首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Ratiometric measurement is a technique that can provide precise data and even quantitative detection. To carry out ratiometric measurements, it is necessary that the sensor molecule exhibits a large shift in its emission or excitation spectrum after reaction with the target molecule. Fluorescence resonance energy transfer (FRET) is one mechanism used to obtain a large spectral shift. In this study, our aim was to develop a ratiometric fluorescent sensor molecule for phosphodiesterase activity based on FRET. We designed and synthesized CPF4 with a coumarin donor, a fluorescein acceptor, and two phenyl linkers having the phosphodiester moiety interposed between them. In the emission spectrum of CPF4 in aqueous buffer excited at 370 nm, the emission of the coumarin donor was strongly quenched and the emission of the fluorescein acceptor was observed. This emission spectrum demonstrates that energy transfer from the coumarin donor to the fluorescein acceptor proceeds efficiently. Addition of a phosphodiesterase to an aqueous solution of CPF4 resulted in an increase in the donor fluorescence and a decrease in the acceptor fluorescence. CPF4 exhibited a large shift in its emission spectrum after the hydrolysis of the phosphodiester group by the enzyme. This large shift of the emission spectrum indicates that ratiometric measurements can be made by using CPF4. The method described in this paper for designing enzyme-cleavable sensor molecules based on FRET should be readily applicable to other hydrolytic enzymes.  相似文献   

2.
A ratiometric measurement, namely, simultaneous recording of the fluorescence intensities at two wavelengths and calculation of their ratio, allows greater precision than measurements at a single wavelength, and is suitable for cellular imaging studies. Here we describe a novel method of designing probes for ratiometric measurement of hydrolytic enzyme activity based on switching of fluorescence resonance energy transfer (FRET). This method employs fluorescent probes with a 3'-O,6'-O-protected fluorescein acceptor linked to a coumarin donor through a linker moiety. As there is no spectral overlap integral between the coumarin emission and fluorescein absorption, the fluorescein moiety cannot accept the excitation energy of the donor moiety and the donor fluorescence can be observed. After cleavage of the protective groups by hydrolytic enzymes, the fluorescein moiety shows a strong absorption in the coumarin emission region, and then acceptor fluorescence due to FRET is observed. Based on this mechanism, we have developed novel ratiometric fluorescent probes (1-3) for protein tyrosine phosphatase (PTP) activity. They exhibit a large shift in their emission wavelength after reaction with PTPs. The fluorescence quenching problem that usually occurs with FRET probes is overcome by using the coumarin-cyclohexane-fluorescein FRET cassette moiety, in which close contact of the two dyes is hindered. After study of their chemical and kinetic properties, we have concluded that compounds 1 and 2 bearing a rigid cyclohexane linker are practically useful for the ratiometric measurement of PTPs activity. The design concept described in this paper, using FRET switching by spectral overlap integral and a rigid link that prevents close contact of the two dyes, should also be applicable to other hydrolytic enzymes by introducing other appropriate enzyme-cleavable groups into the fluorescein acceptor.  相似文献   

3.
A method has been developed for the quantitative determination of fluorescence resonance energy transfer (FRET) based on the modulation of donor fluorescence upon the reversible photoconversion of a photochromic acceptor. A model system was devised, consisting of Lucifer Yellow cadaverine (LYC, donor) conjugated to the photochromic molecule, 6-nitroBIPS (1′,3′-dihydro-1′-(2-carboxyethyl)-3′,3′-dimethyl-6-nitrospiro[2H-1-benzopyran-2,2′-(2H)-indoline]). Near-ultraviolet irradiation catalyzes the conversion of the colorless spiropyran (SP) to the colored merocyanine (MC) form of 6-nitroBIPS. Only the MC form absorbs at the emission wavelengths of the donor, thereby potentiating FRET, as demonstrated by quenching of the donor. Subsequent irradiation in the visible MC absorption band reverts 6-nitroBIPS to the SP form and FRET is inactivated. The acceptor exhibited high photostability under repeated cycles of alternating UV–Vis irradiation. In this model system, the intramolecular FRET efficiency was close to 100%. The observed maximal donor quenching of 34±3% was indicative of an equilibrium determined by the high quantum efficiency of forward conversion (SP→MC) induced by near-UV irradiation and a low but finite quantum efficiency of the back reaction resulting from excitation of the MC form directly as well as indirectly (by FRET via the donor). A quantitative formalism for the photokinetic scheme was developed. Photochromic FRET (pcFRET) permits repeated, quantitative, and non-destructive FRET determinations for arbitrary relative concentrations of donor and acceptor and thus offers great potential for monitoring dynamic molecular interactions in living cells over extended observation times by fluorescence microscopy.  相似文献   

