首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The preparation of an ion-selective electrode by chemical treatment of copper wire and its application for the measurements of copper (II) and iodide ions is described. The proposed reaction mechanism at the sensing surface, which explains the response of the electrode to Cu2+ and iodide ions, is discussed. The prepared electrode was suitable for direct potentiometric measurements of iodide and copper (II) in batch experiments down to concentrations of 1 × 10–5 mol L–1. A tubular electrode, prepared in the same way, may be used as a potentiometric sensor in a flow-injection analysis for Cu (II) and/or iodide determinations.  相似文献   

2.
A PVC membrane electrode for copper(II) ions based on a recently synthesized naphthol-derivative Schiff’s base as membrane carrier was prepared. The sensor exhibits a Nernstian response for Cu2+ ions over a wide concentration range (5.0 × 10–6–5.0 × 10–2 mol/L) with a detection limit of 3.1 × 10–6 mol/L (0.2 μg/mL). It has a very short response time of about 5 s and can be used for ?3 months without any divergence in potential. The proposed electrode revealed good selectivities over a wide variety of other cations including alkali, alkaline earth, transition and heavy metal ions and could be used in a pH range of 4.0–7.0. It was successfully applied to the direct determination and potentiometric titration of copper ion. Received: 23 February 1999 / Revised: 4 May 1999 / Accepted: 5 May 1999  相似文献   

3.
The construction, performance characteristics and applications of a polymeric membrance electrode for lead(II) ion are reported. The electrode was prepared by incorporating cryptand(222) as the neutral carrier into a plasticized poly(vinyl chloride) membrane. The influence of membrane composition, pH and concentration of internal reference solution were investigated. The electrode exhibits a potentiometric response for Pb2+ ion over the concentration range 10–1–10–5 M with a detection limit of 5 × 10–6 M Pb2+. It shows a relatively fast response time of about 30 s and can be used for about two months without any considerable divergence in potential. The proposed sensor revealed good selectivities for Pb2+ in the presence of several metal ions and could be used in the pH range of 2.5 to 7.5. It was used as an indicator electrode in the potentiometric titration of Pb2+ with EDTA. Received: 20 November 1998 / Revised: 26 March 1999 / Accepted: 31 March 1999  相似文献   

4.
The construction, performance characteristics and applications of a polymeric membrance electrode for lead(II) ion are reported. The electrode was prepared by incorporating cryptand(222) as the neutral carrier into a plasticized poly(vinyl chloride) membrane. The influence of membrane composition, pH and concentration of internal reference solution were investigated. The electrode exhibits a potentiometric response for Pb2+ ion over the concentration range 10–1–10–5 M with a detection limit of 5 × 10–6 M Pb2+. It shows a relatively fast response time of about 30 s and can be used for about two months without any considerable divergence in potential. The proposed sensor revealed good selectivities for Pb2+ in the presence of several metal ions and could be used in the pH range of 2.5 to 7.5. It was used as an indicator electrode in the potentiometric titration of Pb2+ with EDTA. Received: 20 November 1998 / Revised: 26 March 1999 / Accepted: 31 March 1999  相似文献   

5.
A PVC membrane containing 4-amino-6-methyl-1,2,4-triazin-3,5-dithione (AMTD) as a suitable ionophore, exhibits a Nernstian response for Cu2+ ions over a wide concentration range up to 1 × 10−1 and 1 × 10−6 M, with a detection limit of 7.5 × 10−7 M in the pH range 3.0–7.5. It has a fast response time (<15 s) and can be used for at least 12 weeks without any major deviation in the potential. The electrode revealed a very good selectivity with respect to all common alkali, alkaline-earth, transition, and heavy-metal ions. It was successfully applied to the recovery of copper ions from wastewater. The electrode was also used as an indicator electrode in the potentiometric titration of Cu(II) ions with EDTA. The text was submitted by the authors in English.  相似文献   

