首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A novel method for the preparation of covalently linked capillary coatings of PVA was demonstrated using photosensitive diazoresin (DR) as coupling agents. Layer‐by‐layer self‐assembly film of DR and PVA based on hydrogen bonding was first fabricated on the inner wall of capillary, then the hydrogen bonding was converted into covalent bonding after treatment with UV light through the unique photochemistry reaction of DR. The covalently bonded coatings suppressed basic protein adsorption on the inner surface of capillary, and thus a baseline separation of lysozyme, cytochrome c and BSA was achieved using CE. Compared with bare capillary or noncovalently bonded DR/PVA coatings, the covalently linked DR/PVA capillary coatings not only improved the CE separation performance for proteins, but also exhibited good stability and repeatability. Due to the replacement of highly toxic and moisture‐sensitive silane coupling agent by DR in the covalent coating preparation, this method may provide a green and easy way to make the covalently coated capillaries for CE.  相似文献   

2.
Yang R  Shi R  Peng S  Zhou D  Liu H  Wang Y 《Electrophoresis》2008,29(7):1460-1466
We present cationized hydroxyethylcellulose (cat-HEC) synthesized in our laboratory as a novel physically adsorbed coating for CE. This capillary coating is simple and easy to obtain as it only requires flushing the capillary with polymer aqueous solution. A comparative study with and without polymers was performed. The adsorbed cat-HEC coating exhibited minimal interactions with basic proteins, providing efficient basic protein separations with excellent reproducibility. Under broad pHs, the amine groups are the main charged groups bringing about a global positive charge on the capillary wall. As a consequence, the cat-HEC coating produced an anodal EOF performance. A comparative study on the use of hydroxyethylcellulose (HEC) and cat-HEC as physically adsorbed coatings for CE are also presented. The separation efficiency and analysis reproducibility proved that the cat-HEC polymer was efficient in suppressing the adsorption of basic proteins onto the silica capillary wall. The long-term stability of the cat-HEC coating in consecutive protein separation runs has demonstrated the suitability of the coating for high-throughput electrophoretic protein separations.  相似文献   

3.
In this work, the properties of four cationic copolymers synthesized in our laboratory are studied as physically adsorbed coatings for capillary electrophoresis (CE). Namely, the four copolymers investigated were poly(N-ethyl morpholine methacrylamide-co-N,N-dimethylacrylamide), poly(N-ethyl pyrrolidine methacrylate-co-N,N-dimethylacrylamide), poly(N-ethyl morpholine methacrylate-co-N,N-dimethylacrylamide) and poly(N-ethyl pyrrolidine methacrylamide-co-N,N-dimethylacrylamide). Capillaries were easily coated using these four different macromolecules by simply flushing into the tubing an aqueous solution containing the copolymer. The stability and reproducibility of each coating were tested for the same day, different days and different capillaries. It is demonstrated that the use of these coatings in CE can drastically reduce the analysis time, improve the resolution of the separations or enhance the analysis repeatability at very acidic pH values compared to bare silica columns. As an example, the analysis of an organic acids test mixture revealed that the analysis time was reduced more than 6-times whereas the separation efficiency was significantly increased to nearly 10-times attaining values up to 595,000 plates/m using the coated capillaries. Moreover, it was shown that all the copolymers used as coatings for CE allowed the separation of basic proteins by reducing their adsorption onto the capillary wall. Links between their molecular structure, physicochemical properties and their performance as coatings in CE are discussed.  相似文献   

4.
Two novel polysiloxanes containing the metal complex, Co(TACN)(3+)2 (TACN= 1,4,7-triazacyclononane) were used as coatings for capillary electrophoresis (CE) and capillary electrochromatography (CEC). Through crosslinking and covalent bonding, the positively charged polymers were bonded to silica supports. In both CE and CEC, these coatings exhibited strong, pH-independent, and anodic electroosmotic flow (EOF), and had excellent long-term stability. Successful separations of aromatic acids were achieved in CE. In CEC, separation of alkylbenzenes (7 min) and basic compounds (20 min) was achieved with higher resolving power than conventional octadecyl silica packings. These polymers represent a new class of coatings for CE and CEC that generate pH-independent EOF.  相似文献   

