首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
In this work, a high-throughput and high-performance bioanalytical system is described that is capable of extracting and analyzing 1152 plasma samples within 10 hours. A Zymark track robot system interfaced with a Tecan Genesis liquid handler was used for simultaneous solid-phase extraction of four 96-well plates in a fully automated fashion. The extracted plasma samples were injected onto four parallel monolithic columns for separation via a four-injector autosampler. The use of monolithic columns allowed for fast and well-resolved separations at a considerably higher flow rate without generating significant column backpressure. This resulted in a total chromatographic run cycle time of 2 min on each 4.6 x 100 mm column using gradient elution. The effluent from the four columns was directed to a triple quadrupole mass spectrometer equipped with an indexed four-probe electrospray ionization source (Micromass MUX interface). Hence, sample extraction, separation, and detection were all performed in a four-channel parallel format that resulted in an overall throughput of about 30 s per sample from plasma. The performance of this system was evaluated by extracting and by analyzing twelve 96-well plates (1152) of human plasma samples spiked with oxazepam at different concentrations. The relative standard deviation (RSD) of analyte sensitivity (slope of calibration curve) across the four channels and across the 12 plates was 5.2 and 6.8%, respectively. An average extraction recovery of 77.6% with a RSD of 7.7% and an average matrix effect of 0.95 with a RSD of 5.2% were achieved using these generic extraction and separation conditions. The good separation efficiency provided by this system allowed for rapid method development of an assay quantifying the drug candidate and its close structural analog metabolite. The method was cross-validated with a conventional liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay.  相似文献   

2.
Liquid chromatography coupled to orthogonal acceleration time-of-flight mass spectrometry (LC/TOF) provides an attractive alternative to liquid chromatography coupled to triple quadrupole mass spectrometry (LC/MS/MS) in the field of multiresidue analysis. The sensitivity and selectivity of LC/TOF approach those of LC/MS/MS. TOF provides accurate mass information and a significantly higher mass resolution than quadrupole analyzers. The available mass resolution of commercial TOF instruments ranging from 10 000 to 18 000 full width at half maximum (FWHM) is not, however, sufficient to completely exclude the problem of isobaric interferences (co-elution of analyte ions with matrix compounds of very similar mass). Due to the required data storage capacity, TOF raw data is commonly centroided before being electronically stored. However, centroiding can lead to a loss of data quality. The co-elution of a low intensity analyte peak with an isobaric, high intensity matrix compound can cause problems. Some centroiding algorithms might not be capable of deconvoluting such partially merged signals, leading to incorrect centroids.Co-elution of isobaric compounds has been deliberately simulated by injecting diluted binary mixtures of isobaric model substances at various relative intensities. Depending on the mass differences between the two isobaric compounds and the resolution provided by the TOF instrument, significant deviations in exact mass measurements and signal intensities were observed. The extraction of a reconstructed ion chromatogram based on very narrow mass windows can even result in the complete loss of the analyte signal. Guidelines have been proposed to avoid such problems. The use of sub-2 microm HPLC packing materials is recommended to improve chromatographic resolution and to reduce the risk of co-elution. The width of the extraction mass windows for reconstructed ion chromatograms should be defined according to the resolution of the TOF instrument. Alternative approaches include the spiking of the sample with appropriate analyte concentrations. Furthermore, enhanced software, capable of deconvoluting partially merged mass peaks, may become available.  相似文献   

