首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We report a simple and effective strategy for fabrication of the nanocomposite containing chitosan (CS) and multiwall carbon nanotube (MWNT) coated on a glassy carbon electrode (GCE). The characterization of the modified electrode (CS‐MWNT/GC) was carried out using scanning electron microscopy (SEM) and UV–vis absorption spectroscopy. The electrochemical behavior of CS‐MWNT/GC electrode was investigated and compared with the electrochemical behavior of chitosan modified GC (CS/GC), multiwalled carbon nanotube modified GC (MWNT/GC) and unmodified GC using cyclic voltammetry (CV) and electron impedance spectroscopy (EIS). The chitosan films are electrochemically inactive; similar background charging currents are observed at bare GC. The chitosan films are permeable to anionic Fe(CN)63?/4? (FC) redox couple. Electrochemical parameters, including apparent diffusion coefficient for the Fe(CN)63?/4? redox probe at FC/CS‐MWNT/GC electrode is comparable to values reported for cast chitosan films. This modified electrode also showed electrocatalytic effect for the simultaneous determination of D‐penicillamine (D‐PA) and tryptophan (Trp). The detection limit of 0.9 μM and 4.0 μM for D‐PA and Trp, respectively, makes this nanocomposite very suitable for determination of them with good sensitivity.  相似文献   

2.
《Electroanalysis》2017,29(2):497-505
An electrochemical sensor for the simultaneous and sensitive detection of Cd(II) and Pb(II) is proposed on the basis of square‐wave anodic stripping voltammetry (SWASV) experiments using a novel bismuth film/ordered mesoporous carbon‐molecular wire modified graphite carbon paste electrode (Bi/OMC‐MW/GCPE). Ordered mesoporous carbon (OMC) and molecular wire (MW) (diphenylacetylene) were used as the modifier and binder, respectively. The Bi/OMC‐MW/GCPE was prepared with the addition of graphite powder, OMC and DPA at the ratio of 2 : 1 : 1. The electrochemical properties and morphology of the electrode were characterized by electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), SWASV and scanning electron microscopy (SEM). The parameters affecting the stripping current response were investigated and optimized. The experimental results show that the prepared electrode exhibited excellent electrochemical performance, good electrical conductivity and a high stripping voltammetric response. Under optimized conditions, a linear range was achieved over a concentration range from 1.0 to 70.0 μg/L for both Cd(II) and Pb(II) metal ions, with detection limits of 0.07 μg/L for Cd(II) and 0.08 μg/L for Pb(II) (S/N=3) with the deposition time 150 s. Moreover, the sensor exhibited improved sensitivity and reproducibility compared to traditional CPEs. The fabricated electrode was then successfully used to satisfactorily detect Cd(II) and Pb(II) in real soil samples.  相似文献   

3.
An electrochemical oxidation of acetaminophen (ACOP) has been successfully performed by using glassy carbon electrode covered with 4-hydroxyquinoline-3-carboxylic acid (4HQ3CA) to reinforce electrode's feature. To characterize the modified electrode (4HQ3CA/GC), electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and Fourier transform infrared spectroscopy (FT-IR) techniques were used. The finding optimum conditions (supporting electrolyte, pH) and the electrochemical determination studies were performed with differential pulse voltammetry (DPV). It was decided that the supporting electrolyte medium suitable for ACOP determination was Britton-Robinson (BR) buffer and the effect of pH change on the oxidation peak of ACOP in this media was investigated. The effect of changing scan rate on the oxidation peak of ACOP was examined and this study showed that the oxidation process of ACOP on the 4HQ3CA/GC modified electrode surface was diffusion and adsorption controlled process. A wide concentration range from 0.0025 μM to 141 μM with a limit of detection (LOD) of 5.98×10−10 M (3 s/m) was obtained. This prepared sensor was carried out for the determination of ACOP in pharmaceutical sample.  相似文献   

4.
A glassy carbon (GC) electrode modified with silver pentacyanonitrosylferrate (AgPCNF) film as a redox mediator was fabricated. Cyclic voltammetry was used to study the redox property of AgPCNF modified electrode. The modified electrode showed a well‐defined redox couple due to [AgIFeIII/II(CN)5NO]1‐/2‐system. The effects of scan rates, supporting electrolytes and solution pHs were studied on the electrochemical behavior of the modified electrode. The feasibility of using the AgPCNF modified electrode to measure L ‐cysteine was investigated. It showed an excellent electrocatalytic activity towards the oxidation of L ‐cysteine and the anodic currents were proportional to the L ‐cysteine concentration in the range of 0.1 μM to 20 μM, the linear regression equation is Ipa(μA) = ‐68.58 ‐ 5.78CL ‐cysteine (μM), with a correlation coefficient 0.998 for N = 23. The detection limit was down to 3.5 × 10‐8 M (three times the ratio of signal to noise).  相似文献   

