共查询到20条相似文献,搜索用时 15 毫秒
1.
Okuna S Kiuchi M Arakawa R 《European journal of mass spectrometry (Chichester, England)》2006,12(3):181-187
Fragmentation of polyethers, such as poly(ethylene glycol) (PEG), poly(propylene glycol) and poly(tetramethylene glycol) was analyzed by matrix-assisted laser desorption/ionization tandem mass spectrometry (MALDI-MS/MS) using a quadrupole ion trap time-of-flight mass spectrometer (QIT-ToF). The Li adduct ion provided more abundant fragments than the Na and K adduct ions in the MS/MS spectra. A previous study had demonstrated four series fragments of hydroxyl-, vinyl- and formyl-terminated ions, as well as distonic cations, in high-energy fast atom bombardment MS/MS and MALDI collision-induced dissociation measurements of poly(ethylene glycol). In the present study, the low-energy MS/MS measurements using MALDI-QIT-ToF, showed hydroxyl-, vinyl- and formyl- terminated fragments with or without other fragment groups, but not distonic cations. The fragmentation depended on the types of polyethers examined. MS/MS measurements using MALDI-QIT-ToF are expected to allow structural characterization of unknown components of polyethers. 相似文献
2.
Darsow KH Lange HA Resch M Walter C Buchholz R 《Rapid communications in mass spectrometry : RCM》2007,21(14):2188-2194
Matrix-assisted laser desorption/ionization (MALDI) time-of-flight (ToF) mass spectrometry (MS) is an established tool for analyzing high mass molecules, such as proteins, whereas it attracts far less interest in the field of lipid analysis. In the study reported here a new chlorosulfolipid (CSL), 3,8,12,15-tetrachloroeicosane-1,17,18-triyl tris(hydrogen sulfate), was identified from the alga Ochromonas danica and de novo characterized by matrix-assisted laser desorption/ionization quadrupole ion trap time-of-flight (MALDI-QIT-ToF) MS in negative ion mode. This method provides an effective alternative for the analysis of compounds directly derived from organic cell extracts. For MALDI analyses several frequently used solid MALDI matrices as well as some ionic liquid matrices (ILMs) were tested to enhance the analyte response to UV-laser and its ionization. The molecular weight of the observed compound could be determined as Li-, Na- and K-adducts [M+Me-2H]-. The characteristic isotopic patterns of the measured ions and the well-allocated molecular fragments by MS1, MS2 and MS3 indicate the fourfold chlorination and threefold sulfation of the investigated compound. The MS fragmentation alongside of the chlorine-bearing C-atoms is accompanied by the generation of a double bond at the opposite fragment in MS1. This obtained fragmentation pattern provides an insight into the allocation of the chlorine-bearing C-atoms along the carbon chain. 相似文献
3.
Phosphopeptide detection and sequencing by matrix-assisted laser desorption/ionization quadrupole time-of-flight tandem mass spectrometry 总被引:5,自引:0,他引:5
Bennett KL Stensballe A Podtelejnikov AV Moniatte M Jensen ON 《Journal of mass spectrometry : JMS》2002,37(2):179-190
A prototype matrix-assisted laser desorption/ionization quadrupole time-of-flight (MALDI-TOF) tandem mass spectrometer was used to sequence a series of phosphotyrosine-, phosphothreonine- and phosphoserine-containing peptides. The high mass resolution and mass accuracy of the instrument allowed the localization of one, three or four phosphorylated amino acid residues in phosphopeptides up to 3.1 kDa. Tandem mass spectra of two different phosphotyrosine peptides permitted amino acid sequence determination and localization of one and three phosphorylation sites, respectively. The phosphotyrosine immonium ion at m/z 216.04 was observed in these MALDI low-energy CID tandem mass spectra. Elimination of phosphate groups was evident from the triphosphorylated peptide but not from the monophosphorylated species. The main fragmentation pathway for the synthetic phosphothreonine-containing peptide and for phosphoserine-containing peptides derived from beta-casein and ovalbumin was the beta-elimination of phosphoric acid with concomitant conversion of phosphoserine to dehydroalanine and phosphothreonine to 2-aminodehydrobutyric acid. Peptide fragment ions of the b- and y-type allowed, in all cases, the localization of phosphorylation sites. Ion signals corresponding to (b-17), (b-18) and (y-17) fragment ions were also observed. The abundant neutral loss of phosphoric acid (-98 Da) is useful for femtomole level detection of phosphoserine-peptides in crude peptide mixtures generated by gel in situ digestion of phosphoproteins. 相似文献
4.