3.
There is a growing interest in exploring the use of liquid chromatography coupled with full-scan high resolution accurate mass spectrometry (LC/HRMS) in bioanalytical laboratories as an alternative to the current practice of using LC coupled with tandem mass spectrometry (LC/MS/MS). Therefore, we have investigated the theoretical and practical aspects of LC/HRMS as it relates to the quantitation of drugs in plasma, which is the most commonly used matrix in pharmacokinetics studies. In order to assess the overall selectivity of HRMS, we evaluated the potential interferences from endogenous plasma components by analyzing acetonitrile-precipitated blank human plasma extract using an LC/HRMS system under chromatographic conditions typically used for LC/MS/MS bioanalysis with the acquisition of total ion chromatograms (TICs) using 10 k and 20 k resolving power in both profile and centroid modes. From each TIC, we generated extracted ion chromatograms (EICs) of the exact masses of the [M + H](+) ions of 153 model drugs using different mass extraction windows (MEWs) and determined the number of plasma endogenous peaks detected in each EIC. Fewer endogenous peaks are detected using higher resolving power, narrower MEW, and centroid mode. A 20 k resolving power can be considered adequate for the selective determination of drugs in plasma. To achieve desired analyte EIC selectivity and simultaneously avoid missing data points in the analyte EIC peak, the MEW used should not be too wide or too narrow and should be a small fraction of the full width at half maximum (FWHM) of the profile mass peak. It is recommended that the optimum MEW be established during method development under the specified chromatographic and sample preparation conditions. In general, the optimum MEW, typically ≤ ±20 ppm for 20 k resolving power, is smaller for the profile mode when compared with the centroid mode.  相似文献   

4.
A detailed analytical study on ethephon residue determination in water, making use of ion-pairing liquid chromatography coupled to electrospray tandem mass spectrometry (LC/MS/MS), has been carried out. Ethephon is a plant growth regulator, highly polar, which is typically present in aqueous solution in anionic form due to its acid character. Both its extraction and pre-concentration from water samples and its chromatographic retention are difficult. Several approaches for sample pretreatment have been tested including direct injection into the chromatographic system, on-line solid phase extraction (SPE) and off-line SPE, with the best results being obtained after off-line SPE, using Oasis MAX cartridges (mixed-mode strong anion-exchange). After testing several ion-pairing reagents, tetrabuthylammonium acetate (TBA) was selected. This was added to the samples before LC/MS/MS analysis to facilitate ethephon chromatographic retention. The acquisition of several specific MS/MS transitions together with the evaluation of their relative intensity ratios allowed the reliable confirmation of the analyte in samples. The optimised approach was tested in low-salinity water spiked at 0.1?µg?L?1 level with satisfactory recovery, and a limit of detection of 0.02?µg?L?1. To this purpose, the water sample was partially de-ionised in an initial stage, in order to remove major ions that would have interfered in analyses. The application of this methodology to more saline/complex water samples, as surface or wastewater, was problematic and a thorough optimisation of the de-ionisation conditions would be required.  相似文献   

5.
A method with parallel extraction columns and parallel analytical columns (PEC-PAC) for on-line high-flow liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed and validated for simultaneous quantification of a drug candidate and its six metabolites in dog plasma. Two on-line extraction columns were used in parallel for sample extraction and two analytical columns were used in parallel for separation and analysis. The plasma samples, after addition of an internal standard solution, were directly injected onto the PEC-PAC system for purification and analysis. This method allowed the use of one of the extraction columns for analyte purification while the other was being equilibrated. Similarly, one of the analytical columns was employed to separate the analytes while the other was undergoing equilibration. Therefore, the time needed for re-conditioning both extraction and analytical columns was not added to the total analysis time, which resulted in a shorter run time and higher throughput. Moreover, the on-line column extraction LC/MS/MS method made it possible to extract and analyze all seven analytes simultaneously with good precision and accuracy despite their chemical class diversity that included primary, secondary and tertiary amines, an alcohol, an aldehyde and a carboxylic acid. The method was validated with the standard curve ranging from 5.00 to 5000 ng/mL. The intra- and inter-day precision was no more than 8% CV and the assay accuracy was between 95 and 107%.  相似文献   

6.
The applicability of in-vial two-phase liquid-phase microextraction (LPME) in porous hollow polypropylene fiber was studied for the sample preparation of unconjugated anabolic steroids in urine. Four different anabolic steroids - metabolites of fluoxymesterone, 4-chlorodehydromethyltestosterone, stanozolol and danazol - were used as test compounds and methyltestosterone as an internal standard. A standard two-phase LPME method for use with liquid chromatography/mass spectrometry (LC/MS) was set up and the influence of different parameters, including the nature of organic solvent, extraction time, salting-out and temperature, on the LPME process was investigated. Taking advantage of the preliminary studies, a novel two-phase LPME method utilizing simultaneous in-fiber silylation was developed and validated for gas chromatographic/mass spectrometric (GC/MS) analysis of a danazol metabolite in urine. In all, LPME allowed a very straightforward, simple and selective way to prepare urine samples for steroid analysis, being most suitable for hydrophobic steroids. The LPME method with in-fiber derivatization for GC/MS analysis exhibited high sensitivity, repeatability and linearity and enabled simultaneous filtration, extraction, enrichment and derivatization of the analyte from urine matrix without any other steps in sample pretreatment.  相似文献   

