首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Two methods are presented for the determination of 'respectively' the plasma protein unbound and total concentration of acyclovir in horse plasma and body fluids: first, a liquid-liquid extraction was performed on plasma, combined with HPLC-fluorescence detection for the total plasma concentration; second a more sensitive method using high-performance liquid chromatography combined with heated electrospray ionization tandem mass spectrometry (LC-HESI-MS/MS) was described for plasma and for body fluids analysis. To obtain the unbound concentration of acyclovir in plasma, a simple deproteinization step using a Microcon filter was performed. Ganciclovir was used as an internal standard. Analysis was carried out on an Inertsil 5 ODS-3 column for the HPLC-fluorescence method. For the LC-HESI-MS/MS method a PLRP-S column was used. The limit of quantification (LOQ) for the total concentration was set at 50 and 2 ng mL(-1) for the HPLC-fluorescence method and the LC-HESI-MS/MS method, respectively. The limit of quantification for the unbound concentration was set at 5 ng mL(-1) and at 2 ng mL(-1) for body fluids. The methods were successfully used to perform pharmacokinetic and clinical studies in horses after intravenous and oral dosage of acyclovir and its prodrug valacyclovir.  相似文献   

2.
A method for the quantification of clindamycin in animal plasma using high-performance liquid chromatography combined with electrospray ionization mass spectrometry (LC/ESI-MS/MS) is presented. Lincomycin is used as the internal standard. The sample preparation includes a simple deproteinization step with trichloroacetic acid. Chromatographic separation is achieved on an RP-18 Hypersil column using gradient elution with 0.01 M ammonium acetate and acetonitrile as mobile phase. Good linearity was observed in the range 0-10 microg ml(-1). The limit of quantification of the method is 50 ng ml(-1) and the limit of detection is 1.3 ng ml(-1). The method was shown out to be of use for pharmacokinetic studies of clindamycin formulations in dogs.  相似文献   

3.
A novel, sensitive and specific method for the quantitative determination of ivermectin B(1a) in animal plasma using liquid chromatography combined with positive electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is presented. Abamectin was used as the internal standard. Extraction of the samples was performed with a deproteinization step using acetonitrile. Chromatographic separation was achieved on a Nucleosil ODS 5 microm column, using gradient elution with 0.2% (v/v) acetic acid in water and 0.2% (v/v) acetic acid in acetonitrile. The method was validated according to the requirements defined by the European Community. Calibration curves using plasma fortified between 1 and 100 ng ml(-1) showed a good linear correlation (r > or = 0.9989, goodness-of-fit coefficient < or =8.1%). The trueness at 2 and 25 ng ml(-1) (n = 6) was +4.2 and -17.1%, respectively. The trueness and between-run precision for the analysis of quality control samples at 25 ng ml(-1) was -4.0 and 11.0%, respectively (n = 16). The limit of quantification of the method was 1.0 ng ml(-1), for which the trueness and precision also fell within acceptable limits. Using a signal-to-noise ratio of 3 : 1, the limit of detection was calculated to be 0.2 ng ml(-1). The specificity was demonstrated with respect to ivermectin B(1b).The method was successfully used for the quantitative determination of ivermectin B(1a) in plasma samples from treated bovines, demonstrating the usefulness of the developed method for application in the field of pharmacokinetics.  相似文献   

4.
A reversed-phase column liquid chromatographic (LC) method with electrochemical detection (ED) is described for the quantification of 2,3-dihydro-6-[3-(2-hydroxymethyl)phenyl-2-propenyl]-5-benzofuranol (compound 1), a new locally active dual inhibitor of leukotriene and prostaglandin synthesis, in plasma. After a single liquid-liquid extraction of the biological specimen, the extract was analyzed using a liquid chromatograph with an amperometric detector set at an oxidation potential of +0.55 V. The resulting chromatograms are free from endogenous interference and the limit of detection is 0.2 ng/ml. Several other analogous dihydrobenzofuranols were shown to be electrochemically active, permitting their determination using LC with ED. The described analytical method has been fully validated in the concentration range 0.5-20 ng/ml of plasma and utilized in the analysis of plasma samples from human clinical studies. The analytical methodology has also been adapted for analysis of compound 1 in human skin blister fluid after topical administration of 1.  相似文献   