6.
The electrochemical behaviour of a Cu/CuSe electrode was studied in order to define its selectivity towards cupric ions, Nerstian response, limit of detection and response time. The chalcogenide electrode was prepared by cathodic deposition of Se and subsequent formation of a thin layer of CuSe on a copper substrate. A Cu/CuSe microelectrode was prepared using copper wire 75 μm in diameter. The dimensions and response time (<0.5 s) allowed use of this electrode in the “vibrating probe method” with the aim of measuring net influxes as well as effluxes of copper(II) ions in Olea europaea roots. The electrode potential was measured along the root at a distance of 5 μm from the surface for 5 s, and then again for 5 s at a distance of 55 μm, moving the microelectrode with respect to the root surface by steps with a frequency of 0.1 Hz. The potentials measured at the two extremes of vibration were then converted to copper(II) concentrations. Substitution of these values in Fick's law yields the flux, assuming the diffusion constant D for copper ions in aqueous solutions. The results enabled us to detect copper(II) fluxes as small as 0.05 pmol cm−2 s−1. Copper(II) influx showed marked spatial and temporal features: it was highest at about 1.5 mm from the root apex and exhibited an oscillatory pattern in time. Received: 29 September 1999 / Accepted: 11 January 2000  相似文献   

7.
A new carbon paste electrode modified with tetramethyl thiuram disulfide is prepared to use as copper potentiometric sensor in batch and flow analysis. The influence of pH and carbon paste composition on the potentiometric response is studied. The principal parameters of the flow system are optimized and the detection limits and the selectivity coefficients of the potentiometric sensor are calculated for static and flow mode. In both cases, the sensor shows high selectivity to copper ions but in flow analysis this selectivity is higher. The obtained detection limits are 4.6 × 10−8 M for batch measurements and 2.0 × 10−7 M for on-line analysis. The potentiometric sensor is applied to copper(II) determination in real samples in static and flow measurements. In both analysis modes, successful results are obtained.  相似文献   

8.
A newly modified electrode was prepared by mechanical immobilization of copper hexacyanoferrate (CuHCF) on a graphite electrode. The modified electrode was characterized by cyclic voltammetric experiments. The effect of different background electrolytes, pHs and scan rates on the electrochemical behaviour of the electrode has been evaluated. In NH4Cl two reversible redox peaks were observed. The first redox peak corresponding to Cu+/Cu2+ is observed only in this medium. The second redox peak corresponds to the Fe(CN)6 4–/Fe(CN)6 3– couple. Both anodic peaks were used for catalytic oxidation of ascorbic acid. As the anodic current for catalytic oxidation was proportional to the amount of ascorbic acid, an analytical method was developed for the determination of ascorbic acid in commercial samples. Received: 26 May 1998 / Revised: 15 March 1999 / Accepted: 20 March 1999  相似文献   

9.
A penicillamine (PCA) self-assembled monolayer (SAM) was prepared on a gold electrode. It has been found that the modified electrode exhibited a selective response to copper ions. As demonstrated by cyclic voltammetric experiments, the SAM-based electrode showed an attractive ability to preconcentrate efficiently traces of copper(II) from solutions. Under optimum conditions, the anodic peak current was proportional to the concentration of Cu(II) in the range from 8.0 × 10−7 to 1.0 × 10−4 M with a detection limit of 4.0 × 10−7 M. Moreover, this modified gold electrode is also characterized by excellent repeatability, showing a relative standard deviation of 3.2% for nine successive measurements of 1.0 × 10−5 M Cu(II). The PCA/Au SAM gold electrode was used for the determination of Cu(II) in a tap water sample and the results showed a good agreement with the data obtained by atomic emission spectrometry. The text was submitted by the authors in English.  相似文献   

10.
The prepared and characterized metformin ‐copper (II) complex was used as elecroactive material for modification of a new sensitive and selective modified carbon paste electrode (MCPE) for the potentiometric determination of copper (II) in water samples. The performance characteristics of MCPE were carried out. The electrode showed perfect potentiometric response for Cu (II) over concentration range of 1.0 × 10?6 – 5.0 × 10?2 mol L?1 with a detection limit of 1.0 × 10?6 mol L?1 with divalent slope value 30.8 ± 0.92 mV decade?1 over the pH range of 2–6 and exhibits fast response time of 9 s. Also, this electrode exhibited good selectivity towards Cu (II) ions with respect to other metal ions. The obtained results using the proposed electrode were in a good agreement with those obtained using the inductively coupled plasma (ICP) method.  相似文献   

