首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
New trends in material science and nanotechnologies have spurred growing interest in eumelanins black insoluble biopolymers derived by tyrosinase‐catalysed oxidation of tyrosine via 5,6‐dihydroxyindole (DHI) and its 2‐carboxylic acid (DHICA). Efficient antioxidant and photoprotective actions, associated with peculiar optoelectronic properties, are recognised as prominent functions of eumelanin macromolecules within the human and mammalian pigmentary system, making them unique candidates for the realisation of innovative bio‐inspired functional soft materials, with structure‐based physical–chemical properties. An unprecedented breakthrough into the mechanism of synthetic eumelanin buildup has derived from a detailed investigation of the oxidative polymerization of DHI and its N‐methyl derivative (NMDHI) by linear and reflectron matrix‐assisted laser/desorption ionization mass spectrometry. Regular collections of oligomers of increasing masses, spanning the entire m/z ranges up to 5000 Da (>30‐mer) and 8000 Da (> 50‐mer) for the two building blocks, respectively, were disclosed. It is the first time that the in vitro polymerisation of dihydroxyindoles to form synthetic eumelanins is explored up to its high mass limits, giving at the same time information on the polymerisation mode, whether it follows a stepwise pattern (being this the conclusion in our case) or a staking sequencing of small‐sized entities. It also highlighted the influence of the N‐methyl substituent on the polymerization process; this opens the way to the production of N‐functionalized, synthetic eumelanin‐inspired soft materials, for possible future technological applications. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

2.
Peptide tagging is a useful tool to improve matrix‐assisted laser desorption/ionization tandem mass spectrometric (MALDI‐MS/MS) analysis. We present a new application of the use of the dansyl chloride (DNS‐Cl). DNS‐Cl is a specific primary amine reagent widely used in protein biochemistry. It adds a fluorescent dimethylaminonaphthalene moiety to the molecule. The evaluation of MALDI‐MS and MS/MS analyses of dansylated peptides shows that dansylation raises the ionization efficiency of the most hydrophilic species compared with the most hydrophobic ones. Consequently, higher Mascot scores and protein sequence coverage are obtained by combining MS and MS/MS data of native and tagged samples. The N‐terminal DNS‐Cl sulfonation improves the peptide fragmentation and promotes the generation of b‐fragments allowing better peptide sequencing. In addition, we set up a labeling protocol based on the microwave chemistry. Peptide dansylation proved to be a rapid and cheap method to improve the performance of liquid chromatography (LC)/MALDI‐MS/MS analysis at the proteomic scale in terms of peptide detection and sequence coverage. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

3.
4.
For matrix‐assisted laser desorption/ionization (MALDI) mass spectra, undesirable ion contamination can occur due to the direct laser excitation of substrate materials (i.e., laser desorption/ionization (LDI)) if the samples do not completely cover the substrate surfaces. In this study, comparison is made of LDI processes on substrates of indium and silver, which easily emit their own ions upon laser irradiation, and conventional materials, stainless steel and gold. A simultaneous decrease of ion intensities with the number of laser pulses is observed as a common feature. By the application of an indium substrate to the MALDI mass spectrometry of alkali salts and alkylammonium salts mixed with matrices, 2,5‐dihydroxybenzoic acid (DHB) or N‐(4‐methoxybenzylidene)‐4‐butylaniline (MBBA), the mixing of LDI processes can be detected by the presence of indium ions in the mass spectra. This method has also been found to be useful for investigating the intrinsic properties of the MALDI matrices: DHB samples show an increase in the abundance of fragment ions of matrix molecules and cesium ions with the number of laser pulses irradiating the same sample spot; MBBA samples reveal a decrease in the level of background noise with an increase in the thickness of the sample layer. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

