首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper presents a study of EOF properties of plasma‐polymerized microchannel surfaces and the effects of protein (fibrinogen and lysozyme) adsorption on the EOF behavior of the surface‐modified microchannels. Three plasma polymer surfaces, i.e. tetraglyme, acrylic acid and allylamine, are tested. Results indicate EOF suppression in all plasma‐coated channels compared with the uncoated glass microchannel surfaces. The EOF behaviors of the modified microchannels after exposure to protein solutions are also investigated and show that even low levels of protein adsorption can significantly influence EOF behavior, and in some cases, result in the reversal of flow. The results also highlight that EOF measurement can be used as a method for detecting the presence of proteins within microchannels at low surface coverage (<1 ng/cm2 on glass). Critically, the results illustrate that the non‐fouling tetraglyme plasma polymer is able to sustain EOF. Comparison of the plasma‐polymerized surfaces with conventionally grafted polyelectrolyte surfaces demonstrates the stabilities of the plasma polymer films, enabling multiple EOF runs over 3 days without deterioration in performance. The results of this study clearly demonstrate that plasma polymers enable the surface chemistry of microfluidic devices to be tailored for specific applications. Critically, the deposition of the non‐fouling tetraglyme coating enables stable EOF to be induced in the presence of protein.  相似文献   

2.
An electroosmotic flow (EOF)-switchable poly(dimethylsiloxane) (PDMS) microfluidic channel modified with cysteine has been developed. The native PDMS channel was coated with poly(diallyldimethylammonium chloride) (PDDA), and then gold nanoparticles by layer-by-layer technique was assembled on PDDA to immobilize cysteine. The assembly was followed by infrared spectroscopy/attenuated total reflection method, contact angle, EOF measurements and electrophoretic separation methods. EOF of this channel can be reversibly switched by varying the pH of running buffer. At low pH, the surface of channels is positively charged, EOF is from cathode to anode. At high pH, the surface is negatively charged, EOF is from anode to cathode. At pH 5.0, near the isoelectric point of the chemisorbed cysteine, the surfaces of channels show neutral. When pH is above 6.0 or below 4.0, the magnitude of EOF varies in a narrow range. And the modified channel surface displayed high reproducibility and good stability, a good reversibility of cathodic-anodic EOF transition under the different pH conditions was observed. Separation of dopamine and epinephrine as well as arginine and histidine were performed on the modified chip.  相似文献   

3.
Liu B  Lin D  Xu L  Lei Y  Bo Q  Shou C 《色谱》2012,30(5):440-444
利用亲水性超支化聚酰胺酯通过化学键合的方法对聚甲基丙烯酸甲酯(PMMA)微流控芯片的表面进行改性。对改性后PMMA微流控芯片的表面进行了接触角的测定,利用扫描电子显微镜(SEM)和体视显微镜观察了改性后芯片的表面形貌。结果表明,改性后的PMMA微流控芯片表面形成了一层均匀、致密、连续的亲水性涂层,芯片表面的亲水性得到了明显提高,接触角由未改性时的89.9°降低到29.5°。改性后芯片的电渗流较之改性前明显降低。利用芯片对腺苷和L-赖氨酸两种生物分子进行了分离检测。两种生物分子实现了完全分离,所得到的检测峰峰形尖锐,分离清晰。对腺苷和L-赖氨酸的分离柱效(理论塔板数)分别高达8.44×104 塔板/m和9.82×104 塔板/m,分离度(Rs)达到5.31,均远远高于未改性的芯片。改性后的芯片具有良好的分离时间重现性。本研究为提高PMMA微流控芯片的亲水性和应用范围提供了一种新的有效方法。  相似文献   

