首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 35 毫秒
1.
Polycyclic aromatic hydrocarbons (PAHs) are ubiquitous compounds that enter the environment from natural and anthropogenic sources, often used as markers to determine the extent, fate, and potential effects on natural resources after a crude oil accidental release. Gas chromatography-mass spectrometry (GC-MS) after liquid–liquid extraction (LLE+GC-MS) has been extensively used to isolate and quantify both parent and alkylated PAHs. However, it requires labor-intensive extraction and cleanup steps and generates large amounts of toxic solvent waste. Therefore, there is a clear need for greener, faster techniques with enough reproducibility and sensitivity to quantify many PAHs in large numbers of water samples in a short period of time. This study combines online solid-phase extraction followed by liquid chromatography (LC) separation with dopant-assisted atmospheric pressure photoionization (APPI) and tandem MS detection, to provide a one-step protocol that detects PAHs at low nanograms per liter with almost no sample preparation and with a significantly lower consumption of toxic halogenated solvents. Water samples were amended with methanol, fortified with isotopically labeled PAHs, and loaded onto an online SPE column, using a large-volume sample loop with an auxiliary LC pump for sample preconcentration and salt removal. The loaded SPE column was connected to an UPLC pump and analytes were backflushed to a Thermo Hypersil Green PAH analytical column where a 20-min gradient separation was performed at a variable flow rate. Detection was performed by a triple-quadrupole MS equipped with a gas-phase dopant delivery system, using 1.50 mL of chlorobenzene dopant per run. In contrast, LLE+GC-MS typically use 150 mL of organic solvents per sample, and methylene chloride is preferred because of its low boiling point. However, this solvent has a higher environmental persistence than chlorobenzene and is considered a carcinogen. The automated system is capable of performing injection, online SPE, inorganic species removal, LC separation, and MS/MS detection in 28 min. Selective reaction monitoring was used to detect 28 parent PAHs and 15 families of alkylated PAHs. The methodology is comparable to traditional GC-MS and was tested with surface seawater, rainwater runoff, and a wastewater treatment plant effluent. Positive detections above reporting limits are described. The virtual absence of sample preparation could be particularly advantageous for real-time monitoring of discharge events that introduce PAHs into environmental compartments, such as accidental releases of petroleum derivates and other human-related events. This work covers optimization of APPI detection and SPE extraction efficiency, a comparison with LLE+GC-MS in terms of sensitivity and chromatographic resolution, and examples of environmental applications.  相似文献   

2.
In this study, the feasibility of low-pressure gas chromatography (LP-GC) in conjunction with a triple quadrupole mass spectrometer, as a route towards fast pesticide residue analysis, was investigated. A Varian GC-MS system equipped with a mass spectrometer model 1200 was used. LP-GC-MS experiments were performed on a HP-5 10 m x 0.32 mm x 0.25 microm analytical column connected to a 2.5 m x 0.15 mm non-coated restriction precolumn at the inlet end. For comparison purposes conventional GC-MS analysis was performed on a RTX-5 30 m x 0.25 mm x 0.5 microm column. Under the optimized conditions the analysis time was reduced to 13.3 min with the LP-GC approach which corresponds to an almost threefold gain in speed versus the conventional GC (37 min). Despite the poorer separation power of the LP-GC column, the experiments conducted with tomato and onion extracts spiked with 78 pesticides proved that LP-GC-MS is of practical value to perform full scan screening analysis. Moreover, the rate of false negative results was higher in the case of conventional GC-MS while the LP-GC-MS enabled correct identification of pesticides at lower levels since the peaks were improved in both size and shape. Validation experiments were performed on a sample of 12 representative pesticides for comparison of performance characteristics of the LP-GC and GC approaches with mass spectrometer operated in scan, SIM and MS/MS mode. The LP-GC column set-up interfaced to the MS detector was found to be superior to the conventional GC with respect to obtained linearity, accuracy and precision parameters. Also, lower limits of detection in real extracts were achieved using the LP-GC approach. Finally, the LP-GC-MS/MS analysis of tomato samples with incurred pesticide residues demonstrated the applicability of the developed method for analysis of real samples.  相似文献   