5.
CE offers the advantage of flexibility and method development options. It excels in the area of separation of ions, chiral, polar and biological compounds (especially proteins and peptides). Masking the active sites on the inner surface of a bare fused silica capillary wall is often necessary for CE separations of basic compounds, proteins and peptides. The use of capillary surface coating is one of the approaches to prevent the adsorption phenomena and improve the repeatability of migration times and peak areas of these analytes. In this study, new capillary coatings consisting of (i) derivatized polystyrene nanoparticles and (ii) derivatized fullerenes were investigated for the analysis of peptides and protein digest by CE. The coated capillaries showed excellent run‐to‐run and batch‐to‐batch reproducibility (RSD of migration time ≤0.5% for run‐to‐run and ≤9.5% for batch‐to‐batch experiments). Furthermore, the capillaries offer high stability from pH 2.0 to 10.0. The actual potential of the coated capillaries was tested by combining CE with MALDI‐MS for analysing complex samples, such as peptides, whereas the overall performance of the CE‐MALDI‐MS system was investigated by analysing a five‐protein digest mixture. Subsequently, the peak list (peptide mass fingerprint) generated from the mass spectra of each fraction was entered into the Swiss‐Prot database in order to search for matching tryptic fragments using the MASCOT software. The sequence coverage of analysed proteins was between 36 and 68%. The established technology benefits from the synergism of high separation efficiency and the structure selective identification via MS.  相似文献   

6.
Numerous efforts have been made to separate proteins by capillary zone electrophoresis (CZE). The most common optimization techniques are changing the pH of the running buffer, coating the capillary surface with a hydrophilic polymer, or using additives in the sample solution. Surface coatings and solution additives can reduce the adsorption of the protein onto the capillary surface, but they diminish the separation efficiency and the resolution of CZE. This paper reports the successful separation of proteins in a untreated fused-silica capillary by raising the pH of the running buffer and washing between runs with 1.0 M sodium hydroxide. Under these conditions, model proteins and proteins in human serum have been determined by CZE. It is shown that the results from CZE are compatible with those of sodium dodecyl sulphate-polyacrylamide gel electrophoresis.  相似文献   

7.
In this work, a new physically adsorbed coating for capillary electrophoresis (CE) is presented. The coating is based on a N,N-dimethylacrylamide-ethylpyrrolidine methacrylate (DMA-EPyM) copolymer synthesized in our laboratory. The capillary coating is simple and easy to obtain as only requires flushing the capillary with a polymer aqueous solution for 2 min. It is shown that by using these coated capillaries the electrostatic adsorption of a group of basic proteins onto the capillary wall is significantly reduced allowing their analysis by CE. Moreover, the DMA-EPyM coating provides reproducible separations of the basic proteins with RSD values for migration times lower than 0.75% for the same day (n = 5) and lower than 3.90% for three different days (n = 15). Interestingly, the electrical charge of the coated capillary wall can be modulated by varying the pH of the running buffer which makes possible the analysis of basic and acidic proteins in the same capillary. The usefulness of this coating is further demonstrated via the reproducible separation of whey (i.e. acidic) proteins from raw milk. The coating protocol should be compatible with both CE in microchips and CE-MS of different types of proteins.  相似文献   

8.
The capillary walls of fused-silica capillary electrophoresis (CE) columns were modified with a thin film of polyaniline (PANI), providing open-tubular columns with a stable coating containing aromatic groups and amine functionalities. Fast and efficient separations were observed for small bioactive peptides under acidic conditions on PANI-coated columns. The mechanism of separation is based on hydrophobic interactions between the analytes and the polymeric matrix. Good reproducibility was observed from run-to-run. Due to the simple derivatization procedure, method flexibility, the uniformity of the coating and its stability, conjugated polymers could find practical application in capillary zone electrophoresis (CZE) separations.  相似文献   

9.
In this work, a facile approach was developed to modify a fused‐silica capillary inner surface based on poly(dopamine) and poly(acrylamide) mixed coatings for protein separation by capillary electrophoresis. The surface morphology, thickness, and chemical components of poly(dopamine)/poly(acrylamide) mixed coatings on glass slides and silicon wafers were studied by atom force microscopy, ellipsometry, and X‐ray photoelectron spectroscopy, respectively. The hydrophilicity and stability of the mixed coatings on glass slides were investigated by static water contact angle measurements. A comparative study of electroosmotic flow showed that the poly(dopamine)/poly(acrylamide) mixed coatings could provide effective suppression of electroosmotic flow. Meanwhile, the fast and efficient separations of the mixture of four alkaline proteins, the mixture of acidic, basic, and neutral proteins and egg white proteins were obtained by capillary electrophoresis. Furthermore, the consecutive protein separation runs and low RSDs of migration time demonstrated that these poly(dopamine)/poly(acrylamide) mixed coatings were capable of minimizing protein adsorption during the protein separation by using capillary electrophoresis.  相似文献   

