首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 611 毫秒
1.
The aim of this study was the optimization of headspace SPME conditions for trapping diterpenes present in frankincense (olibanum). Diterpenes like cembrenes or incensole and its derivatives are characteristic of olibanum. So in order to detect by SPME the occurrence of olibanum in archeological objects, it appears essential to have the best extraction conditions for these diterpenes that will be in very small quantities. Both sampling time and extraction temperature were studied and five fiber coatings were tested: polydimethylsiloxane (PDMS), polydimethylsiloxane/divinylbenzene (PDMS/DVB), carboxen/polydimethylsiloxane (CAR/PDMS), divinylbenzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS) and carbowax/divinylbenzene (CW/DVB). The PDMS/DVB fiber was found to be the most efficient for trapping olibanum characteristic diterpenes, with a sampling time of 1 h and a sampling temperature of 80 degrees C.  相似文献   

2.
Fiber introduction mass spectrometry (FIMS)-a direct coupling of SPME and MS-using selective ion monitoring (SIM) was used to detect and quantify dimethylphthalate (DMP), diethylphthalate (DEP) and dipropylphthalate (DPP) in mineral water. In FIMS, a chromatographic silicone septum is the only barrier between ambient and the high-vacuum mass spectrometer, permitting direct introduction of the SPME fiber into the ionization region of the equipment. After their thermal desorption and ionization and dissociation, the extracted phthalates are detected and quantitated by MS. Three types of SPME fibers were screened for best analyte sorption/desorption behaviors: 100 microm polydimethylsiloxane (PDMS), 65 microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) and 65 microm Carbowax/divinylbenzene (CW/DVB). The PDMS/DVB and CW/DVB fibers were then evaluated for precision, and quantitative figures of merit were assessed for extractions using the PDMS/DVB fiber, which displayed the best overall performance. FIMS with the PDMS/DVB fiber allows simple extraction and MS detection and quantitation of DMP in water with good linearity and precision, and at concentrations as low as 3.6 microg L(-1). The LD and LQ of FIMS are below the maximum phthalate concentration allowed by the USEPA for drinking water (6 microg L(-1)).  相似文献   

3.
Extraction of dry cured ham volatile compounds by solid-phase microextraction (SPME) was optimized. Different fiber coatings (carboxen/polydimethylsiloxane (CAR/PDMS), divinylbenzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS), polydimethylsiloxane (PDMS), polydimethylsiloxane/divinylbenzene (PDMS/DVB)), times of extraction (15, 30, 60 min) and sample preparation (ground samples and homogenates with NaCl saturated solution) were assayed. CAR/PDMS and DVB/CAR/PDMS fiber coatings extracted more than 100 volatile compounds and showed the highest area counts for most volatile compounds. CAR/PDMS coating extracted better those compounds whose Kovats index (KI) was lower than 980 (on average) and DVB/CAR/PDMS those with higher KI. Fifteen minutes of extraction provided a volatile compound profile with lower area counts for most compounds and qualitatively different to that obtained with 30 and 60 min of extraction. Homogenates gave a different profile compared to ground samples, with lower total counts for most compounds but higher proportion of aldehydes, and presence of several compounds not found in ground samples.  相似文献   

4.
The use of solid-phase microextraction (SPME) coupled to ion mobility spectrometry (IMS) to detect precursor and degradation products of chemical warfare agents (CWAs) as soil contaminants was investigated. The development and characterization of a system to interface a thermal desorption solid-phase microextraction inlet with a hand held ion mobility spectrometer was demonstrated. The analytes used in this study were diisopropyl methylphosphonate (DIMP), diethyl methylphosphonate (DEMP), and dimethyl methylphosphonate (DMMP). Two SPME fibers with different stationary phases, 100 μm polydimethylsiloxane (PDMS) and 65 μm polydimethylsiloxane divinylbenzene (PDMS/DVB), were evaluated in this study to determine the optimal fiber and extraction conditions. Better results were obtained with the PDMS fiber. SPME-IMS offered good repeatability and detection of the precursor and degradation products in spiked soil at concentrations as low as 10 μg/g. Sample analysis time was less than 30 min for all the precursor and degradation products.  相似文献   