3.
Innovative features and technical improvements in modern bench-top quadrupole gas chromatograph-mass spectrometer (GC-MS) have prepared the way for faster and more cost-effective applications while still maintaining sufficient chromatographic resolution, speed of MS data acquisition and reliability of analytical methodology. In this paper, a short wide-bore capillary column with low film thickness (5 m x 0.32 mm i.d., 0.1 microm) was used a pre-fractionating column and only chosen heart-cuts were transferred to the second chromatographic dimension (15 m x 0.25 mm i.d., 0.25 microm) by means of a pressure-adjusted continual flow type switching device for quantification of five common amphetamine-type stimulant drugs. The instrumental setting used, in combination with carefully optimized operational fast GC and MS parameters, markedly decreased the retention times of the targeted analytes, e.g., amphetamine 0.891 min and methamphetamine 1.037 min, and the total chromatographic runtime (1.700 min), as well as reducing the need for continuous cleaning of the MS ion source and increasing column life compared with conventional GC-MS approaches. The performance of the instrumental configuration and analytical method was evaluated in validation experiments and the method was also applied to authentic samples. The method demonstrates the potential of fast GC-MS in combination with a gas-phase microfluidic Deans switch device for analysing of (semi)volatile compounds, such as amphetamine-type stimulant (ATS) drugs. This should be particularly useful in modern laboratories aiming at cost-efficient analysis as well as the optimum use of available laboratory capacity and instrumentation.  相似文献   

4.
A new type of low thermal mass (LTM) fast gas chromatograph (GC) was designed and operated in combination with gas chromatography mass spectrometry (GC-MS) with supersonic molecular beams (SMB), including GC-MS-MS with SMB, thereby providing a novel combination with unique capabilities. The LTM fast GC is based on a short capillary column inserted inside a stainless steel tube that is resistively heated. It is located and mounted outside the standard GC oven on its available top detector port, while the capillary column is connected as usual to the standard GC injector and supersonic molecular beam interface transfer line. This new type of fast GC-MS with SMB enables less than 1 min full range temperature programming and cooling down analysis cycle time. The operation of the fast GC-MS with SMB was explored and 1 min full analysis cycle time of a mixture of 16 hydrocarbons in the C(10)H(22) up to C(44)H(90) range was achieved. The use of 35 mL/min high column flow rate enabled the elution of C(44)H(90) in less than 45 s while the SMB interface enabled splitless acceptance of this high flow rate and the provision of dominant molecular ions. A novel compound 9-benzylazidanthracene was analyzed for its purity and a synthetic chemistry process was monitored for the optimization of the chemical reaction yield. Biodiesel was analyzed in jet fuel (by both GC-MS and GC-MS-MS) in under 1 min as 5 ppm fatty acid methyl esters. Authentic iprodion and cypermethrin pesticides were analyzed in grapes extract in both full scan mode and fast GC-MS-MS mode in under 1 min cycle time and explosive mixture including TATP, TNT and RDX was analyzed in under 1 min combined with exhibiting dominant molecular ion for TATP. Fast GC-MS with SMB is based on trading GC separation for speed of analysis while enhancing the separation power of the MS via the enhancement of the molecular ion in the electron ionization of cold molecules in the SMB. This paper further discusses several features of fast GC and fast GC-MS and the various trade-offs involved in having powerful and practical fast GC-MS.  相似文献   

