首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
In this study, methodology was developed for on-line and miniaturized enzymatic digestion with liquid chromatographic (LC) separation and mass spectrometric (MS) detection. A packed capillary LC-MS system was combined with on-line trypsin cleavage of a model protein, lactate dehydrogenase, to provide an efficient system for peptide mapping. The protein was injected onto an enzymatic capillary reactor and the resulting peptides were efficiently trapped on a capillary trapping column. Different trapping columns were evaluated to achieve a high binding capacity for the peptides generated in the enzyme reactor. The peptides were further eluted from the pre-column and separated on an analytical capillary column by a buffer more suitable for the following an electrospray ionisation (ESI) MS process. An important aspect of the on-line approach was the desalting of peptides performed in the trapping column to avoid detrimental signal suppression in the ESI process. The developed on-line system was finally compared to a classical digestion in solution, with reference to peptide sequence coverage and sensitivity. It was shown that the on-line system gave more than 100% higher peptide sequence coverage than traditional digestion methods.  相似文献   

3.
In finding suitable biocatalysts for processes in chemical industry, expression libraries are constructed containing typically >10,000 clones. Search for a desired activity is done by examination of all the clones in one or more libraries using a high-throughput screening assay. Here we describe a method for the screening of the enzymatic racemase activity of clones from an expression library on alpha-amino-epsilon-caprolactam (ACL) using a fast chiral LC separation and ionspray-MS as the detection technique. After substrate incubation with S-ACL, the 96-well microplates were centrifuged to remove cell material. The conversion of S-ACL to R-ACL was monitored by quantitation of the R-ACL enantiomer. Separation of the two ACL enantiomers was performed on a Crownpak CR+ column within 1 min. A Gilson 215 autosampler with a 889 multiple injection probe was used for injecting the samples into the LC system. The total analysis time for a 96-well microplate was 56 min. The MS was operated in the positive-ion mode using selected ion monitoring at m/z 129 [M+H]+ of ACL. Using this method over 12,000 samples were analyzed without loss in performance of the system. The LC column remained stable without loss of resolution and the MS system did not show loss in sensitivity throughout the screening. Inter-day reproducibility was within 15%.  相似文献   

4.
This work proposes, for the first time, the use of a high intensity ultrasonic probe to accelerate the tryptic digestion of soybean proteins. Different digestion parameters were optimized: protein extracting solution, reduction, and alkylation conditions (time, concentration, and temperature), trypsin:protein ratio, and ultrasonic conditions (sonication amplitude and time). Separation of peptide profiles was carried out by capillary-HPLC. The effect of the variation of chromatographic conditions (elution gradient, column temperature, and injection volume) on peptide separation was also studied using two capillary-HPLC columns with different column diameters and particle sizes. Moreover, samples were focused at the top of the column in order to obtain an increasing sensitivity without loss of efficiency. This method was successfully applied to the profiling of soybean peptides from transgenic and non-transgenic soybeans and from different pigmented beans commercialized as soybeans.  相似文献   

5.
Liquid chromatography mass spectrometry (LC-MS) peptide mapping can be a versatile technique for characterizing protein glycosylation sites without the need to remove the attached glycans as in conventional oligosaccharide mapping methods. In this way, both N-linked and O-linked sites of glycosylation can each be directly identified, characterized, and quantified by LC-MS as intact glycopeptides in a single experiment. LC-MS peptide mapping of the individual glycosylation sites avoids many of the limitations of preparing and analyzing an entire pool of released N-linked oligosaccharides from all sites mixed together. In this study, LC interfaced to a linear ion trap mass spectrometer (ESI-LIT-MS) were used to characterize the glycosylation of a recombinant IgG1 monoclonal antibody and a CTLA4-Ig fusion protein with multiple sites of N-and O-glycosylation. Samples were reduced, S-carboxyamidomethylated, and cleaved with either trypsin or endoproteinase Asp-N. Enhanced detection for minor IgG1 glycoforms (~0.1 to 1.0 mol% level) was obtained by LC-MS of the longer 32-residue Asp-N glycopeptide (4+ protonated ion) compared to the 9-residue tryptic glycopeptide (2+ ion). LC-MS peptide mapping was run according to a general procedure: (1) Locate N-linked and/or O-linked sites of glycosylation by selected-ion-monitoring of carbohydrate oxonium fragment ions generated by ESI in-source collision-induced dissociation (CID), i.e. 204, 366, and 292 Da marker ions for HexNAc, HexNAc-Hex, and NeuAc, respectively; (2) Characterize oligosaccharides at each site via MS and MSMS. Use selected ion currents (SIC) to estimate relative amounts of each glycoform; and (3) Measure the percentage of site-occupancy by searching for any corresponding nonglycosylated peptide.  相似文献   

