首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Upon UV irradiation, in O2 saturated aqueous titanium dioxide suspensions, uracil is almost completely mineralised. Most of the organic compounds occurring during the photodegradation process have been identified by means of liquid chromatography and mass spectrometry coupled techniques (LC–MS). The first step of the mineralisation leads to the formation of uracilglycol. Then, the main products generated during the photodegradation exhibit new functions such as polyol, carboxylic and aldehyde. The presence of urea has been clearly evidenced. At the end of the process, the ultimate step is the formation of nitrate and ammonium ions. The formation kinetics of intermediate products are modified by pH variation and CdCl2 addition.  相似文献   

2.
Nanocrstalline pure anatase titania were prepared by sol–gel process at room temperature followed by ultrasonication (Ti–US). The photocatalytic activity of Ti–US has been evaluated by the degradation of textile dye, Methylene Blue in presence and absence of common inorganic salts (NO3, C2O42−, SO42−, citrate). It was observed that, in presence of anions, the degradation of the dye increases significantly. The influence of the presence of H2O2 on the degradation rate was studied. The dependence of photodegradation of the dye rates on various parameters such as dye concentration, photocatalyst concentration and pH were also investigated. The photodegradation rate follows first order kinetics. H2O2 and UV light have a negligible effect in absence of Ti–US catalyst. The relative photonic efficiency of the system is reported using phenol as a standard organic compound.  相似文献   

3.
Cao Q  Li S  He C  Li K  Liu F 《Analytica chimica acta》2007,590(2):187-194
Based on aqueous two-phase system (ATPS) of poly(ethylene glycol) (PEG)–(NH4)2SO4, a simple pretreatment approach was developed for the extraction and determination of papaverin in pericarpium papaveris. The influence factors on phase behavior of the ATPS and partition behavior of papaverin was investigated, and partition mechanism based on the hydrophobic interaction between PEG and analyte molecules was proposed. Under the optimal conditions, the extraction efficiencies for papaverin were 93–96%, and the recoveries of the added standard were 97–106% with relative standard deviations of 1.8–2.5%. Combined with a high-performance liquid chromatography (HPLC) method, this extraction technique has been successfully applied to the determination of papaverin in pericarpium papaveris with the detection limit of 2 ng mL−1 and the linear range of 0.10–10 μg mL−1. Compared with the conventional liquid–liquid extraction or solid-phase extraction, this method was more environmentally benign, more cost effective and much simpler due to the direct injection of the upper phase into HPLC system.  相似文献   

4.
Liu JF  Liang X  Jiang GB  Cai YQ  Zhou QX  Liu GG 《Talanta》2003,60(6):1155-1161
An on-line coupled continuous flow liquid membrane extraction (CFLME) and C18 precolumn system was developed for sample preconcentration in liquid chromatography determination. After preconcentration by CFLME, which is based on the combination of continuous flow liquid–liquid extraction and supported liquid membrane, bisphenol A (BPA) was enriched in 960 μl of 1 mol l−1 NaOH used as acceptor. This acceptor was on-line neutralized and transported onto the C18 precolumn where analytes were absorbed and focused. Then the focused analytes were injected onto a C18 analytical column for separation and detected at 220 nm with a diode array detector. CFLME related parameters such as flow rates, pH of donor and acceptor, and enrichment time were optimized. The proposed method presents a detection limit of 0.03 μg l−1 (S/N=3) when 60 ml samples was enriched with an enrichment time of 30 min. Compared with C18 based column-switching procedure, this proposed procedure presents similar sample throughput and lower detection limits. The proposed method was successfully applied to determine BPA in tap water, river water, and municipal sewage effluent samples.  相似文献   