5.
A highly sensitive thermospray liquid chromatographic-mass spectrometric method has been developed for the simultaneous determination of FRC-8653 (I), a new calcium antagonist, and its main metabolite (M-4) in plasma. A deuterated analogue of I was added to the plasma as the internal standard. After the purification and concentration of the plasma sample on bonded-phase disposable columns, the extract was injected into the thermospray liquid chromatograph and analysed by selected-ion monitoring mass spectrometry. The calibration curves obtained were linear over the concentration range 0.5-100 ng/ml. The limits of quantification are 0.5 ng/ml for I and 1 ng/ml for M-4 in plasma, which are sufficient to evaluate plasma concentrations after oral administration to rats.  相似文献   

6.
A rapid and specific HPLC method has been developed and validated for the simultaneous determination of propafenone, an antiarrhythmic agent, and its major metabolites in human serum. The sample preparation was a simple deproteinization with a mixture of ZnSO4 and methanol, yielding almost 100% recoveries of three compounds. Separation was developed on a reverse-phase tracer excel C18 column (25 x 0.46 cm i.d., 5 microm), using an acetonitrile-phosphate buffer gradient at a flow rate of 1.7 ml min(-1), and UV detection of 210 nm. The calibration curves were linear (r2 > 0.999) in the concentration range of 10 - 750 ng ml(-1). The lower limit of quantification was 10 ng ml(-1) for all of the compounds studied. The within and between day precisions in the measurement of QC samples at four tested concentrations were in the range of 1.4 - 8.1% and 4.2 - 11.5% RSD, respectively. The developed procedure was applied to assess the pharmacokinetics of propafenone and its major metabolites following administration of a single 300 mg oral dose of propafenone hydrochloride to three healthy male volunteers.  相似文献   

7.
《Analytical letters》2012,45(13):2391-2400
Abstract

A simple and rapid high-performance liquid chromatographic (HPLC) method for the determination of amiodarone (AD) in plasma and tissues was developed. The method involved deproteinization of plasma or homogenized tissue with acetonitrile containing an internal standard (N-Cetylpyridinium chloride) followed by reversed phase chromatography using μ bondapack C18 column (10μm) with a mobile phase consisting of acetonitrile - methanol - sodium dihydrogen phosphate buffer (70:10:20%, v/v), the pH adjusted to 4.0 and pumped at flow rate of 1.0 ml/min. The column effluent was monitored at 242 nm. A linear relationship was obtained between peak height ratios (drug to internal standard) versus drug levels over the concentration range of 50–750 ng/ml. The detection limit of AD in plasma and tissues by this method was 20 ng/ml.  相似文献   

8.
A method for the quantification of clavulanic acid in calf plasma using high-performance liquid chromatography combined with electrospray ionization (ESI) mass spectrometry, operating in the negative ionization mode (LC-MS/MS), is presented. Sample preparation includes a simple and fast deproteinization with acetonitrile and a back-extraction of the acetonitrile with dichloromethane. Chromatography is performed on a reversed-phase PLRP-S polymeric column using 0.05% formic acid in water and acetonitrile. The limit of quantification is 25 ng/ml, which is lower than other published methods using ultraviolet (UV), fluorimetric or mass spectrometric detection. The limit of detection is calculated to be 3.5 ng/ml. The stability of clavulanic acid was demonstrated according to The Guidelines of Bioanalytical Method Validation of The Food and Drug Administration (FDA): freeze and thaw stability, short-term stability, long-term stability, stock solution stability and postpreparative stability. The method is used in a pharmacokinetic and bioequivalence study of amoxycillin/clavulanic acid formulations in calves.  相似文献   

9.
Interspecies differences in the pharmacokinetics of an antiallergic agent, 1-(2-ethoxyethyl)-2-(hexahydro-4-methyl-1,4-diazepin-1-yl)benzimid azole difumarate (KG-2413) after intravenous administration were investigated in rats, guinea pigs and dogs. The disappearance of unchanged KG-2413 base was described by biexponential curves in all three animal species. The areas under the plasma concentration-time curves (AUC) in rats, guinea pigs and dogs were 218, 421 and 369 ng.h/ml, respectively, at a dose of 2 mg/kg. The volume of distribution in rats was comparable to that in dogs, and was about three times greater than that in guinea pigs. This might be due to the difference in the unbound fractions of KG-2413 base in plasma (fu), that is, the values of fu in rats, dogs and guinea pigs were 0.607, 0.603 and 0.189, respectively. The first-order elimination rate constant from the central compartment (kcl) in dogs were smaller than those in rats and guinea pigs. Total body clearances (CLtot) of KG-2413 base in rats and guinea pigs were comparable to the hepatic blood flow rate (Q) of each animal. Assuming that KG-2413 base is only eliminated in the liver, relatively rapid metabolism of KG-2413 base occurred in the liver of rats and guinea pigs. In dogs, extrahepatic elimination was suggested because the value of CLtot seemed to be greater than that of Q.  相似文献   