4.
Surface modification of polymer materials for preparing microfluidic devices including poly(dimethyl siloxane) (PDMS) was investigated with phospholipids polymers such as poly(2-methacryloyloxylethyl phosphorylcholine(MPC)-co-n-butyl methacrylate) (PMB) and poly(MPC-co-2-ethylhexyl methacrylate-co-2-(N,N-dimethylamino)ethyl methacrylate) (PMED). The hydrophilicity of every surface on the polymer materials modified with these MPC polymers increased and the value of zeta-potential became close to zero. The protein adsorption on the polymer materials with and without the surface modification was evaluated using a protein mixture of human plasma fibrinogen and serum albumin. Amount of proteins adsorbed on these polymeric materials showed significant reduction by the surface modification with the MPC polymers compared to the uncoated surfaces ranging from 56 to 90%. Furthermore, we successfully prepared PDMS-based microchannel which was modified by simple coating with the PMB and PMED. The modified microchannel also revealed a significant reduction of adsorption of serum albumin. We conclude that the MPC polymers are useful for reducing unfavorable protein adsorption on microfluidic devices.  相似文献   

5.
Sun X  Liu J  Lee ML 《Electrophoresis》2008,29(13):2760-2767
In-channel atom transfer radical polymerization (ATRP) was used to graft a PEG layer on the surface of microchannels formed in poly(glycidyl methacrylate)-co-(methyl methacrylate) (PGMAMMA) microfluidic devices. The patterned and cover plates were first anchored with ATRP initiator and then thermally bonded together, followed by pumping a solution containing monomer, catalyst, and ligand into the channel to perform ATRP. A PEG-functionalized layer was grafted on the microchannel wall, which resists protein adsorption. X-ray photoelectron spectroscopy (XPS) was used to investigate the initiator-bound surface, and EOF was measured to evaluate the PEG-grafted PGMAMMA microchannel. Fast, efficient, and reproducible separations of amino acids, peptides, and proteins were obtained using the resultant microdevices. Separation efficiencies were higher than 1.0x10(4) plates for a 3.5 cm separation microchannel. Compared with microdevices modified using a previously reported ATRP technique, these in-channel modified microdevices demonstrated better long-term stability.  相似文献   

6.
J S Buch  P C Wang  D L DeVoe  C S Lee 《Electrophoresis》2001,22(18):3902-3907
The application of the field-effect for direct control of electroosmosis in a polydimethylsiloxane (PDMS)-based microfluidic system, constructed on a silicon wafer with a 2.0 microm electrically insulating layer of silicon dioxide, is demonstrated. This microfluidic system consists of a 2.0 cm open microchannel fabricated on a PDMS slab, which can reversibly adhere to the silicon wafer to form a hybrid microfluidic device. Aside from mechanically serving as a robust bottom substrate to seal the channel and support the microfluidic system, the silicon wafer is exploited to achieve field-effect flow control by grounding the semiconductive silicon medium. When an electric field is applied through the channel, a radial electric potential gradient is created across the silicon dioxide layer that allows for direct control of the zeta potential and the resulting electroosmotic flow (EOF). By configuring this microfluidic system with two power supplies at both ends of the microchannel, the applied electric potentials can be varied for manipulating the polarity and the magnitude of the radial electric potential gradient across the silicon dioxide layer. At the same time, the longitudinal potential gradient through the microchannel, which is used to induce EOF, is held constant. The results of EOF control in this hybrid microfluidic system are presented for phosphate buffer at pH 3 and pH 5. It is also demonstrated that EOF control can be performed at higher solution pH of 6 and 7.4 by modifying the silicon wafer surface with cetyltrimethylammonium bromide (CTAB) prior to assembly of the hybrid microfluidic system. Results of EOF control from this study are compared with those reported in the literature involving the use of other microfluidic devices under comparable solution conditions.  相似文献   

7.
Vaidya B  Soper SA  McCarley RL 《The Analyst》2002,127(10):1289-1292
Poly(carbonate), PC, surfaces are chemically modified by treatment with sulfur trioxide gas. Sulfur trioxide gas sulfonates the aromatic rings of the poly(carbonate) surfaces, making the surfaces more hydrophilic. Sulfonation of the poly(carbonate) surface is confirmed by infrared spectroscopy. The modified polymer surfaces are found to be smoother in comparison to their unmodified counterparts, as noted by scanning force microscopy. The effects of the surface modification on electroosmotic flow are studied at a pH range of 4-10. The electroosmotic flow in sulfonated poly(carbonate) microchannels was found to be significantly higher than that in unmodified poly(carbonate) microchannels at pH values below 8.  相似文献   