5.
A new kind of bismuth film modified electrode to sensitively detect trace metal ions based on incorporating highly conductive ionic liquids 1‐butyl‐3‐methyl‐imidazolium hexafluorophosphate (BMIMPF6) in solid matrices at glassy carbon (GC) was investigated. Poly(sodium 4‐styrenesulfonate) (PSS), silica, and Nafion were selected as the solid matrices. The electrochemical properties of the mixed films modified GC were evaluated. The electron transfer rate of Fe(CN)64?/Fe(CN)63? can be effectively improved at the PSS‐BMIMPF6 modified GC. The bismuth modified PSS‐BMIMPF6 composite film electrodes (GC/PSS‐BMIMPF6/BiFEs) displayed high mechanical stability and sensitive stripping voltammetric performances for the determination of trace metal cations. The GC/PSS‐BMIMPF6/BiFE exhibited well linear response to both Cd(II) and Pb(II) over a concentration range from 1.0 to 50 μg L?1. And the detection limits were 0.07 μg L?1 for Cd(II) and 0.09 μg L?1 for Pb(II) based on three times the standard deviation of the baseline with a preconcentration time of 120 s, respectively. Finally, the GC/PSS‐BMIMPF6/BiFEs were successfully applied to the determination of Cd(II) and Pb(II) in real sample, and the results of present method agreed well with those of atomic absorption spectroscopy.  相似文献   

6.
A simple electroanalytical method for Cd(II) and Pb(II) detection based on differential pulse anodic stripping voltammetry (DPSV) with in situ prepared antimony-modified glassy carbon rotating disk electrode (in situ Sb-GC-RDE) was developed. The electrochemical detection was performed in a microdroplet (50 μL) of 0.01 M hydrochloric acid that is placed between the electrode surface (top) and a Parafilm®-covered glass slide to maintain a hydrophobic surface (bottom). This method includes a preconcentration process using a membrane filter (MF). The target metal ions were complexed with 1-(2-pyridylazo)-2-naphthol (PAN) as a chelating agent, which was accumulated on the MF via filtration. The RDE microdroplet anodic stripping voltammetry was suitable for the elution and determination of metal ions accumulated on the MF. The in situ preparation of antimony-modified electrode allows the use of common GC electrode with high performance. The detection limits for Cd(II) and Pb(II) were 1.4 and 1.1 μg/L, respectively. The proposed method was successfully used in natural water samples for the simultaneous determination of Cd(II) and Pb(II).  相似文献   

7.
《Electroanalysis》2017,29(11):2507-2515
In the present study, a novel enzymatic glucose biosensor using glucose oxidase (GOx) immobilized into (3‐aminopropyl) triethoxysilane (APTES) functionalized reduced graphene oxide (rGO‐APTES) and hydrogen peroxide sensor based on rGO‐APTES modified glassy carbon (GC) electrode were fabricated. Nafion (Nf) was used as a protective membrane. For the characterization of the composites, Fourier transform infrared spectroscopy (FTIR), X‐ray powder diffractometer (XRD), and transmission electron microscopy (TEM) were used. The electrochemical properties of the modified electrodes were investigated using electrochemical impedance spectroscopy, cyclic voltammetry, and amperometry. The resulting Nf/rGO‐APTES/GOx/GC and Nf/rGO‐APTES/GC composites showed good electrocatalytical activity toward glucose and H2O2, respectively. The Nf/rGO‐APTES/GC electrode exhibited a linear range of H2O2 concentration from 0.05 to 15.25 mM with a detection limit (LOD) of 0.017 mM and sensitivity of 124.87 μA mM−1 cm−2. The Nf/rGO‐APTES/GOx/GC electrode showed a linear range of glucose from 0.02 to 4.340 mM with a LOD of 9 μM and sensitivity of 75.26 μA mM−1 cm−2. Also, the sensor and biosensor had notable selectivity, repeatability, reproducibility, and storage stability.  相似文献   