5.
Continuous flow infrared matrix‐assisted laser desorption electrospray ionization (CF IR MALDESI) mass spectrometry was demonstrated for the on‐line analysis of liquid samples. Samples in aqueous solution were flowed through a 50 µm i.d. fused‐silica capillary at a flow rate of 1–6 µL/min. As analyte aqueous solution flowed through the capillary, a liquid sample bead formed at the capillary tip. A pulsed infrared optical parametric oscillator (OPO) laser with wavelength of 2.94 µm and a 20 Hz repetition rate was focused onto the capillary tip for sample desorption and ablation. The plume of ejected sample was entrained in an electrospray to form ions by MALDESI. The resulting ions were sampled into an ion trap mass spectrometer for analysis. Using CF IR MALDESI, several chemical and biochemical reactions were monitored on‐line: the chelation of 1,10‐phenanthroline with iron(II), insulin denaturation with 1,4‐dithiothreitol, and tryptic digestion of cytochrome c. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

6.
Preparation of samples according to an optimized method is crucial for accurate determination of polymer sample characteristics by Matrix-Assisted Laser Desorption Ionization (MALDI) analysis. Sample preparation conditions such as matrix choice, cationization agent, deposition technique or even the deposition volume should be chosen to suit the sample of interest. Many sample preparation protocols have been developed and employed, yet finding the optimal sample preparation protocol remains a challenge. Because an objective comparison between the results of diverse protocols is not possible, “gut-feeling” or “good enough” is often decisive in the search for an optimum. This implies that sub-optimal protocols are used, leading to a loss of mass spectral information quality. To address this problem a novel analytical strategy based on MALDI imaging and statistical data processing was developed in which eight parameters were formulated to objectively quantify the quality of sample deposition and optimal MALDI matrix composition and finally sum up to an overall quality score of the sample deposition. These parameters can be established in a fully automated way using commercially available mass spectrometry imaging instruments without any hardware adjustments. With the newly developed analytical strategy the highest quality MALDI spots were selected, resulting in more reproducible and more valuable spectra for PEG in a variety of matrices. Moreover, our method enables an objective comparison of sample preparation protocols for any analyte and opens up new fields of investigation by presenting MALDI performance data in a clear and concise way.  相似文献   

7.
Atmospheric pressure (AP) matrix‐assisted laser desorption/ionization (MALDI) is known to suffer from poor ion transfer efficiencies as compared to conventional vacuum MALDI (vMALDI). To mitigate these issues, a new AP‐MALDI ion source utilizing a coaxial gas flow was developed. Nitrogen, helium, and sulfur hexafluoride were tested for their abilities as ion carriers for a standard peptide and small drug molecules. Nitrogen showed the best ion transport efficiency, with sensitivity gains of up to 1900% and 20% for a peptide standard when the target plate voltage was either continuous or pulsed, respectively. The addition of carrier gas not only entrained the ions efficiently but also deflected background species and declustered analyte–matrix adducts, resulting in higher absolute analyte signal intensities and greater signal‐to‐noise (S/N) ratios. With the increased sensitivity of pneumatically assisted (PA) AP‐MALDI, the limits of detection of angiotensin I were 20 or 3 fmols for continuous or pulsed target plate voltage, respectively. For analyzing low‐mass analytes, it was found that very low gas flow rates (0.3–0.6 l min?1) were preferable owing to increased fragmentation at higher gas flows. The analyte lability, type of gas, and nature of the extraction field between the target plate and mass spectrometer inlet were observed to be the most important factors affecting the performance of the in‐line PA‐AP‐MALDI ion source. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