10.
A new method for protein analysis, that is, electroosmotic pump-assisted capillary electrophoresis (EOPACE), is developed and demonstrated to possess several advantages over other CE-based techniques. The column employed in EOPACE consists of two linked sections, poly(vinyl alcohol) (PVA)-coated and uncoated capillaries. The PVA-coated capillary column is the section for protein electrophoresis in EOPACE. Electroosmotic flow (EOF) is almost completely suppressed in this hydrophilic polymer coated section, so protein electrophoresis in the PVA-modified capillary is free of irreversible protein adsorption to the capillary inner wall. The uncoated capillary section serves as an electroosmotic pump, since EOF towards cathode occurs at neutral pH in the naked silica capillary. By the separation of a protein mixture containing cytochrome c (Cyt-c), myoglobin and trypsin inhibitor, we have demonstrated the advantages of EOPACE method over other relevant ones such as pressure assisted CE, capillary zone electrophoresis (CZE) with naked capillary and CZE with PVA-coated capillary. A significant feature of EOPACE is that simultaneous separation of cationic, anionic and uncharged proteins at neutral pH can be readily accomplished by a single run, which is impossible or difficult to realize by the other CE-based methods. The high column efficiency and good reproducibility in protein analysis by EOPACE are verified and discussed. In addition, separation of tryptic digests of Cyt-c with the EOPACE system is demonstrated.  相似文献   

11.
In this work, a comparative study on the use of different polymers as physically adsorbed coatings for CE is presented. It is demonstrated that the use of ad hoc synthesized polymers as coatings allows tailoring the EOF in CE increasing the flexibility of this analytical technique. Namely, different polymers were synthesized at our laboratory using different percentages of ethylpyrrolidine methacrylate (EpyM) and N,N-dimethylacrylamide (DMA). Thus, by modifying the percentage of EpyM and DMA monomers it is possible to manipulate the positive charge of the copolymer, varying the global electrical charge on the capillary wall and with that the EOF. These coated capillaries are obtained by simply flushing a given EpyM-DMA aqueous solution into bare silica capillaries. It is shown that by using these coated capillaries at adequate pHs, faster or more resolved CE separations can be achieved depending on the requirements of each analysis. Moreover, it is demonstrated that these coated capillaries reduce the electrostatic adsorption of basic proteins onto the capillary wall. Furthermore, EpyM-DMA coatings allow the reproducible chiral separation of enantiomers through the partial filling technique (PFT). The EpyM-DMA coated capillaries are demonstrated to provide reproducible EOF values independently of the pH and polymer composition with%RSD values lower than 2% for the same day. It is also demonstrated that the coating procedure is reproducible between capillaries. The compatibility of this coating protocol with CE in microchips is discussed.  相似文献   

12.
In aqueous capillary electrophoresis, the electroosmotic flow can be strongly suppressed by coating the inner surface of the capillary. In the present work hydrophilic coating of 4% polyvinyl alcohol (PVA) has been used for the analysis of basic proteins. The coating is simple and easy to obtain. The separation of ribonuclease and α-chymotrypsin has been uniquely done with other three basic proteins (lysozyme, cytochrome-c and trypsin) using a buffer 11.60 mM sodium acetate and 18.40 mM acetic acid at pH 4.5 in addition to positive power supply of 20 kV at 25°C. Detection was performed using UV detector at 230 nm. The proposed PVA coated capillary provides reproducible separation of five basic proteins within 10 min with RSD values for mobility bellow 1.4% (n = 6) for all the five basic proteins. The stability of coated capillary has been checked up to 40 runs. The viscosity measurement for 4% PVA have been studied and scanning electron microscope (SEM) images obtained to make it compatible with future micro-chip applications.  相似文献   

