首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
A “micro-electrospray” ionization source has been developed that markedly increases the sensitivity of the conventional electrospray source. This was achieved by optimization of the source to accommodate nanoliter flow rates from 300 to 800-nL/min spraying directly from a capillary needle that, for the analysis of peptides, contained C18 liquid chromatography packing as an integrated concentration-desalting device. Thus, a total of 1 fmol of methionine enkephalin was desorbed from the capillary column spray needle, loaded as a 10-μL injection of 100-amol/μL solution. The mass spectrum showed the [M + H]+ ion at m/z 574.2 with a signal-to-noise ratio of better than 5:1 from a chromatographic peak with a width of about 12 s. A narrow range (15-u) tandem mass spectrum was obtained for methionine enkephalin from the injection of 500 amol, and a full-scan tandem-mass spectrum was obtained from 50 fmol. For proteins, the average mass measurement accuracy was approximately 100–200 ppm for the injection of 2.5 fmol of apomyoglobin and 20–40 ppm for 200 fmol. Carbonic anhydrase B and bovine serum albumin showed similar mass measurement accuracies.  相似文献   

3.
This paper describes experience with the commercially available LCQ quadrupole ion trap mass spectrometer applied to the off-line analysis of peptides and proteins. The standard front end of the electrospray probe was replaced with a micromanipulator which, with the aid of a magnifying device, allowed the use of a variety of miniaturized spraying interfaces. The low sample consumption and extended analysis times of these devices were ideally suitable to obtain improved results in terms of sensitivity and mass accuracy. This needed a careful optimization of the number of ions stored inside the trap (ion target parameter) and required spectrum averaging of many scans. A method is presented for the mathematical fitting of ZoomScan spectra to theoretical isotopic distributions, which allowed the mass determination of large peptides with more accuracy than that achieved by conventional deconvolution algorithms. A very simple on-line desalting configuration is also described which needed no external micro-high-performance liquid chromatographic pumps, and can be easily mounted using the built-in syringe delivery system of the LCQ. This set-up allowed extended analysis times of 'in-gel' protein digests in subpicomole amounts. Finally, the multiple fragmentation capabilities of the ion trap were found to be extremely useful for the analysis of peptide modifications such as phosphorylation and for sequencing individual peptides from highly complex MHC-bound peptide pools.  相似文献   

4.
The research topics and the analytical strategies dealing with food proteins and peptides are summarized. Methods for the separation and purification of macromolecules of food concern by both high-performance liquid chromatography (HPLC) on conventional packings and perfusion HPLC are examined. Special attention is paid to novel methodologies such those based on multi-dimensional systems that comprise liquid-phase based protein separation, protein digestion and mass spectrometry (MS) analysis of food peptide and proteins. Recent applications of chromatography and MS-based techniques for the analysis of proteins and peptides in food are discussed.  相似文献   

5.
At high pH and in the presence of dissolved CO2, the N-terminus and ε-amino groups of amino acids, peptides, and proteins can form carbamino adducts with CO2, R-NH2 + CO2 ↔ R-NHCOO + H+. We report the first study of carbamino group formation by electrospray ionization (ESI) mass spectrometry (MS). Angiotensin II, bradykinin, substance P, and insulin have been studied. A careful optimization of the instrumental parameters was necessary to allow the transfer of the fragile adducts into vacuum for mass analysis. Particularly, dissociation of the adducts in the ion sampling process and pH changes in ESI must be minimized. With these precautions, levels of carbamino group formation of angiotensin II and bradykinin determined from mass spectra agree with those expected to be in solution, calculated from literature equilibrium constants. Thus, ESI MS can quantitatively measure ratios of carbamino adduct to total peptide concentration in solution. Values of equilibrium constants for carbamino group formation with substance P (pKc = 4.77 ± 0.18) and insulin (pKc = 4.99 ± 0.05) are reported for the first time.  相似文献   

6.
The identification and quantification of modified peptides are critical for the functional characterization of post-translational protein modifications (PTMs) to elucidate their biological function. Nowadays, quantitative mass spectrometry coupled with various bioinformatic pipelines has been successfully used for the determination of a wide range of PTMs. However, direct characterization of low abundant protein PTMs in bottom-up proteomic workflow remains challenging. Here, we present the synthesis and evaluation of tandem mass spectrometry tags (TMT) which are introduced via click-chemistry into peptides bearing alkyne handles. The fragmentation properties of the two mass tags were validated and used for screening in a model system and analysis of AMPylated proteins. The presented tags provide a valuable tool for diagnostic peak generation to increase confidence in the identification of modified peptides and potentially for direct peptide-PTM quantification from various experimental conditions.  相似文献   

