longer wavelength (630 nm) to original wavelength (521 nm) displays a linear relation in the range of 5.0 × 10?6–3.0 × 10?4 M d-Penicillamine. Lower limit of detection for d-Penicillamine, at the signal-to-noise ratio of 3 (3σ), was 3.8 × 10?6 M. The developed methodology was successfully applied for the determination of d-Penicillamine in human urine and plasma. 相似文献
6.
Summary A rapid method is described for the determination of lidocaine and its metabolites in horse urine using a column switching technique and HPLC analysis. This procedure offers a sensitive assay without the need for time consuming extractions. 相似文献
7.
A high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) method for the simultaneous detection of succinylcholine (SUX) and its metabolite succinylmonocholine (SMC) in serum and urine is presented. For internal standardization using isotope dilution, the deuterated compounds SUX-d(18) and SMC-d(3) were employed. Full validation was performed according to international guidelines. Solid-phase extraction (SPE) of acidified samples was accomplished using Strata-X polymeric reversed phase cartridges together with heptafluorobutyric acid (HFBA) as ion-pairing reagent. Separation was achieved within 13 min on a Phenomenex Synergi Hydro RP C18 column (4 microm, 150 x 2 mm) using a gradient of 5 mM ammonium formate buffer pH 3.5 and acetonitrile.To ensure the method's applicability in forensic as well as clinical toxicology, the specific demands of both research fields were taken into account, and the method was thus validated for a low and high concentration range. For both serum and urine as sample matrix, the validation revealed good intraday and interday precisions, consistently ranging below 15% for the lowest and below 10% for elevated concentrations. Accuracy was likewise good and never exceeded 10%. Extraction recovery was excellent, ranging between 88.1 and 103.9% for SUX and SMC in both tested matrices. Matrix effects were significant, the otherwise optimized extraction and detection methods, however, allowed for a very satisfactory sensitivity of the described method: For serum, the limits of detection and quantitation were determined to be 1.9 and 6.0 ng/ml for SUX, as well as 2.5 and 8.6 ng/ml for SMC, respectively; for urine, the corresponding values were established to be 1.4 and 4.0 ng/ml (SUX), as well as 1.5 and 4.9 ng/ml (SMC).The presented method was successfully applied to authentic samples of two forensic cases investigated in the institute of forensic medicine in Bonn, allowing the diagnosis of SUX intoxications. 相似文献
8.
This study aimed to validate a sensitive and reliable analytical method for the pharmacokinetic study of atomoxetine in human plasma by liquid chromatography-electrospray ionization-tandem mass spectrometry. Metoprolol was used as an internal standard. After liquid-liquid extraction with methyl t-butyl ether, the supernatant was evaporated. The residue was then reconstituted and an aliquot was injected into the high performance liquid chromatographic system. Separation was performed on a Phenomenex Luna C18 column (2.0 mm × 100 mm, 3 μm particles) with a mobile phase of 10 mM ammonium formate buffer: methanol = 10: 90 (v/v). Tandem mass spectrometry was performed in the electrospray ionization positive ion mode using the multiple reaction monitoring mode for quantification. The mass transition pairs of m/z 256 → 44 for atomoxetine and m/z 268 → 116 for the internal standard were used. The flow rate of the mobile phase was 0.25 mL/min and the retention times of atomoxetine and the internal standard were found to be 1.0 and 0.9 min, respectively. The calibration curve for atomoxetine was linear in the concentration range of 1–750 ng/mL (r 2 = 0.9992) with a lower limit of quantification of 1 ng/mL. The mean accuracy for atomoxetine was 93–102%. The coefficients of variation (precision) in the intra- and inter-day validation for atomoxetine were 4.0–6.8 and 1.1–9.6%, respectively. The pharmacokinetic parameters of atomoxetine were evaluated after administration of a 40-mg single oral dose to twelve healthy male volunteers. The mean AUC0–24 h, C max, T max and T 1/2 for atomoxetine were 1.9 ± 0.8 μg h/mL, 0.34 ± 0.11 μg/mL, 1.0 ± 0.5 h and 3.9 ± 1.3 h, respectively. 相似文献
9.
A method based on stochastic resonance for the detection of weak analytical signal 总被引:10,自引:0,他引:10
An effective method for detection of weak analytical signals with strong noise background is proposed based on the theory of stochastic resonance (SR). Compared with the conventional SR-based algorithms, the proposed algorithm is simplified by changing only one parameter to realize the weak signal detection. Simulation studies revealed that the method performs well in detection of analytical signals in very high level of noise background and is suitable for detecting signals with the different noise level by changing the parameter. Applications of the method to experimental weak signals of X-ray diffraction and Raman spectrum are also investigated. It is found that reliable results can be obtained. 相似文献
10.