7.
As a continuation of our efforts to improve our high-flow on-line bioanalytical approach for high-throughput quantitation of drugs and metabolites in biological matrices by high-performance liquid chromatography (LC) and tandem mass spectrometry (MS/MS), we have developed a ternary-column on-line LC/MS/MS system with dual extraction columns used in parallel for purification and an analytical column for analysis. The advantage of the dual extraction column system is that sample analysis can take place in one of the extraction columns while the other column is being equilibrated. Thus, the equilibration time does not add to the run time, hence shortening the injection cycle time and increasing the sample throughput. Moreover, the use of two extraction columns in parallel increases the number of samples that can be injected before the system fails due to an overused extraction column. Such a system has successfully been used to develop and validate a positive ion electrospray LC/MS/MS bioanalytical method for the quantitative determination of a guanidine-containing drug candidate in rat plasma. The system used for this work utilized two Oasis HLB extraction columns (1 x 50 mm, 30 microm), one C18 analytical column (3.9 x 50 mm, 5 microm), a ten-port switching value and a tandem mass spectrometer. The on-line analysis was accomplished by the direct injection of 10 microL of the sample, obtained by mixing a rat plasma sample 1:1 with an aqueous internal standard solution. Selected reaction monitoring (SRM) was utilized for the detection of the analyte and internal standard. The standard curve range was 1.00-200 ng/mL. The intra- and inter-day precision and accuracy were within 6.6%. The on-line purification step lasted for only 0.3 min and total run time was only 1.6 min.  相似文献   

8.
A simple and specific method using reversed‐phase liquid chromatography coupled with electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) was investigated, which allowed the determination of residues of glyphosate and its metabolite, aminomethylphosphonic acid (AMPA), in soybean samples. An aqueous extraction with liquid‐liquid partition followed by protein precipitation was performed before the LC/MS/MS determination. The quantitation of glyphosate and AMPA was performed in positive and negative ESI mode, respectively, using the multiple reaction monitoring (MRM) mode with three transitions for each analyte to enhance the specificity of the method and avoid false positives. The methodology reported in this work is capable of detecting residues of glyphosate and AMPA in soybean samples with limits of quantification of 0.30 and 0.34 mg kg?1, respectively. This alternative method has throughput advantages such as simpler sample preparation and faster chromatographic analysis. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
A rapid screening method for pesticides has been developed to promote more efficient processing of produce entering the United States. Foam swabs were used to recover a multiclass mixture of 132 pesticides from the surfaces of grapes, apples, and oranges. The swabs were analyzed using direct analysis in real time (DART) ionization coupled with a high‐resolution Exactive Orbitrap? mass spectrometer. By using a DART helium temperature gradient from 100–350°C over 3 min, a minimal separation of analytes based on volatility differences was achieved. This, combined with the Exactive's mass resolution of 100 000, allowed the chromatographic step, along with the typical compositing and extraction steps associated with gas chromatography/mass spectrometry (GC/MS) or liquid chromatography/mass spectrometry (LC/MS) approaches, to be eliminated. Detection of 86% of the analytes present was consistently achieved at levels of 2 ng/g (per each apple or orange) and 10 ng/g (per grape). A resolution study was conducted with four pairs of isobaric compounds analyzed at a mass resolution of 100 000. Baseline separation was achieved with analyte ions differing in mass by 25 ppm and analyte ions with a mass difference of 10 ppm were partially resolved. In addition, field samples that had undergone traditional sample preparation using QuEChERS (quick, easy, cheap, rugged, and safe) were analyzed using both LC/MS and DART‐MS and the results from the two techniques were found to be comparable in terms of identification of the pesticides present. The use of swabs greatly increased sample throughput by reducing sample preparation and analysis time. Published in 2010 by John Wiley & Sons, Ltd.  相似文献   