We have acquired multi-stage mass spectra (MSn) of four branched N-glycans derived from human serum IgG by matrix-assisted laser desorption/ionization quadrupole ion trap time-of-flight mass spectrometry (MALDI-QIT-TOF-MS) in order to demonstrate high sensitivity structural analysis. [M+H]+ and [M+Na]+ ions were detected in the positive mode. The detection limit of [M+Na]+ in MS/MS and MS3 measurements for structural analysis was found to be 100 fmol, better than that for [M+H]+. The [M+H]+ ions subsequently fragmented to produce predominantly a Y series of fragments, whereas [M+Na]+ ions fragmented to give a complex mixture of B and Y ions together with some cross-ring fragments. Three features of MALDI-QIT-CID fragmentation of [M+Na]+ were cleared by the analysis of MS/MS, MS3 and MS4 spectra: (1) the fragment ions resulting from the breaking of a bond are more easily generated than that from multi-bond dissociation; (2) the trimannosyl-chitobiose core is either hardly dissociated, easily ionized or it is easy to break a bond between N-acetylglucosamine and mannose; (3) the fragmentation by loss of only galactose from the non-reducing terminus is not observed. We could determine the existence ratios of candidates for each fragment ion in the MS/MS spectrum of [M+Na]+ by considering these features. These results indicate that MSn analysis of [M+Na]+ ions is more useful for the analysis of complicated oligosaccharide structures than MS/MS analysis of [M+H]+, owing to the higher sensitivity and enhanced structural information. Furthermore, two kinds of glycans, with differing branch structures, could be distinguished by comparing the relative fragment ion abundances in the MS3 spectrum of [M+Na]+. These analyses demonstrate that the MSn technology incorporated in MALDI-QIT-TOF-MS can facilitate the elucidation of structure of complex branched oligosaccharides. 相似文献
5.
Demelbauer UM Zehl M Plematl A Allmaier G Rizzi A 《Rapid communications in mass spectrometry : RCM》2004,18(14):1575-1582
Multistage mass spectrometry, as implemented using low-energy collision-induced dissociation (CID) analysis in three-dimensional (3D) quadrupole ion traps (QITs), has become a powerful tool for the investigation of protein glycosylation. In addition to the well-known combination of QITs with electrospray ionization (ESI), also a matrix-assisted laser desorption/ionization--quadrupole ion trap--reflectron time-of-flight (MALDI-QIT-rTOF) mass spectrometer has recently become available. This study systematically investigates the differences between these types of instrument, as applied to characterization of glycopeptides from human antithrombin. The glycopeptides were obtained by tryptic digestion followed by lectin-affinity purification. Some significant differences between the ESI-QIT and MALDI-QIT-rTOF approaches appeared, most of them are causally related to the desorption/ionization process. The combination of a vacuum MALDI source with an ion-trap analyzer accentuates some characteristic differences between MALDI and ESI due the longer time frame needed for the trapping process. In contrast to ESI, MALDI generated ions that exhibited considerable metastable fragmentation during trapping. The long time span of the QIT process (ms range) compared with that for conventional rTOF experiments (micros range) significantly magnified the extent of this metastable fragmentation. With the investigated glycopeptides, a complete depletion of the terminal sialic acids of the glycopeptides as well as a variety of other fragment ions was already found in the MS1 spectra from the MALDI-QIT-rTOF instrument. The positive ion low-energy CID spectra (MS2) of the selected glycopeptides obtained using the two different QIT equipped instruments were found to be quite similar. In both approaches, fragmentation of the glycan and peptide structures occurred sequentially, allowing unambiguous sequence determination. In the case of ESI-QIT-MS, fragmentation of the glycan structure occurred at the MS2 stage and fragmentation of the peptide structure was obtained only at the MS3 stage, which indicates the necessity of multistage CID experiments for complete structure elucidation. The MALDI-QIT-rTOF instrument yielded both kinds of fragments at the MS2 stage but without mutual interference. 相似文献
6.
Salplachta J Marchetti M Chmelík J Allmaier G 《Rapid communications in mass spectrometry : RCM》2005,19(18):2725-2728
7.