11.
A pencil graphite electrode coated by copper (II)–carmoisine dye complex in polyaniline (emeraldine base form) matrix (termed as PGE/PA/Cu-Car) was prepared and used as copper ion-selective electrode. The introduced electrode was found to have high selectivity toward copper ion (II) and exhibited wide working concentration range, low response time, and good shelf life. The sensor electrode showed a linear Nernstian response over the range of 5.0 × 10−6 to 1.0 × 10−1 M with a slope of 29.7 ± 1 mV per decade change in concentration. A detection limit of 2.0 × 10−6 M was obtained. The optimum pH working range of the electrode was found to be 4.0–7.0.  相似文献   

12.
The preparation and application of an iodide ion-selective electrode, prepared by chemical treatment of a silver wire with Hg2+ is described. The electrode is suitable for the direct potentiometric measurement of iodide in aqueous solutions with concentrations down to 1 × 10–6 mol/L. It can be used for potentiometric measurements of various compounds (vitamin C, glutathione).  相似文献   

13.
A novel Schiff base designated as 5-[(3-methylthiophene-2-yl-methyleneamino)]-2-mercaptobenzimidazole was synthesized and characterized. A polyvinyl chloride-membrane potentiometric copper(II)-selective sensor was prepared by using the synthesized 5-[(3-methylthiophene-2-yl-methyleneamino)]-2-mercaptobenzimidazole compound. The prepared polyvinyl chloride-membrane copper(II)-selective sensor exhibited very good selectivity and sensitive potentiometric response towards copper(II) ions compared to a wide variety of other cations. The sensor had a fast response time of <5?s, and showed a linear Nerstian behavior to copper(II) ions over a wide concentration range from 1.0?×?10?5 to 1.0?×?10?1 mol L?1 with a slope of 29.2?±?0.7 and correlation coefficient of 0.9998. The prepared polyvinyl chloride-membrane copper(II)-selective sensor was used for 14 weeks without any significant change in its potentiometric response. The potentiometric response of the developed sensor was highly repeatable. Additionally, the developed sensor was used as an indicator electrode for the potentiometric titration of copper(II) ion with ethylenediaminetetraacetic acid. The sensor was also successfully applied to the direct determination of copper(II) ions in tap water, river water, and dam water samples.  相似文献   

14.
The results obtained in potentiometric titrations of copper(II), mercury(II) and iron(III) with standard EDTA solutions are presented. The titration of copper(II) at pH values in the range from 8.11 to 10.99 (ammonia buffer) and the titration of mercury(II) and iron(III) at pH values from 3.59 to 5.65 (acetate buffer) were performed. The titration end-point (TEP) was detected with an indicator electrode made from natural crystalline pyrite as an electrochemical sensor. The results obtained in potentiometric titration with the pyrite electrode were compared with those obtained using a platinum electrode (Fe3+), a Cu ion selective electrode (Cu2+) and a Hg electrode (Hg2+). Accurate and reproducible results with good agreement were obtained, but higher potential changes at the TEP were obtained using the pyrite electrode. In the course of the titration the potential was established within less than 1 min, whereas at the TEP it was within about 2–3 min. The potential changes at the TEP were in the range from 60 to 200 mV per 0.1 ml EDTA, according to the stability constant of the complex formed. The highest potential changes, ranging from 160 to 200 mV, were obtained in the titration of iron(III) at pH 3.59. Reverse titration was also performed and accurate and reproducible results were obtained. Moreover, titration of halogenide and thiocyanate with standard mercury(II) solutions, as well as cyanide with silver(I) solution, were performed and accurate and reproducible results were again obtained. Received: 20 February 1998 / Accepted: 19 November 1999  相似文献   

15.
Isothermal titration calorimetry (ITC) and potentiometric titration methods have been used to study the process of proton transfer in the copper(II) ion-glycylglycine reaction. The stoichiometry, conditional stability constants, and thermodynamic parameters (ΔG, ΔH, and ΔS) for the complexation reaction were determined using the ITC method. The measurements were carried out at 298.15 K in solutions with a pH of 6 and the ionic strength maintained with 100 mM NaClO4. Carrying out the measurements in buffer solutions of equal pH but different enthalpies of ionization of its components (Mes, Pipes, Cacodylate) enabled determination of the enthalpy of complex formation, independent of the enthalpy of buffer ionization. The number of protons released by glycylglycine on account of complexation of the copper(II) ions was determined from calorimetric and potentiometric measurements.  相似文献   