10.
The applicability of ultra-performance liquid chromatography (UPLC) combined with full-scan accurate mass time-of-flight (TOF) and Orbitrap mass spectrometry (MS) to the analysis of hormone and veterinary drug residues was evaluated. Extracts from blank bovine hair were fortified with 14 steroid esters. UPLC-Orbitrap MS performed at a resolving power of 60,000 (FWHM) enabled the detection and accurate mass measurement (<3 ppm error) of all 14 steroid esters at low ng/g concentration level, despite the complex matrix background. A 5 ppm mass tolerance window proved to be essential to generate highly selective reconstructed ion chromatograms (RICs) having reduced background from the hair matrix. UPLC-Orbitrap MS at a lower resolving power of 7500 and UPLC-TOFMS at mass resolving power 10,000 failed both to detect all of the steroid esters in hair extracts owing to the inability to mass resolve analyte ions from co-eluting isobaric matrix compounds. In a second application, animal feed extracts were fortified with coccidiostats drugs at levels ranging from 240 to 1900 ng/g. UPLC-Orbitrap MS conducted at a resolving power of 7500 and 60,000 and UPLC-TOFMS detected all of the analytes at the lowest investigated level. Thanks to the higher analyte-to-matrix background ratio, the utilization of very narrow mass tolerance windows in the RIC was not required. This study demonstrates that even when the targeted sample preparation from conventional LC-MS/MS is applied to UPLC with full-scan accurate mass MS, false compliant (false negative) results can be obtained when the mass resolving power of the MS is insufficient to separate analyte ions from isobaric co-eluting sample matrix ions. The current trend towards more generic and less selective sample preparation is expected to aggravate this issue further.  相似文献   

11.
A rapid, sensitive and selective method has been developed for the direct determination of ethephon residues in vegetables (apple, cherry and tomato). Given the anionic character of ethephon, the use of ion-pairing liquid chromatography (LC) in combination with tandem mass spectrometry (MS/MS, triple quadrupole) allowed its direct determination in these matrices avoiding a derivatisation step and favouring the automation of the method. Samples were extracted with a mixture of dichloromethane/aqueous formic acid (pH 3) (1:1). Then, tetrabutylammonium acetate (TBA) was added as an ion-pairing reagent, and an aliquot of the aqueous extract was directly injected into the LC/MS/MS system. Quantification was performed with matrix-matched standards prepared from blank sample extracts. MS/MS measurements were made in the selected reaction monitoring (SRM) mode, using the most sensitive transition (m/z 107 > 79) for quantification, and up to four additional transitions for confirmation. Quantitative recoveries were obtained for all matrices (between 83% and 96%) at two concentration levels tested (0.05 and 0.5 mg/kg), with relative standard deviations lower than 9% in all cases. The addition of TBA directly into the sample extract contained in the injection vial was found sufficient to obtain satisfactory LC retention for the analyte. Under these conditions, the absence of ion-pairing reagent in the mobile phase minimised the ionisation suppression for ethephon in the MS source, leading to an increase in the sensitivity of the method and reaching limits of detection of 0.02 mg/kg for all matrices investigated. The acquisition of five specific MS/MS transitions for ethephon allowed the simultaneous and reliable quantification and confirmation of the analyte in the samples.  相似文献   

12.
A control sample background-subtraction algorithm was developed for thorough subtraction of background and matrix-related signals in high-resolution, accurate mass liquid chromatography/mass spectrometry (LC/MS) data to reveal ions of interest in an analyte sample. This algorithm checked all ions in the control scans within a specified time window around the analyte scan for potential subtraction of ions found in that analyte scan. Applying this method, chromatographic fluctuations between runs were dealt with and background and matrix-related signals in the sample could be thoroughly subtracted. The effectiveness of this algorithm was demonstrated using four test compounds, clozapine, diclofenac, imipramine, and tacrine, to reveal glutathione (GSH)-trapped reactive metabolites after incubation with human liver microsomes supplemented with GSH (30 microM compound, 45-min incubation). Using this algorithm with a +/- 1.0 min control scan time window, a +/- 5 ppm mass error tolerance, and appropriate control samples, the GSH-trapped metabolites were revealed as the major peaks in the processed LC/MS profiles. Such profiles allowed for comprehensive and reliable identification of these metabolites without the need for any presumptions regarding their behavior or properties with respect to mass spectrometric detection. The algorithm was shown to provide superior results when compared to several commercially available background-subtraction algorithms. Many of the metabolites detected were doubly charged species which would be difficult to detect with traditional GSH adduct screening techniques, and thus, some of the adducts have not previously been reported in the literature. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   