8.
9.
An online nano‐aerosol sample deposition method for matrix‐assisted laser desorption/ionization (MALDI) mass spectrometry is described in which matrix and analyte particles between 50 and 500 nm are aerodynamically focused onto a tight spot, ca. 200 µm in diameter, on the target plate under vacuum. MALDI analysis of the target is performed without additional sample preparation. The method is evaluated with insulin as the analyte and alpha‐cyano‐4‐hydroxycinnamic acid (CHCA) as the matrix. Two preparation modes are compared with conventional dried‐droplet deposition: mixture deposition where a single layer is deposited consisting of particles that contain both matrix and analyte, and layered deposition where an underlayer of matrix particles and an overlayer of analyte particles are deposited separately. Desalting is performed by adding ammonium sulfate to the solution used to generate the matrix aerosol. With mixture deposition, the optimum matrix‐to‐analyte mole ratio is about 500:1 compared with 5000:1 for the conventional dried‐droplet method. With layered deposition, the thicknesses of the matrix and analyte layers are more important determinants of the analyte signal intensity than the matrix‐to‐analyte mole ratio. Analyte signal intensities are independent of matrix layer thickness above 200 nm, and the optimum analyte signal is obtained with an analyte layer thickness of about 100 nm. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
Accurate and rapid determination of trypanosomatids is essential in epidemiological surveillance and therapeutic studies. Matrix‐assisted laser desorption ionization/time of flight mass spectrometry (MALDI‐TOF MS) has been shown to be a useful and powerful technique to identify bacteria, fungi, metazoa and human intact cells with applications in clinical settings. Here, we developed and optimized a MALDI‐TOF MS method to profile trypanosomatids. trypanosomatid cells were deposited on a MALDI target plate followed by addition of matrix solution. The plate was then subjected to MALDI‐TOF MS measurement to create reference mass spectra library and unknown samples were identified by pattern matching using the BioTyper software tool. Several m/z peaks reproducibly and uniquely identified trypanosomatids species showing the potentials of direct identification of trypanosomatids by MALDI‐TOF MS. Moreover, this method discriminated different life stages of Trypanosoma cruzi, epimastigote and bloodstream trypomastigote and Trypanosoma brucei, procyclic and bloodstream. T. cruzi Discrete Typing Units (DTUs) were also discriminated in three clades. However, it was not possible to achieve enough resolution and software‐assisted identification at the strain level. Overall, this study shows the importance of MALDI‐TOF MS for the direct identification of trypanosomatids and opens new avenues for mass spectrometry‐based detection of parasites in biofluids. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

11.
Despite cyanoacrylate fuming being widely used in the forensic science field, its mechanism is not well understood. In this study, matrix‐assisted laser desorption/ionization (MALDI) mass spectrometry is used to study latent fingerprints that have been cyanoacrylate fumed in an attempt to gain insight into the fuming mechanism. In the negative mode mass spectrometry data, four compounds related to the polymerization of cyanoacrylate are identified and their structures are determined from accurate mass and MS/MS. A mechanism is proposed for the formation of these compounds that are regarded as intermediates in the polymerization reaction. In addition, based on the fuming of standard endogenous compounds, we suggest that fatty acids and amino acids are the major catalytic nucleophiles that initiate the polymerization reactions.  相似文献   

12.
Although electrospray sample deposition in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) sample preparation increases the repeatability of both the MALDI signal intensity and the measured molecular mass distribution (MMD), the electrospray sample deposition method may influence the apparent MMD of a synthetic polymer. The MMDs of three polymers of differing thermal stability, polystyrene (PS), poly(ethylene glycol) (PEG), and poly(propylene glycol) (PPG), were studied by MALDI time-of-flight (TOF) MS as the electrospray deposition voltage was varied. The MMDs obtained using the electrospray deposition method were compared with those obtained for hand-spotted samples. No change was observed in the measured polymer MMD when the electrospray deposition voltage was varied in the analysis of PS, but those of PEG and PPG changed at higher electrospray voltages due to increased ion fragmentation. It was also shown that the fragmentation in the hand-spotted samples is dependent on the matrix used in sample preparation.  相似文献   

13.
There is an increasing need for analyzing metabolism in a single cell, which is important to understand the nature of cellular heterogeneity, disease, growth and specialization, etc. However, single cell analysis is often challenging for the traces of samples. In the present study, porous metal enrichment probe sampling combined with matrix‐assisted laser desorption ionization time of flight mass spectrometry ( MALDI‐TOF‐MS) has been applied for in situ analysis of live onion epidemic cell. Porous probe, treated by corroding copper wire with HCl, was directly inserted into a single cell to get cell solution. A self‐made linear actuator was enough to control the penetration of probe into the target cell accurately. Then samples on the tip of probe were eluted and detected by a commercial MALDI‐TOF‐MS directly. The formation of porous microstructure on the probe surface increased the adsorptive capacity of cell solution. The sensitivity of porous probe sampling was 6 times higher than uncorroded probes generally. This method provides a sensitive and convenient way for the sampling and detection of single cell solution. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