10.
A sensitive and specific method for the quantitative determination of paroxetine in human plasma is presented. After solvent extraction from plasma with hexane/ethyl acetate (1 : 1) at alkaline pH and derivatization to the pentafluorobenzyl carbamate derivative, paroxetine was measured by gas chromatography-negative ion chemical ionization mass spectrometry. The carboxylate anion at m/z 372 was obtained at high relative abundance. [2H6]-labeled paroxetine was used as an internal standard and its rapid and facile preparation from the unlabeled compound is described. Calibration graphs were linear within a range of 0.094-12.000 ng x ml(-1) using 1 ml of plasma and 0.469-60 ng x ml(-1) using 200 microl of plasma. Intra-day precision was 1.47% (0.375 ng x ml(-1)), 3.16% (3 ng x ml(-1)) and 1.37% (9 ng x ml(-1)) for the low-level method, and 3.37% (1.875 ng x ml(-1)), 2.72% (15 ng x ml(-1)) and 2.22% (45 ng x ml(-1)) for the high-level method. Inter-day precision was 1.65% (0.375 ng x ml(-1)), 2.13% (3 ng x ml(-1)) and 1.66% (9 ng x ml(-1)) for the low-level method, and 1.10% (1.875 ng x ml(-1)), 1.56% (15 ng x ml(-1)) and 1.90% (45 ng x ml(-1)) for the high-level method. At the limit of quantification (0.094 ng x ml(-1)), intra-day precision was 4.30% (low-level method) and 2.56% (high-level method), and inter-day precision was 3.23% (low-level method) and 3.00% (high-level method). The method is rugged, rapid and robust and has been applied to the batch analysis of paroxetine during pharmacokinetic profiling of the drug.  相似文献   

11.
A reversed-phase HPLC method for the analysis of cephalexin (7-[(aminophenylacetyl)amino]-3-methyl-8-oxo-5-thia-1-azabicyclo[4.2.0]oct-2-ene-2-carboxylic acid) by isocratic separation is described. A comparison is made between the ultrafiltration land the extraction procedure developed in our laboratory. The extraction procedure, based on the deproteinization of plasma with perchloric acid followed by the extraction with dichloroethane and separation of cephalexin on a reversed phase column, gave better recovery. Quantitative validation of our method has been performed by an external standard technique. The relative standard deviations were between 1.1 and 1.9% in the within-day assay and between 1.2 and 2.2% in the inter-day assay. The limit of detection was 0.14ug/ml and the limit of quantification was 0.28ug/ml. This method is rapid, sensitive, simple, and reproducible. The LC MS/MS technique was successfully used for identification and quantification of cephalexin in human plasma samples.  相似文献   

12.
Dose-dependent pharmacokinetics of glycyrrhizin in rats.   总被引:3,自引:0,他引:3  
The dose-dependent pharmacokinetics of glycyrrhizin (GLZ) was investigated by measuring drug disappearance from plasma and biliary excretion in rats. The decline in plasma concentration was biexponential after an i.v. dose of 5, 10, 20, or 50 mg/kg. Dosage, however, had a marked effect on the pharmacokinetics, with a greater-than-proportional increase in area under the plasma concentration curve (AUC) at doses of 20 and 50 mg/kg, even though the increase was proportional at doses of 5 and 10 mg/kg. There was also a significant increase of the steady-state distribution volume (Vdss), as well as significant decreases in total body (CLtot) and biliary (CLB) clearances, at 20 and 50 mg/kg from those at 5-10 and 5-20 mg/kg, respectively. The AUC, Vdss, and renal clearance (CLR) at a given dose showed no significant difference between rats with and without bile fistulas. The plasma unbound fraction (fp) (0.006-0.026) increased with increasing plasma GLZ concentration over the observed range (2-900 micrograms/ml). No significant change in Vdss for unbound GLZ was observed between the doses, indicating that the distribution of GLZ into tissues is not changed by an increase in dose. On the other hand, a dose dependency in CLtot for unbound GLZ was observed and confirmed to be attributed to dose dependency in CLB for unbound GLZ since there was no significant difference in CLR or metabolic clearance for unbound GLZ between the doses.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