Yamamoto T Kusama M Matsuno K Sugiyama E Yamada Y Iga T 《Biomedical chromatography : BMC》2002,16(7):453-454
Buformin is a widely used as an antidiabetic agent but its renal excretion is still controversial. A new HPLC method with ultraviolet (UV) detection for the determination of buformin in plasma and urine has been developed. After protein precipitation or dilution, buformin and internal standard phenformin were resolved on an octadecyl silica column and detected by UV detection at 233 nm. Intra- and inter-day coefficients of variation were <9%. The limit of quantification was around 0.05 micro g/ml for plasma and 2.5 micro g/ml for urine. 相似文献
11.
Clenbuterol, a beta-adrenergic agonist, is used in the treatment of recurrent airway obstruction in horses. It is prohibited by horse racing authorities, because of its stimulating and growth-promoting properties. However, information on detection times of clenbuterol after administration by nebulization is lacking. In this study, a fast, sensitive quantitative GC-MS(2) method for the detection of clenbuterol in urine was developed. Alkaline liquid-liquid extraction was followed by derivatization to a cyclic methyl boronate derivative and analysis on a Finnigan MAT GCQ instrument. Method validation showed good linearity in the range 0.1-2.0 ng/mL, excellent repeatability and specificity. The limit of quantitative detection of the method was 0.1 ng/ml. Different instrumental parameters of the ion trap mass spectrometer were changed to increase the number of diagnostic ions for the cyclic methyl boronate derivative of clenbuterol. The influence of these changes and their applicability within the requirements and the criteria for mass spectrometry set by the responsible regulatory bodies are discussed. Clenbuterol was administered via nebulization to five standardbred mares (0.4 micro g/kg body weight). Analysis of the urine samples resulted in the detection of clenbuterol, as early as 2 h post administration and for up to 36 h post treatment. Generally, maximum urinary concentrations of 1.2 ng/mL were reached after -6-9 h. 相似文献
12.
Selective extraction based on poly(MAA‐VB‐EGMDA) monolith followed by HPLC for determination of hordenine in plasma and urine samples 下载免费PDF全文
Hordenine is an active compound found in several foods, herbs and beer. In this work, a novel sorbent was fabricated for selective solid‐phase extraction (SPE) of hordenine in biological samples. The organic polymer sorbent was synthesized in one step in the plastic barrel of a syringe by a pre‐polymerization solution consisting of methacrylic acid (MAA), 4‐vinylphenylboronic acid (VB) and ethylene glycol dimethacrylate (EGDMA). The conditions for preparation were optimized to generate a poly(MAA‐VB‐EGMDA) monolith with good permeability. The monolith exhibited good enrichment efficiency towards hordenine. By using tyramine as the internal standard, a poly(MAA‐VB‐EGMDA)‐based SPE‐HPLC method was established for analysis of hordenine. Conditions for SPE, including volume of eluting solvent, pH of sample solution, sampling rate and sample volume, were optimized. The proposed SPE‐HPLC method presented good linearity (R2 = 0.9992) within 10–2000 ng/mL and the detection limits was 3 ng/mL, which is significantly more sensitive than reported methods. The method was also applied in plasma and urine samples; good capability of removing matrices was observed, while hordenine in low content was well extracted and enriched. The recoveries were from 90.6 to 94.7% and from 89.3 to 91.5% for the spiked plasma and urine samples, respectively, with the relative standard deviations <4.7%. Copyright © 2014 John Wiley & Sons, Ltd. 相似文献
13.
The concentrations of nandrolone metabolites, 19-norandrosterone (19-NA) and 19-noretiocholanolone (19-NE) were analysed in urine samples of professional athletes doing intense physical activity and sedentary subjects to verify if there was endogenous production of nandrolone and if there was any link between physical effort and the urinary metabolites of the steroid. We collected 18 urine samples from professional footballers age range 20-30 years, all from the same team, and 18 urine samples from males not doing any physical activity, age range 20-30 years. Neither group used nandrolone. Qualitative and quantitative analyses of urinary nandrolone metabolites were carried out by GC/MS followed by GC/MS/MS to confirm positive samples. This technique has been demonstrated to be an excellent analytical approach for the determination of anabolic steroids at very low detection limits in complex matrices such as urine. In five urine samples from professional footballers traces of 19-NA were detected. No trace of 19-NA was found in the group of sedentary subjects and no trace of 19-NE was found in any urine sample. The absence of nandrolone metabolites in sedentary subjects supports the hypothesis that the presence of 19-NA and 19-NE could be linked to physical effort even though the origin is not yet clear. 相似文献
14.