8.
The necessity for microchannel wall coatings in capillary and chip-based electrophoretic analysis of biomolecules is well understood. The regulation or elimination of EOF and the prevention of analyte adsorption is essential for the rapid, efficient separation of proteins and DNA within microchannels. Microchannel wall coatings and other wall modifications are especially critical for protein separations, both in fused-silica capillaries, and in glass or polymeric microfluidic devices. In this review, we present a discussion of recent advances in microchannel wall coatings of three major classes--covalently linked polymeric coatings, physically adsorbed polymeric coatings, and small molecule additives. We also briefly review modifications useful for polymeric microfluidic devices. Within each category of wall coatings, we discuss those used to eliminate EOF, to tune EOF, to prevent analyte adsorption, or to perform multiple functions. The knowledgeable application of the most promising recent developments in this area will allow for the separation of complex protein mixtures and for the development of novel microchannel wall modifications.  相似文献   

9.
Characterization of SU-8 for electrokinetic microfluidic applications   总被引:1,自引:0,他引:1  
The characterization of SU-8 microchannels for electrokinetic microfluidic applications is reported. The electroosmotic (EO) mobility in SU-8 microchannels was determined with respect to pH and ionic strength by the current monitoring method. Extensive electroosmotic flow (EOF), equal to that for glass microchannels, was observed at pH > or =4. The highest EO mobility was detected at pH > or =7 and was of the order of 5.8 x 10(-4) cm(2) V(-1) s(-1) in 10 mM phosphate buffer. At pH < or =3 the electroosmotic flow was shown to reverse towards the anode and to reach a magnitude of 1.8 x 10(-4) cm(2) V(-1) s(-1) in 10 mM phosphate buffer (pH 2). Also the zeta-potential on the SU-8 surface was determined, employing lithographically defined SU-8 microparticles for which a similar pH dependence was observed. SU-8 microchannels were shown to perform repeateably from day to day and no aging effects were observed in long-term use.  相似文献   

10.
Okanda FM  El Rassi Z 《Electrophoresis》2005,26(10):1988-1995
A neutral, nonpolar monolithic capillary column having a relatively strong electroosmotic flow (EOF) yet free of electrostatic interactions with charged solutes was developed for the reversed-phase capillary electrochromatography (RP-CEC) of neutral and charged species including peptides and proteins. The neutral nonpolar monolith is based on the in situ polymerization of pentaerythritol diacrylate monostearate (PEDAS) in a ternary porogenic solvent composed of cyclohexanol, ethylene glycol, and water. PEDAS plays the role of both the cross-linker and the ligand provider, generating a macroporous nonpolar monolith having C17 chains as the chromatographic ligands. Despite the fact that the neutral PEDAS monolith is devoid of fixed charges, the monolithic capillary columns exhibited a relatively strong EOF due to the ability of PEDAS to adsorb sufficient amounts of electrolyte ions from the mobile phase. The adsorbed ions imparted the neutral PEDAS monolith the zeta potential necessary to support the EOF required for mass transport across the monolithic column. The absence of fixed charges on the surface of the neutral PEDAS monolith and in turn the adsorption sites for electrostatic attraction of charged solutes allowed the rapid and efficient separations of proteins and peptides at pH 7.0, with an average plate number of 255,000 and 121,000 plates/m, respectively. To the best of our knowledge, this constitutes the first report on the separation of proteins at neutral pH by RP-CEC using a neutral monolithic column.  相似文献   