Unterieser I Cuers J Voiges K Enebro J Mischnick P 《Rapid communications in mass spectrometry : RCM》2011,25(15):2201-2208
Mass spectrometry is widely applied in carbohydrate analysis, but still quantitative evaluation of data is critical due to different ionization efficiencies of the constituents in a mixture. Different size and chemical structure of the analytes cause their uneven distribution in droplets (electrospray ionization, ESI) or matrix spots (matrix-assisted laser desorption/ionization, MALDI). In addition, instrumental parameters affect final ion yields. In order to study and optimize the latter, an equimolar mixture of malto-oligosaccharides (DP1-6) was analyzed using varying target masses for ESI as well as different matrices and laser power for MALDI. The sodium adducts and derivatives for positive ion mode (hydrazones with Girard's T Reagent, GT) and negative ion mode (reductively aminated with o-aminobenzoic acid, oABA) were studied. Negatively charged oABA-labeled malto-oligosaccharides turned out to be unsuitable for quantification of the malto-oligomeric composition. Best agreement was achieved when applying target masses in the range of the highest homolog in the mixture in electrospray ionization ion trap (ESI-IT) (1-2% deviation with GT label or as Na(+) adducts). Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) gave best results when the laser power was adjusted significantly over the desorption/ionization threshold (1% deviation with GT label). Both parameters show significant influence on the determined oligomeric composition. Consequently, estimation and even quantitative determination of amounts of oligosaccharides in a mixture can be achieved when the analytes are labeled and the proper instrumental parameters are used. 相似文献
8.
Gregorius B Schaumlöffel D Hildebrandt A Tholey A 《Rapid communications in mass spectrometry : RCM》2010,24(22):3279-3289
Metal labelling of peptides and proteins using high-affinity metal-chelating compounds has found widespread applications in the medical and bioanalytical fields. In the present study we investigated the analysis of peptides derivatized either with cysteine- or amino group-directed metal-bound DOTA (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid) chelators in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). The metal complexes of DOTA were shown to be stable under MALDI-MS conditions. The introduction of the metal label led in a number of cases to significantly increased signal-to-noise (S/N) values and thus improved sensitivity of the labelled peptides compared to their unlabelled counterparts, especially for multiply labelled peptides. The presence of the labels did alter the tandem mass spectrometric (MS/MS) behaviour, namely the formation of sequence specific a-, b- and y-ion series, in dependence of the position of the label within the peptide sequence. For cysteine-derivatized peptides several label-specific reporter ions and characteristic immonium ions could be identified. Amino-directed labelling led only to the formation of characteristic immonium ions in ε-amino groups of lysine, whereas N-terminal labelling in some cases led to the formation of a(1)- and b(1)-ions. The results clearly show that MALDI-MS is suitable for the analysis of metal-labelled peptides, which was also confirmed in liquid chromatography (LC)/MALDI-based identification of proteins in a model protein mixture labelled with Cys-reactive DOTA. Here, in comparison to a run with alkylated cysteines, more than 50% more cysteine-containing peptides were identified. 相似文献
9.
Bacher G Körner R Atrih A Foster SJ Roepstorff P Allmaier G 《Journal of mass spectrometry : JMS》2001,36(2):124-139
A general approach for the detailed characterization of sodium borohydride-reduced peptidoglycan fragments (syn. muropeptides), produced by muramidase digestion of the purified sacculus isolated from Bacillus subtilis (vegetative cell form of the wild type and a dacA mutant) and Bacillus megaterium (endospore form), is outlined based on UV matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) and nano-electrospray ionization (nESI) quadrupole ion trap (QIT) mass spectrometry (MS). After enzymatic digestion and reduction of the resulting muropeptides, the complex glycopeptide mixture was separated and fractionated by reversed-phase high-performance liquid chromatography. Prior to mass spectrometric analysis, the muropeptide samples were subjected to a desalting step and an aliquot was taken for amino acid analysis. Initial molecular mass determination of these peptidoglycan fragments (ranging from monomeric to tetrameric muropeptides) was performed by positive and negative ion MALDI-MS using the thin-layer technique with the matrix alpha-cyano-4-hydroxycinnamic acid. The results demonstrated that for the fast molecular mass determination of large sample numbers in the 0.8-10 pmol range and with a mass accuracy of +/-0.07%, negative ion MALDI-MS in the linear TOF mode is the method of choice. After this kind of muropeptide screening often a detailed primary structural analysis is required owing to ambiguous data. Structural