5.
The photostability of guaiazulene (1,4-dimethyl-7-isopropylazulene; GA), a natural azulenic compound used in cosmetic and health-care products, as well as in pharmaceutical preparations, was investigated in solution (methanol, ethanol, acetonitrile), by different techniques: gas chromatography/mass spectrometry (GC/MS) and high-performance liquid chromatography combined with atmospheric pressure chemical ionization mass spectrometry and UV detection (LC/APCI-MS and HPLC/UV). A solar simulator (xenon-arc lamp) was used as UV-A radiation source. The study involved: monitoring compound decomposition, identifying products of photodegradation (PPs), assessing the role of oxygen and evaluating the kinetics of the process. Minor PPs are volatile compounds and were characterized by GC/MS, while oligomeric polyoxygenated compounds, tentatively characterized on the basis of MS and MS/MS spectra, were found to be the main photoproducts. The photodegradation was found to be enhanced by the presence of oxygen; nevertheless, determination of the singlet oxygen quantum yield for GA gave a lower value than that for the reference standard Rose Bengal. The obtained results and the developed stability-indicating methods (GC/MS and LC/MS) are of interest for stability studies and/or quality control purposes of GA as raw material or cosmetic products.  相似文献   

6.
Applications of solid-phase microextraction in food analysis   总被引:21,自引:0,他引:21  
Food analysis is important for the evaluation of the nutritional value and quality of fresh and processed products, and for monitoring food additives and other toxic contaminants. Sample preparation, such as extraction, concentration and isolation of analytes, greatly influences the reliable and accurate analysis of food. Solid-phase microextraction (SPME) is a new sample preparation technique using a fused-silica fiber that is coated on the outside with an appropriate stationary phase. Analyte in the sample is directly extracted to the fiber coating. The SPME technique can be used routinely in combination with gas chromatography (GC), GC–mass spectrometry (GC–MS), high-performance liquid chromatography (HPLC) or LC–MS. Furthermore, another SPME technique known as in-tube SPME has also been developed for combination with LC or LC–MS using an open tubular fused-silica capillary column as an SPME device instead of SPME fiber. These methods using SPME techniques save preparation time, solvent purchase and disposal costs, and can improve the detection limits. This review summarizes the SPME techniques for coupling with various analytical instruments and the applications of these techniques to food analysis.  相似文献   

7.
An analytical method based on CO2 supercritical fluid extraction (SFE) followed by gas chromatography (GC) was evaluated, compared to Soxhlet extraction, and found to determine accurately and precisely diesel fuel contamination of standard soil samples at a total petroleum hydrocarbon level of 100 μg/g in soil. While both extraction methods have the same 3% relative repeatability standard deviation for determination of total hydrocarbon contamination at this level, SFE requires much less time, uses less organic solvent and provides better recovery of the more volatile n-C10 to n-C12 hydrocarbons.  相似文献   

8.
Polycyclic aromatic sulphur heterocyclic (PASH) compounds, such as dibenzothiophene (DBT) and alkylated derivatives are used as model compounds in biodesulfurization processes. The development of these processes is focused on the reduction of the concentration of sulphur in gasoline and gas–oil [D.J. Monticello, Curr. Opin. Biotechnol. 11 (2000) 540], in order to meet European Union and United States directives.

The evaluation of biodesulfurization processes requires the development of adequate analytical techniques, allowing the identification of any transformation products generated. The identification of intermediates and final products permits the evaluation of the degradation process.

In this work, seven sulfurated compounds and one non-sulfurated compound have been selected to develop an extraction method and to compare the sensitivity and identification capabilities of three different gas chromatography ionization modes. The selected compounds are: dibenzothiophene (DBT), 4-methyl-dibenzothiophene (4-m-DBT), 4,6-dimethyl-dibenzothiophene (4,6-dm-DBT) and 4,6 diethyl-dibenzothiophene (4,6 de-DBT), all of which can be used as model compounds in biodesulfurization processes; as well as dibenzothiophene sulfoxide (DBTO2), dibenzothiophene sulfone (DBTO) and 2-(2-hydroxybiphenyl)-benzenesulfinate (HBPS), which are intermediate products in biodesulfurization processes of DBT [ A. Alcon, V.E. Santos, A.B. Martín, P. Yustos, F. García-Ochoa, Biochem. Eng. J. 26 (2005) 168]. Furthermore, a non-sulfurated compound, 2-hydroxybiphenyl (2-HBP), has also been selected as it is the final product in the biodesulfurization process of DBT [A. Alcon, V.E. Santos, A.B. Martín, P. Yustos, F. García-Ochoa. Biochem. Eng. J. 26 (2005) 168].