7.
Ion trap mass spectrometry has been shown to be particularly suitable for the structural analysis of high molecular weight peptides directly fragmented in the mass analyser without needing further sub-digestion reactions. Here we report the advantages of using multi-stage ion trap mass spectrometry in the structural characterisation of haemoglobin alkylated with epichlorohydrin and diepoxybutane. Alkylated globins were digested with trypsin and the peptide mixtures were analysed by MS(3). This technique allows the sequential fragmentation of peptides under analysis, giving rise to MS(3) product ion spectra with additional information with respect to MS(2) mass spectra. The results obtained complete the previously reported structural characterisation of alkylated haemoglobin, demonstrating the potential of ion trap mass spectrometry.  相似文献   

8.
A completely automated procedure for the purification and desalting of proteins with a polyhistidine purification tag prior to mass spectrometry analysis is presented. The system is ideal for rapid quality control and optimization studies and it provides researchers with a straightforward, reliable tool for studies of recombinant proteins. Forty-eight samples can be prepared within 4.5 h and only small cultivation and buffer volumes are needed. In this proof of concept, 19,000–35,000 Da recombinant proteins from both crude and clarified cell lysates were successfully prepared for subsequent analysis by electrospray ionization and matrix-assisted laser desorption/ionization mass spectrometry as well as by gel electrophoresis.  相似文献   

9.
Applications of mass spectrometry to food proteins and peptides   总被引:3,自引:0,他引:3  
The application of mass spectrometry (MS) to large biomolecules has been revolutionized in the past decade with the development of electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) techniques. ESI and MALDI permit solvent evaporation and sublimation of large biomolecules into the gaseous phase, respectively. The coupling of ESI or MALDI to an appropriate mass spectrometer has allowed the determination of accurate molecular mass and the detection of chemical modification at high sensitivity (picomole to femtomole). The interface of mass spectrometry hardware with computers and new extended mass spectrometric methods has resulted in the use of MS for protein sequencing, post-translational modifications, protein conformations (native, denatured, folding intermediates), protein folding/unfolding, and protein-protein or protein-ligand interactions. In this review, applications of MS, particularly ESI-MS and MALDI time-of-flight MS, to food proteins and peptides are described.  相似文献   

10.
A method for rapid characterization of recombinant and modified proteins with known sequences is described. The analytical system consists of a capillary zone electrophoresis (CZE) instrument coupled to an electrospray ionization ion trap tandem mass spectrometer via a sheath-flow interface. Following the procedure consists of proteolytic fragmentation, CZE peptide separation, tandem mass spectrometry (MS-MS) analysis of separated peptides, sequence database search and monitoring of the specific peptides, C 125 S mutated interleukin 2 (S-125-IL2) and bovine beta-casein were characterized as a model of recombinant protein and naturally modified protein, respectively. A tryptic peptide mixture derived from the synthetic salmon calcitonin (s-CT) was also analyzed to test the performance of the system. Although a conventional sheath-flow interface with much higher flow-rate compared to the microspray interface and nanospray interface was used, the proteins were identified at the low picomole level.  相似文献   

11.
12.
13.
14.
15.
Structural analysis of drug-DNA adducts by tandem mass spectrometry   总被引:1,自引:0,他引:1  
The utility of electrospray ionisation (ESI) tandem mass spectrometry (MS/MS) for the characterisation of ligand-oligonucleotide adducts is demonstrated with adducts formed between the oligonucleotide 5'-CACGTG-3' and both a platinating agent, cis-diamminedichloroplatinum(II) (cisplatin), and an alkylating ligand, n-bromohexylphenanthridinium bromide (phenC6Br). We have demonstrated previously that negative ion MS/MS spectra of alkylated oligonucleotides show a highly specific fragmentation pathway that enables the site of binding of the ligand to be readily identified. In comparison, the positive ion ESI-MS/MS spectra reported here also show a single major fragmentation pathway, but the dominant ion is the protonated ligand-base adduct. MS/MS of this ion confirms the site on binding of the ligand to the guanine base. MS/MS spectra of cisplatin adducts show much less specific fragmentation than alkylated adducts, particularly in the negative ion mode. This suggests that the ESI-MS/MS spectra of ligand-DNA adducts are strongly influenced by the extent to which the ligand weakens the glycosidic bond in the residue to which it is bound. For platinating agents, which do not labilise the glycosidic bond, additional experiments involving MS/MS of source-generated product ions were required to enable isomeric adducts to be distinguished.  相似文献   

16.
Traveling-wave ion mobility (TWIM) coupled to mass spectrometry (MS) has emerged as a powerful tool for structural and conformational analysis of proteins and peptides, allowing the analysis of isomeric peptides (or proteins) with the same sequence but modified at different residues. This work demonstrates the use of the novel TWIM-MS technique to separate isomeric peptide ions derived from chemical cross-linking experiments, which enables the acquisition of distinct product ion spectra for each isomer, clearly indicating modification on different sites. Experiments were performed with four synthetic peptides, for which variable degrees of mobility separation were achieved. In cases of partially overlapping mobility arrival time distributions (ATDs), extracting the ATDs of fragment ions belonging to each individual isomer allowed their separation into two distinct ATDs. Accumulation over regions from the specific ATDs generates the product ion spectrum of each isomer, or a spectrum highly enriched in their fragments. The population of both modified peptide isomers was correlated with the intrinsic reactivities of different Lys residues from reactions conducted at different pH conditions.  相似文献   