13.
A two-dimensional capillary array liquid chromatography system coupled with matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) was developed for high-throughput comprehensive proteomic analysis, in which one strong cation-exchange (SCX) capillary chromatographic column was used as the first separation dimension and 10 parallel reversed-phase liquid chromatographic (RPLC) capillary columns were used as the second separation dimension. A novel multi-channel interface was designed and fabricated for on-line coupling of the SCX to RPLC column array system. Besides the high resolution based on the combination of SCX and RPLC separation, the developed new system provided the most rapid two-dimensional liquid chromatography (2D-LC) separation. Ten three-way micro-splitter valves used as stop-and-flow switches in transferring SCX fractions onto RPLC columns. In addition, the three-way valves also acted as mixing chambers of RPLC effluent with matrix. The system enables on-line mixing of the LC array effluents with matrix solution during the elution and directly depositing the analyte/matrix mixtures on MALDI plates from the tenplexed channels in parallel through an array of capillary tips. With the novel system, thousands of peptides were well separated and deposited on MALDI plates only in 150min for a complex proteome sample. Compared with common 2D-LC system, the parallel 2D-LC system showed about 10-times faster analytical procedure. In combination with a high throughput tandem time of flight mass spectrometry, the system was proven to be very effective for proteome analysis by analyzing a complicated sample, soluble proteins extracted from a liver cancer tissue, in which over 1202 proteins were identified.  相似文献   

14.
In this work, an on-line four-column high-flow parallel extraction device was set up and interfaced to a four-column parallel separation system with a four-sprayer tandem mass spectrometric detector. This system allowed for the direct and simultaneous sampling, extraction, separation, and detection of four samples in biological fluids, resulting in significantly increased throughput. The performance of this system was evaluated using rat plasma samples spiked with methotrexate as a test compound. The results showed that the relative standard deviation for responses across the four parallel channels was less than 10% for a concentration range from 10 to 2500 nM, resulting in comparable sensitivity (slope of curve) for the analyte on all channels. A ruggedness test was performed using a mixed set of new and used extraction columns and the relative standard deviation in analyte response was found to be below 15%. The inter-channel crosstalk was measured to be about 0.1%. A comparison between the data generated on this system and on a conventional system for a rat pharmacokinetic study showed no more than 20% difference in measured concentrations. This parallel system is a viable tool for high-throughput bioanalysis in a drug discovery environment.  相似文献   

15.
In order to increase the sensitivity of liquid chromatography/mass spectrometry (LC/MS) assays of recombinant proteins for pharmacokinetics studies, we have developed an immuno-mass spectrometry assay for EPI-hNE4, a 6237 Da protein currently developed for respiratory distress syndromes. After immunocapture of the analyte in human plasma with magnetic beads coated with anti-EPI-hNE4 antibodies, the intact protein was eluted and separated in reversed-phase LC and then analysed by tandem mass spectrometry (MS/MS) in selected reaction monitoring (SRM) mode. The problem of analytical interference due to endogenous binding antibodies was addressed by successive steps of acidification and neutralisation before immunocapture. Furthermore, potential variations in the recovery of analyte during sample extraction were compensated for by addition of an internal standard recognised by the antibodies. The precision of the assay remained therefore below 15%. A significant increase in assay sensitivity was achieved since the extraction step allowed sample concentration and removal of matrix components interfering with the electrospray ionisation process. Using 0.4 mL of plasma, a limit of quantification at 0.5 ng/mL (80 pM) was reached, which represents a 10-fold improvement in sensitivity over our previous work using sample precipitation. This technique was able to monitor EPI-hNE4 kinetics in the plasma of human subjects for 36 h after an intravenous administration of 0.125 mg/kg.  相似文献   