11.
The fabrication of microchannels in poly(ethylene terephthalate glycol) (PETG) by laser ablation and the hot imprinting method is described. In addition, hot imprinted microchannels were hydrolyzed to yield additional charged organic functional groups on the imprinted surface. The charged groups are carboxylate moieties that were also used as a means for the further reaction of different chemical species on the surface of the PETG microchannels. The microchannels were characterized by fluorescence mapping and electroosmotic flow (EOF) measurements. Experimental results demonstrated that different fabrication and channel treatment protocols resulted in different EOF rates. Laser-ablated channels had similar EOF rates (5.3+/-0.3 x 10(-4) cm(2)/Vs and 5.6+/-0.4 x 10(-4) cm(2)/Vs) to hydrolyzed imprinted channels (5.1+/-0.4 x 10(-4) cm(2)/Vs), which in turn demonstrated a somewhat higher flow rate than imprinted PETG channels that were not hydrolyzed (3.5+/-0.3 x 10(-4) cm(2)/Vs). Laser-ablated channels that had been chemically modified to yield amines displayed an EOF rate of 3.38+/- 0.1 x 10(-4) cm(2)/Vs and hydrolyzed imprinted channels that had been chemically derivatized to yield amines showed an EOF rate of 2.67+/-0.6 cm(2)/Vs. These data demonstrate that surface-bound carboxylate species can be used as a template for further chemical reactions in addition to changing the EOF mobility within microchannels.  相似文献   

12.
The widespread interest in micro total analysis systems has resulted in efforts to develop devices in cheaper polymer materials such as polydimethylsiloxane (PDMS) as an alternative to expensive glass and silicon devices. We describe the oxidation of the PDMS surface to form ionizable groups using a discharge from a Tesla coil and subsequent chemical modification to augment electroosmotic flow (EOF) within the microfluidic devices. The flow performance of oxidized, amine-modified and unmodified PDMS materials has been determined and directly compared to conventional glass devices. Exact PDMS replicas of glass substrates were prepared using a novel two step micromolding protocol. Chemical force microscopy has been utilized to monitor and measure the efficacy of surface modification yielding information about the acid/base properties of the modified and unmodified surfaces. Results with different substrate materials correlates well with expected flow modifications as a result of surface modification. Oxidized PDMS devices were found to support faster EOF (twice that of native PDMS) similar to glass while those derivatized with 3-aminopropyl triethoxysilane (APTES) showed slower flow rates compared to native PDMS substrates as a result of masking surface charge. Results demonstrate that the surface of PDMS microdevices can be manipulated to control EOF characteristics using a facile surface derivatization methodology allowing surfaces to be tailored for specific microfluidic applications and characterized with chemical force microscopy.  相似文献   

13.
We report the chemical modification of poly(methyl methacrylate) (PMMA), and poly(carbonate) (PC) surfaces for applications in microfluidic systems. For PMMA, a reaction of the surface methyl ester groups with a monoanion of α,ω-diaminoalkanes (aminolysis reaction) to yield amine-terminated PMMA surfaces will be described. Furthermore, it was found that the amine functionalities were tethered to the PMMA backbone through an alkane bridge to amide bonds formed during the aminolysis of the surface ester functionalities. The electro-osmotic flow (EOF) in aminated-PMMA microchannels was reversed when compared to that in unmodified channels. Finally, the availability of the surface amine groups was further demonstrated by their reaction with n-octadecane-1-isocyanate to form PMMA surfaces terminated with well ordered and highly crystalline octadecane chains, appropriate for performing reverse-phase separations. Examples of reverse-phase separations of ion-paired double-stranded DNAs in electric fields (capillary electrochromatography (CEC)) will be demonstrated using a PMMA-based fluidic chip. For PC, sulfonation of the surface with SO3 will be described; this sulfonation makes the surface very hydrophilic. EOF studies of the sulfonated-PC surfaces indicated changes in the pH-dependent profile when compared to unmodified PC.  相似文献   