4.
We have employed diheteroarylethenes as acceptors for photochromic FRET (pcFRET), a technique introduced for the quantitative determination of fluorescence resonance energy transfer (FRET). In pcFRET, the fluorescent emission of the donor is modulated by cyclical transformations of a photochromic acceptor. Light induces a reversible change in the structure and, concomitantly, in the absorption properties of the acceptor. Only the closed forms of the selected diheteroarylethenes 2a and 2b have an absorption band overlapping the emission band of the donor, 1. The corresponding variation in the overlap integral (and thus critical transfer distance R(o)) between the two states provides the means for reversibly switching the process of FRET on and off, allowing direct and repeated evaluation of the relative changes in the donor fluorescence quantum yield. The diheteroarylethenes demonstrate excellent stability in aqueous media, an absence of thermal back reactions, and negligible fatigue. The equilibration of these systems after exposure to near-UV or visible light follows simple monoexponential kinetics. We developed a general conceptual scheme for such coupled photochromic-FRET reactions, allowing quantitative interpretations of the photostationary and kinetic data, from which the quantum yields for the cyclization and cycloreversion reactions of the photochromic acceptor were calculated.  相似文献   

5.
在pH8.5的Tris-HCl缓冲溶液中,钙黄绿素作为能量供体(D)可以与藏红T受体(A)发生有效的荧光共振能量转移(FRET),但加入六偏磷酸钠(SHMP)后,因其与受体发生静电作用破坏了该能量转移体系,使得荧光供体钙黄绿素荧光强度的增加(△FD)与受体藏红T荧光强度的降低(△FA)的比值(△FD/△R)-9SHMP浓度(csHMP)呈良好的线性关系.基于此,建立了一种检测六偏磷酸盐的新方法.在优化条件下,该方法的检测范围为3.0×10^-6-1.0×10^-5mol/L,对6.0×10拍mol/L的六偏磷酸盐连续平行测定11次,其相对标准偏差(RSD)为3.1%.该方法具有选择性好、操作简单和检测速度快等优点,已成功应用于饮料中六偏磷酸钠的分析检测.  相似文献   

6.
Shan Hu 《Talanta》2009,80(2):454-12607
A novel method to significantly enhance fluorescence resonance energy transfer (FRET) signal which occurred from fluoresceine isothiocyanate (FITC) to Dylight 549 was studied in this paper. Streptavidin was labeled with the donor fluorophore FITC and biotinamide was conjugated to the acceptor Dylight 549. When biotinamide bound to streptavidin, FRET would occur from FITC to Dylight 549 while a remarkable fluorescence enhancement of streptavidin-FITC was observed. The fluorescence enhancement of streptavidin-FITC in the presence of biotin was utilized in the FRET system to obtain higher fluorescence signal. Increase of fluorescence intensity of FITC and decrease of Dylight 549 depended on the concentration of competitive biotin. A homogeneous analysis method was established based on the fluorescence recovery of FITC in the FRET system with fluorescence enhancement. This method is highly sensitive and simple to determine the concentration of biotin. The detection limit for biotin was 0.5 nM and the linear range of the assay was 0.8-9.8 nM. The response time is no more than 15 min during the one-step assay due to the high affinity between streptavidin and biotin.  相似文献   