Since, typically, biodesulfurization reactions take place in a biphasic medium, two extraction methods have been developed: a liquid–liquid extraction method for the watery phase and a solid phase extraction method for the organic phase. Recoveries of the selected compound in both media were studied. They were in the range of 80–100% for the watery and in the range of 40–60% for the organic phase, respectively.

Gas chromatography coupled to mass spectrometry (GC–MS) has been employed for the identification of these selected compounds. Three different ionization modes were applied: conventional electron impact (EI); positive chemical ionization (PCI), using methane as the reagent gas; and a recently developed ionization mode known as hybrid chemical ionization (HCI), using perfluorotri-n-butylamine as the reagent gas. Limits of detection and identification capabilities have been compared between the three analytical techniques.

The sensitivity of the three analytical techniques was studied and LOD between 0.05 and 1, between 0.09 and 2 and between 0.001 and 0.043 were achieved for PCI, EI and HCI, respectively.

The developed method was applied in samples from a biodesulfurization process. The biodesulfurization reactions were conducted in resting cell operation mode, using Erlenmeyer flasks or an agitated tank bioreactor. The microorganism employed was Pseudomonas putida CECT 5279. The reaction was performed under controlled air flow, stirring and temperature conditions.  相似文献   


9.
10.
An analytical methodology for nifedipine quantitation in plasma by on-line solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) is described. The SPE cartridges contain C2 and the analytes nifedipine and nitrendipine (internal standard) are separated on a C18 column with a mobile phase consisting of acetonitrile–13 mM phosphate buffer pH 7 (65:35, v/v) followed by UV detection at 338 nm. Validation of the method demonstrated good recoveries (>90%), sensitivity (limit of quantification, 2 ng/ml), based on a 500 μl sample volume, accuracy and precision (<5.5% in concentrations greater than the limit of quantitation). This methodology has been used for bioequivalence studies.  相似文献   

11.
Analytical methodologies employed in biodesulfurization processes have been reviewed; attention is primarily focused on the use of analytical techniques in the identification of degradation products and on the monitoring of degradation processes in which microbial sulphur-specific transformations take place. This is the first review of analytical techniques applied to biodesulfurization processes. Methodologies based on gas chromatography (GC) are the most frequently employed, in tandem with various detectors, mainly with the mass spectrometry (MS) detector, and the flame ionization detector (FID). High performance liquid chromatography (HPLC) coupled with ultra violet (UV) detection has also been widely employed. Different sulphurated compounds are used as model in biodesulphurization processes, naphtothiophene (NTH), benzothiophene (BTH), alkilated BTH, dibenzothiophene (DBT), alkilated DBT and their transformation products has been reviewed. DBT is the most frequently employed.  相似文献   

12.
A series of Nd3+, Pr3+, Er3+, and Dy3+ (0.25–5 at.%) homogeneously doped nanocrystalline titanium dioxides (Ln/TiO2) were prepared by an easy sol–gel technique, and the roles of lanthanide doping on the photocatalytic activity in the degradation of rhodamine B (RB) in aqueous solution were studied. Both the concentration of the lanthanide dopant and calcination temperature showed significant effect to the photodegradation of RB. The photocatalytic activity of pure titania was drastically decreased when calcination temperature was at 700 °C, while the high photocatalytic activity was still maintained for lanthanide-doped samples. HPLC-MS method was used to study the degradation process, and it is demonstrated that the degradation of RB catalyzed by Ln/TiO2 was principally go through with a stepwise de-ethylation photochemical process.  相似文献   

