首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Atmospheric polycyclic aromatic hydrocarbons are ubiquitous environmental pollutants, which may be present both in the gaseous phase and adsorbed onto the surface of particles. Denuders are sampling devices which have been effectively employed in such partitioning applications. Here we describe and characterise a novel miniature denuder consisting of two multi-channel silicone rubber traps (each 178 mm long, 6 mm o.d. containing 22 silicone tubes), separated by a quartz fibre filter for particle phase collection. The denuder only requires a small portable personal sampling pump to provide sampling flow rates of ∼0.5 L min−1. Theoretical considerations indicated that the air flow through the denuder was expected to be laminar, and the linear velocity arising from longitudinal diffusion was found to be negligible. The calculated particle transmission efficiency through the denuder was found to be essentially 100% for particles > 50 nm, whilst the experimental overall efficiency, as determined by CPC and SMPS measurements, was 92 ± 4%. The size resolved transmission efficiency was <60% for particles below 20 nm and 100% for particles larger than 200 nm. Losses could have been due to diffusion and electrostatic effects. Semi-volatile gaseous analytes are pre-concentrated in the silicone of the trap and may be thermally desorbed using a commercially available desorber, allowing for total transfer and detection of the collected analytes by GC–MS. This enhances detection limits and allows for lower sampling flow rates and shorter sampling times, which are advantageous for studies requiring high temporal resolution.  相似文献   

2.
Pressurised liquid extraction (PLE) was applied to determine the atmospheric levels of 16 polycyclic aromatic hydrocarbons (PAHs) in the gas and particulate phases. The method involved high‐volume air sampling with quartz fibre filters (QFFs) and polyurethane foam (PUF) plugs and analytes were subsequently extracted from the samples by PLE, and determined with GC‐MS. We optimised the PLE conditions for the solvent, the number of cycles and extraction temperature. Recoveries were higher than 90% for most compounds. Method LODs and LOQs were between 0.001 and 0.02 ng/m3 and between 0.01 and 0.05 ng/m3. Air samples were taken from a site in the region of Tarragona in Catalonia, Spain, where one of the largest petrochemical complexes in southern Europe is located. The total concentration of PAHs were from 6.7 to 27.66 ng/m3, with predominant levels of PAHs appearing in the gas phase (48–81%), and an average level of benzo[a]pyrene, the most carcinogenic PAH, of 0.86 ng/m3.  相似文献   

3.
Summary Due to the carcinogenity and ubiquity of polycyclic aromatic hydrocarbons in the environment they are of ongoing interest to analytical chemistry. In this study, a comparison of the classic Soxhlet extraction and, fluidized-bed extraction, has been conducted. The extraction of polycyclic aromatic hydrocarbons by this technique has been optimized considering as experimental variables the variation of the number of extraction cycles and the holding time after reaching the heating temperature by means of a surface response design. The significance of the operational parameters of the fluidized-bed extraction on the performance characteristics has been investigated. For the determination of the analytes a selective clean-up of the extracts followed by a fast gas chromatography method with mass spectrometric detection was used, resulting in low limits of detection (0.2 pg μL−1). The accuracy of the complete analytical method was established by extraction and analysis of reference materials.  相似文献   

4.
In this review, we focus on the status of the monitoring of polycyclic aromatic hydrocarbons (PAHs) in ambient air as well as in living (indoor) and working environments in Africa from 2000 to 2018. This is important as PAHs are ubiquitous in the environment and are known to be potentially carcinogenic. Aspects of sampling such as collection media for particle bound and gaseous PAHs are discussed. The efficiency and basic quality assurance data of commonly employed extraction techniques for separating target PAHs from sampling media using conventional solvent-based and emerging solvent-free approaches were also evaluated. Polyurethane foam and quartz fiber filters are generally the most commonly used collection media for gaseous and particle bound PAHs, respectively. A wide range of total PAH concentrations in ambient air has been reported across the continent of Africa, with the highest levels found at sampling sites close to high density traffic and industrial areas. A rapidly increasing population, commercial and industrial development, poor urban transportation infrastructure and the use of low quality oil products were the main causes of high total gas and particulate PAH concentrations (1.6–103 μg/m3) in West African port cities such as Cotonou, Benin. With regards to indoor environments, gas phase PAHs were detected at the highest total concentrations in rural areas ranging from 1 to 43 μg/m3 in Burundi with naphthalene being the most prevalent. Firewood burning was the major emission source in most developing countries and resulted in benzo[a]pyrene concentrations above the European permissible risk level of 1 ng/m3.  相似文献   