6.
A platform for rapid on-line protein digestion of protein mixtures for direct infusion to a mass spectrometer is presented. A mixture of protein A, staphylococcal enterotoxin B and cytochrome c was used as a model mixture injected on a gel filtration column and a trypsin reactor which were connected in series to a micro liquid chromatography (microLC) system. The peptides in the column eluate were analyzed with ESI tandem mass spectrometry, utilizing information dependent acquisition (IDA). In one step, the proteins in the mixture (microM concentrations) were concomitantly desalted, separated, digested and identified with an overall analysis time of less than 40 min. Protein sequence coverage of 78-95% for the involved substances was achieved.  相似文献   

7.
Optimized operating conditions previously developed for the determination of neuroactive indoleamines and metabolites were adapted to meet the requirements of thermospray liquid chromatography-mass spectrometry (LC-MS) in terms of the ammonium acetate buffer system needed in this technique. Mass spectra were obtained for nineteen indolic compounds in both the positive and negative ion modes. The positive thermospray mass spectra of indoles with a free primary amino group are characterized by the base peak at [M + H]+, whereas the alcohol and acid metabolites show the base peak at [M + NH4]+. In the negative mode only amino acids and acids give good mass spectra with base peaks at [M - H + ACOOH]-. Detection limits by selected ion monitoring were of the order of 50-100 pg SIM on-column, allowing the direct determination of endogenous serotonin in an extract from rat hypothalamus. Quantitation was performed by isotope dilution MS. In the same way 5-hydroxyindoleacetic, indoleacetic, indolepropionic and indolelactic acids in urine were directly determined in an ethyl acetate extract from acidified urine samples. Likewise, gamma-aminobutyric acid and tricyclic antidepressants gave detection limits of 10 pg whereas only nanogram sensitivity could be achieved with catecholamines.  相似文献   

8.
A reversed-phase HPLC method for the analysis of degradation products of the model aspartyl tripeptides Phe-Asp-GlyNH2 and Gly-Asp-PheNH2 after incubation at pH 2 and 10 was developed. Most of the compounds could be separated with a gradient of acetonitrile in water containing 0.1% trifluoroacetic acid. Resolution of the isomeric pairs L-Phe-alpha-L-Asp-GlyNH2/L-Phe-beta-L-Asp-GlyNH2 and L-Phe-alpha-D-Asp-GlyOH/L-Phe-beta-D-Asp-GlyOH was achieved with a gradient of acetonitrile in phosphate buffer, pH 5.0. Under acidic conditions the major degradation pathway was cleavage of the peptide backbone amide bonds yielding dipeptides and amino acids, C-terminal deamidation as well as formation of succidinimyl peptides. At alkaline pH both deamidation of the C-terminal amide as well as isomerization and concomitant enantiomerization of Asp were observed. The peaks were identified both by reference substances and by online electrospray mass spectrometry. The results were compared to a previous developed capillary electrophoresis method. Diastereomeric pairs ofpeptides that could not be separated by capillary electrophoresis were resolved by HPLC while the separation of corresponding pairs of alpha- and beta-Asp peptides was not always achieved by HPLC in contrast to capillary electrophoresis illustrating that both techniques can be complimentary in peptide analysis.  相似文献   

9.
He H  Shi X  Chen J  Gao P  Lei Y  Xu G 《色谱》2012,30(3):245-251
口腔癌的发病率占全身恶性肿瘤的第6位,正确区分正常状态与良性和恶性口腔肿瘤,是恰当选择治疗方案的关键所在。本研究中,首先利用液相色谱-质谱和气相色谱-质谱联用方法分别得到健康人、良性口腔肿瘤患者和恶性口腔肿瘤患者血浆、尿液和唾液的代谢轮廓,然后应用正交信号校正的偏最小二乘法进行多变量统计分析。结果表明健康人、良性肿瘤患者和恶性肿瘤患者在血浆、尿液和唾液等3种体液代谢中都可以被区分开,而且找到和鉴定出19个重要差异代谢物。相关代谢通路分析显示,与健康人相比,良性和恶性口腔肿瘤患者都存在能量代谢紊乱和脂类代谢失衡的现象,但恶性口腔肿瘤患者还表现出三羧酸循环和肌醇代谢异常,这为临床诊断及治疗提供了重要信息。  相似文献   