5.
Gas chromatography-mass spectrometry (GC-MS) suffers from a major limitation in that an expanding number of thermally labile or low volatility compounds of interest are not amenable for analysis. We found that the elution temperatures of compounds from GC can be significantly lowered by reducing the column length, increasing the carrier gas flow rate, reducing the capillary column film thickness and lowering the temperature programming rate. Pyrene is eluted at 287 degrees C in standard GC-MS with a 30 m x 0.25 mm I.D. column with 1-microm DB5ms film and 1-ml/min He column flow rate. In contrast, pyrene is eluted at 79 degrees C in our "Supersonic GC-MS" system using a 1 m x 0.25 mm I.D. column with 0.1-microm DB5ms film and 100-ml/min He column flow rate. A simple model has been invoked to explain the significantly (up to 208 degrees C) lower elution temperatures observed. According to this model, every halving of the temperature programming rate, or number of separation plates (either through increased flow rate or due to reduced column length), results in approximately 20 degrees C lower elution temperature. These considerably lower elution temperatures enable the analysis of an extended range of thermally labile and low volatility compounds, that otherwise could not be analyzed by standard GC-MS. We demonstrate the analysis of large polycyclic aromatic hydrocarbons (PAHs) such as decacyclene with ten fused rings, well above the current GC limit of PAHs with six rings. Even a metalloporphirin such as magnesiumoctaethylporphin was easily analyzed with elution temperatures below 300 degrees C. Furthermore, a range of thermally labile compounds were analyzed including carbamates such as methomyl, aldicarb, aldicarbsulfone and oxamyl, explosives such as pentaerythritol tetranitrate, Tetryl and HMX, and drugs such as reserpine (608 a.m.u.). Supersonic GC-MS was used, based on the coupling of a supersonic molecular beam (SMB) inlet and ion sources with a bench-top Agilent 6890 GC plus 5972 MSD. The Supersonic GC-MS provides enhanced molecular ion without any ion source related peak tailing. Thus, the lower GC separation power involved in the analysis of thermally labile and low volatility compounds is compensated by increased separation power of the MS gained from the enhanced molecular ion. Several implications of these findings are discussed, including our conclusion that slower chromatography leads to better analysis of thermally labile compounds.  相似文献   

6.
The concept of low pressure (LP) vacuum outlet gas chromatography (GC) was introduced more than 50 years ago, but it was not until the 2000s that its theoretical applicability to fast analysis of GC-amenable chemicals was realized. In practice, LPGC is implemented by placing the outlet of a short, wide (typically 10–15 m, 0.53 mm inner diameter) analytical column under vacuum conditions, which speeds the separation by reducing viscosity of the carrier gas, thereby leading to a higher optimal flow rate for the most separation efficiency. To keep the inlet at normal operating pressures, the analytical column is commonly coupled to a short, narrow uncoated restriction capillary that also acts as a guard column. The faster separations in LPGC usually result in worse separation efficiency relative to conventional GC, but selective detection usually overcomes this drawback. Mass spectrometry (MS) provides highly selective and sensitive universal detection, and nearly all GC-MS instruments provide vacuum outlet conditions for implementation of LPGC-MS(/MS) without need for adaptations. In addition to higher sample throughput, LPGC provides other benefits, including lower detection limits, less chance of analyte degradation, reduced peak tailing, increased sample loadability, and more ruggedness without overly narrow peaks that would necessitate excessively fast data acquisition rates. This critical review summarizes recent developments in the application of LPGC with MS and other detectors in the analysis of pesticides, environmental contaminants, explosives, phytosterols, and other semi-volatile compounds.  相似文献   

7.
This study describes the determination of polycyclic aromatic hydrocarbons (PAHs) in water using high-performance liquid chromatography (HPLC) coupled with fluorescence detection (FLD). Because individual PAHs are generally present in water only at trace levels, a sensitive and accurate determination technique is essential. The separation and detection of five PAHs were run completely within 25 min by the HPLC/FLD system with an analytical C18 column, a fluorescence detection, and acetonitrile-water gradient elution. Calibration graphs were linear with very good correlation coefficients (r > 0.9998), and the detection limits were in the range of 2-6 ng/l for five PAHs. Solid phase microextraction (SPME) was performed for sample pretreatment prior to HPLC-FLD determination, and the governing parameters were investigated. Compared to conventional methods, SPME has high recovery, saves considerable time, and reduces solvents waste. The extraction efficiencies of five PAHs were above 88% and the extraction times were 35 min in one pretreatment procedure. One particular discovery is that 1.5 M sodium monochloroactate (ClCH2COONa) can improve the extraction yield of PAH compounds more than other inorganic salts. The SPME-HPLC-FLD technique provides a relatively simple, convenient, practical procedure, which was here successfully applied to determine five PAHs in water from authentic water samples.  相似文献   