14.
Lysozyme is a globular protein which is known to bind to negatively charged phospholipid vesicles. In order to study the relationship between charge state of the protein and its interaction with negatively charged phospholipid membranes chemical modifications of the proteins were carried out. Succinylation and carbodiimide modification was used to shift the isoelectric point of lysozyme to lower and higher pH values, respectively. The binding of the modified lysozyme to phospholipid vesicles prepared from phosphatidic acid (PA) was determined using microelectrophoresis and ultracentrifugation. At acidic pH of the solution all lysozyme species reduced the surface charges of PA vesicles. Succinylated lysozyme (succ lysozyme) reduced the electrophoretic mobility (EPM) to nearly zero, whereas native lysozyme and carboxylated lysozyme (carbo lysozyme) changed the surface charge to positive values. At neutral pH, the reduction of surface charges was less for carbo lysozyme and unmodified lysozyme. Succ lysozyme did not change the EPM. Unmodified and carbo lysozyme decreased the magnitude of EPM, but the whole complex was still negatively charged. The bound fraction of all modified lysozyme to PA vesicles at high lysozyme/PA ratios was nearly constant at acidic pH. At low lysozyme/PA ratios the extent of bound lysozyme is changed in the order carbo>unmodified>succ lysozyme. Increasing the pH, the extent of bound lysozyme to PA large unilamellar vesicles (LUV) is reduced, at pH 9.0 only 35% of carbo lysozyme, 23% of unmodified lysozyme is bound, whereas succ lysozyme does not bind at pH 7.4 and 9.0. At low pH, addition of all lysozyme species resulted in a massive aggregation of PA liposomes, at neutral pH aggregation occurs at much higher lysozyme/PA ratios. Lysozyme binding to PA vesicles is accompanied by the penetration of lysozyme into the phospholipid membrane as measured by monolayer techniques. The penetration of lysozyme into the monolayer was modulated by pH and ionic strengths. The interaction of lysozyme with negatively charged vesicles leads to a decrease of the phospholipid vesicle surface hydration as measured by the shift of the maximum of the fluorescence signal of a headgroup labeled phospholipid. The binding of bis-ANS as an additional indicator for the change of surface hydrophobicity is increased at low pH after addition of lysozyme to the vesicles. More hydrophobic patches of the lysozyme-PA complex are exposed at low pH. At low pH the binding process of lysozyme to PA vesicles is followed by an extensive intermixing of phospholipids between the aggregated vesicles, accompanied by a massive leakage of the vesicle aqueous content. The extent of lysozyme interaction with PA LUV at neutral and acidic pH is in the order carbo lysozyme>lysozyme>succ lysozyme.  相似文献   

15.
The surface properties of microfluidic devices play an important role in their flow behavior. We report here on an effective control of the surface chemistry and performance of polymeric microchips through a bulk modification route during the fabrication process. The new protocol is based on modification of the bulk microchip material by tailored copolymerization of monomers during atmospheric-pressure molding. A judicious addition of a modifier to the primary monomer solution thus imparts attractive properties to the plastic microchip substrate, including significant enhancement and/or modulation of the EOF (with flow velocities comparable to those of glass), a strong pH sensitivity and high stability. Carboxy, sulfo, and amino moieties have thus been introduced (through the incorporation of methylacrylic acid, 2-sulfoethyl-methacrylate and 2-aminoethyl-methacrylate monomers, respectively). A strong increase in the electroosmotic pumping compared to the native poly(methylmethacrylate)(PMMA) microchip (ca. electroosmotic mobility increases from 2.12 to 4.30 x 10(-4) cm(2) V(-1) s(-1)) is observed using a 6% methylacrylate (MAA) modified PMMA microchip. A 3% aminoethyl modified PMMA microchip exhibits a reversal of the electroosmotic mobility (for example, -5.6 x 10(-4) cm(2) V(-1) s(-1) at pH 3.0). The effects of the modifier loading and the pH on the EOF have been investigated for the MAA-modified PMMA chips. The bulk-modified devices exhibit reproducible and stable EOF behavior. The one step fabrication/modification protocol should further facilitate the widespread production of high-performance plastic microchip devices.  相似文献   

16.
Poly(dimethylsiloxane) (PDMS) is an attractive material for microelectrophoretic applications because of its ease of fabrication, low cost, and optical transparency. However, its use remains limited compared to that of glass. A major reason is the difficulty of tailoring the surface properties of PDMS. We demonstrate UV grafting of co-mixed monomers to customize the surface properties of PDMS microfluidic channels in a simple one-step process. By co-mixing a neutral monomer with a charged monomer in different ratios, properties between those of the neutral monomer and those of the charged monomer could be selected. Mixtures of four different neutral monomers and two different charged monomers were grafted onto PDMS surfaces. Functional microchannels were fabricated from PDMS halves grafted with each of the different mixtures. By varying the concentration of the charged monomer, microchannels with electrophoretic mobilities between +4 x 10(-4) cm2/(V s) and -2 x 10(-4) cm2/(V s) were attainable. In addition, both the contact angle of the coated surfaces and the electrophoretic mobility of the coated microchannels were stable over time and upon exposure to air. By carefully selecting mixtures ofmonomers with the appropriate properties, it may be possible to tailor the surface of PDMS for a large number of different applications.  相似文献   

