首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We report the direct excitation of the highly forbidden (6s2) 1S0 <--> (6s6p) 3P0 optical transition in two odd isotopes of neutral ytterbium. As the excitation laser frequency is scanned, absorption is detected by monitoring the depletion from an atomic cloud at approximately 70 microK in a magneto-optical trap. The measured frequency in 171Yb (F=1/2) is 518,295,836,591.6 +/- 4.4 kHz. The measured frequency in 173Yb (F=5/2) is 518,294,576,847.6 +/- 4.4 kHz. Measurements are made with a femtosecond-laser frequency comb calibrated by the National Institute of Standards and Technology cesium fountain clock and represent nearly a 10(6)-fold reduction in uncertainty. The natural linewidth of these J=0 to J=0 transitions is calculated to be approximately 10 mHz, making them well suited to support a new generation of optical atomic clocks based on confinement in an optical lattice.  相似文献   

2.
Spectroscopy of the 1S0-3P0 clock transition of 87Sr in an optical lattice   总被引:1,自引:0,他引:1  
We report on the spectroscopy of the 5s(2) 1S0(F=9/2)-->5s5p 3P0(F=9/2) clock transition of 87Sr atoms (natural linewidth of 1 mHz) trapped in a one-dimensional optical lattice. Recoilless transitions with a linewidth of 0.7 kHz as well as the vibrational structure of the lattice potential were observed. By investigating the wavelength dependence of the carrier linewidth, we determined the magic wavelength, where the light shift in the clock transition vanishes, to be 813.5+/-0.9 nm.  相似文献   

3.
We have developed a practical and precise frequency measurement system at 1.5 μm telecommunication band. An electro-optic-modulator based optical frequency comb is phase-locked to a dither-free acetylene-stabilized laser to realize an optical frequency comb with frequency uncertainty of 10 kHz (5 × 10−11) and the linewidth of 15 kHz. The present frequency comb can be also used as an optical frequency reference grid defined by ITU-T (International Telecommunication Union, Telecommunication Standardization Sector). Using the present frequency measurement system, we have demonstrated the first optical frequency measurement of 12C16O overtone absorption lines around 1.56 μm with the uncertainty of lower than 900 kHz.  相似文献   

4.
An all-fibre optical system for optical interrogation and detection of the vibrations of a silicon microresonator is reported. Metal-coated silicon microresonators are excited by intensity modulated laser light delivered through an optical fibre, while the vibration of the resonators is detected by an optical fibre interferometer. Measurements have shown that an average optical power of 10 μW is sufficient to maintain the flexural vibration of the resonator. When the resonator is used as a pressure sensor, its resonant frequency changes from 62 kHz to 130 kHz as the pressure varies from -0°6 bar to 1 bar (gauge). A silicon resonator with 700 nm aluminium coating functions as a temperature sensor, showing a frequency shift from 262 kHz to 251 kHz when the temperature changes from 25 °C to 80 °C.  相似文献   

5.
A high-resolution spectroscopy technique is proposed with an optical phase modulator combined with an interleaved optical frequency comb. The optical phase modulator and a frequency-locked laser light guarantee a spectral resolution less than 1 MHz on an absolute frequency axis. A wide measurement frequency range was realized using a 25 GHz optical frequency comb lying over a 4 THz frequency region. An extraction of single tooth intensity from the comb was realized by a heterodyne technique with a frequency-tunable laser used as a local oscillator. Also, the 25 GHz optical frequency comb was interleaved to generate four 100-GHz combs for removing the crosstalk from the 25 GHz neighboring sidebands in the teeth. This proposed spectroscopy technique was experimentally demonstrated with a resonator of less than 1 MHz linewidth and a H13C14N gas cell. Thus, a measurement frequency range higher than 4 THz (1530 nm-1560 nm) was confirmed with an effective spectral resolution 100 kHz order. In addition, the characteristics of the proposed system were compared with those of the previous system with a single-sideband (SSB) optical modulator.  相似文献   

6.
We measure the frequency of the 5s21S0-5s5p 3P0 narrowline clock transition at 236.5 nm, for a single, trapped and laser cooled 115In+ ion. In the experiment, an ultra-narrow linewidth laser (<1.34 Hz at 3 s integration time) is used to interrogate the clock transition for high resolution spectroscopy. A linewidth of 43 Hz of the clock transition is observed. The uncertainty of the line centroid is 18 Hz, leading to a fractional uncertainty of 1.4×10-14. The frequency is measured by using an optical frequency comb referenced to a cesium clock. The transition frequency is found to be 1, 267, 402, 452, 901.265 (256) kHz, averaged over 13 days of separate measurement. The accuracy of 2.35×10-13 is due to the reference cesium clock calibrated against UTC time. We discuss ways for further improvements.  相似文献   