14.
15.
The aim of this study was to investigate the utility of ion trap mass spectrometry (ITMS) in combination with the two desorption/ionization methods, electrospray (ESI) and atmospheric pressure matrix‐assisted laser desorption/ionization (AP‐MALDI), for the detection of antioxidants which are applied in lubricants. These experiments should form the base for future investigations of antioxidants in tribologically formed thin layers on the surface of frictional systems. Seventeen different antioxidants were selected out of the group of hindered phenolic and aromatic aminic compounds. Practically all antioxidants could be characterized by positive ion ESI‐ and AP‐MALDI‐ITMS, forming various types/species of molecular ions (e.g. [M]+ . , [M+H]+, [M+Na]+ or [M–2H+H]+). A few compounds could be analyzed by negative ion ESI‐MS, too, but none by negative ion AP‐MALDI‐MS. The influence of target materials in AP‐MALDI‐MS (gold‐ and titanium nitride (TiN)‐covered stainless steel, micro‐diamond‐covered hard metal, hand‐polished and sand‐blasted stainless steel targets) with respect to the molecular ion intensity and type of molecular ion of two selected antioxidants was evaluated. The surface properties are of particular interest because in friction tests different materials with different surface characteristics are used. However, the MS results indicate that optimal target surfaces have to be found for individual antioxidants in AP‐MALDI‐MS but in general smooth surfaces were superior to rough surfaces. Finally the gold‐covered stainless steel MALDI target provided the best mass spectra and was selected for all the antioxidants investigated. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
Hepcidin is known to be a key systemic iron‐regulatory hormone which has been demonstrated to be associated with a number of iron disorders. Hepcidin concentrations are increased in inflammation and suppressed in hemochromatosis. In view of the role of hepcidin in disease, its potential as a diagnostic tool in a clinical setting is evident. This study describes the development of a matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS) assay for the quantitative determination of hepcidin concentrations in clinical samples. A stable isotope labeled hepcidin was prepared as an internal standard and a standard quantity was added to urine samples. Extraction was performed with weak cation‐exchange magnetic nanoparticles. The basic peptides were eluted from the magnetic nanoparticles using a matrix solution directly onto a target plate and analyzed by MALDI‐TOF MS to determine the concentration of hepcidin. The assay was validated in charcoal stripped urine, and good recovery (70–80%) was obtained, as were limit of quantitation data (5 nmol/L), accuracy (RE <10%), precision (CV <21%), within ‐day repeatability (CV <13%) and between‐day repeatability (CV <21%). Urine hepcidin levels were 10 nmol/mmol creatinine in healthy controls, with reduced levels in hereditary hemochromatosis (P < 0.000005) and elevated levels in inflammation (P < 0.0007). In summary a validated method has been developed for the determination of hepcidin concentrations in clinical samples. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

17.
18.
19.
20.
We have designed a semi‐online liquid chromatography/matrix‐assisted laser desorption/ionization mass spectrometry (LC/MALDI‐MS) system to introduce eluent from a octadecylsilyl (ODS) group modified monolithic silica capillary chromatographic column directly onto a sample plate for MALDI‐MS analysis. Our novel semi‐online system is useful for rapidly and sensitively examining the performance of a monolithic capillary column. An additional advantage is the small elution volume of a monolithic capillary column, which allows delicate eluents, such as 1,1,1,3,3,3,‐hexafluoroisopropyl alcohol (HFIP), to be used to achieve cost‐effective analysis. Using the semi‐online LC/MALDI‐MS system, chromatographic separation of polymers by the monolithic column with different eluents was studied. Separation of poly(methyl methacrylate) and Nylon 6/6 showed that the column functioned via size‐exclusion separation when tetrahydrofuran or HFIP eluent was used. On the other hand, the separation behavior of Nylon 11 indicated a reversed‐phase mode owing to the interaction of the polymer with the modified ODS group in the column. Using tetrahydrofuran/methanol (1:1, v/v) as the eluent, the LC/MALDI‐MS spectra of poly(lactic acid), which contains both linear and cyclic polymer structures, showed that the column could separate the hydrophobic cyclic polymer and elute it out relatively slowly. The monolithic column functions basically via size‐exclusion separation; the reversed‐phase separation by interaction with the ODS functions may have less influence on column separation. The semi‐online monolithic capillary LC/MALDI‐MS method we have developed should provide a means of effectively analyzing synthetic polymers. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号