13.
A liquid chromatographic method using a solid-phase extraction procedure for the quantification of sotalol in plasma and urine is described. Sotalol is eluted from an extraction column with ethyl acetate-acetonitrile (1:2) and, after separation by reversed-phase high-performance liquid chromatography on a mu Bondapak C18 column, is quantified by fluorescence detection at excitation and emission wavelengths of 240 and 310 nm, respectively. The method has been demonstrated to be linear over the concentration ranges 10-6000 ng/ml in plasma and 0.5-100 micrograms/ml in urine. Mean inter-assay accuracy of the method for plasma ranged from 93 to 100% and for urine from 102 to 114%; precision ranged from 0.5 to 1.6% for plasma over a concentration range of 200-4000 ng/ml and for urine from 0.7 to 2.0% at concentrations of 2-50 micrograms/ml. Mass spectrometry confirmed the presence of sotalol in isolated chromatographic fractions of plasma and urine extracts from subjects given sotalol orally.  相似文献   

14.
A rapid, sensitive and robust assay procedure using liquid chromatography coupled with tandem mass spectrometry (LC/MS/MS) for the determination of famotidine in human plasma and urine is described. Famotidine and the internal standard were isolated from plasma samples by cation-exchange solid-phase extraction with benzenesulfonic acid (SCX) cartridges. The urine assay used direct injection of a diluted urine sample. The chromatographic separation was accomplished by using a BDS Hypersil silica column with a mobile phase of acetonitrile-water containing trifluoroacetic acid. The MS/MS detection of the analytes was set in the positive ionization mode using electrospray ionization for sample introduction. The analyte and internal standard precursor-product ion combinations were monitored in the multiple-reaction monitoring mode. Assay calibration curves were linear in the concentration range 0.5--500 ng ml(-1) and 0.05--50 microg ml(-1) in plasma and urine, respectively. For the plasma assay, a 100 microl sample aliquot was subjected to extraction. To perform the urine assay, a 50 microl sample aliquot was used. The intra-day relative standard deviations at all concentration levels were <10%. The inter-day consistency was assessed by running quality control samples during each daily run. The limit of quantification was 0.5 ng ml(-1) in plasma and 0.05 microg ml(-1) in urine. The methods were utilized to support clinical pharmacokinetic studies in infants aged 0-12 months.  相似文献   

15.
The alkylating agents cyclophosphamide (CP) and N, N', N"-triethylenethiophosphoramide (thiotepa) are often co-administered in high-dose chemotherapy regimens. Since these regimens can be complicated by the occurrence of severe and sometimes life-threatening toxicities, pharmacokinetically guided administration of these compounds, to reduce variability in exposure, may lead to improved tolerability. For rapid dose adaptations during a chemotherapy course, we have developed and validated an assay, using liquid chromatography coupled with electrospray tandem mass spectrometry (LC/MS/MS), for the routine quantification of CP, thiotepa and their respective active metabolites 4-hydroxycyclophosphamide (4OHCP) and N, N', N"-triethylenephosphoramide (tepa) in plasma. Because of the instability of 4OHCP in plasma, the compound is derivatized with semicarbazide (SCZ) immediately after sample collection and quantified as 4OHCP-SCZ. Sample pretreatment consisted of protein precipitation with a mixture of methanol and acetronitrile using 100 microl of plasma. Chromatographic separation was performed on an Zorbax Extend C18 column (150 x 2.1 mm i.d., particle size 5 microm), with a quick gradient using 1 mM ammonia solution and acetonitrile, at a flow-rate of 0.4 ml min(-1). The analytical run time was 10 min. The triple quadrupole mass spectrometer was operating in the positive ion mode and multiple reaction monitoring was used for drug quantification. The method was validated over the concentration ranges 200-40,000 ng ml(-1) for CP, 50-5000 ng ml(-1) for 4OHCP-SCZ and 5-2500 ng ml(-1) for thiotepa and tepa, using 100 microl of human plasma. These dynamic concentration ranges proved to be relevant in daily practice. Hexamethylphosphoramide was used as an internal standard. The coefficients of variation were <12% for both intra-day and inter-day precisions for each compound. Mean accuracies were also between the designated limits (+/- 15%). This robust and rapid LC/MS/MS assay is now successfully applied for routine therapeutic drug monitoring of CP, thiotepa and their metabolites in our hospital.  相似文献   