data could be obtained from peptidoglycan monomers by post-source decay (PSD) fragment ion analysis, but not from dimers or higher oligomers and not with the necessary sensitivity. Multistage collision-induced dissociation (CID) experiments performed on an nESI-QIT instrument were found to be the superior method for structural characterization of not only monomeric but also of dimeric and trimeric muropeptides. Up to MS4 experiments were sometimes necessary to obtain unambiguous structural information. Three examples are presented: (a) CID MSn (n = 2-4) of a peptidoglycan monomer (disaccharide-tripeptide) isolated from B. subtilis (wild type, vegetative cell form), (b) CID MSn (n = 2-4) of a peptidoglycan dimer (bis-disaccharide-tetrapentapeptide) obtained from a B. subtilis mutant (vegetative cell form) and (c) CID MS2 of a peptidoglycan trimer (a linear hexasaccharide with two peptide side chains) isolated from the spore cortex of B. megaterium. All MS(n) experiments were performed on singly charged precursor ions and the MS2 spectra were dominated by fragments derived from interglycosidic bond cleavages. MS3 and MS4 spectra exhibited mainly peptide moiety fragment ions. In case of the bis-disaccharide-tetrapentapeptide, the peptide branching point could be determined based on MS3 and MS4 spectra. The results demonstrate the utility of nESI-QIT-MS towards the facile determination of the glycan sequence, the peptide linkage and the peptide sequence and branching of purified muropeptides (monomeric up to trimeric forms). The wealth of structural information generated by nESI-QIT-MSn is unsurpassed by any other individual technique. 相似文献
10.
Organic secondary ion mass spectrometry (SIMS) and matrix-assisted laser desorption/ionization (MALDI) mass spectrometry can be used to produce molecular images of samples. This is achieved through ionization from a clearly identified point on a flat sample, and performing a raster of the sample by moving the point of ionization over the sample surface. The unique analytical capabilities of mass spectrometry for mapping a variety of biological samples at the tissue level are discussed. SIMS provides information on the spatial distribution of the elements and low molecular mass compounds as well as molecular structures on these compounds, while MALDI yields spatial information about higher molecular mass compounds, including their distributions in tissues at very low levels, as well as information on the molecular structures of these compounds. Application of these methods to analytical problems requires appropriate instrumentation, sample preparation methodology, and a data presentation usually in a three-coordinate plot where x and y are physical dimensions of the sample and z is the signal amplitude. The use of imaging mass spectrometry is illustrated with several biological systems. 相似文献
11.
Colin S Creaser James C Reynolds David J Harvey 《Rapid communications in mass spectrometry : RCM》2002,16(3):176-184
An ion source incorporating a fibre optic interface has been constructed for atmospheric pressure matrix-assisted laser desorption/ionisation quadrupole ion trap mass spectrometry. The configuration has been applied to the study of linear and complex oligosaccharides. Multi-stage tandem mass spectrometry (MSn, n = 2-4) experiments carried out in the ion trap enable extended fragmentation pathways to be investigated that yield structural information. Collisional activation of sodiated oligosaccharides, as demonstrated on the model compound maltoheptaose, produces primarily B and Y fragments resulting from cleavage of glycosidic bonds; fragments from cross-ring cleavages are also observed following further stages of tandem mass spectrometry, providing additional linkage information. The analyses of mixtures of complex oligosaccharides are demonstrated for N-linked glycans from chicken egg glycoproteins and a ribonuclease glycan mixture. Mass spectrometric and tandem mass spectrometric data for sugars with molecular weights up to 4000 Da is shown for mixtures of linear dextrans and N-linked glycans. The use of MSn (n = 3, 4) on these complex molecules enabled structural information to be elucidated that confirms data observed in the MS/MS spectra. 相似文献
12.
Lin M Campbell JM Mueller DR Wirth U 《Rapid communications in mass spectrometry : RCM》2003,17(16):1809-1814
Direct tandem mass spectrometric (MS/MS) analysis of small, singly charged protein ions by tandem time-of-flight mass spectrometry (TOFMS) is demonstrated for proteins up to a molecular mass of 12 kDa. The MALDI-generated singly charged precursor ions predominantly yield product ions resulting from metastable fragmentation at aspartyl and prolyl residues. Additional series of C-terminal sequence ions provide in some cases sufficient information for protein identification. The amount of sample required to obtain good quality spectra is in the high femtomolar to low picomolar range. Within this range, MALDI-MS/MS using TOF/TOF trade mark ion optics now provides the opportunity for direct protein identification and partial characterization without prior enzymatic hydrolysis. 相似文献
13.