13.
Lee YH  Jeong ES  Cho HE  Moon DC 《Talanta》2008,74(5):1615-1620
A comprehensive analytical method was established for the separation of polyethylene glycol (PEG) stearates according to the distribution of ethylene oxide (EO) and subsequent determination of the surfactants in cosmetic samples by using a high-performance liquid chromatography–evaporative light scattering detection. Separation of the PEG stearates comprising approximately up to 82 EO adducts was performed on a reversed-phase YMC-Pack C8 column using water–acetonitrile gradient elution. The PEG oligomers were separated in order of the increasing number of EO adducts. Quantitation of the PEG fatty acid esters, which was separated as single peak per each component, was performed by chromatography on a reversed-phase Wakosil 10 C18 column using water–methanol gradient elution. The standard curve to quantify the PEG stearates was constructed by the log–log plot, which showed good linearity with the correlation coefficients (R2) 0.998 and more. Working range, repeatability, limit of detection and recovery were acceptable for analysis of the surfactants in cosmetic products. The analytical methods were applied to characterize the PEG stearates according to the EO distributions, then to quantify the surfactants in cosmetic products.  相似文献   

14.
Dispersive liquid–liquid microextraction (DLLME) has become a very popular environmentally benign sample-preparation technique, because it is fast, inexpensive, easy to operate with a high enrichment factor and consumes low volume of organic solvent. DLLME is a modified solvent extraction method in which acceptor-to-donor phase ratio is greatly reduced compared with other methods. In this review, in order to encourage further development of DLLME, its combination with different analytical techniques such as gas chromatography (GC), high-performance liquid chromatography (HPLC), inductively coupled plasma-optical emission spectrometry (ICP-OES) and electrothermal atomic absorption spectrometry (ET AAS) will be discussed. Also, its applications in conjunction with different extraction techniques such as solid-phase extraction (SPE), solidification of floating organic drop (SFO) and supercritical fluid extraction (SFE) are summarized. This review focuses on the extra steps in sample preparation for application of DLLME in different matrixes such as food, biological fluids and solid samples. Further, the recent developments in DLLME are presented. DLLME does have some limitations, which will also be discussed in detail. Finally, an outlook on the future of the technique will be given.  相似文献   

15.
This critical overview covers current analytical methods and future developments in quantitative determination of fatty acids (FAs), emphasizing sample extraction, derivatization and instrumental analysis with gas chromatography/mass spectrometry (GC/MS) and high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS2). We compare the benefits and the drawbacks of these two analytical techniques.We consider the well-established GC/MS method with pre-derivatization to be a traditional technique in terms of highly standardized sample-preparation procedures, affordability and readily available library searching for compound identification. However, the complicated derivatization steps required prior to instrumental analysis with GC/MS take a long time, with loss and transformation of FAs, low recovery and poor reproducibility.HPLC/MS2 without derivatization shows the benefits of simple, mild sample-processing conditions, satisfactory recovery, short running time and high selectivity and sensitivity, which may allow it to become a viable alternative to GC/MS for the analysis of FAs in the years ahead.  相似文献   

16.
A general scheme is set up for the estimation of the impurity profile of bulk drug substances by the complex use of chromatographic, spectroscopic and hyphenated techniques. Several examples are presented as illustrations to the scheme from the authors' laboratory involving the use of chromatographic methods such as thin-layer-(TLC), gas-(GC), analytical and preparative high-performance liquid chromatography (HPLC), spectroscopic methods such as mass spectrometry (MS) and NMR spectroscopy as well as hyphenated techniques (HPLC/diode-array UV, GC/MS and HPLC/MS). In addition to summarizing earlier work, new examples are also presented: identification of an impurity (propyl 4-[diethylcarbamoyl(methoxy)]-3-methoxy phenylglyoxylate, II) in propanidid (I) and two unsaturated impurities in allylstrenol (VII) by GC/MS and HPLC/diode-array UV as well as estimation of the impurity profile of mazipredone (III) by HPLC/MS and HPLC/diode-array UV.  相似文献   