5.
The aroma profile of cocoa products was investigated by headspace solid-phase micro-extraction (HS-SPME) combined with gas chromatography–mass spectrometry (GC–MS). SPME fibers coated with 100 μm polydimethylsiloxane coating (PDMS), 65 μm polydimethylsiloxane/divinylbenzene coating (PDMS-DVB), 75 μm carboxen/polydimethylsiloxane coating (CAR-PDMS) and 50/30 μm divinylbenzene/carboxen on polydimethylsiloxane on a StableFlex fiber (DVB/CAR-PDMS) were evaluated. Several extraction times and temperature conditions were also tested to achieve optimum recovery. Suspensions of the samples in distilled water or in brine (25% NaCl in distilled water) were investigated to examine their effect on the composition of the headspace. The SPME fiber coated with 50/30 μm DVB/CAR-PDMS afforded the highest extraction efficiency, particularly when the samples were extracted at 60 °C for 15 min under dry conditions with toluene as an internal standard. Forty-five compounds were extracted and tentatively identified, most of which have previously been reported as odor-active compounds. The method developed allows sensitive and representative analysis of cocoa products with high reproducibility. Further research is ongoing to study chocolate making processes using this method for the quantitative analysis of volatile compounds contributing to the flavor/odor profile.  相似文献   

6.
The performance of three fibres for the headspace solid-phase microextraction (SPME) of di-2-ethylhexyl adipate (DEHA) and eight phthalates in water was investigated systematically under different extraction conditions. Good responses on the 65 microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) SPME fibre were observed for DEHA and all phthalates. The polydimethylsiloxane (PDMS) SPME fibre had very poor responses for the lighter and slightly polar phthalates, dimethyl phthalate (DMP) and diethyl phthalate (DEP), while the divinylbenzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS) SPME fibre had very poor responses for the heavier and non-polar adipate and phthalates. The salt (NaCl) was found to increase the partitioning of DMP, DEP, diisobutyl phthalate (DiBP), di-n-butyl phthalate, and benzyl butyl phthalate (BBP) from water into the headspace, while partitioning of heavier adipate and phthalates from water into headspace was suppressed when the concentration of NaCl was above 10%. The automated headspace SPME methods were developed and validated under two different salting conditions (30% NaCl for DMP, DEP and BBP, and 10% for DEHA, DiBP, DBP, di-n-hexyl phthalate (DHP), di-2-ethylhexyl phthalate (DEHP), and di-n-octyl phthalate (DOP)). Linearity with R(2) values better than 0.9949 was observed for DEHA and eight phthalates over the range from 0.1 to 20 microg L(-1). Method detection limits ranged from 0.003 microg L(-1) for DOP to 0.085 microg L(-1) for BBP. Good repeatability was observed for DEHA and most phthalates with relative standard deviation (RSD) values less than 10%. The methods were used to analyse bottled water samples for DEHA and eight phthalates. DMP, DHP, BBP, DEHA and DOP were not detected in any samples. Concentrations of the other phthalates were low (around sub-ppb) except for DBP in the water from a polycarbonate bottle at 1.72 microg L(-1).  相似文献   

7.
An experimental design optimization is reported of an analytical procedure used in the simultaneous determination of seven non-steroidal anti-inflammatory drugs (NSAIDs) in bovine milk by gas chromatography with mass spectrometry detection (GC-MS). This analytical procedure involves a solid-phase microextraction (SPME) step and an aqueous derivatization procedure of the NSAIDs to ethyl esters in bovine milk. The following NSAIDs are studied: ibuprofen (IBP), naproxen (NPX), ketoprofen (KPF), diclofenac (DCF), flufenamic acid (FLF), tolfenamic acid (TLF) and meclofenamic acid (MCL). Three kinds of SPME fibers - polyacrylate (PA), polydimethylsiloxane/divinylbenzene (PDMS/DVB) and polydimethylsiloxane (PDMS) - are compared to identify the most suitable one for the extraction process, on the basis of two steps: to determine the equilibrium time of each fiber and to select the fiber that provides the best figures-of-merit values calculated with three-way PARAFAC-based calibration models at the equilibrium time. The best results were obtained with the PDMS fiber. Subsequently, 8 experimental factors (related to the derivatization reaction and the SPME) were optimized by means of a D-optimal design that involves only 14 rather than 512 experiments in the complete factorial design. The responses used in the design are the sample mode loadings of the PARAFAC decomposition which are related to the quantity of each NSAID that is extracted in the experiment. Owing to the fact that each analyte is unequivocally identified in the PARAFAC decomposition, a calibration model is not needed for each experimental condition. The procedure fulfils the performance requirements for a confirmatory method established in European Commission Decision 2002/657/EC.  相似文献   