10.
Characterization of recombinant protein purification fractions and final products by liquid chromatography-mass spectrometry (LC/MS) are requested more frequently each year. A protein open-access (OA) LC/MS system was developed in our laboratory to meet this demand. This paper compares the system that we originally implemented in our facilities in 2003 to the one now in use, and discusses, in more detail, recent enhancements that have improved its robustness, reliability, and data reporting capabilities. The system utilizes instruments equipped with reversed-phase chromatography and an orthogonal accelerated time-of-flight mass spectrometer fitted with an electrospray source. Sample analysis requests are accomplished using a simple form on a web-enabled laboratory information management system (LIMS). This distributed form is accessible from any intranet-connected company desktop computer. Automated data acquisition and processing are performed using a combination of in-house (OA-Self Service, OA-Monitor, and OA-Analysis Engine) and vendor-supplied programs (AutoLynx, and OpenLynx) located on acquisition computers and off-line processing workstations. Analysis results are then reported via the same web-based LIMS. Also presented are solutions to problems not addressed on commercially available, small-molecule OA-LC/MS systems. These include automated transforming of mass-to-charge (m/z) spectra to mass spectra and automated data interpretation that considers minor variants to the protein sequence-such as common post-translational modifications (PTMs). Currently, our protein OA-LC/MS platform runs on five LC/MS instruments located in three separate GlaxoSmithKline R&D sites in the US and UK. To date, more than 8000 protein OA-LC/MS samples have been analyzed. With these user friendly and highly automated OA systems in place, mass spectrometry plays a key role in assessing the quality of recombinant proteins, either produced at our facilities or bought from external sources, without dedicating extensive amounts of analyst resource.  相似文献   

11.
The utility of the combination of separations techniques, such as liquid chromatography and capillary zone electrophoresis, with mass spectrometry in applications involving protein analysis is discussed. The use of continuous-flow fast atom bombardment and electrospray ionization mass spectrometry is compared for the analysis of tryptic digests. For liquid chromatography, both microbore and slurry-packed capillary bore columns were used to separate peptides from proteolytic digests.  相似文献   

12.
A procedure has been developed for the detection and characterization of ribose-methylated dinucleotides of the type NmpN' in enzymatic digests of RNA. Differences in reaction products from hydrolysis using RNase T2, which will not cleave NmpN', and hydrolysis by nuclease P1 are analyzed by thermospray liquid chromatography-mass spectrometry. The method is applicable to dinucleotides present in nanogram range quantities and is suited for the characterization of new or unexpected ribose-methylated nucleotides for which chromatographic mobilities are not known.  相似文献   

13.
Summary Disaccharide fragments resulting from the enzymatic digestion of heparins with heparinase have been purified by gel filtration chromatography and directly analyzed by positive and negative ion liquid secondary ion mass spectrometry (LSIMS). Following the chromatographic purification from excess sodium salt, the mass spectra of di- and tetrasaccharide fragment mixtures enabled the identification of up to three covalently bound sulfate moieties per glycosaminoglycan-disaccharide unit, by means of their molecular ions, containing the corresponding alkali-counterions.
Charakterisierung von Disaccharidfragmenten aus dem enzymatischen Heparinaufschluß mit Hilfe der Flüssig-Sekundärionen-Massenspektrometrie
  相似文献   

14.
On-line digestion of proteins under acidic conditions was studied using micro-reactors consisting of dextran-modified fused-silica capillaries with covalently immobilized pepsin. The proteins used in this study differed in molecular weight, isoelectric point and sample composition. The injected protein samples were completely digested in 3 min and the digest was analyzed with micro-high performance liquid chromatography (HPLC) and tandem mass spectrometry (MS/MS). The different proteins present in the samples could be identified with a Mascot database search on the basis of auto-MS/MS data. It proved also to be possible to digest and analyze protein mixtures with a sequence coverage of 55% and 97% for the haemoglobin β- and α-chain, respectively, and 35-55% for the various casein variants. Protease auto-digestion, sample carry-over and loss of signal due to adsorption of the injected proteins were not observed. The backpressure of the reactor is low which makes coupling to systems such as Surface Plasmon Resonance biosensors, which do not tolerate too high pressure, possible. The reactor was stable for at least 40 days when used continuously.  相似文献   