5.
A method has been developed for the trace analysis of polycyclic aromatic hydrocarbons, which are known as persistent organic pollutants and ubiquitous constituents of fine particulate matter that causes growing airborne pollution. The method, which was especially for samples of airborne particulate matter less than 2.5 μm in diameter, utilized accelerated solvent extraction and ultra high performance liquid chromatography with fluorescence detector. Four principal parameters of accelerated solvent extraction were optimized to obtain maximum extraction efficiency. Using the established synergetic programs of gradient elution and fluorescence wavelength switching, a rapid separation was achieved in 6.56 min with good linearity for 15 polycyclic aromatic hydrocarbons (coefficient of determination above 0.999). The limits of detection ranged from 0.833 to 10.0 pg/m3. The precision of the method expressed as inter‐day relative standard deviation ranged from 0.2 to 1%, which was calculated from nine repetitive measurements of 8.00 μg/L analytes. Average spiked recoveries ranged from 71.6 to 97.7%, with the exception of naphthalene. The rapid, sensitive, and accurate method can meet the pressing needs of health risk assessment and increasingly heavy daily tasks of air quality monitoring.  相似文献   

6.
Pressurised microwave-assisted extraction was used to extract a complex mixture containing polycyclic aromatic hydrocarbons (PAHs), nitrated PAHs and heavy n-alkanes from a particularly refractory carbonaceous material resulting from the combustion in a diesel engine. A second-order central composite design was used to determine the optimal conditions of extraction in terms of time, temperature, volume and nature of extracting solvent from spiked diesel soots. To begin, methylene chloride, tetrahydrofuran and chloroform were tested for extracting the spiked diesel particulates; however, the nature of these solvents was not really an influential factor. Volume was the most influential factor and was kept at a medium level to enhance the extraction of heavy PAHs without introducing an important dilution factor. Temperature and time were not influential as main factors but interacted with the other factors. Finally, high temperature and duration associated with a medium volume of methylene chloride were better for the extractions. After this optimisation, five-ring and six-ring PAHs were nevertheless not satisfactorily desorbed. Other solvents were therefore tested. Only aromatic ones, and particularly heterocyclic aromatic solvents, managed to desorb the heaviest PAHs. Pyridine, with its both aromatic and its basic character, was the most successful solvent. Desorption was even complete with an addition of 17% of diethylamine into pyridine. So, using MAE, we succeeded in extracting quantitatively, from the spiked refractory diesel soot surface, two-ring to six-ring PAHs, heavy n-alkanes and short nitrated PAHs. However, heavy nitrated PAHs were better extracted with a small addition of acetic acid (1%) into pyridine instead of a basic cosolvent.  相似文献   

7.
A method for monitoring the contamination of soil with polycyclic aromatic hydrocarbons (PAHs) is introduced. Drying at elevated temperature is omitted to avoid losses of the more volatile constituents (primarily naphthalene). The soil sample, including its natural water content, is extracted with 2-methoxyethanol and cleaned up using a disposable C8 cartridge and the PAHs are eluted with pentane, concentrated and measured by capillary gas chromatography with flame ionization detection. Determination limits between 15 and 35μg kg?1 are obtained and the recovery is 80–90% measured at the 125 μg kg?1 spike level, except for naphthalene (66%). Special attention is given to the design of the spiking technique, which simulates natural incorporation as far as possible, takes account of evaporation losses and therefore allows “real” recovery rates to be determined.  相似文献   

8.
Polyaniline coated cigarette filters were successfully synthesized and used as a solid‐phase extraction sorbent for the extraction and preconcentration of polycyclic aromatic hydrocarbons in water samples. The polyaniline helped to enhance the adsorption ability of polycyclic aromatic hydrocarbons on the sorbent through π–π interactions. The high porosity and large surface area of the cigarette filters helped to reduce backpressure and can be operated with high sample flow rate without loss of extraction efficiency. The developed sorbent was characterized by Fourier transform infrared spectroscopy and scanning electron microscopy. The parameters that affected the extraction efficiencies, i.e. polymerization time, type of desorption solvent and its volume, sample flow rate, sample volume, sample pH, ionic strength, and organic modifier were investigated. Under the optimal conditions, the method was linear over the range of 0.5–10 μg/L and a detection limit of 0.5 ng/L. This simple, rapid, and cost‐effective method was successfully applied to the preconcentration of polycyclic aromatic hydrocarbons from water samples. The developed method provided a high enrichment factor with good extraction efficiency (85–98%) and a relative standard deviation <10%.  相似文献   