7.
探讨以两种新荧光蛋白MiCy,mKo为传能对并应用供体光漂白法测量荧光共振能量转移(FRET)效率.首先通过基因工程方法表达纯化了这两种蛋白,并测量了荧光光谱及光漂白性质,表明MiCy极易光漂白而mKo抗光漂白.进一步以Ni-NTA-agarose为FRET模型,在Confocal上对MiCy进行光漂白时间常数的测量,并计算了FRET效率.结果表明MiCy-mKo传能对适合用供体光漂白法测量FRET效率,此传能对将在蛋白质相互作用研究中有广泛应用.  相似文献   

8.
Detection of F?rster resonance energy transfer (FRET) between cyan and yellow fluorescent proteins is a key method for quantifying dynamic processes inside living cells. To compare the different cyan and yellow fluorescent proteins, FRET efficiencies were measured for a set of the possible donor:acceptor pairs. FRET between monomeric Cerulean and Venus is more efficient than the ECFP:EYFP pair and has a 10% greater F?rster distance. We also compared several live cell microscopy methods for measuring FRET. The greatest contrast for changes in intramolecular FRET is obtained using a combination of ratiometric and spectral imaging. However, this method is not appropriate for establishing the presence of FRET without extra controls. Accurate FRET efficiencies are obtained by fluorescence lifetime imaging microscopy, but these measurements are difficult to collect and analyze. Acceptor photobleaching is a common and simple method for measuring FRET efficiencies. However, when applied to cyan to yellow fluorescent protein FRET, this method becomes prone to an artifact that leads to overestimation of FRET efficiency and false positive signals. FRET was also detected by measuring the acceptor fluorescence anisotropy. Although difficult to quantify, this method is exceptional for screening purposes, because it provides high contrast for discriminating FRET.  相似文献   

9.
We used lanthanide-ion doped oxide nanoparticles, Y(0.6)Eu(0.4)VO(4), as donors in fluorescent resonance energy transfer (FRET) experiments. The choice of these nanoparticles allows us to combine the advantages of the lanthanide-ion emission, in particular the long lifetime and the large Stokes shift between absorption and emission, with the detectability of the nanoparticles at the single-particle level. Using cyanine 5 (Cy5) organic molecules as acceptors, we demonstrated FRET down to the single-nanoparticle level. We showed that, due to the long donor lifetime, unambiguous and precise FRET measurements can be performed in solution even in the presence of large free acceptor concentrations. Highly efficient energy transfer was obtained for a large number of acceptor molecules per donor nanoparticle. We determined FRET efficiencies as a function of Cy5 concentration which are in good agreement with a multiple acceptor-multiple donor calculation. On the basis of the donor emission recovery due to acceptor photobleaching, we demonstrated energy transfer from single-nanoparticle donors in fluorescence microscopy experiments.  相似文献   

10.
Wang L  Wang Y  Ragauskas AJ 《The Analyst》2012,137(6):1319-1324
The determination of cellulase distribution on the surface of cellulose fiber is an important parameter to understand when determining the interaction between cellulase and cellulose and/or the cooperation of different types of cellulases during the enzymatic hydrolysis of cellulose. In this communication, a strategy is presented to quantitatively determine the cellulase colocalization using the fluorescence resonance energy transfer (FRET) methodology, which is based on acceptor photobleaching and spectrally unmixing fluorescence microscopy. FRET monitoring of cellulase colocalization was achieved by labeling cellulases with an appropriate pair of FRET dyes and by adopting an appropriate FRET model. We describe here that the adapted acceptor photobleaching FRET method can be successfully used to quantify cellulase colocalization regarding their binding to a cellulose fiber at a resolution <10 nm. This developed quantitative FRET method is promising for further studying the interactions between cellulase and cellulose and between different types of cellulases.  相似文献   