Schlosser G Pocsfalvi G Malorni A Puerta A de Frutos M Vékey K 《Rapid communications in mass spectrometry : RCM》2003,17(24):2741-2747
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) was used to detect an immune complex formed between beta-lactoglobulin and polyclonal anti-beta-lactoglobulin antibody in the gas phase. The most important experimental parameters to detect such a specific antibody-antigen complex by MALDI were the use of solutions at near-neutral pH and of sinapinic acid matrix prepared by the dried-droplet method. Under such conditions, predominantly one but also two molecules of antigen protein were complexed by the antibody. Specific formation of the antibody-antigen complex was confirmed by performing competitive reactions. Addition of antibody to a 1:1 mixture of beta-lactoglobulin and one control protein resulted not only in the appearance of the expected antibody-antigen complex, but also in a strong decrease in the free beta-lactoglobulin signal, while the abundance of the control protein was not influenced. 相似文献
14.
Yamada Y Hidefumi K Shion H Oshikata M Haramaki Y 《Rapid communications in mass spectrometry : RCM》2011,25(11):1600-1608
In pharmacology and toxicology, localization of the distribution of a drug molecule in its target tissue provides very important in vivo biological information. Traditionally, this has been examined using autoradiography (ARG). However, there are significant limitations in this application. One is the synthesis and use of radiolabeled compounds, the other is that the image generated expresses an undifferentiated mixture of the parent drug and/or its metabolites. The objective of the study was to define the specific distribution of the parent drug in rat ocular tissue containing melanin (e.g. the retina) using non‐labeled chloroquine by MALDI Imaging tandem mass spectrometry (MS/MS). After single oral administration (at 20 mg/kg) of chloroquine, sections (10 µm) of rat eye tissue were prepared at 24 h. The MS system used was a quadrupole time‐of flight (Q‐TOF) tandem mass spectrometer (MALDI Synapt?, Waters, Milford, MA, USA). Tissue sections were sprayed with CHCA (α‐cyano‐4‐hydroxycinnamic acid, 5 mg/mL) in 80% acetonitrile (ACN) containing 5% formic acid (FA) using either a manual sprayer (airbrush) or an automated sprayer (TM‐Sprayer?, HTX Technologies, Carrboro, NC, USA). Chloroquine was readily detected in the MS/MS mode by monitoring one of its major fragment ions (m/z 247.10) and imaged through the rat eye tissue. The image of the specific distribution within the retina in the rat eye tissue was confirmed, and found to be similar to autoradiograms after oral administration of 14C‐chloroquine reported previously. Copyright © 2011 John Wiley & Sons, Ltd. 相似文献
15.
A. A. Sorokin V. P. Gar’kin N. S. Red’kin A. K. Buryak 《Russian Journal of Applied Chemistry》2010,83(12):2163-2167
Various types of ionization of organotellurium compounds in mass-spectrometric study are considered, with diphenyl telluroxide
as example. The mass spectra of diphenyl telluroxide are presented. The possibility of applying surface-activated and matrix-assisted
laser desorption/ionization mass spectrometry to organotellurium compounds is examined. 相似文献
16.
Zeng R Chen YB Shao XX Shieh CH Miller K Tran H Xia QC 《Rapid communications in mass spectrometry : RCM》2003,17(17):1995-2004
Digests from ten gel bands containing low abundance proteins were analyzed by both matrix-assisted laser desorption/ionization ion trap (MALDI-IT) and matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) methods. MALDI-TOF techniques were able to identify only one protein from all 10 gel bands, while MALDI-IT identified eight proteins from the same 10 bands. The ability to perform MS/MS experiments with a MALDI-IT instrument leads to protein identifications based on both peptide molecular mass and sequence information, and is much less prone to errors and uncertainties introduced by peptide fingerprinting methodologies in which protein identification is based on peptide molecular masses alone. 相似文献
17.