8.
In order to develop a valuable method for accurate screening of biogenic emissions from undisturbed living plants or for plant-insect interactions, solid-phase microextraction (SPME) has been combined with dynamic branch enclosure cuvettes and enantioselective GC/MS. The study was conducted at Hyyti?l? forest station, Finland within a boreal coniferous forest dominated by Scots pine (Pinus sylvestris). The SPME method was optimized for monoterpenes by testing three fibre coatings: polydimethylsiloxane (PDMS), polydimethylsiloxane/divinylbenzene (PDMS/DVB) and carbowax/divinylbenzene (CW/DVB) and determining the optimum exposure time. The PDMS/DVB fibre was found to be most suitable and was used to characterize emissions of P. sylvestris enclosed in dynamic branch enclosure cuvettes by exposure for 1 min followed by desorption and separation on a beta-cyclodextrin column installed in the GC/MS oven. Dynamic cuvette measurements have been compared to static headspace SPME samples of the emission of detached needles from the same tree species and a portable dynamic air sampler (PDAS)-SPME for sampling the ambient air around the same trees. The method developed has allowed an accurate characterization of the gaseous emission of P. sylvestris and the identification of 17 isoprenoids comprising chiral and achiral monoterpenes. Two chemotypes of Scots pine can be differentiated through their emission of (+)-delta-3-carene. While SPME-dynamic cuvette, portable dynamic sampler and absorbent results agreed well, significant differences in enantiomeric ratios were observed in natural emissions and those of damaged leaves. Therefore, in enantioselective studies of plant-insect and/or plant-plant interactions, the two enantiomers of a given monoterpene should be treated as two separate substances.  相似文献   

9.
《Analytical letters》2012,45(4):645-660
Abstract

A novel reproducible solid‐phase microextraction (SPME) coating was prepared on the surface of silanized silica fibers by molecularly imprinted polymerization using prometryn as template molecule. The structure and extraction performance of molecularly imprinted polymer (MIP) coating was studied with the scanning electron microscope and high performance liquid chromatography (HPLC). Specific selectivity was found with the prometryn MIP‐coated fiber to prometry and its structural analogues such as atrazine, simetryn, terbutylazin, ametryn, propazine and terbutryn. In contrast, these triazines could not be selectively extracted by the non‐imprinted polymer fiber or commercial polydimethylsiloxane (PDMS), polydimethylsiloxane/divinylbenzene (PDMS/DVB), polyacrylate (PA) fibers.  相似文献   

10.
Solid-phase microextraction (SPME) coupled to LC for the analysis of five diphenylether herbicides (aclonifen, bifenox, fluoroglycofen-ethyl, oxyfluorfen, and lactofen) is described. Various parameters of extraction of analytes onto the fiber (such as type of fiber, extraction time and temperature, pH, impact of salt and organic solute) and desorption from the fiber in the desorption chamber prior to separation (such as type and composition of desorption solvent, desorption mode, soaking time, and flush-out time) were studied and optimized. Four commercially available SPME fibers were studied. PDMS/divinylbenzene (PDMS/DVB, 60 microm) and carbowax/ templated resin (CW/TPR, 50 microm) fibers were selected due to better extraction efficiencies. Repeatability (RSD, < 7%), correlation coefficient (> 0.994), and detection limit (0.33-1.74 and 0.22-1.94 ng/mL, respectively, for PDMS/DVB and CW/TPR) were investigated. Relative recovery (81-104% for PDMS/DVB and 83-100% for CW/TPR fiber) values have also been calculated. The developed method was successfully applied to the analysis of river water and water collected from a vegetable garden.  相似文献   

11.
A method involving headspace-solid phase micro-extraction (HS-SPME), gas chromatography with flame ionization detection (GC-FID) and gas chromatography with mass spectrometry (GC-MS) was developed and optimized to investigate the volatile composition of Capsicum chili peppers. Five SPME fibers were tested for extraction: carboxen/polydimethylsiloxane (CAR/PDMS-75μm), polydimethylsiloxane (PDMS-100μm), divinylbenzene/polydimethylsiloxane (DVB/PDMS-65μm), carbowax/divinylbenzene (CW/DVB-70μm), and divinylbenzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS-50/30μm), the last of which was shown to be the most efficient fiber to trap the volatile compounds. Optimization of the extraction conditions was carried out using multivariate strategies such as factorial design and response surface methodology. Eighty three compounds were identified by GC-MS when using the optimized extraction conditions, the majority of which were esters.  相似文献   