Eshwar Jagerdeo Madeline A. Montgomery Roman P. Karas Martin Sibum 《Analytical and bioanalytical chemistry》2010,398(1):329-338
Marijuana is one of the most commonly used illicit substances. The high usage of this substance results in it being commonly
encountered in clinical samples throughout the USA and Europe. Due to its wide availability and use, marijuana is also commonly
encountered in forensic toxicology laboratories. The proposed method utilized an automated solid phase extraction (SPE) coupled
to liquid chromatography/mass spectrometry (LC/MS). The automated SPE procedure was developed using Hysphere C8-EC sorbent,
and the high performance liquid chromatography (HPLC) separation was performed using an Xterra MS C18 column with a total runtime of 10 min. The standard curves linearity generally fell between 6 and 500 ng/mL. The limits of
detection ranged from 2 to 4 ng/mL, and the limits of quantitation ranged from 8 to 12 ng/mL. The bias and imprecision were
determined using a simple analysis of variance (single factor). The results demonstrate bias as <11% and percent imprecision
as <12% for all components at four quality control levels. This method has been in use for over 2 years and has been applied
to numerous forensic samples. When compared to other published methods, it exceeds others in its simplicity and speed of analysis.
This method takes advantage of robotics and automation for a total analysis time of 10 min, including sample preparation,
separation, and detection. 相似文献
15.
A rapid and sensitive method using liquid chromatography-tandem mass spectroscopy (LC-MS/MS) was developed and validated for the quantitative determination of cynandione A in rat plasma and tissues. The plasma samples were pretreated by liquid-liquid extraction with ethyl acetate after the internal standard (honokiol) had been spiked. The tissue samples were homogenized with physiological saline and treated further like the plasma samples. The separation was performed using a Zorbax SB-C(18) column (3.5 microm, 2.1 x 100 mm) and a C18 guard column (5 microm, 4.0 x 2.0 mm) with an isocratic mobile phase consisting of methanol-0.1% formic acid (78:22, v/v) at a flow rate of 0.2 mL/min. The Agilent G6410A triple quadrupole LC/MS system was operated under the multiple-reaction monitoring mode using the electrospray ionization technique in negative mode. The nominal retention times for cynandione A and honokiol were 1.41 and 2.63 min, respectively. The method was validated within the concentration range 0.2-1000 ng/mL in plasma and homogenized tissue for cynandione A, and the calibration curves were linear with correlation coefficients >0.992. The lower limit of quantification of cynandione A was 0.2 ng/mL. The intra-day and inter-day precision and accuracy of the assay in plasma were less than 14.4%, while the intra-day and inter-day precision and accuracy of the assay in tissue homogenate were less than 14.2%. This method proved to be suitable for study of pharmacokinetics and tissue distribution of cynandione A in rat. 相似文献
16.
Zhiping Feng Siyuan Yu Wei Liu Li Yang Yang Liu Suodi Zhai Fang Wang Xianhua Zhang 《Biomedical chromatography : BMC》2015,29(8):1167-1172
A sensitive, rapid and robust HPLC method with tandem mass spectrometry (HPLC/MS/MS) detection has been developed and validated for the quantification of sotalol in rat plasma. Plasma samples were precipitated with acetonitrile before analysis. The chromatographic separation was performed on an Atlantis hydrophilic interaction liquid chromatography Silica column (50 × 2.1 mm, 3 µm) with a gradient mobile phase of 10 mm NH4COOH (containing 0.2% of formic acid) as buffer A and acetonitrile as mobile phase B. Sotalol (m/z 273.2 → 255.1) and atenolol (the internal standard, IS, m/z 267.2 → 190.1) were monitored under positive ionization mode with 5500 QTRAP. Retention time of sotalol and the IS were 2.69 and 3.43 min, respectively. The linear range was 5–500 nm based on the analysis of 0.1 mL of plasma. The intrabatch precision ranged from 1.2 to 6.1%, and the inter‐batch precision was from 3.3 to 6.5%. The coefficient of variation of IS‐normalized matrix factor was 7.6%. Experiments for stability were performed and the analyte was sufficiently stable. A run time of 6 min for each injection made it possible to analyze a high throughput of plasma samples. The assay was successfully applied to the determination of sotalol in rat plasma after a micro‐dose oral administration. Copyright © 2014 John Wiley & Sons, Ltd. 相似文献
17.