Qiao Z Udeochu U Jimerson T Fletcher M Bakare O Hosten CM 《Rapid communications in mass spectrometry : RCM》2006,20(3):487-492
A method for the detection of BPDE-d guanosine adducts using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) is described and illustrated. The results indicate that MALDI is capable of detecting two other DNA benzopyrene adducts, which are trace products formed during the synthesis of BPDE-d guanosine. This MALDI-TOFMS method offers the potential for the detection of DNA adducts in human tissue using very limited sample purification and preparation. 相似文献
18.
Creaser CS Reynolds JC Hoteling AJ Nichols WF Owens KG 《European journal of mass spectrometry (Chichester, England)》2003,9(1):33-44
Atmospheric pressure matrix-assisted laser desorption/ionisation quadrupole ion trap (AP-MALDI/QIT) mass spectrometry has been investigated for the analysis of polyethylene glycol (PEG 1500) and a hyperbranched polymer (polyglycidol) in the presence of alkali-metal salts. Mass spectra of PEG 1500 obtained at atmospheric pressure showed dimetallated matrix/analyte adducts, in addition to the expected alkali-metal/PEG ions, for all matrix/alkali-metal salt combinations. The relative intensities of the desorbed ions were dependent on the matrix, the alkali-metal salt added to aid cationisation and the ion trap interface conditions [capillary temperature, in-source collisionally-induced dissociation (CID)]. These data indicate that the adducts are rapidly stabilised by collisional cooling enabling them to be transferred into the ion trap. Experiments using identical sample preparation conditions were carried out on a vacuum MALDI time-of-flight (ToF) mass spectrometer. In all cases, vacuum MALDI-ToF spectra showed only alkali-metal/PEG ions and no matrix/analyte adducts. The tandem mass spectrometry (MS/MS) capability of the ion trap has been demonstrated for a lithiated polyglycol yielding a rich fragment-ion spectrum. Analysis of the hyperbranched polymer polyglycidol by AP-MALDI/QIT reveals the characteristic ion series for these polymers as also observed under vacuum MALDI-ToF conditions. 相似文献
19.
Simple, rapid and inexpensive one-step reverse micellar microextraction (RMME) procedures were combined with matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) for the determination of thiol-containing peptides and amino acids. In this investigation, a thiol-containing peptide (HW6) was chosen as model compound to understand the mechanism of RMME. The electrostatic interactions between the thiol-containing peptide and reverse micelles were proposed to be reason for the transfer of analytes from the aqueous phase to the organic phase. Reverse micelles were formed by the cationic surfactant, methyltrioctylammonium chloride (MTOAC). The best extraction efficiency of HW6 was obtained under the following conditions: pH 11.0, ionic strength 5.0 mM of KCl and micelle concentration 7.0 mM of MTOAC. The limits of detection (LODs) obtained for HW6 in water, urine and plasma samples were 0.15, 0.19 and 0.28 microM, respectively, with relative standard deviation (RSD) values in the range +/-8.8-10.5%. The sensitivity obtained in water by the present method was 45-fold higher than that of the conventional use of atmospheric-pressure (AP)-MALDI MS. Furthermore, the applicability of the proposed approach was extended for the determination of thiol-containing amino acids in sample solutions by using MALDI time-of-flight (TOF) MS. 相似文献
20.
Harvey DJ Martin RL Jackson KA Sutton CW 《Rapid communications in mass spectrometry : RCM》2004,18(24):2997-3007
N-Linked glycans were ionized from several matrices with a Shimadzu-Biotech AXIMA-QIT matrix-assisted laser desorption/ionization quadrupole ion trap time-of-flight mass spectrometer. [M+Na]+ ions were produced from all matrices and were accompanied by varying amounts of in-source fragmentation products. The least fragmentation was produced by 2,5-dihydroxybenzoic acid and the most by alpha-cyano-4-hydroxycinnamic acid and 6-aza-2-thiothymine. Sialic acid loss was extensive but could be prevented by formation of methyl esters. Fragmentation produced typical low-energy-type spectra dominated by ions formed by glycosidic cleavages. MS(n) spectra (n = 3 and 4) were used to probe the pathways leading to the major diagnostic ions. Thus, for example, an ion that was formed by loss of the core GlcNAc residues and the 3-antenna was confirmed as being formed by a B/Y rather than a C/Z mechanism. The proposed structures of several cross-ring cleavage ions were confirmed and it was shown that MS3 spectra could be obtained from as little as 10 fmol of glycan. 相似文献