12.
Huang SD  Huang HI  Sung YH 《Talanta》2004,64(4):887-893
Solid-phase microextraction (SPME) coupled with high-performance liquid chromatography (HPLC) for the determination of triazine is described. Carbowax/templated resin (CW/TPR, 50 μm), polydimethylsiloxane/divinylbenzene (PDMS/DVB, 60 μm), polydimethylsiloxane (PDMS, 100 μm), and polyacrylate (PA, 85 μm) fibers were evaluated for extraction of the triazines. CW/TPR and PDMS/DVB fibers were selected for further study. Several parameters of the extraction and desorption procedure were studied and optimized (such as types of fibers, desorption mode, desorption time, compositions of solvent for desorption, soaking periods and the flow rate during desorption period, extraction time, temperature, pH, and ionic strength of samples). Both CW/TPR and PDMS/DVB fibers are acceptable; a simple calibration-curve method based on simple aqueous standards can be used. The linearity of this method for analyzing standard solution has been investigated over the range 5-1000 ng mL−1 for both PDMS/DVB and CW/TPR fibers. All the correlation coefficients in the range 5-1000 ng mL−1 were better than 0.995 except Simazine and Atratone by CW/TPR fiber. The R.S.D.s range from 4.4% to 8.8 % (PDMS/DVB fiber) and from 2.4% to 7.2% (CW/TPR fiber). Method-detection limits (MDL) are in the range 1.2-2.6 and 2.8-3.4 ng mL−1 for the two fibers. These methods were applied to the determination of trazines in environmental water samples (lake water).  相似文献   

13.
Grumixama (Eugenia brasiliensis Lam.) is a native fruit of the Brazilian Atlantic Forest, belonging to the Myrtaceae family, which designatesthe most significant number of species with food potential. It stands out due to its phytochemical characteristics because of the presence of polyphenols and volatile organic compounds. Volatile compounds are substances released by foods that give off an aroma and influence flavor. Solid-phase microextraction is a technique that allows for low-cost, fast, and solvent-free extraction, has an affinity for numerous analytes, and is easily coupled to gas chromatography. The objectives of this work were to evaluate the efficiency of different fibers of SPME (solid-phase microextraction) in the extraction of volatile organic compounds from grumixama pulp; optimize a method for extraction time, temperature, and sample weight; and to determine the characteristic volatile profile of this fruit. For the extraction of volatile compounds, three fibers of different polarities were used: polar polyacrylate (PA) fibers, divinylbenzene/carboxyne/polydimethylsiloxane (DVB/CAR/PDMS) semipolar fibers, and polydimethylsiloxane/divinylbenzene (PDMS/DVB). Fourteen volatile organic compounds (VOCs) were identified by DVB/CAR/PDMS, six by PA, and seven by PDMS/DVB through solid-phase microextraction in the headspace mode (SPME-HS). Considering the total number of compounds identified, regardless of the fiber used, and the optimization of the method, Eugenia brasiliensis presented sesquiterpene fractions (85.7%, 83.3%, and 85.7% of total VOCs) higher than the monoterpene fractions (14.3%, 16.7%, and 14.3%) for DVB/CAR/PDMS, PA, and PDMS/DVB, respectively in its composition. In addition, it was possible to verify that the fiber DVB/CAR/PDMS presented a better efficiency due to the larger chromatographic area observed when the grumixama pulp was subjected to conditions of 75 °C, 2.0 g, and an adsorption time of 20 min.  相似文献   

14.
Solid-phase microextraction (SPME) is a rapid and simple analytical technique which uses coated fused-silica fibers to extract analytes from aqueous samples. This study develops a method of SPME analysis for seven pyrethroids, including fenpropathrin, lambda-cyhalothrin, deltamethrin, fenvalerate, permethrin, tau-fluvalinate and bifenthrin in groundwater samples using high performance liquid chromatography combined with post-column photochemically induced fluorimetry derivatization and fluorescence detection (SPME-LC-PIF-FD). To perform the SPME, a 60 microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber was used for the extraction of the pesticides from groundwater samples. The main factors affecting the SPME process, such as extraction time, stirring rate, extraction temperature, pH and the desorption process were studied. The use of photochemically induced fluorescence for detection improved sensitivity and selectivity. The limits of quantification (LOQs) obtained in the matrix, with respect to EURACHEM Guidance, varied between 0.03 and 0.075 microgL(-1). Relative recoveries ranged from 92 to 109% and relative standard deviations values ranged from 2 to 9%.  相似文献   