17.
The development of analytical methods for routine simultaneous identification and quantification of carboxylic fatty acids (CFAs) are required in different fields, such as, pharmaceutical cosmetics, food products and formulations of water–microemulsion–oil systems. Determination of CFAs has been developed mainly by gas chromatography (GC). As an alternative to GC, liquid chromatography (LC) has better sensitivity and selectivity. However, most CFAs show no useful absorption in ultraviolet–violet (UV–Vis) region, one of the more used detection technique in high-performance liquid chromatography (HPLC). In order to allow the use of UV–Vis detection, the use of pre-column derivatization has been reported to increase sensitivity and selectivity. Therefore, establishment of a simpler and faster on-line method with complete separation is needed for the screening of large numbers of samples. 2,4-Dinitrophenylhydrazine (2,4-DNPH.), benzoil chloride (BC), and phenylhydrazine (PH) were used for derivatization of different FAs by microwaves radiation (MW). After the on-line derivatization, products were separated and quantified by HPLC. Reactor coil was placed inside of microwaves oven at 450 W. Parameters as flow, amount of reagents, irradiation time, and chromatographic conditions were optimized. The continuous analysis using the MW–HPLC–UV system provided high sensitivity and reduced both the amount of reagent used and the analysis times. This proposed method can be used for the routine analysis of FAs contained in water–microemulsion–oil systems, to quantify the total acid fraction in each phase.  相似文献   

18.
Abstract –The products of chlorophyll allomerization in methanol were isolated and analyzed by open column sucrose chromatography, liquid chromatography mass spectrometry (LCMS) and DAD-HPLC (diode-array high-performance liquid chromatography). Four main bands were found with molecular ions of (a) 908, (b) 938, (c) 938 and (d) 938, consistent with the structures (a) 132-hydroxy-chlorophyll a (II), (b) and (c) Mg(II)-31,32-didehydro-151-hydroxy-151-methoxy-rhodochlorin-15 acetic acid δ-lactone 152-methyl 173-phytyl ester and its epimer (III) and (d) Mg(II)-31,32-didehydro-rhodochlorin-15-glyoxylic acid 131,152-dimethyl 173-phytyl ester (IV), evidence enhanced by UV/visible spectroscopy, chromatographic coelutions and chemometrics. Chlorophyll a was degraded both in the dark and light, under O2 and N2. DAD-HPLC of the resultant degradation mixtures were analyzed using the chemometric heuristic-evolving latent projection method for resolution. Ultraviolet/visible spectra of II and III are reproducibly extracted from the mixtures after a short degradation time, whereas III and IV are the dominant compounds after longer degradation times. Changes in relative elution order of IV using open column chromatography and reverse-phase HPLC are established. A possible allomerization pathway is proposed.  相似文献   

19.
我国环境中有机污染物分析方法及痕量富集技术的进展   总被引:1,自引:0,他引:1  
对有机污染物分析在近年进展作了评述。其主要内容涉及试样的预处理技术(如顶空法,吹扫-捕集法,固相萃取,半透膜等技术),各化合物的适用及有效的分析方法或仪器(如GC,HPLC及GC/MS等)以及各种技术及方法的联用技术等(引述文献37篇)。  相似文献   

20.
Gaca J  Wejnerowska G 《Talanta》2006,70(5):1044-1050
The simple, quick and effective methods for the analysis of epichlorohydrin (ECH) in water and sewage samples with the use of gas chromatography have been presented. From among all the methods developed, the procedures for monitoring drinking-water quality and the methods which allow the determination of epichlorohydrin in sewage samples have been selected.

The limits of ECH detection have been determined by direct aqueous injection (DAI) into the chromatographic column and an analysis with the application of a flame ionization detector (FID), a mass spectrometry detector (MS), an electron capture detector (ECD) and atomic emission detection (AED) detectors. The method allows the determination of ECH in water samples at the concentration level of 0.1 mg l−1. Moreover, the developed methods of water samples preparation for chromatographic analysis using the following extraction methods: headspace (HS), stripping with adsorption on solid phase, liquid–liquid extraction (LLE), solid phase extraction (SPE) and solid phase microextraction (SPME) have been evaluated. The limits of ECH detection for each procedure with the application of gas chromatography (GC) combined with various detectors have been determined and their statistical evaluation has been presented. The SPME method allowed us to determine ECH in water samples at the concentration levels of 1.0 ng l−1.

The results of studies on the choice of the selective methods allowing ECH analysis in sewage samples have been demonstrated. The applied SPME method was found to be a quick and effective technique to determine micro trace amounts of ECH in samples containing high amounts of various organic compounds.  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号