8.
Yang C  Piao X  Qiu J  Wang X  Ren C  Li D 《Journal of chromatography. A》2011,1218(12):1549-1555
Sample pretreatment before chromatographic analysis is the most time consuming and error prone part of analytical procedures, yet it is a key factor in the final success of the analysis. A quantitative and fast liquid phase microextraction technique termed as gas purge microsyringe extraction (GP-MSE) has been developed for simultaneous direct gas chromatography-mass spectrometry (GC-MS) analysis of volatile and semivolatile chemicals without cleanup process. Use of a gas flowing system, temperature control and a conventional microsyringe greatly increased the surface area of the liquid phase micro solvent, and led to quantitative recoveries of both volatile and semivolatile chemicals within short extraction time of only 2 min. Recoveries of polycyclic aromatic hydrocarbons (PAHs), organochlorine pesticides (OCPs) and alkylphenols (APs) determined were 85-107%, and reproducibility was between 2.8% and 8.5%. In particular, the technique shows high sensitivity for semivolatile chemicals which is difficult to achieve in other sample pretreatment techniques such as headspace-liquid phase microextraction. The variables affecting extraction efficiency such as gas flow rate, extraction time, extracting solvent type, temperature of sample and extracting solvent were investigated. Finally, the technique was evaluated to determine PAHs, APs and OCPs from plant and soil samples. The experimental results demonstrated that the technique is economic, sensitive to both volatile and semivolatile chemicals, is fast, simple to operate, and allows quantitative extraction. On-site monitoring of volatile and semivolatile chemicals is now possible using this technique due to the simplification and speed of sample treatment.  相似文献   

9.
The feasibility of using a monolithic column as the analytical column in conjunction with high-flow direct-injection liquid chromatography/tandem mass spectrometry (LC/MS/MS) to increase productivity for quantitative bioanalysis has been investigated using plasma samples containing a drug and its epimer metabolite. Since the chosen drug and its epimer metabolite have the same selected reaction monitoring (SRM) transitions, chromatographic baseline separation of these two compounds was required. The results obtained from this monolithic column system were directly compared with the results obtained from a previously validated assay using a conventional C18 column as the analytical column. Both systems have the same sample preparation, mobile phases and MS conditions. The eluting flow rate for the monolithic column system was 3.2 mL/min (with 4:1 splitting) and for the C18 column system was 1.2 mL/min (with 3:1 splitting). The monolithic column system had a run time of 5 min and the conventional C18 column system had a run time of 10 min. The methods on the two systems were found to be equivalent in terms of accuracy, precision, sensitivity and chromatographic separation. Without sacrificing the chromatographic separation, sensitivity, accuracy and precision of the method, the reduced run time of the monolithic column method increased the sample throughput by a factor of two.  相似文献   

10.
A fast method of analysis for 20 representative pesticides was developed using low-pressure gas chromatography-mass spectrometry (LP-GC-MS). No special techniques for injection or detection with a common quadrupole GC-MS instrument were required to use this approach. The LP-GC-MS approach used an analytical column of 10 m x 0.53 mm I.D., 1 microm film thickness coupled with a 3 m x 0.15 mm I.D. restriction capillary at the inlet end. Thus, the conditions at the injector were similar to conventional GC methods, but sub-atmospheric pressure conditions occurred throughout the analytical column (MS provided the vacuum source). Optimal LP-GC-MS conditions were determined which achieved the fastest separation with the highest signal/noise ratio in MS detection (selected ion monitoring mode). Due to faster flow-rate, thicker film, and low pressure in the analytical column, this distinctive approach provided several benefits in the analysis of the representative pesticides versus a conventional GC-MS method, which included: (i) threefold gain in the speed of chromatographic analysis; (ii) substantially increased injection volume capacity in toluene; (iii) heightened peaks with 2 s peak widths for normal MS operation; (iv) reduced thermal degradation of thermally labile analytes, such as carbamates; and (v) due to larger sample loadability lower detection limits for compounds not limited by matrix interferences. The optimized LP-GC-MS conditions were evaluated in ruggedness testing experiments involving repetitive analyses of the 20 diverse pesticides fortified in a representative food extract (carrot), and the results were compared with the conventional GC-MS approach. The matrix interferences for the quantitation ions were worse for a few pesticides (acephate, methiocarb, dimethoate, and thiabendazole) in LP-GC-MS, but similar or better results were achieved for the 16 other analytes, and sample throughput was more than doubled with the approach.  相似文献   