15.
A solid-phase microextraction method (SPME) followed by gas chromatography with micro electron capture detection for determining trace levels of nitro musk fragrances in residual waters was optimized. Four nitro musks, musk xylene, musk moskene, musk tibetene and musk ketone, were selected for the optimization of the method. Factors affecting the extraction process were studied using a multivariate approach. Two extraction modes (direct SPME and headspace SPME) were tried at different extraction temperatures using two fiber coatings [Carboxen–polydimethylsiloxane (CAR/PDMS) and polydimethylsiloxane–divinylbenzene (PDMS/DVB)] selected among five commercial tested fibers. Sample agitation and the salting-out effect were also factors studied. The main effects and interactions between the factors were studied for all the target compounds. An extraction temperature of 100 °C and sampling the headspace over the sample, using either CAR/PDMS or PDMS/DVB as fiber coatings, were found to be the experimental conditions that led to a more effective extraction. High sensitivity, with detection limits in the low nanogram per liter range, and good linearity and repeatability were achieved for all nitro musks. Since the method proposed performed well for real samples, it was applied to different water samples, including wastewater and sewage, in which some of the target compounds (musk xylene and musk ketone) were detected and quantified. Figure Stardardized Pareto charts for the main effects and interactions  相似文献   

16.
Pontes M  Marques JC  Câmara JS 《Talanta》2007,74(1):91-103
The volatile composition from four types of multifloral Portuguese (produced in Madeira Island) honeys was investigated by a suitable analytical procedure based on dynamic headspace solid-phase microextraction (HS-SPME) followed by thermal desorption gas chromatography-quadrupole mass spectrometry detection (GC-qMS). The performance of five commercially available SPME fibres: 100 μm polydimethylsiloxane, PDMS; 85 μm polyacrylate, PA; 50/30 μm divinylbenzene/carboxen on polydimethylsiloxane, DVB/CAR/PDMS (StableFlex); 75 μm carboxen/polydimethylsiloxane, CAR/PDMS, and 65 μm carbowax/divinylbenzene, CW/DVB; were evaluated and compared. The highest amounts of extract, in terms of the maximum signal obtained for the total volatile composition, were obtained with a DVB/CAR/PDMS coating fibre at 60 °C during an extraction time of 40 min with a constant stirring at 750 rpm, after saturating the sample with NaCl (30%). Using this methodology more than one hundred volatile compounds, belonging to different biosynthetic pathways were identified, including monoterpenols, C13-norisoprenoids, sesquiterpenes, higher alcohols, ethyl esters and fatty acids. The main components of the HS-SPME samples of honey were in average ethanol, hotrienol, benzeneacetaldehyde, furfural, trans-linalool oxide and 1,3-dihydroxy-2-propanone.  相似文献   

17.
Two novel triptycene quinoxaline cavitands ( DiTriptyQxCav and MonoTriptyQxCav ) have been designed, synthesized, and applied in the supramolecular detection of benzene, toluene, ethylbenzene, and xylenes (BTEX) in air. The complexation properties of the two cavitands towards aromatics in the solid state are strengthened by the presence of the triptycene moieties at the upper rim of the tetraquinoxaline walls, promoting the confinement of the aromatic hydrocarbons within the cavity. The two cavitands were used as fiber coatings for solid‐phase microextraction (SPME) BTEX monitoring in air. The best performances in terms of enrichment factors, selectivity, and LOD (limit of detection) values were obtained by using the DiTriptyQxCav coating. The corresponding SPME fiber was successfully tested under real urban monitoring conditions, outperforming the commercial divinylbenzene–Carboxen–polydimethylsiloxane (DVB–CAR–PDMS) fiber in BTEX adsorption.  相似文献   