11.
Chen H  Kenny JE 《The Analyst》2012,137(1):153-162
One of the conventionally accepted requirements for parallel factor analysis (PARAFAC) to handle the fluorescence excitation emission matrices (EEMs) is the independence of each component's absorption and emission spectra in simple mixtures of fluorophores. EEMs of samples in which F?rster resonance energy transfer (FRET) occurs between fluorophores seem to fail to meet this requirement. A rigorous theoretical treatment of the steady-state kinetics in the present work indicates that the fluorescence in the presence of FRET, excited by relatively weak excitation light intensity, can be reasonably separated into additive contributions from three parts: donors, acceptors and FRET. This prediction is for the first time verified experimentally in sodium dodecyl sulfate micellar solutions containing biphenyl as the energy donor and 2,5-diphenyloxazole as the energy acceptor. The experimental EEMs were well fitted to three components as predicted. A well accepted diagnostic test called core consistency (CC), specifically designed for modeling simple mixtures of fluorophores with PARAFAC, was found to be negative for the 3-component model in the present study. The simultaneous occurrence of good model fit and significantly negative CC when modeling fluorophore mixtures by conventional PARAFAC would be indicative of the presence of physical/chemical processes (e.g., FRET) that deviate from the conventional working requirements for PARAFAC. The extent of FRET has been independently measured or calculated by three methods: 1) decrease in steady state fluorescence of donor; 2) lifetime measurements with population analysis; and 3) Poisson statistics based on PARAFAC-determined distribution constants. The results of the three methods are consistent. The normalized scores of the three components found by PARAFAC also agree to within a few percent with relative concentrations in aqueous and micelle phases determined from distribution constants for the solutions prepared with nine different combinations of total donor and acceptor concentrations. Our theoretical treatment also for the first time spells out in detail the relationship between the PARAFAC scores and concentrations of components, in terms of photophysical constants of the components and spectral shape factors.  相似文献   

12.
Ultrafast fluorescence resonance energy transfer (FRET) from coumarin 153 (C153) to rhodamine 6G (R6G) is studied in a neutral PEO(20)-PPO(70)-PEO(20) triblock copolymer (P123) micelle and an anionic micelle (sodium dodecyl sulfate, SDS) using a femtosecond up-conversion setup. Time constants of FRET were determined from the rise time of the acceptor emission. It is shown that a micelle increases efficiency of FRET by holding the donor and the acceptor at a close distance (intramicellar FRET) and also by tuning the donor and acceptor energies. It is demonstrated that in the P123 micelle, intramicellar FRET (i.e., donor and acceptor in same micelle) occurs in 1.2 and 24 ps. In SDS micelle, there are two ultrafast components (0.7 and 13 ps) corresponding to intramicellar FRET. The role of diffusion is found to be minor in the ultrafast components of FRET. We also detected a much longer component (1000 ps) for intramicellar FRET in the larger P123 micelle.  相似文献   

13.
The work presented herein is devoted to the fabrication of large Stokes shift dyes in both organic and aqueous media by combining dark resonance energy transfer (DRET) and fluorescence resonance energy transfer (FRET) in one donor–acceptor system. In this respect, a series of donor–acceptor architectures of 4,4‐difluoro‐4‐bora‐3a,4a‐diaza‐s‐indacene (BODIPY) dyes substituted by one, two, or three tetraphenylethene (TPE) luminogens were designed and synthesised. The photophysical properties of these three chromophore systems were studied to provide insight into the nature of donor–acceptor interactions in both THF and aqueous media. Because the generation of emissive TPE donor(s) is strongly polarity dependent, due to its aggregation‐induced emission (AIE) feature, one might expect the formation of appreciable fluorescence emission intensity with a very large pseudo‐Stokes shift in aqueous media when considering FRET process. Interestingly, similar results were also recorded in THF for the chromophore systems, although the TPE fragment(s) of the dyes are non‐emissive. The explanation for this photophysical behaviour lies in the DRET. This is the first report on combining two energy‐transfer processes, namely, FRET and DRET, in one polarity‐sensitive donor–acceptor pair system. The accuracy of the dark‐emissive donor property of the TPE luminogen is also presented for the first time as a new feature for AIE phenomena.  相似文献   