11.
A rapid multiresidue method for the analysis of 72 pesticides has been developed using a single injection with low-pressure gas chromatography/tandem mass spectrometry (LP-GC/MS/MS). The LP-GC/MS/MS method used a short capillary column of 10 m x 0.53 mm i.d. x 0.25 microm film thickness coupled with a 0.6 m x 0.10 mm i.d. restriction at the inlet end. Optimal LP-GC conditions were determined which achieved the fastest separation in MS/MS detection mode. Also MS/MS conditions were optimized in order to increase sensitivity and selectivity. The analytical parameters of the LP-GC/MS/MS method were compared with those obtained by GC/MS/MS using a conventional capillary column (30 m x 0.25 mm i.d. x 0.25 microm film thickness). Better precision and sensitivity values were obtained with the LP-GC/MS/MS approach. The limits of detection (LOD) of the compounds ranged from 0.1 to 14.1 microg L(-1) for LP-GC/MS/MS, lower than those obtained for conventional GC/MS/MS that ranged from 0.1 to 17.5 microg L(-1). The peak widths obtained with the short column in LP-GC are similar to those obtained using conventional capillary GC columns, and the peaks can be successfully identified by MS/MS detection with the conventional scan speed of ion-trap instruments. In addition, the analysis time was significantly reduced with LP-GC/MS/MS (32 min) versus GC/MS/MS (72 min), allowing the number of samples analyzed per day in a routine laboratory to be doubled.  相似文献   

12.
SnifProbe is based on the use of 15 mm short pieces of standard 0.53 mm I.D. capillary or porous layer open tubular columns for sampling airborne, headspace, aroma or air pollution samples. A miniaturized frit-bottomed packed vial named MicroSPE was also prepared which served for the sampling of solvent vapors and gases as well as liquid water. The short (15 mm) trapping column is inserted into the SnifProbe easy-insertion-port and the SnifProbe is located or aimed at the sample environment. A miniature pump is operated for pumping 10-60 ml/min of the air sample through the short piece of column to collect the sample. After a few seconds up to a few minutes of pumping, the short column is removed from the SnifProbe with tweezers (or gloved hands) and placed inside a glass vial of a direct sample introduction device (ChromatoProbe) having a 0.5 mm hole at its bottom. The ChromatoProbe sample holder with its glass vial and sample in the short column are introduced into the GC injector as usual. The sample is then quickly and efficiently desorbed from the short sample column and is transferred into the analytical column for conventional GC and/or GC-MS analysis. We have explored the various characteristics of SnifProbe and demonstrated its applicability and effectiveness in many applications. These applications include: the analysis of benzene, toluene and o-xylene in air, SO2 in air, perfume aroma on hand, beer headspace, wine aroma, coffee aroma, cigarette smoke, trace chemical warfare agent simulants, explosives vapors, ethanol in human breath and odorants in domestic cooking gas. SnifProbe can be operated in the field or at a chemical process. The sample columns can be plugged and stored in a small union storage device, placed in a small plastic bag, marked and brought to the laboratory for analysis with the full power of GC and/or GC-MS. Accordingly, we feel that the major and most significant feature of SnifProbe is that it brings the field and process to the laboratory. Thus, SnifProbe can extend the "arm" of the GC and GC-MS laboratory and enable high-quality field and process analysis.  相似文献   