18.
In headspace (HS) analysis, a fumigant is released from a commodity into a gas-tight container by grinding, heating, or microwaves. A new technique uses HS-solid-phase microextraction (SPME) for additional preconcentration of fumigant. HS-SPME was tested for detection of phosphine (PH3), chosen for examination because of its wide use on stored commodities. PH3 was applied to 50 g wheat in separate 250 mL sealed flasks, which were equipped either with a septum for conventional HS analysis or with one of four HS-SPME fibers [100 microm polydimethylsiloxane (PDMS), 85 microm carboxen (CAR)/PDMS, 75 microm CAR/PDMS, and 65 pm PDMS/divinylbenzene (DVB)]. The wheat was heated at 45 degrees C for 20 min. In conventional HS analysis, a gaseous aliquot (80 pL) was taken from the HS and injected into the GC instrument. In the HS-SPME procedure, the fiber was removed from the HS and exposed in the heated injection port of the GC instrument. In all cases, PH3 was determined under the same chromatographic conditions with a GC pulsed flame photometric detector. In a comparison of the efficacy of the fibers, the bipolar fibers (CAR/PDMS and PDMS/DVB) contained more PH3 than the aliquot in the conventional HS analysis; larger size bipolar fibers extracted PH3 more efficiently than smaller fibers (e.g., 85 > 75 > 65 microm). The nonpolar fiber (PDMS) contained no PH3. Four fortification levels of PH3 on wheat were tested: 0.01, 0.05, 0.1, and 0.3 microg/g. The response of each bipolar fiber increased with the fortification levels, but the conventional HS analysis detected no fumigant at the lowest fortification level of 0.01 mg/g. Under the conditions of the validation study, the LOD was in the range of 0.005-0.01 ng PH3/g wheat.  相似文献   

19.
A new generation of solid-phase microextraction (SPME) fiber, an internally cooled fiber (cold fiber with polydimethylsiloxane loading) that allows heating the sample matrix and simultaneously cooling the fiber coating, was used to determine 2,4-dichloroanisole, 2,6-dichloroanisole, 2,4,6-trichloroanisole and pentachloroanisole in cork. A comparison between the cold fiber and regular SPME fiber was performed. An automated headspace solid-phase microextraction (HS-SPME) using commercial fibers and an internally cooled SPME fiber (CF-HS-SPME) coupled to gas chromatography-time-of-flight mass spectrometry (GC-TOF-MS) was used. The extraction conditions for both CF-HS-SPME and HS-SPME were optimized using full factorial design and Doehlert matrix. The best extraction conditions for CF-HS-SPME were obtained using 10 min of incubation time, 10 min of extraction time, and sample and fiber temperature of 130 and 10 degrees C, respectively. For HS-SPME, polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber was used with 10 min of incubation time, 75 min of extraction time, 85 degrees C of sample temperature, 8 ml of water was added and agitated at 500 rpm. The quantification limits for the target compounds using CF-HS-SPME procedure were between 0.8 and 1.6 ng g(-1) of cork, while for HS-SPME were between 4 and 6 ng g(-1) of cork. Furthermore, the CF-HS-SPME procedure could be used as a non-destructive method after minor modification of the agitator for the autosampler.  相似文献   

20.
Dynamic headspace solid-phase microextraction (HS-SPME) followed by thermal desorption gas chromatography-quadrupole mass spectrometry analysis (GC-qMS), was used to investigate the aroma profile of different species of passion fruit samples. The performance of five commercially available SPME fibres: 65 μm polydimethylsiloxane/divinylbenzene, PDMS/DVB; 100 μm polydimethylsiloxane, PDMS; 85 μm polyacrylate, PA; 50/30 μm divinylbenzene/carboxen on polydimethylsiloxane, DVB/CAR/PDMS (StableFlex); and 75 μm carboxen/polydimethylsiloxane, CAR/PDMS; was evaluated and compared. Several extraction times and temperature conditions were also tested to achieve optimum recovery. The SPME fibre coated with 65 μm PDMS/DVB afforded the highest extraction efficiency, when the samples were extracted at 50 °C for 40 min with a constant stirring velocity of 750 rpm, after saturating the sample with NaCl (17%, w/v — 0.2 g). A comparison among different passion fruit species has been established in terms of qualitative and semi-quantitative differences in volatile composition. By using the optimal extraction conditions and GC-qMS it was possible to tentatively identify seventy one different compounds in Passiflora species: 51 volatiles in Passiflora edulis Sims (purple passion fruit), 24 in P. edulis Sims f. flavicarpa (yellow passion fruit) and 21 compounds in Passiflora mollissima (banana passion fruit). It was found that the ethyl esters comprise the largest class of the passion fruit volatiles, including 82.8% in P. edulis variety, 77.4% in P. edulis Sims f. flavicarpa variety and 39.9% in P. mollissima.The semi-quantitative results were then submitted to principal component analysis (PCA) in order to establish relationships between the compounds and the different passion fruit species under investigation.  相似文献   