13.
Capillary electrophoresis (CE) provides a new analytical tool for the separation of proteins, and almost all traditional modes of electrophoresis can be carry out in CE. But serious adsorption of proteins on capillary wall prohibited the proper separation. Three main approaches are used to overcome adsorption and control electroosmotic flow, (1) buffer of high or low pH,high salt concentration and additives, (2) pre-adsorption of neutral or charged macromolecules on the capillary wall and (3) chemically bonded coatings which are expected to give the best shield of silanol groups present on bare silica by vaious hydrophilic polymers. Capillaries coated with linear polyacrylamide represent the most successful approach available to date. Cross-linkage of polyacrylamide coating is desired to increase its stability.  相似文献   

14.
The effect of different parameters controlling the characteristics of linear polyacrylamide coatings deposited on the inner wall of fused-silica capillaries and their influence on capillary electrophoresis (CE) performance of these coated columns is investigated. To carry out this study, a reproducible procedure to obtain capillaries with similar extent of modification of the surface silanols with 7-oct-1-enyltrimethoxisilane was first approached. Next the polymer attachment to the silica wall, via covalent linkage to the silyl reagent grafted onto the silica, was investigated. In this way, by using columns with a similar silylation extent, differences in CE performance observed among capillaries coated under diverse conditions could be assigned to the characteristics of the polyacrylamide layer. It is demonstrated that the characteristics and reproducibility of these polymeric coatings depend on the adequate control of both the temperature of polymerization and the degassing of the polymerizing dissolutions used. More interestingly, it is also demonstrated that the quantities of monomer (acrylamide), initiator (ammonium persulfate) and activator (N,N,N′,N′-tetramethylethylenediamine), and the ratio among them used in the preparation of the coating polymer have a large influence on the performance of CE columns. The optimum conditions for preparing the polyacrylamide coatings are discussed. The applicability of these linear polyacrylamide-coated capillaries to the separation of basic and acidic proteins in free zone CE is demonstrated. Besides, the use of these coated columns in capillary gel electrophoresis for the separation of DNA fragments is shown.  相似文献   

15.
Many cellular functions are regulated through protein isoforms. Changes in the expression level or regulatory dysfunctions of isoforms often lead to developmental or pathological disorders. Isoforms are traditionally analyzed using techniques such as gel- or capillary-based isoelectric focusing. However, with proper electro-osmotic flow (EOF) control, isoforms with small pI differences can also be analyzed using capillary zone electrophoresis (CZE). Here we demonstrate the ability to quickly resolve isoforms of three model proteins (bovine serum albumin, transferrin, alpha1-antitrypsin) in capillaries coated with novel dynamic coatings. The coatings allow reproducible EOF modulation in the cathodal direction to a level of 10(-9) m2V(-1)s(-1). They also appear to inhibit protein adsorption to the capillary wall, making the isoform separations highly reproducible both in peak areas and apparent mobility. Isoforms of transferrin and alpha1-antitrypsin have been implicated in several human diseases. By coupling the CZE isoform separation with standard affinity capture assays, it may be possible to develop a cost-effective analytical platform for clinical diagnostics.  相似文献   

16.
Du M  Flanagan JH  Lin B  Ma Y 《Electrophoresis》2003,24(18):3147-3153
The detection of point and other simple mutations in DNA is important for cancer research and diagnosis and other biological studies. Capillary electrophoresis has been successfully used for separating DNA fragments. However, a low-viscosity polymer sieving buffer for DNA separation with on-line coating has never been reported. In this paper, a new method using capillary electrophoresis with on-line coating and laser-induced fluorescence detection (CE-LIF) for screening for point or simple DNA mutations has been demonstrated. The method uses an on-line dynamic coating technique that increases capillary lifetime and analysis reproducibility, and employs a low-viscosity polymer solution, which allows the user to rinse the capillary rapidly and refill with polymer solution easily. Experiments proved that the additives in the separation buffer for on-line capillary coating do not affect the separation efficiency of the running buffer, and do not interfere with the formation of hydrogen-bonded network between boric acid, mannitol and hydroxypropylmethylcellulose polymers. The stability of the dynamically coated capillary was quantitatively studied; the capillary lifetime was increased 6- to 7-fold compared with that of permanently coated CE columns. Standard DNA fragments containing mutations, with sizes of 209, 219, and 338 bps, were successfully separated and detected with this system, after the mutated DNA fragments were cleaved by CEL-I endonuclease. The technique is very sensitive for the size-separation of low-range, middle-range, and high-range DNA fragments. Results were compared with the HPLC methods developed by Transgenomic, Inc. and were in good agreement. The method should be applicable to mutation detection for all relevant biological and clinical studies. The factors influencing separations and the stability of dynamic capillary coatings are also discussed in the paper.  相似文献   