7.
Using an iodine-stabilized He-Ne laser as a transfer oscillator, we compare absolute measurements of the optical frequency from a traditional frequency synthesis chain based on harmonic generation and from the frequency division technique of an ultrawide bandwidth femtosecond frequency comb. The agreement between these two measurements, both linked to the Cs standard, is 220+/-770 Hz, yielding a measurement accuracy of 1.6x10(-12). We report 473 612 353 604.8+/-1.2 kHz as a preliminary updated value of the absolute frequency of the " f" component for the He-Ne laser international standard at 633 nm.  相似文献   

8.
A pair of 1.5 μm semiconductor laser frequency standards have been developed for optical telecommunications use, stabilised to transitions of 12C2H2 and 13C2H2, using cavity-enhanced Doppler-free saturation absorption spectroscopy. The absolute frequencies of 41 lines of the ν1 + ν3 band of 12C2H2, covering the spectral region 1520-1545 nm, have been measured by use of a passive optical frequency comb generator, referenced to 13C2H2 transitions of known frequency. The mean experimental uncertainties (coverage factor k = 1) of the frequency values are 3.0 kHz (type A) and 10 kHz (type B). Improved values of the band origin ν0, rotational constants B′ and B″, and centrifugal distortion coefficients D′, D″, H′, and H″ are presented.  相似文献   

9.
Q. Liu  H. Chen  X. Yan  M. Gong 《Optics Communications》2011,284(13):3383-3386
A high power, high beam quality, compact green laser based on dual-rod AO Q-switched resonator was designed, fabricated and tested. The laser provided a maximum 532 nm average power of 36.5 W at a repetition rate of 65 kHz with the beam quality factor of M2 = 1.55 and the optical frequency conversion efficiency from NIR to green laser was as high as 51%. The pulse repetition rate was tunable from 50 kHz to 200 kHz and the overall dimension of the laser was within 500 × 300 × 150 mm3.  相似文献   

10.
We report the frequency measurement with an accuracy in the 100 kHz range of several optical transitions of atomic Sr: 1S0-3P1 at 689 nm, 3P1-3S1 at 688 nm and 3P0-3S1 at 679 nm. Measurements are performed with a frequency chain based on a femtosecond laser referenced to primary frequency standards. They allowed the indirect determination with a 70 kHz uncertainty of the frequency of the doubly forbidden transition of 87Sr at 698 nm and in a second step its direct observation. Frequency measurements are performed for 88Sr and 87Sr, allowing the determination of 3P0, 3P1 and 3S1 isotope shifts, as well as the 3S1 hyperfine constants.  相似文献   

11.
We report the observation of Bs(0)-Bs(0) oscillations from a time-dependent measurement of the Bs(0)-Bs(0) oscillation frequency Deltams. Using a data sample of 1 fb(-1) of pp collisions at square root of s=1.96 TeV collected with the CDF II detector at the Fermilab Tevatron, we find signals of 5600 fully reconstructed hadronic Bs decays, 3100 partially reconstructed hadronic Bs decays, and 61,500 partially reconstructed semileptonic Bs decays. We measure the probability as a function of proper decay time that the Bs decays with the same, or opposite, flavor as the flavor at production, and we find a signal for Bs(0)-Bs(0) oscillations. The probability that random fluctuations could produce a comparable signal is 8 x 10(-8), which exceeds 5sigma significance. We measure Deltams=17.77 +/- 0.10(stat) +/- 0.07(syst) ps(-1) and extract /V(td)/V(ts)/=0.2060+/-0.0007(Deltams)(-0.0060)(+0.008)(Deltamd+theor).  相似文献   

12.
Hearing thresholds as a function of sound-source azimuth were measured in bottlenose dolphins using an auditory evoked potential (AEP) technique. AEP recording from a region next to the ear allowed recording monaural responses. Thus, a monaural directivity diagram (a threshold-vs-azimuth function) was obtained. For comparison, binaural AEP components were recorded from the vertex to get standard binaural directivity diagrams. Both monaural and binaural diagrams were obtained at frequencies ranging from 8 to 128 kHz in quarter-octave steps. At all frequencies, the monaural diagram demonstrated asymmetry manifesting itself as: (1) lower thresholds at the ipsilateral azimuth as compared to the symmetrical contralateral azimuth and (2) ipsilateral shift of the lowest-threshold point. The directivity index increased with frequency: at the ipsilateral side it rose from 4.7 to 17.8 dB from 11.2 to 128 kHz, and from 10.5 to 15.6 dB at the contralateral side. The lowest-threshold azimuth shifted from 0 degrees at 90-128 kHz to 22.5 degrees at 8-11.2 kHz. The frequency-dependent variation of the lowest-threshold azimuth indicates the presence of two sound-receiving apertures at each head side: a high-frequency aperture with the axis directed frontally, and a low-frequency aperture with the axis directed laterally.  相似文献   

13.
We report an observation of the weak 6 1S0-6 3P0 transition in (171,173)Yb as an important step to establishing Yb as a primary candidate for future optical frequency standards, and to open up a new approach for qubits using the 1S0 and 3P0 states of Yb atoms in an optical lattice.  相似文献   