14.
A homogeneous non-competitive assay principle for measurement of small analytes based on quenching of fluorescence is described. Fluorescence resonance energy transfer (FRET) occurs between the donor, intrinsically fluorescent europium(III)-chelate conjugated to streptavidin, and the acceptor, quencher dye conjugated to biotin derivative when the biotin-quencher is bound to Eu-streptavidin. Fluorescence can be measured only from those streptavidins that are bound to biotin of the sample, while the fluorescence of the streptavidins that are not occupied by biotin are quenched by quencher-biotin conjugates. The quenching efficiencies of the non-fluorescent quencher dyes were over 95% and one dye molecule was able to quench the fluorescence of more than one europium(III)-chelate. This, however, together with the quadrovalent nature of streptavidin limited the measurable range of the assay to 0.2-2 nmol L−1. In this study we demonstrated that FRET could be used to design a non-competitive homogeneous assay for a small analyte resulting in equal performance with competitive heterogeneous assay.  相似文献   

15.
A photokinetic method of detection of fluorescence resonance energy transfer (FRET) between special fluorescent labels is applied to study time-averaged spatial distribution of labeled proteins in protein assemblies. Prolonged irradiation of a sample at the absorption maximum of the energy donor initiates FRET-sensitized fluorescence photobleaching of the energy acceptor label, which was monitored by steady-state fluorimetric measurements. Kinetics of the acceptor photobleaching and kinetics of decreasing the efficiency of FRET from donors to unbleached acceptors were determined. The FRET efficiency was found from measuring sensitization of acceptor fluorescence. Analysis of the photokinetic data permits to estimate the time-averaged distribution of acceptors on donor-acceptor distances in the range of characteristic distances of FRET. Dynamic processes influencing donor-acceptor distances can be also investigated by the method. Application of the method is demonstrated by the studies of a complex of biotinylated IgM with streptavidin and aggregates composed of concanavalin A and sodium dodecyl sulphate. A new thiadicarbocyanine dye was used as the acceptor label. R-phycoerythrin and tetramethylrhodamine isothiocyanate were the donor labels. In the IgM-streptavidin complex, 16% of acceptors most contributed to FRET provided 90% of FRET efficiency, whereas acceptors made about the same time-averaged contribution to FRET in the concanavalin A aggregates.  相似文献   

16.
We report on the development of a self-assembled donor for long-range fluorescence resonance energy transfer (FRET). To this end, a three-chromophore FRET (3Ch-FRET) system was constructed, which consists of a luminescent quantum dot (QD), enhanced yellow fluorescent proteins (EYFP), and Atto647-dye-modified oligonucleotides. The system was assembled by electrostatic binding of covalent EYFP-ssDNA conjugate to the QD and subsequent hybridization with complementary oligonucleotides labeled with Atto647-dye. The final conjugates comprise three different two-chromophore FRET (2Ch-FRET) subsystems, QD/EYFP, QD/Atto647, and EYFP/Atto647, respectively, which were studied in detail by steady-state and time-resolved photoluminescence measurements. The helicity of DNA allowed us to control donor/acceptor separations and thus enabled the detailed analysis of the various FRET processes. We found that the 2Ch-FRET and the 3Ch-FRET (QD/EYFP/Atto647) systems revealed FRET efficiencies and transfer rates that were affected by the availability of distinct FRET pathways. The derived energy-transfer efficiencies and F?rster radii indicated that within the 3Ch-FRET system, the 2Ch-FRET subsystem QD/EYFP showed highest FRET efficiencies ranging from 64 to 72%. Thus, it can be used as a powerful donor system that combines the intrinsic advantages of QDs (large and spectrally broad absorption cross section) and EYFP (high quantum yield) and enables long-distance FRET processes for donor-acceptor distances of up to 13 nm.  相似文献   