9.
Polycyclic aromatic hydrocarbons (PAHs) were analyzed as adsorbates on borosilicate glass at levels from 40 pg (5.5 pg mm−2) to 7 μg (1 μg mm−2) using laser desorption-ionization (LDI) in air at ambient pressure and 100 °C with ion characterization by mobility spectrometry. Gas-phase positive ions with distinctive mobilities were produced from six PAHs using an unfocused beam at 266 nm, 6 mJ pulse−1 and 10 Hz from a Nd-YAG laser. The ions produced were identified as M+ using mass spectrometry (MS) with a LDI source at atmospheric pressure. The mobility spectrometry drift tube provided low memory effects and allowed observation of time-resolved intensity profiles for ion signals, and changes in this behavior with loading level suggested intermolecular interactions from multilayer formation. Mobility peaks were broader than those seen in gas-phase reactions, and this was attributed to Coulombic repulsion caused by the small volume near the surface where ionization would take place. An ion shutter in the drift tube could be synchronized with the laser pulse to offer additional specificity using tandem mobility separation; further, resolution was improved in mixtures of PAHs with similar mobilities. Negative ions were also detected, though these were mass-identified as ions formed from air through the capture of electrons released from the PAHs; no M-ions were observed in air. Limits of detection ranged from sub-pg to low-ng for individual PAHs.  相似文献   

10.
An empirical test is described for the evaluation of column selectivity in reversed-phase liquid chromatography. Using a test mixture of three polycyclic aromatic hydrocarbons (PAH), overall column selectivity toward PAH was assessed for over 20 different commercial C18 columns. Retention behavior was correlated to phase type (i.e., monomeric and polymeric surface modification chemistry) for custom synthesized phases. A classification scheme is proposed in which commercial C18 columns are grouped into three classes based on retention behavior: monomeric-like, polymeric-like, and intermediate phase selectivity toward PAH. Correlation of retention behavior of the test mixture with the separation of PAH mixtures and with more general column properties (e.g., phase thickness) is discussed.  相似文献   

11.
A low temperature microwave-assisted extraction method (MAE) is reported for the analysis of polycyclic aromatic hydrocarbons (PAHs) in airborne particulate matter (PM). The main parameters affecting the extraction efficiency (choice of extractants, microwave power, and extraction time) were investigated and optimized. The optimized procedure requires a 20 ml mixture of acetone:n-hexane (1:1) for extraction of PAHs in PM at 150 W of microwave energy (20 min extraction time). Clean-up of MAE extracts was not found to be necessary. The optimized method was validated using two different SRM (1648-urban particulate matter and 1649a, urban dust). The results obtained are in good agreement with certified values. PAHs recoveries for both reference materials were between 79 and 122% with relative standard deviation ranging from 3 to 21%. Detection limits were determined based on blank determination using two kinds of quartz filter substrates (n = 10), which ranged from 0.001 (0.03) ng m−3 (pg/μg) for B(k)Ft to 1.119 (37.3) for Naph in ng m−3 (pg/μg), respectively. The repeatability and day-to-day reproducibility obtained in this study were in the range of 4-16 and 3-25% for spiked standards and SRM 1649, respectively. The optimized and validated MAE technique was applied to the extraction of PAHs from a set of real world PM samples collected in Singapore. The sum of particulate-bound PAHs in outdoor PM ranged from 1.05 to 3.45 ng m−3 while that in indoor PM (cooking emissions) ranged from 27.6 to 75.7 ng m−3, respectively.  相似文献   

12.
The critical temperatures and the critical pressures of five polycyclic aromatic compounds, namely, acenaphthene, fluorene, anthracene, phenanthrene, and pyrene have been measured. All the compounds studied decompose at near-critical temperatures. A pulse-heating technique applicable to measuring the critical properties of thermally unstable compounds has been used. The times from the beginning of a heating pulse to the moment of reaching the critical temperature were from (0.06 to 0.85) ms. The short residence times provide little degradation of the substances in the course of the experiments. The experimental critical parameters of the polycyclic aromatic compounds have been compared with those estimated by five predictive methods. The acentric factors of polycyclic aromatic compounds studied have been calculated.  相似文献   