17.
A new method based on ultra-performance liquid chromatography (UPLC) quadrupole time-of-flight mass spectrometry ((Q-ToF)-MS) was developed for the analysis of 32 biologically active compounds including anti-inflammatories, analgesics, lipid regulators, psychiatric drugs, anti-ulcer agents, antibiotics, beta-blockers and phytoestrogens. This new method allows chromatographic analysis in 14 min, with instrumental detection limits from 2 to 84 pg, and limits of quantification ranging from 0.1 to 15 ng/L in tap water, and from 2 to 300 ng/L in wastewater. The potential of liquid chromatography with triple quadrupole mass spectrometry (LC/QqQ-MS) was compared with that of UPLC/(Q-ToF)-MS for the analysis of biologically active compounds in water samples. LC/Q-ToF provides accurate mass information and a significantly higher mass resolution than quadrupole analyzers. The available mass resolution of ToF instruments diminishes the problem of isobaric interferences and helps the analysis of trace compounds in complex samples. In this work UPLC/Q-ToF chromatograms were recorded containing full scan spectral data. The m/z values of analytes were extracted from the total ion chromatogram (TIC) and the accurate masses of the compounds were obtained. In addition, to increase the selectivity of ToF measurements a narrow accurate mass interval (20 m m/z units mass window) was used to reconstruct the chromatographic traces. However, regarding quantitative performance in terms of dynamic range and limits of detection (LODs), typical LODs achieved by QqQ instruments operating in multiple-reaction monitoring (MRM) mode ranged from 1 to 50 ng/L in wastewater, and the linear response for QqQ instruments generally covers three orders of magnitude. This is an important advantage over ToF instruments and one of the reasons why QqQ instruments are widely used in quantitative environmental analysis.  相似文献   

18.
The mass spectra of 2- and 4-iminobarbituric acid derivatives were studied in relation to the mass spectra of their oxygen analogs. It is shown that the pathways of fragmentation of the investigated compounds depend on the type of substituent attached to the C5 atom, the position of the imino and oxo groups in the ring, and the specific mass-spectral properties. The fragmentation was studied by means of low-voltage mass spectrometry and deuterium labeling.See [1] for communication I.Translated from Khimiya Geterotsiklicheskikh Soedinenii, No. 6, pp. 813–817, June, 1978.  相似文献   

19.
质谱在肽和蛋白质序列分析中的应用   总被引:7,自引:0,他引:7  
陈晶  付华  陈益  赵玉芬 《有机化学》2002,22(2):81-90
了解肽和蛋白质的序列对理解其功能具有重要意义,测定其序列也是当前生命 科学研究中的重要内容之一,质谱作为高灵敏度的测定分子结构的仪器,其高灵敏 度、广泛的适用性及快速性等特性使它具有很大潜力发展成为辅助传统测序方法的 新方法,并得到了广泛的关注。从离子活化方法(包括碰撞诱导解离CID、源后裂 解PSD、源内裂解ISD等)、衍生化作用以及氨基酸残基消除方式(高能活化产生亚 稳离子、化学降解、酶降解)等多个角度介绍了利用质谱分析多肽和蛋白质序列的 方法,并对其发展前景作出展望。  相似文献   

20.
The prion protein (PrP) is implicitly involved in the pathogenesis of transmissible spongiform encephalopathies (TSEs). The conversion of normal cellular PrP (PrPC), a protein that is predominantly α-helical, to a β-sheet-rich isoform (PrPSc), which has a propensity to aggregate, is the key molecular event in prion diseases. During its short life span, PrP can experience two different pH environments; a mildly acidic environment, whilst cycling within the cell, and a neutral pH when it is glycosyl phosphatidylinositol (GPI)-anchored to the cell membrane. Ion mobility (IM) combined with mass spectrometry has been employed to differentiate between two conformational isoforms of recombinant Syrian hamster prion protein (SHaPrP). The recombinant proteins studied were α-helical SHaPrP(90-231) and β-sheet-rich SHaPrP(90-231) at pH 5.5 and pH 7.0. The recombinant proteins have the same nominal mass-to-charge ratio (m/z) but differ in their secondary and tertiary structures. A comparison of traveling-wave (T-Wave) ion mobility and drift cell ion mobility (DCIM) mass spectrometry estimated and absolute cross-sections showed an excellent agreement between the two techniques. The use of T-Wave ion mobility as a shape-selective separation technique enabled differentiation between the estimated cross-sections and arrival time distributions (ATDs) of α-helical SHaPrP(90-231) and β-sheet-rich SHaPrP(90-231) at pH 5.5. No differences in cross-section or ATD profiles were observed between the protein isoforms at pH 7.0. The findings have potential implications for a new ante-mortem screening assay, in bodily fluids, for prion misfolding diseases such as TSEs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号