16.
A triiodide-selective electrode based on copper (II)-Schiff base complex as a membrane carrier is proposed. The electrode was prepared by incorporating the carrier into a plasticized polyvinylchloride (PVC) membrane and was directly coated on the surface of a graphite electrode. The obtained electrode showed a near Nernstian slope of 57.0 ± 0.4 mV/decade to I 3 ions over an activity range of 1.0 × 10−5−1.0 × 10−1 M with a limit of detection of 4.8 × 10−6 M. The response time of the electrode was fast (5 s) and the electrode could be used for about 2 months without considerable divergence in response. The potentiometric selectivity coefficients were evaluated and displayed anti-Hofmeister behavior. The electrode was used as an indicator electrode in the potentiometric titration of the triiodide ion and in the determination of ascorbic acid in vitamin C tablets. The text was submitted by the authors in English.  相似文献   

17.
A PVC membrane electrode for zinc ions based on cryptand C2B22 as membrane carrier was prepared. The electrode exhibits a linear stable response over a wide concentration range (5.0 × 10–2– 5.0 × 10–5 mol/L) with a slope of 24 mV/ decade and a limit of detection of 3.98 × 10–5 mol/L (2.6 μg/g). It has a fast response time of about 30 s and can be used for at least 4 months without any divergence in potential. The proposed sensor revealed good selectivities for Zn2+ over a wide variety of other metal ions and could be used in a pH range of 4–7. It was used as an indicator electrode in potentiometric titration of zinc ion. Received: 26 February 1998 / Revised: 25 May 1998 / Accepted: 28 May 1998  相似文献   

18.
A lead-selective solid-contact electrode was prepared on the basis of the misfit compound (PbS)1.18TiS2. The electrode exhibits the slope of the electrode function is -(26 ±1) mV/pc and provides the determination of 1 × 10-5-5 × 10-2 M lead in the pH range 2.75–5.0. High selectivity of the electrode for Ni2+, Co2+, Zn2+, Cu2+, Ag+, K+, Ba2+, and Sr2+ ions was demonstrated. The addition of graphite to the active phase of the membrane impaired the selectivity of the electrode. The electrode was used for the potentiometric indication of the titration end point in the determination of lead in copper alloys. Presented at the V All-Russian Conference with the Participation of CIS Countries on Electrochemical Methods of Analysis (EMA-99), Moscow, December 6–8, 1999.  相似文献   

19.
The possibility of the potentiometric titration of Cl and F ions directly in reversed micelles of the ethoxylated surfactant (Neonol APh9-4) in n-decane is shown. The potential change of the indicator electrode (silver chloride and lanthanum fluoride) only depends on the ion concentration in the aqueous pseudophase of the reversed micelles and is independent of the aqueous phase concentration in n-decane in the region of concentrations from 4 to 0.2 vol %. The determination of the micelle size of Neonol APh9-4 in the precipitation titration of Cl and F ions by photon correlation spectroscopy showed the formation of nanoparticles of AgCl and LaF3 of dimensions limited by original micelle size (rhd = 6 to 11 nm). The growth of AgCl and LaF3 nanoparticles was studied at a shortage and excess of the titrant and in the point of equivalence. Received: 23 April 1999 / Revised: 15 July 1999 / Accepted: 19 July 1999  相似文献   

20.
In this work, ion-selective electrodes for calcium ion were investigated. Two ionophores were used in the membranes: ETH 1001 and ETH 129. An internal filling solution buffered for primary ion was used that allowed the lower detection limit to be decreased down to 10−8.8 M. Theoretical and experimental electrode characteristics pertaining to both primary and interfering ions are discussed. Better behavior was obtained with the electrode prepared with ETH 129 in the membrane. This electrode would be the most likely candidate for obtaining a low Ca2+ detection limit in measurements performed with high K+, Na+, Mg2+ background, which is found inside the cells of living organisms, for example. The potentiometric response of the electrode in solutions containing main and interfering ions is in good agreement with simulated curves obtained using the Nernst–Planck–Poisson (NPP) model.  相似文献   