13.
气相色谱质谱法测定化妆品中9种多环芳烃   总被引:1,自引:0,他引:1  
建立了气相色谱质谱法测定化妆品中9种多环芳烃的分析方法。化妆品中的萘、苯并[a]蒽、、苯并[b]荧蒽、苯并[j]荧蒽、苯并[k]荧蒽、苯并[e]芘、苯并[a]芘、二苯并[a,h]蒽等9种多环芳烃用甲醇超声提取后,用环己烷液-液萃取后浓缩,经硅胶-中性氧化铝柱净化后,采用气相色谱-质谱测定。多环芳烃浓度在0.05~2 mg/L范围内,质量浓度与其峰面积呈良好的线性关系。在低、中、高3个添加水平下,9种多环芳烃化合物的平均回收率为81.6%~100.2%,相对标准偏差为1.3%~5.8%。方法可用于化妆品中多环芳烃的检测。  相似文献   

14.
To detect, identify, and quantify the polycyclic aromatic hydrocarbons (PAHs) released into the environment, the PAHs need to be isolated from the soil matrix. In this work, a modified quick, easy, cheap, efficient, rugged and safe (QuEChERS) method with ionic liquid was combined with liquid chromatography to identify 16 selected PAHs in soil. Ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate ([Hmim]PF6) was applied as an extractant component to enhance the process. The [Hmim]PF6 content in acetonitrile (ACN) was optimized. The [Hmim]PF6 modified QuEChERS method has the advantages defined by its name and a similar recovery to other extraction methods reported in the literature. Adding [Hmim]PF6 may eliminate the co-extract proportion and achieve a more effective extraction. Compared with ACN alone, the matrix effect (ME) of ACN containing 5% [Hmim]PF6 was reduced by approximately 35%. Additionally, the ME of using ACN containing [Hmim]PF6 without a clean-up procedure was similar to that of using ACN followed by a clean-up procedure. The recoveries of the QuEChERS method implemented with [Hmim]PF6 ranged from 75.19% to 100.98%. The limits of detection (LOD) and limits of quantification (LOQ) ranged from 0.86 to 4.51 µg/kg and from 2.87 to 15.13 µg/kg, respectively.  相似文献   

15.
Ge D  Lee HK 《Journal of chromatography. A》2011,1218(47):8490-8495
Zeolite imidazolate framework 8 (ZIF-8) has permanent porosity, high surface area, hydrophobic property, open metal sites and remarkable water stability. These novel properties characterize the material as being different from other moisture sensitive metal-organic frameworks and endow ZIF-8 with the potential to extract trace analytes from environmental water samples. In the present study, ZIF-8 was synthesized and used as a sorbent for micro-solid-phase extraction of 6 polycyclic aromatic hydrocarbons (PAHs) from environmental water samples for the first time. Parameters influencing the extraction efficiency such as desorption time, extraction time, desorption solvent and salt concentration were investigated. Environmental water samples collected from a local lake were processed using this novel μ-SPE procedure. ZIF-8 proved to be a very efficient extraction sorbent for the extraction of trace analytes from water samples. The limits of detection from gas chromatography-mass spectrometric analysis of PAHs were 0.002-0.012 ng/ml. The linear ranges were 0.1-50 or 0.5-50 ng/ml. The relative standard deviations for five replicates of the extractions were in the range of 2.1-8.5%.  相似文献   

16.
Summary Elution strengths of 11 common HPLC solvents on a polymeric C18 phase were compared using a marker set of polycyclic aromatic hydrocarbons. Naphthalene, pyrene, benzo[ghi]perylene, and three larger naphthologues of 8, 10, and 12 rings (constituting a naphthalene zigzag series) were chosen because they span the solvent strength range up to and including the strongest solvents, tetrahydrofuran (THF) and chlorobenzene. Four pairs of similarly shaped isomers were used to probe solvent selectivity. With the exception of THF, HPLC solvent strength correlated with observed red shifts of fluorescence band maxima in each solvent. For THF, the pure solvent and blended mixtures behaved quite differently.  相似文献   