16.
A sensitive and specific high-performance liquid chromatographic method has been developed to measure the catechol-O-methyl-transferase (COMT) inhibitor 3,4-dihydroxy-4'-methyl-5-nitrobenzophenone (Ro 40-7592) in human plasma. The compound and the internal standard were extracted from plasma at pH 2 with n-butyl chloride-ethyl acetate (95:5, v/v). The extract was chromatographed on a reversed-phase column (Hypersil ODS, 5 microns) using a mixture of phosphate buffer (0.05 M, pH 2), methanol and tetrahydrofuran (45:55:5, v/v/v) as the mobile phase. Long-retained components were removed from the system by means of a simple column-switching system. Quantification of the catechol-O-methyltransferase inhibitor was performed by means of coulometric detection (0.1 V). The limit of quantification was about 1 ng/ml, using a 1-ml specimen of plasma. The recovery from human plasma was greater than 88%. The mean inter-assay precision was 5.3% in the range 2.5-1000 ng/ml. Linearity of the standard curve was obtained in the concentration range 2.5-500 ng/ml. The catechol-O-methyltransferase inhibitor was stable in human plasma when stored for six months at -20 degrees C and for 24 h at room temperature. The practicability of the new method was demonstrated by the analysis of more than 400 plasma samples from a tolerance study performed in human volunteers.  相似文献   

17.
A simple and sensitive high-performance liquid chromatographic assay was developed for the quantitative determination of major erythromycin components and their potential metabolites or degradation products in plasma and urine. An ether extract of alkalized plasma sample was chromatographed on a reversed-phase column and the components in the column effluent were monitored by an electrochemical detector. The recovery of the drug from extraction was virtually 100%. The detection limits for erythromycin A in plasma were 5-10 ng/ml and 30 ng/ml using 1 and 0.2 ml of sample, respectively. For urine samples, a simple one-step deproteinization with two volumes of acetonitrile was satisfactory for analysis. The method has been evaluated in plasma and urine from dogs receiving oral or intravenous erythromycin A. The standard curves for potential metabolites or degradation products were not constructed due to the lack of sufficient samples.  相似文献   

18.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated to simultaneously determine gliclazide and metformin in human plasma using huperzine A as the internal standard (IS). After acetonitrile-induced protein precipitation of the plasma samples, gliclazide, metformin and the IS were subjected to LC/MS/MS analysis using electro-spray ionization (ESI). Chromatographic separation was performed on a Hypersil BDS C18 column (50 mm x 2.1 mm, i.d., 3 microm). The method had a chromatographic running time of 2.0 min and linear calibration curves over the concentration ranges of 10-10,000 ng ml(-1) for gliclazide and 7.8-4678.9 ng ml(-1) for metformin. The recoveries of the method were found to be 71-104%. The lower limits of quantification (LOQ) of the method were 10.0 and 7.8 ng ml(-1) for gliclazide and metformin, respectively. The intra- and interday precision was less than 15% for all quality control samples at concentrations of 100, 500, and 2000 ng ml(-1). The validated LC/MS/MS method has been used to study bioequivalence in healthy volunteers. These results indicate that the method was efficient with a very short running time (2.0 min) for metformin and gliclazide compared to the methods reported in the literature. The presented method had acceptable accuracy, precision and sensitivity and was used in clinical bioequivalence study.  相似文献   

19.
A high-performance liquid chromatographic method for the determination of disodium dihydrogen(cycloheptylamino)methylene-bisphosphonate monohydrate (YM175) in plasma, urine and bone is described. Plasma obtained in high-dose animal studies is pretreated by Method A, a simple method using 1 ml of plasma, which is based on deproteinization of plasma followed by coprecipitation of the drug with calcium phosphate and removal of excess calcium ions by AG 50W-X8 resin. Plasma obtained in lower-dose clinical studies is treated by Method B, a more sensitive method using 10 ml of plasma, which is based on solid-phase extraction using a Sep-Pak C18 cartridge coupled with Method A. Urine and bone are treated similarly to Method B. The chromatographic system consists of a mobile phase at pH 11, an alkali-stable column and an electrochemical detector operating in the oxidation mode. The determination limit is 5 ng/ml for Method A and 0.5 ng/ml for Method B in plasma, 1 ng/ml in urine, and 25 ng/g in bone.  相似文献   

20.
A rapid and sensitive HPLC method for the simultaneous determination of paraquat and diquat in human serum has been developed. After deproteinization of the serum with 10% trichloroacetic acid, the samples were separated on a reversed-phase column, and subsequently reduced to their radicals with alkaline sodium hydrosulfite solution. These radicals were monitored with a UV detector at 391 nm. This method permitted the reliable quantification of paraquat over linear ranges of 50 ng - 10 microg/ml and 100 ng - 10 microg/ml for diquat in human serum. The within- and between-day variations are lower than 2.3 and 2.2%, respectively. This technique was also utilized to determine the paraquat and diquat serum levels in a patient who had ingested herbicide (Prigrox L) containing paraquat and diquat.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号