8.
An electrochemical sensor based on poly-ethionine (Poly-ET) film modified glassy carbon electrode was developed for sensitive and simultaneous sensing of dopamine (DA) and paracetamol (PA). The electropolymerization of ethionine monomer was carried out to modify the electrode. The modified electrode was characterized by using scanning electron microscopy, cyclic voltammetry and electrochemical impedance spectroscopy. The Poly-ET/GCE exhibited excellent electrocatalysis towards the sensing of DA and PA. Poly-ET/GCE showed a linear increase of current response with increase concentration of DA and PA ranging from 0.1 μM–60 μM and 0.1 μM–180 μM, respectively. The LODs were found to be 7 nM and 18 nM (S/N=3) for DA and PA, respectively. This electrochemical sensor was successfully utilized for the detection of DA and PA in pharmaceutical samples.  相似文献   

9.
Here we investigate the use of 3D printed graphene/poly(lactic acid) (PLA) electrodes for quantifying trace amounts of Hg, Pb, and Cd. We prepared cylindrical electrodes by sealing a 600 μm diameter graphene/PLA filament in a pipette tip filled with epoxy. We characterized the electrodes using scanning electron microscopy, Raman spectroscopy, and cyclic voltammetry in ferrocene methanol. The physical characterization showed a significant amount of disorder in the carbon structure and the electrochemical characterization showed quasi‐reversible behavior without any electrode pretreatment. We then used unmodified graphene/PLA electrode to quantify Hg, and Pb and Cd in 0.01 M HCl and 0.1 M acetate buffer using square wave anodic stripping voltammetry. We were able to quantify Hg with a limit of detection (LOD) of 6.1 nM (1.2 ppb), but Pb and Cd did not present measurable peaks at concentrations below ~400 nM. We improved the LODs for Pb and Cd by depositing Bi microparticles on the graphene/PLA and, after optimization, achieved clear stripping peaks at the 20 nM level for both ions (4.1 and 2.2 ppb for Pb2+ and Cd2+, respectively). The results obtained for all three metals allowed quantification below the US Environmental Protection Agency action limits in drinking water.  相似文献   

10.
The threat from chemical warfare agents (CWAs) imparts an alarming call for the global community not limited to human being but also extends as unprecedented environmental threat, hence, timely detection and degradation in the event of CWAs attack is very crucial. Herein, we describe a hybrid material of 3‐aminopropyltriethoxysilane (APTES) modified graphene oxide (GO) on glassy carbon (GC) electrode along with electrodeposited silver nanodendrimers (AgNDs) for the electrochemical detection and degradation of CWA sulphur mustard (HD). The AgNDs/APTES‐GO hybrid material was characterized by SEM, EDX, BET, TGA, Raman, UV‐Vis, XPS and XRD techniques. The AgNDs/APTES‐GO modified GC electrode was also characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Electrochemical studies indicated presence of electrocatalysis owing to the synergistic effect of AgNDs and GO for sensing CWA HD via reductive dehalogenation. The AgNDs/APTES‐GO modified GC electrode exhibited linearity for CWA HD from 5.3 μM to 42.4 μM. Constant potential electrolysis was performed with modified electrode and degradation products were analysed using GC‐MS, highlighting the great potential of graphene based hybrid material. This new strategy provides an opportunity for the development of “detect and destroy” system for the CWAs and other environmental toxic pollutant, which could help in mitigation of on‐ site events for first responders.  相似文献   

11.
An EDTA‐bonded conducting polymer modified electrode was prepared and characterized by FT‐IR. The modified electrode was used for the selective electrochemical analysis of various trace metal ions such as, Cu(II), Hg(II), Pb(II), Co(II), Ni(II), Fe(II), Cd(II), and Zn(II) at the different pHs by linear sweep and square wave voltammetry. Dynamic ranges were obtained using square wave voltammetry from 0.1 μM to 10.0 μM for Co(II), Ni(II), Cd(II), Fe(II), and Zn(II) and 0.5 nM to 20 nM for Cu(II), Hg(II), and Pb(II) after 10 min of preconcentration. The detection limits were determined to be 0.1 nM, 0.3 nM, 0.4 nM, 50.0 nM, 60.0 nM, 65.0 nM, 80.0 nM, and 90.0 nM for Cu(II), Hg(II), Pb(II), Co(II), Ni(II), Cd(II), Fe(II), and Zn(II), respectively. The technique offers an excellent way for the selective trace determination of various heavy metal ions in a solution.  相似文献   