13.
A new method based on separation with gas chromatography and detection with a quartz crystal microbalance was used for quantification of nitrobenzene, 2-, 3- and 4-nitrotoluene in landfill gas. The analytical error, the analysis time and general analytical performance were identical for gas chromatography-mass spectrometry (GC-MS) and gas chromatography-quartz crystal microbalance (GC-QCM). GC-QCM constitutes a very inexpensive alternative to GC-MS for monitoring nitroaromatic compounds in landfill gas.  相似文献   

14.
A major challenge in metabolomics analysis is the accurate quantification of metabolites in the presence of (extremely) high abundant metabolites. Quantification of metabolites at low concentrations can be complicated by co-elution and/or peak distortion when these metabolites elute close to high abundant metabolites. To increase the separation efficiency a comprehensive two-dimensional gas chromatographic-mass spectrometric method (GC x GC-MS) was set up, in which a polar first dimension column and an apolar second dimension column were used to maximize the peak capacity. The feasibility of using wider bore, thicker film columns in the second dimension to improve the mass loadability and inertness of the analytical system was investigated. Several column combinations with varying second dimension column dimensions were compared with a setup with a narrow bore column (0.1mm I.D.) in the second dimension. With a wider bore column (0.32 mm I.D.) in the second dimension the mass loadability was improved 10-fold, and the more inert column surface of the thicker film second dimension column resulted in a more accurate (automated) quantification and improved linearity in the presence of high concentrations of matrix compounds or metabolites. These benefits amply compensated the observed decrease in peak capacity of 40% compared to the narrow bore (0.1mm I.D.) thin film second dimension column. Compared to GC-MS and conventional GC x GC-MS, better performance for quantification of metabolites for typical metabolomics samples was achieved.  相似文献   

15.
建立了玩具中10种有机物迁移量的固相萃取/气相色谱-质谱测定方法。样品在25 mL去离子水中迁移60min,得到的迁移液流经Chromabond Easy固相萃取柱,用乙酸乙酯洗脱5次,每次1 mL。洗脱液过滤膜后通过60m DB-624色谱柱分离,质谱进行检测,外标法定量。方法对于不同有机物的定量限(LOQ)在0.0...  相似文献   

16.
This paper presents the optimisation of a programmed temperature vaporization solvent vent (PTV-SV) injection gas chromatographic mass spectrometric (GC-MS) method for the analysis of the 15 + 1 EU-priority PAHs in food extracts. Three operation parameters (vent time, vent flow and vent pressure) were optimised by applying a D-optimal experimental design. Among these variables, vent time showed the highest effect on the analytical response (signal intensity) of the target PAHs.The 15 + 1 EU-priority PAHs were analysed in solvent solutions and in extracts of fortified sausage. In addition, blank lamb meat extracts were prepared and spiked with the target PAHs prior to GC-MS analysis. The performance of the optimised PTV-SV injection GC-MS method was scrutinised for linearity, precision, matrix effects and robustness. All parameters were found satisfactorily. Compared to PTV injection in splitless mode, the PTV-SV injection method provided an enhancement of sensitivity for all target PAHs. Especially significant was the improvement of the S/N ratios of the compounds with the highest molecular mass.  相似文献   

17.
快速气相色谱法分析石油饱和烃   总被引:6,自引:0,他引:6  
武杰  曹磊  李英明  端裕树 《色谱》2004,22(5):479-481
提出了一种快速分析原油和岩石抽提物中饱和烃组分的毛细管气相色谱(GC)方法。由于在该方法中采用了细内径毛细管柱,故饱和烃的GC分析周期由原来的80~90 min缩短至15 min,分析速度加快约5倍,大大提高了工作效率和仪器通量,使石油饱和烃得到了很好的分离分析。该方法符合中华人民共和国石油天然气行业标准SY/T5120-1997的要求。20万理论塔板数的细径柱的应用,可供石油中异构烷烃,尤其是甾烷、萜烷类的气相色谱/质谱(GC/MS)快速分析方法及芳烃的GC快速分析方法借鉴。  相似文献   