17.
Yan D  Yang C  Nguyen NT  Huang X 《Electrophoresis》2006,27(3):620-627
The zeta potentials of channel surfaces and tracer particles are of importance to the design of electrokinetic microfluidic devices, the characterization of channel materials, and the quantification of the microparticle image velocimetry (microPIV) measurement of EOFs. A method is proposed to simultaneously measure the zeta potentials of the channel surface and the tracer particles in aqueous solutions using the microPIV technique. Through the measurement of the steady velocity distributions of the tracer particles in both open- and closed-end rectangular microchannels under the same water chemistry condition, the electrophoretic velocity of the tracer particles and the EOF field of the microchannel are determined using the expressions derived in this study for the velocity distributions of charged tracer particles in the open- and closed-end rectangular microchannels. Thus, the zeta potentials of the tracer particles and the channel surfaces are simultaneously obtained using the least-square method to fit the microPIV measured velocity distribution of the tracer particles. Measurements were carried out with a microPIV system to determine the zeta potentials of the channel wall and the fluorescent tracer particles in deionized water and sodium chloride and boric acid solutions of various concentrations.  相似文献   

18.
In this work, a piece of glass fiber was inserted into the channel of a poly(methyl methacrylate) (PMMA) electrophoresis microchip to enhance the electroosmotic flow (EOF) and the separation efficiency. The EOF value of the glass fiber-containing microchannel at pH 8.2 was determined to be 4.17 x 10(-4)cm2 V(-1)s(-1). The performance of the new microchip was demonstrated by its ability to separate and detect three purines coupled with end-column amperometric detection. In addition, a piece of trypsin-immobilized glass fiber was inserted into the channel of a PMMA microchip to fabricate a core-changeable microfluidic bioreactor that can be regenerated by changing the fiber. The in-channel fiber bioreactor has been coupled with matrix-assisted laser desorption ionization time-of-flight mass spectrometry for the digestion and peptide mapping of bovine serum albumin and myoglobin.  相似文献   

19.
Unni HN  Keh HJ  Yang C 《Electrophoresis》2007,28(4):658-664
Electrokinetically driven microfluidic devices that are used for biological cell/particle manipulation (e.g., cell sorting, separation) involve electrokinetic transport of these particles in microchannels whose dimension is comparable with particles' size. This paper presents an analytical study on electrokinetic transport of a charged spherical particle in a charged parallel-plate microchannel. Under the thin electric double-layer assumption, solutions in closed-form solutions for the particle velocity and disturbed electrical and fluid velocity fields are obtained for plane-symmetric (along the channel centerline) and asymmetric (off the channel centerline) motions of a sphere in a parallel-plate microchannel. The effects of relative particle size and eccentricity (i.e., off the centerline distance) on a particle's translational and rotational velocities are analyzed.  相似文献   

20.
Electroosmotic flow (EOF) was determined in tridimensional (3D)-printed microchannels with dimensions smaller than 100 µm. Fused deposition modeling 3D printing using thermoplastic filaments of PETG (polyethylene terephthalate glycol), PLA (polylactic acid), and ABS (acrylonitrile butadiene styrene) were used to fabricate the microchannels. The current monitoring method and sodium phosphate solutions at different pH values (3–10) were used for the EOF mobility (µEOF) measurements, which ranged from 2.00 × 10−4 to 12.52 × 10−4 cm2 V−1 s−1. The highest and the smallest µEOF were obtained for the PLA and PETG microchannels, respectively. Adding the cationic surfactant cetyltrimethylammonium bromide to the sodium phosphate solution caused EOF direction reversion in all the studied microchannels. The obtained results can be interesting for developing 3D-printed microfluidic devices, in which EOF is relevant.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号