12.
《Electroanalysis》2018,30(5):877-885
This work describes for the first time the employment of water soluble GSH‐ZnSe QDs stabilized by XG and MWCNT for electrode modification in the detection of Cd ions in a highly sensitive and selective manner resulting from the unique structure and surface chemistry of the used QDs. The surface of a glassy carbon (GC) electrode was modified through casting a thin layer of multiwalled carbon nanotubes (MWCNT) followed by a complex layer of ZnSe quantum dots (QDs) stabilized by xanthan gum (XG). Due to the electrocatalytic properties of MWCNT and electroanalytical performance of ZnSe‐XG complex, the new modified electrode significantly improves the sensitivity and selectivity of Cd(II) detection and exhibits enhanced performance in comparison to bare GC, ZnSe/GC and ZnSe/MWCNT/GC electrodes. Strong interactions between ZnSe QDs and XG resulting from hydrogen bonding and complexing association led to stabilization of ZnSe QDs and higher affinity towards Cd(II) ions adsorption compared to a ZnSe QDs film alone. The modified electrode showed linear response in a wide concentration range from 100 nM to 5 μM (R2=0.9967) along with a high sensitivity of 156.6 nA ⋅ mol−1 ⋅ L−1 and a low detection limit of 20 nM. The electrode shows high selectivity to Cd with negligible interference from other metal ions and salts.  相似文献   

13.
《Electroanalysis》2017,29(11):2602-2609
New silica‐modified glassy carbon electrodes prepared with three different sorts of ordered mesoporous silica (OMS) were characterized and tested for the electrochemical detection of Malachite Green (MG). The electrodes were prepared by drop casting using silica suspensions and, for stability sake, a Nafion coating was deposited on the electrode top by the same technique. Square wave anodic stripping voltammetry was used to investigate the effect of various experimental parameters (deposition time, solution pH, silica type and concentration) on the performance of the modified electrodes. The best electrode (GC/MCM‐41‐NH2/Nafion) with detection limit 0.36 μM, sensitivity 0.164±0.003 A/M; linear domain 1–6 μM was applied to detect MG in a commercial product commonly used as biocide in aquaria for ornamental fish.  相似文献   

14.
Multi‐wall carbon nanotubes (MWCNTs) and Nafion composite film (MWCNTs/Nafion) were used for fabricating electrochemical sensors for the voltammetric detection of trace lead(II) and cadmium(II) in several water samples. The morphology and structure of MWCNTs/Nafion film were characterized by scanning electron microscopy (SEM) and infrared spectrum (IR). The electron transfer of MWCNTs/Nafion composite film was examined by cyclic voltammetry (CV) and electrochemical impedance spectrum (EIS). Various experimental parameters, which influenced the response of MWCNTs/Nafion/GC to target metals, were optimized. The results showed that the synergistic effect was obtained on the MWCNTs/Nafion/GC whose sensitivity and stability were better than those of Nafion‐coated electrode (Nafion/GC) or CNTs/GC. Stability of the Pb(II) and Cd(II) stripping signals was excellent with relative standard deviations (RSD) within 5% (n=10) from one electrode preparation to another, and RSD of 30 µg·L?1 Pb(II) and Cd(II) were 2.8% and 3.2% for 20 repeated analysis on one single CNTs/Nafion/GC. Over 50 runs, the stability of Pb and Cd detection at the MWCNTs/Nafion conposites electrode was still satisfactory with RSD lower than 6.0%. The determination limits (S/N=3) of the proposed method were determined to be 100 ng·L?1 for Pb and 150 ng·L?1 for Cd. Finally, the MWCNTs/Nafion/GC was successfully applied to determine Pb(II) and Cd(II) in different water samples with recoveries of 97%–103% for Pb and 96%–104% for Cd.  相似文献   

15.
《Electroanalysis》2004,16(8):674-683
The cobalt hexacyanoferrate film (CoHCF) was deposited on the surface of a glassy carbon (GC) electrode with a potential cycling procedure in the presence and absence of the cationic surfactant, cetyl trimethylammonium bromide (CTAB), to form CoHCF modified GC (CoHCF/GC) electrode. It was found that CTAB would affect the growth of the CoHCF film, the electrochemical behavior of the CoHCF film and the electrocatalytic activity of the CoHCF/GC electrode towards the electrochemical oxidation of dopamine (DA). The reasons of the electrochemical behavior of CoHCF/GC electrode influenced by CTAB were investigated using FTIR and scanning electron microscope (SEM) techniques. The apparent rate constant of electrocatalytic oxidation of DA catalyzed by CoHCF was determined using the rotating disk electrode measurements.  相似文献   