17.
The thioglycolic acid-functionalized CdTe quantum dots (QDs) were synthesized in aqueous solution using safe and low-cost inorganic salts as precursors. Fluorescence resonance energy transfer (FRET) system was constructed between CdTe QDs (donor) and butyl-rhodamine B (BRB) (acceptor) in the presence of cetyltrimethylammonium bromide (CTMAB). CTMAB micelles formed in water reduced the distance between the donor and the acceptor significantly and thus improved the FRET efficiency, which resulted in an obvious fluorescence enhancement of the acceptor. Several factors which impacted the fluorescence spectra of the FRET system were studied. The energy transfer efficiency (E) and the distance (r) between CdTe and BRB were obtained. The feasibility of the prepared FRET system as fluorescence probe for detecting Hg(II) in aqueous solution was demonstrated. At pH 6.60, a linear relationship could be established between the quenched fluorescence intensity of BRB and the concentration of Hg(II) in the range of 0.0625-2.5mumolL(-1). The limit of detection was 20.3nmolL(-1). The developed method was proved to be sensitive and repeatable to detect Hg(II) in a wide range in aqueous solutions.  相似文献   

18.
19.
A selective and sensitive fluorometric determination method for native fluorescent peptides has been developed. This method is based on intramolecular fluorescence resonance energy transfer (FRET) detection in a liquid chromatography (LC) system following precolumn derivatization of the amino groups of tryptophan (Trp)-containing peptides. In this detection process, we monitored the FRET from the native fluorescent Trp moieties (donor) to the derivatized fluorophore (acceptor). From a screening study involving 10 fluorescent reagents, we found that o-phthalaldehyde (OPA) generated FRET most effectively. The OPA derivatives of the native fluorescent peptides emitted OPA fluorescence (445 nm) through an intramolecular FRET process when they were excited at the excitation maximum wavelength of the Trp-containing peptides (280 nm). The generation of FRET was confirmed through comparison with the analysis of a non-fluorescent peptide (C-reactive protein fragment (77 - 82)) performed using LC and a three-dimensional fluorescence detection system. We were able to separate the OPA derivatives of the Trp-containing peptides when performing LC on a reversed-phase column. The detection limits (signal-to-noise ratio = 3) for the Trp-containing peptides, at a 20-microL injection volume, were 41 - 180 fmol. The sensitivity of the intramolecular FRET-forming derivatization method is higher than that of the system that takes advantage of the conventional detection of OPA derivatives. Moreover, native non-fluorescent amines and peptides in the sample monitored at FRET detection are weaker than those of conventional fluorescence detection.  相似文献   

20.
We report the design, synthesis, and characterization of binary oligonucleotide probes for mRNA detection. The probes were designed to avoid common problems found in standard binary probes such as direct excitation of the acceptor fluorophore and overlap between the donor and acceptor emission spectra. Two different probes were constructed that contained an array of either two or three dyes and were characterized using steady-state fluorescence spectroscopy, time-resolved fluorescence spectroscopy, and fluorescence depolarization measurements. The three-dye binary probe (BP-3d) consists of a Fam fluorophore which acts as a donor, collecting light and transferring it as energy to Tamra, which subsequently transfers energy to Cy5 when the two probes are hybridized to mRNA. This design allows the use of 488 nm excitation, which avoids the direct excitation of Cy5 and at the same time provides a good fluorescence resonance energy transfer (FRET) efficiency. The two-dye binary probe system (BP-2d) was constructed with Alexa488 and Cy5 fluorophores. Although the overlap between the fluorescence of Alexa488 and the absorption of Cy5 is relatively low, FRET still occurs due to their close physical proximity when the probes are hybridized to mRNA. This framework also decreases the direct excitation of Cy5 and reduces the fluorescence overlap between the donor and the acceptor. Picosecond time-resolved spectroscopy showed a reduction in the fluorescence lifetime of donor fluorophores after the formation of the hybrid between the probes and target mRNA. Interestingly, BP-2d in the presence of mRNA shows a slow rise in the fluorescence decay of Cy5 due to a relatively slow FRET rate, which together with the reduction in the Alexa488 lifetime provides a way to improve the signal to background ratio using time-resolved fluorescence spectra (TRES). In addition, fluorescence depolarization measurements showed complete depolarization of the acceptor dyes (Cy5) for both BP-3d (due to sequential FRET steps) and BP-2d (due to the relatively low FRET rate) in the presence of the mRNA target.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号