14.
The 1S0-3P0 clock transition frequency nuSr in neutral 87Sr has been measured relative to the Cs standard by three independent laboratories in Boulder, Paris, and Tokyo over the last three years. The agreement on the 1 x 10(-15) level makes nuSr the best agreed-upon optical atomic frequency. We combine periodic variations in the 87Sr clock frequency with 199Hg+ and H-maser data to test local position invariance by obtaining the strongest limits to date on gravitational-coupling coefficients for the fine-structure constant alpha, electron-proton mass ratio mu, and light quark mass. Furthermore, after 199Hg+, 171Yb+, and H, we add 87Sr as the fourth optical atomic clock species to enhance constraints on yearly drifts of alpha and mu.  相似文献   

15.
Diode end-pumped continuous-wave and passively Q-switched Nd:Lux(x = 0.5)Y1 − xVO4 mixed crystal lasers were demonstrated. At the pump power of 12.6 W, the maximum output power of 6.7 W around 1066.5 nm was obtained with the output transmission of 27%. The optical conversion efficiency is 53.2%, corresponding to a slope efficiency of 55.8%. For pulsed operation, the shortest pulse width attained was 8.6 ns, with the pulse repetition frequency of 99 kHz, and the single pulse energy and the peak power were estimated to be 25.5 μJ and 2.96 kW, respectively.  相似文献   

16.
The performances of two Laser Doppler Velocimetry (LDV) systems adapted for measuring the acoustic particle velocities are assessed in enclosed sound field. This assessment is performed by comparing the acoustic velocities measured by means of LDV to reference acoustic velocities estimated from sound pressure measurements. The two LDV systems are based on a single optical bench which delivers an optical signal called Doppler signal. The Doppler signal, which is frequency modulated, is analyzed by means of two signal processing systems, the BSA (Burst Spectrum Analyser from Dantec) on the one hand, and a system specifically developed for the estimation of the acoustic velocity on the other hand. Once the experimental setup has been optimized for minimizing the errors made on the reference velocities, the assessment is performed and shows that both systems can measure the acoustic velocity in enclosed field in two the frequency ranges [0-4 kHz] and [0-2 kHz] respectively for acoustic velocity amplitudes of 10 mm/s and 1 mm/s.  相似文献   

17.
Cranch GA 《Optics letters》2002,27(13):1114-1116
A novel technique for suppressing frequency noise in an erbium-doped fiber distributed-feedback laser incorporated into a master-oscillator-power-amplifier configuration by an electronic feedback technique is presented. The frequency noise is suppressed by locking of the laser emission to a fiber interferometer. The frequency noise spectral density of the laser is reduced by as much as 20 dB over the frequency range 1 Hz-10 kHz to 1.5 Hz/Hz(1/2) +/-25% at 1 kHz with a relative intensity noise spectral density below -120 dB/Hz over the frequency range 10 Hz-1 kHz. These lasers will have applications as sources for fiber-optic interferometry, high-resolution spectroscopy, and high-bandwidth communications.  相似文献   

18.
Flavor oscillations of neutral B mesons have been studied in e+e- annihilation data collected with the BABAR detector at center-of-mass energies near the upsilon(4S) resonance. The data sample used for this purpose consists of events in which one B0 meson is reconstructed in a hadronic decay mode, while the flavor of the recoiling B0 is determined with a tagging algorithm that exploits the correlation between the flavor of the heavy quark and the charges of its decay products. From the time development of the observed mixed and unmixed final states, we determine the B0-B-0 oscillation frequency deltamd to be 0.516+/-0.016(stat)+/-0.010(syst) ps-1.  相似文献   

19.
We have remeasured the absolute 1S-2S transition frequency nu(H) in atomic hydrogen. A comparison with the result of the previous measurement performed in 1999 sets a limit of (-29+/-57) Hz for the drift of nu(H) with respect to the ground state hyperfine splitting nu(Cs) in 133Cs. Combining this result with the recently published optical transition frequency in 199Hg+ against nu(Cs) and a microwave 87Rb and 133Cs clock comparison, we deduce separate limits on alpha/alpha=(-0.9+/-2.9) x 10(-15) yr(-1) and the fractional time variation of the ratio of Rb and Cs nuclear magnetic moments mu(Rb)/mu(Cs) equal to (-0.5+/-1.7) x 10(-15) yr(-1). The latter provides information on the temporal behavior of the constant of strong interaction.  相似文献   

20.
The absolute frequencies of 20 lines of the 2-0 band of CO near 4260 cm?1 have been measured by heterodyne frequency measurement techniques. Eleven of the lines were measured by saturated absorption techniques which produced linewidths of about 3 MHz. New rovibrational constants have been fitted to these measurements. A table of calculated transition frequencies is given with estimated absolute uncertainties as small as 0.0000023 cm?1 (70 kHz) near the band center. The pressure shifts of three lines have been measured and fall in the range from ?0.9 to ?3 kHz/Pa (?122 to ?400 kHz/Torr). It is suggested that the generally accepted frequencies of the 1-0 band of CO should be lowered by 7 MHz.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号