16.
Multiwall carbon nanotubes were dispersed in Nafion (MWCNTs‐NA) solution and used in combination with bismuth (MWCNTs‐NA/Bi) for fabricating composite sensors to determine trace Pb(II) and Cd(II) by differential pulse anodic stripping voltammetry (DPASV). The electrochemical properties of the MWCNTs‐NA/Bi composites film modified glassy carbon electrode (GCE) were evaluated. The synergistic effect of MWCNTs and bismuth composite film was obtained for Pb(II) and Cd(II) detection with improved sensitivity and reproducibility. Linear calibration curves ranged from 0.05 to 100 μg/L for Pb(II) and 0.08 to 100 μg/L for Cd(II). The determination limits (S/N=3) were 25 ng/L for Pb and 40 ng/L for Cd, which compared favorably with previously reported methods in the area of electrochemical Pb(II) and Cd(II) detection. The MWCNTs‐NA/Bi composite film electrodes were successfully applied to determine Pb(II) and Cd(II) in real sample, and the results of the present method agreed well with those of atomic absorption spectroscopy.  相似文献   

17.
An electrochemical sensor for the simultaneous determination of Cd(II) and Pb(II) by square wave anodic stripping voltammetry (SWASV) in bivalve mollusks using a glassy carbon electrode modified with electrochemically reduced graphene oxide has been developed. The modified surface was characterized by cyclic voltammetry, high resolution scanning electron microscopy (HR‐SEM), and Raman spectroscopy. The optimum conditions were optimized and a linear range was observed from 15–105 μg L?1 with a limits of detection of 15 μg L?1 for Cd(II) and Pb(II). The methodology was validated and applied in different samples of commercial bivalve mollusks with satisfactory results. The high conductivity and greater surface area of the modifying agent improves the preconcentration capacity of the electrochemical sensor, allowing to develop a simple, rapid and sensitive analysis in the detection of lead and cadmium in marine resources.  相似文献   

18.
The glassy carbon (GC) electrode modified with Nafion and Safranin O (SFO) was prepared and its electrochemical properties were investigated. The SFO molecules were strongly and irreversibly adsorbed on the Nafion — modified GC surface. The electrochemical behavior and mechanism for interactions of the SFO molecules with the Nafion film were investigated through cyclic voltammetric method. The electrocatalytic reduction of nitric oxide was performed at this modified electrode by cyclic voltammetric and hydrodynamic amperometric techniques. The Nafion membrane played a duel role as a matrix for the SFO immobilization and also helped to partition the nitric oxide from the solution phase. The diffusion coefficient of NO at the SFO/Nafion/GC modified electrode was calculated using chronoamperometry. The dependence of response currents on the concentration of NO was examined and was linear in the range of 0.05–1.9 mM of NO.  相似文献   

19.
A promising electrochemical sensor based nickel‐carbon nanotube (Ni‐CNT) modified on glassy carbon (GC) electrode had been developed and the properties of the modified electrode were characterized by multispectroscopic analysis. The fabricated sensor (GC/Ni‐CNT) electrode was utilized to determine the catecholamines such as epinephrine and dopamine simultaneously. Differential pulse voltammetry and amperometry were used to verify the electrochemical behavior of the studied compounds. The GC/Ni‐CNT based amperometric sensor showed a wide linear range and low detection limit with high analytical sensitivity of 8.31 and 6.61 μA μM?1 for EP and DA, respectively which demonstrates better characteristics compared to other electrodes reported in the literature. Further, no significant change in amperometric current response was observed in presence of biological interference species such as glucose, cysteine, citric acid, uric acid and ascorbic acid in the detection of EP and DA. The utility of this GC/Ni‐CNT electrode was well established for the determination of EP and DA in human urine samples.  相似文献   

20.
Demet Uzun 《Electroanalysis》2021,33(7):1699-1706
In this present study, to determine paracetamol, an electroanalytical method is presented using differential pulse voltammetry (DPV) at 3-amino-4H-1,2,4-triazole (3AT) coated glassy carbon (GC) electrode. The electrochemical characterization and electron transfer behavior of this prepared electrode in the mixture of K4[Fe(CN)6]/K3[Fe(CN)6] contains 0.1 M KCl was confirmed by using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) methods. Furthermore, scanning electron microscopy (SEM) was used to observe morphological structures of the bare and modified surfaces. The effect of pH was studied on the redox reaction of paracetamol in phosphate buffer in the range of pH 3.0–9.0. The limit of detection was 0.043 μM (3 s/m) for 3AT-GC electrode. The developed electrode was successfully utilized in pharmaceutical samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号