18.
The potential of high-speed analyses by rapid resolution liquid chromatography (RRLC) and RRLC/MS on 1.8-microm porous particles packed into short columns operated at high flow-rate was investigated and compared with the performance of 5-microm porous particles packed into conventional columns. Using similar chemistries, the ease of conversion from conventional HPLC to an RRLC method was demonstrated. In order to display the practicality of RRLC separations, the analysis of pesticides in crops and catechins in Japanese green tea was selected. Using the Japanese Food Hygiene Law method, which employs a conventional 5-microm RP column (250 mm x 4.6 mm) for quantification of pesticides in crops, the analysis time was 25 min under isocratic conditions. Using the RRLC method on the short (50 mm x 4.6 mm) column packed with 1.8-microm porous particles, the same separation could be performed in 0.8 min with the RRLC/MS method without a loss in resolution. At the highest flow rate, compared to the conventional method, the time could be reduced by a factor of 31. In gradient elution, the fastest separation of catechins in Japanese green tea was achieved by RRLC on 50-mm x 4.6-mm id or 50-mm x 2.1-mm id RRLC columns packed with 1.8-microm particles. The analysis time at 5 mL/min was less than 1 min. Compared to the conventional HPLC method on a 150-mm column packed with 5-microm particles, time was reduced by a factor of 15. The effect of other experimental parameters such as the column temperature, acquisition rate of the detector and the influence of cell volume on chromatographic performance was also investigated. After the optimization, the analysis precision under the fastest RRLC conditions was examined. RSDs of retention time and peak area were 0.2% and 0.47%, respectively.  相似文献   

19.
Coupled liquid chromatography – gas chromatography – mass spectrometry (LC-GC-MS) has been applied for on-line clean up, separation, and identification of chlorinated polycyclic aromatic hydrocarbons (CI-PAHs). A loop-type interface was used to couple the liquid chromatograph on-line with the GC-MS, and concurrent solvent evaporation was used for sample transfer. A back-flush technique was used in conjunction with a two-dimensional column system for isolation of CI-PAHs and polycyclic aromatic hydrocarbons (PAHs). This fraction was transferred on-line to the GC and separated on a capillary column. Selective and sensitive detection of CI-PAHs in the GC eluate was obtained by negative ion chemical ionization (NICI) mass spectrometry and selected ion monitoring (SIM). The combined on-line system for isolation, separation, and identification showed high precision and accuracy, and demonstrated a linear response from 1 to 1000 pg for chlorinated PAHs. The estimated detection limit was 250 fg for 1-chloropyrene and 1,6-dichloropyrene. The technique was demonstrated by analysis of urban air samples. The low detection limit made it possible to use the technique for analysis of personally carried monitoring equipment for measurement of exposure to CI-PAHs in the work environment.  相似文献   

20.
We report an offline multi-dimensional high performance liquid chromatography (HPLC) technique for the group separation and analysis of PAHs in a heavy gas oil fraction (boiling range 287-481 degrees C). Waxes present in the heavy gas oil fraction were precipitated using cold acetone at -20 degrees C. Recovery studies showed that the extract contained 93% (+/-1%; n=3) of the PAHs that were originally present while the wax residue contained only 6% (+/-0.5%; n=3). PAHs present in the extract were fractionated, based on number of rings, into five fractions using a semi-preparative silica column (normal-phase HPLC). These fractions were analyzed using reverse-phase HPLC (RP-HPLC) coupled to a diode array detector (DAD). The method separated alkyl and un-substituted PAHs on two reverse-phase columns in series using an acetonitrile/water mobile phase. UV spectra of the chromatographic peaks were used to differentiate among PAH groups. Further characterization of PAHs within a given group to determine the substituent alkyl carbon number used retention time matching with a suite of alkyl-PAH standards. Naphthalene, dibenzothiophene, phenanthrene and fluorene and their C1-C4 alkyl isomers were quantified. The concentrations of these compounds obtained using the current method were compared with that of a GC-MS analysis obtained from an independent oil chemistry laboratory.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号