Vas G Conkrite K Amidon W Qian Y Bánki K Perl A 《Journal of mass spectrometry : JMS》2006,41(4):463-469
Transaldolase (TAL) is a key enzyme of the pentose phosphate pathway (PPP). TAL deficiency is a newly recognized cause of liver cirrhosis. We have developed an ion-pair LC separation combined with negative ion electrospray MS/MS detection method to assess PPP metabolites in urine samples from TAL-deficient mice. Sedoheptulose 7-phosphate (S7P), C5-polyols D-arabitol and D-ribitol, and 6-phosphogluconate (6PG) levels were markedly increased in urine of TAL-deficient mice with respect to those of wild-type and heterozygote littermates. The detection limits of S7P, D-arabitol, and 6PG were 0.15 +/- 0.015 pmol, 3.5 +/- 0.41 pmol, and 0.61 +/- 0.055 pmol, respectively. The limit of quantitation was 0.4 +/- 0.024 nmol/ml for S7P, 1.6 +/- 0.11 nmol/ml for 6PG and 10 +/- 0.7 nmol/ml for D-arabitol. Additional metabolites, hexose 6-phosphates (m/z 259), D-ribose 5-phosphate and D-xylulose 5-phosphate (m/z 229), D-fructose 1,6-diphosphate (m/z 339), C6-polyols (m/z 181) and GSSG (m/z 611), that have been positively identified in mouse urine, showed similar levels in control and TAL-deficient mice. 相似文献
18.
Xiongxin Dai Yuhang Cui Sheila Kramer-Tremblay 《Journal of Radioanalytical and Nuclear Chemistry》2013,296(1):363-368
Rapid bioassay methods for 90Sr in urine samples are needed to provide an early estimation of possible internal dose resulting from exposure to radiostrontium in the event of a radiological and nuclear emergency. In this work, a fast column separation method followed by liquid scintillation counting for detection of 90Sr in urine was developed. Replicate spike and blank samples were analyzed for performance evaluation of the method. Using this method, a detection limit of ~10 Bq L?1 for 90Sr can be achieved with a sample analysis turn-around time of 4 h for a set of 12 samples. The method is adequate to meet the radiobioassay acceptance criteria and is suitable for quick dose assessment of 90Sr exposure following a radiation emergency. 相似文献
19.
Jeon BW Yoo HH Jeong ES Kim HJ Jin C Kim DH Lee J 《Analytical and bioanalytical chemistry》2011,401(4):1353-1363
A sensitive and rapid method based on liquid chromatography-triple-quadrupole tandem mass spectrometry (LC-MS/MS) with electrospray ionization (ESI) has been developed and validated for the screening and confirmation of 44 exogenous anabolic steroids (29 parent steroids and 15 metabolites) in human urine. The method involves an enzymatic hydrolysis, liquid-liquid extraction, and detection by LC-MS/MS. A triple-quadrupole mass spectrometer was operated in positive ESI mode with selected reaction monitoring (SRM) mode for the screening and product ion scan mode for the confirmation. The protonated molecular ions were used as precursor ions for the SRM analysis and product ion scan. The intraday and interday precisions of the target analytes at concentrations of the minimum required performance levels for the screening were 2-14% and 2-15%, respectively. The limits of detection for the screening and confirmation method were 0.1-10 ng/mL and 0.2-10 ng/mL, respectively, for 44 steroids. This method was successfully applied to analysis of urine samples from suspected anabolic steroid abusers. 相似文献
20.
A new, fast and sensitive high‐performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC/ESI‐MS/MS) method was developed and validated for isovalerylshikonin in rat plasma using emodin as internal standard (IS). The analyte was extracted from rat plasma with ethyl acetate, after 10% HCl treatment and protein precipitated by methanol. The compound was separated on an Ultimate? XB‐C18 analytical column using a mobile phase of methanol–10 mM ammonium acetate in water–acetonitrile containing 0.05% formic acid (45 : 10 : 45, v/v/v) with isogradient elution. The analyte was detected in negative ion mode using multiple‐reaction monitoring. The method was validated and the specificity, linearity, lower limit of quantitation (LLOQ), precision, accuracy, recoveries and stability were determined. LLOQ was 9 ng/mL for isovalerylshikonin. Correlation coefficient (r) value for the linear range of the analyte was greater than 0.99. The intra‐day and inter‐day precision and accuracy were better than 8.52%. The relative and absolute recovery was above 86% and no matrix effects were observed for isovalerylshikonin. This validated method provides a modern, rapid and robust procedure for the pharmacokinetic study of the two compounds in rats after intravenous administration to rats (n = 4). Copyright © 2009 John Wiley & Sons, Ltd. 相似文献