17.
A simple, low-cost, and effective cooling/heating-assisted headspace solid-phase microextraction (CHA–HS–SPME) device, capable of direct cooling the fiber to low temperatures and simultaneous heating the sample matrix to high temperatures, was fabricated and evaluated. It was able to cool down the commercial and handmade fibers for the effective tapping of volatile and semi-volatile species in the headspace of complex solid matrices, with minimal manipulation compared with conventional SPME. The CHA–HS–SPME system can create large temperature gaps (up to 200 °C) between the fiber and the sample matrix, because the cooling process is directly applied onto the fiber.  相似文献   

18.
The agronomic benefit of biochar has attracted widespread attention to biochar‐based fertilizers. However, the inevitable presence of polycyclic aromatic hydrocarbons in biochar is a matter of concern because of the health and ecological risks of these compounds. The strong adsorption of polycyclic aromatic hydrocarbons to biochar complicates their analysis and extraction from biochar‐based fertilizers. In this study, we optimized and validated a method for determining the 16 priority polycyclic aromatic hydrocarbons in biochar‐based fertilizers. Results showed that accelerated solvent extraction exhibited high extraction efficiency. Based on a Box–Behnken design with a triplicate central point, accelerated solvent extraction was used under the following optimal operational conditions: extraction temperature of 78°C, extraction time of 17 min, and two static cycles. The optimized method was validated by assessing the linearity of analysis, limit of detection, limit of quantification, recovery, and application to real samples. The results showed that the 16 polycyclic aromatic hydrocarbons exhibited good linearity, with a correlation coefficient of 0.996. The limits of detection varied between 0.001 (phenanthrene) and 0.021 mg/g (benzo[ghi]perylene), and the limits of quantification varied between 0.004 (phenanthrene) and 0.069 mg/g (benzo[ghi]perylene). The relative recoveries of the 16 polycyclic aromatic hydrocarbons were 70.26–102.99%.  相似文献   

19.
An integrated screening-confirmation system for PAHs in soils is presented. The sample screening configuration comprises on-line microwave-assisted extraction of the selected pollutants, followed by continuous preconcentration and sample clean-up on RP-C18. Those samples for which the total concentration is close to or above the threshold limit established (10 microg/g) are subjected to liquid chromatographic separation for confirmation. An evaluation of the qualitative data obtained was also carried out, by calculating the unreliability zone as well as the false positive and false negative rates. The whole method (extraction/determination/confirmation) was validated using industrial soil and harbour sediment certified reference materials (IRMM, European Commission CRM 524 and CRM 535). Application to the screening of solid environmental samples with subsequent confirmation of the results is also presented.  相似文献   

20.
For the first time, Vacuum Assisted Headspace Solid Phase Microextraction (Vac-HSSPME) is used for the recovery of polycyclic aromatic hydrocarbons (PAHs) from solid matrices. The procedure was investigated both theoretically and experimentally. According to the theory, reducing the total pressure increases the vapor flux of chemicals at the soil surface, and hence improves HSSPME extraction kinetics. Vac-HSSPME sampling could be further enhanced by adding water as a modifier and creating a slurry mixture. For these soil-water mixtures, reduced pressure conditions may increase the volatilization rates of compounds with a low KH present in the aqueous phase of the slurry mixture and result in a faster HSSPME extraction process. Nevertheless, analyte desorption from soil to water may become a rate-limiting step when significant depletion of the aqueous analyte concentration takes place during Vac-HSSPME. Sand samples spiked with PAHs were used as simple solid matrices and the effect of different experimental parameters was investigated (extraction temperature, modifiers and extraction time). Vac-HSSPME sampling of dry spiked sand samples provided the first experimental evidence of the positive combined effect of reduced pressure and temperature on HSSPME. Although adding 2 mL of water as a modifier improved Vac-HSSPME, humidity decreased the amount of naphthalene extracted at equilibrium as well as impaired extraction of all analytes at elevated sampling temperatures. Within short HSSPME sampling times and under mild sampling temperatures, Vac-HSSPME yielded linear calibration curves in the range of 1–400 ng g−1 and, with the exception of fluorene, regression coefficients were found higher than 0.99. The limits of detection for spiked sand samples ranged from 0.003 to 0.233 ng g−1 and repeatability from 4.3 to 10 %. Finally, the amount of PAHs extracted from spiked soil samples was smaller compared to spiked sand samples, confirming that soil could bind target analytes more strongly and thus decrease the readily available fraction of target analytes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号