15.
A new analytical method, using gas chromatography-mass spectrometry (GC/MS) and liquid chromatography-mass spectrometry (LC/MS) techniques, was developed for the determination in packaged food beverages of five ink photoinitiator residues: 2-isopropylthioxanthone (ITX), benzophenone, 2-ethylhexyl-4-dimethylaminobenzoate (EHDAB), 1-hydroxycyclohexyl-1-phenyl ketone (IRGACURE 184) and ethyl-4-dimethylaminobenzoate (EDAB). Samples were extracted from selected beverages (milk, fruit juices and wine) and relative packagings, using n-hexane and dichloromethane, respectively, purified on solid-phase extraction (SPE) silica gel cartridges, and then analyzed in GC/MS and LC/MS. The recovery percentages, obtained spiking the beverage samples at concentrations of 4 and 10 microgl(-1) with a standard mixture of photoinitiators, were in the range 42-108% (milk), 50-84% (wine), and 48-109% (fruit juices). The repeatability of the method was assessed in all cases by the % of correlation value, that was lower than 19%. The lowest limits of detection (LODs) and limits of quantification (LOQs), obtained using GC/MS, were in the range 0.2-1 and 1-5 microgl(-1), respectively. The method was applied to the analysis of forty packaged food beverages (milk, fruit juices and wine samples). The most significant contamination was that of benzophenone, found in all samples in a concentration range of 5-217mugl(-1). Its presence was confirmed by an LC/Atmospheric-Pressure PhotoIonization (APPI)/MS/MS analysis. The photoinitiator (EHDAB) was found in eleven out of forty beverages in a concentration range of 0.13-0.8 microgl(-1). Less important was the ITX contamination, found in three out of forty samples in a range 0.2-0.24 microgl(-1). The work proposes a new method to analyze ink photoinitiator residues in polycoupled carton packaging and in contained food beverages.  相似文献   

16.
A simple and easy-to-use extraction method for aqueous samples based on hollow fibre-supported liquid membrane (HF-SLM) followed by liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) was developed to determine ivermectin and transformation products, the monosaccharide (TP1) and the aglycon of ivermectin (TP2). The proposed method attained enrichment factors up to 80, after optimising parameters, such as fibre length, organic solvent, stirring speed, salt level, pH in samples/fibre, extraction time and fibre emptying technique. Method validation with tap and lake water samples provided good linearity and detection limits of 0.2, 1.6 and 0.9 microg/l for ivermectin, TP1 and TP2 in lake water with RSD below 15%.  相似文献   

17.
Thermospray liquid chromatography-mass spectrometry has been applied in the solution of a number of problems of biological and biomedical interest. These include the analysis of phenazines from the Gram negative bacterium Pseudomonas aeruginosa, steroids released by rat adrenals and eicosanoids generated by human inflammatory cells. The application of the technique to leukotrienes in blood is discussed. Isotopic labelling prior to analysis, to facilitate identification and structure elucidation is outlined with reference to the steroids.  相似文献   

18.
A high-performance liquid chromatographic method was developed for thermospray mass spectrometric analysis of steroidal hormones. Using a Nova-Pak C18 reversed-phase column and isocratic elution with a solvent comprised of 25 mM ammonium formate in 30% acetonitrile, corticosteroids were separated within 10 min. This solvent also permitted ultraviolet absorbance detection down to 220 nm with low-nanogram sensitivity. The use of acetonitrile was favourable for thermospray mass spectrometric analysis because mass spectra were obtained with a pseudomolecular ion as the base peak. A combination of liquid chromatography, ultraviolet absorbance detection and thermospray mass spectrometry provided a sensitive and reliable method for unequivocal confirmation of the presence of steroidal drugs in equine urine.  相似文献   

19.
In this article, we developed a membrane-based enzyme micro-reactor by directly using commercial polystyrene–divinylbenzene cation–exchange membrane as the support for trypsin immobilization via electrostatic and hydrophobic interactions and successfully applied it for protein digestion. The construction of the reactor can be simply achieved by continuously pumping trypsin solution through the reactor for only 2 min, which was much faster than the other enzyme immobilization methods. In addition, the membrane reactor could be rapidly regenerated within 35 min, resulting in a “new” reactor for the digestion of every protein sample, completely eliminating the cross-interference of different protein samples. The amount and the activity of immobilized trypsin were measured, and the repeatability of the reactor was tested, with an RSD of 3.2% for the sequence coverage of cytochrome c in ten digestion replicates. An integrated platform for protein analysis, including online protein digestion and peptide separation and detection, was established by coupling the membrane enzyme reactor with liquid chromatography–quadrupole time-of-flight mass spectrometry. The performance of the platform was evaluated using cytochrome c, myoglobin, and bovine serum albumin, showing that even in the short digestion time of several seconds the obtained sequence coverages was comparable to or higher than that with in-solution digestion. The system was also successfully used for the analysis of proteins from yeast cell lysate.  相似文献   

20.
Nowadays, the need to have a realistic characterization of industrial effluents in the environment has become more and more recognized. A palette of different analytical methods both for sample extraction and instrumental analysis are available today, some older, others introduced more recently. The aim of this research is to compare a number of these techniques. To do this we studied a real leachate from an industrial landfill and carried out chemical analyses for organic pollutants, using different extraction methods based on solid-phase extraction and solid-phase microextraction and different instrumental techniques such as GC-MS, LC-MS, NMR and LC-NMR. Results show the performances of the different techniques, which are complementary.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号