17.
Cao F  Luo Z  Zhou D  Zeng R  Wang Y 《Electrophoresis》2011,32(10):1148-1155
In this work, a novel graft copolymer, hydroxyethylcellulose-graft-poly(2-(dimethylamino)ethyl methacrylate) (HEC-g-PDMAEMA), used as physical coatings of the bare fused-silica capillaries, was synthesized by using ceric ammonium nitrate initiator in aqueous nitric acid solution. EOF measurement results showed that the synthesized HEC-g-PDMAEMA graft copolymer-coated capillary in this paper could suppress EOF effectively compared to the bare fused-silica capillary, and efficient separations of basic proteins were also achieved. The electrical charge of the coated capillary wall could be modulated by varying not only the pH of the running buffer, but also the grafting ratio of poly(2-(dimethylamino)ethyl methacrylate) grafts, which makes possible the analysis of basic and acidic proteins in the same capillary. The effects of poly(2-(dimethylamino)ethyl methacrylate) grafting ratio in HEC-g-PDMAEMA and buffer pH on the separation of basic proteins for capillary electrophoresis were investigated in detail. Furthermore, egg white proteins and milk powder samples were separated by the HEC-g-PDMAEMA-coated capillary. The results demonstrated that the HEC-g-PDMAEMA copolymer coatings have great potential in the field of diagnosis and proteomics.  相似文献   

18.
Wall coating for capillary electrophoresis on microchips   总被引:2,自引:0,他引:2  
Dolník V 《Electrophoresis》2004,25(21-22):3589-3601
This review article with 116 references describes recent developments in the preparation of wall coatings for capillary electrophoresis (CE) on a microchip. It deals with both dynamic and permanent coatings and concentrates on the most frequently used microchip materials including glass, poly(methyl methacrylate), poly(dimethyl siloxane), polycarbonate, and poly(ethylene terephthalate glycol). Characterization of the channel surface by measuring electroosmotic mobility and water contact angle of the surface is included as well. The utility of the microchips with coated channels is demonstrated by examples of CE separations on these chips.  相似文献   

19.
毛细管电泳具有分析时间短,分离效率高,样品消耗量少等优点,在生物样品分离,特别是蛋白质分析领域有重要应用。然而,毛细管内壁硅羟基的解离给分离结果带来诸多不良影响。聚合物涂层能够抑制蛋白质在毛细管内壁的吸附以及调控电渗流,故对毛细管内壁进行有效修饰能够提高其对蛋白质的分离效率及分离稳定性。该文主要综述了动态及静态聚合物涂层毛细管的最新研究进展,并概述了近些年基于多巴胺/聚多巴胺发展起来的涂层毛细管的研究进展,最后展望了聚合物涂层毛细管的发展趋势。  相似文献   

20.
Simpson DC  Smith RD 《Electrophoresis》2005,26(7-8):1291-1305
Mass spectrometry (MS)-based proteomics is currently dominated by the analysis of peptides originating either from digestion of proteins separated by two-dimensional gel electrophoresis (2-DE) or from global digestion; the simple peptide mixtures obtained from digestion of gel-separated proteins do not usually require further separation, while the complex peptide mixtures obtained by global digestion are most frequently separated by chromatographic techniques. Capillary electrophoresis (CE) provides alternatives to 2-DE for protein separation and alternatives to chromatography for peptide separation. This review attempts to elucidate how the most promising CE modes, capillary zone electrophoresis (CZE) and capillary isoelectric focusing (CIEF), might best be applied to MS-based proteomics. CE-MS interfacing, mass analyzer performance, column coating to minimize analyte adsorption, and sample stacking for CZE are considered prior to examining numerous applications. Finally, multidimensional systems that incorporate CE techniques are examined; CZE often finds use as a fast, final dimension before ionization for MS, while CIEF, being an equilibrium technique, is well-suited to being the first dimension in automated fractionation systems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号