16.
A method is described for the determination of melanotan-II (MT-II), a synthetic cyclic heptapeptide analog of alpha-melanocyte-stimulating hormone (alpha-MSH), in rat plasma by liquid chromatography/tandem mass spectrometry (LC/MS/MS). The analyte is recovered from plasma by solid-phase extraction (SPE) and subsequently analyzed by LC/MS/MS. A SPE procedure using OASIS 96-well plates is used for extraction of MT-II from rat plasma. Using the described approach a limit of quantitation of 5 ng/mL was achieved in rat plasma. This level of sensitivity allowed the determination of pharmacokinetic parameters, following intravenous administration of MT-II in rat.  相似文献   

17.
The applicability of liquid chromatography–mass spectrometry (LC/MS) is often limited by throughput. The sharing of a mass spectrometer with multiple LCs significantly improves throughput; however, the reported systems have not been designed to fully utilize the MS duty cycle, and as a result to achieve maximum throughput. To fully utilize the mass spectrometer, the number of LC units that a MS will need to recruit is application dependent and could be significantly larger than the current commercial or published implementations. For the example of a single analyte, the number may approach the peak capacity to a first degree approximation. Here, the construction of a MS system that flexibly recruits any number of LC units demanded by the application is discussed, followed by the method to port a previously developed LC/MS method to the system to fully utilize a mass spectrometer. To demonstrate the performance and operation, a prototypical MS system of eight LC units was constructed. When 1‐min chromatographic separations were performed in parallel on the eight LCs of the system, the average LC/MS analysis time per sample was 10.5 s when applied to the analysis of samples in 384‐well plate format. This system has been successfully used to conduct large‐volume biochemical assays with the analysis of a variety of molecular entities in support of drug discovery efforts. Allowing the recruitment of the number of LC units appropriate for a given application, this system has the potential to be a plug‐and‐play system to fully utilize a mass spectrometer. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

18.
To meet the increasing clinical needs for 25‐hydroxyvitamin D3 (25OH‐D3) detection, the development of an efficient and accurate high‐performance liquid chromatography–mass spectrometry (HPLC–MS) method for plasma 25OH‐D3 quantitation is important. Since 25OH‐D3 is an endogenous compound, the lack of a plasma blank increases the difficulty of accurately quantifying 25OH‐D3. Selection of a method suitable for clinical monitoring among various methods for endogenous compound quantification is necessary. Methyl tert butyl ether was chosen for the sample treatment in a liquid–liquid extraction protocol. Water as a blank matrix, 5% human serum albumin in water as a blank matrix, surrogate analyte and background subtraction were designed to address the problem of a deficiency of a plasma blank. Four liquid chromatography–tandem mass spectrometry methods were fully validated to verify the advantages and limitations owing to regulatory deficiencies for endogenous compound validation. All four methods met the criteria and could be used to monitor clinical samples. Overall 30 human plasma samples were quantified in parallel using the four methods. The difference between any two methods was <12.6% and the total relative standard deviation was <5.2%. Background subtraction and 5% human serum albumin in water as a blank matrix may be better choices considering data quality, matrix similarity, cost and practicality.  相似文献   

19.
A simple plasma extraction method coupled with liquid chromatography–tandem mass spectrometry (LC/MS/MS) detection was developed and validated for the analysis of endogenous mevalonic acid (MVA), a biomarker indicative of the rate of cholesterol biosynthesis, in human plasma samples. The analyte was extracted from the plasma matrix using a straightforward liquid–liquid sample preparation procedure. The extract supernatants were evaporated, reconstituted in aqueous solvent and injected into the LC/MS/MS system without further processing. The chromatographic separation was achieved on a reverse‐phase high‐performance liquid chromatography column. The accuracy and precision of the method was determined over the concentration range 0.25–25 ng/mL MVA from human plasma extracts in three validation batch runs. Inter‐assay precision (%CV) and accuracy (%RE) of the quality control samples were ≤7.00% (at lower limit quality control) and ≤6.10%, respectively. The sensitivity and throughput of this assay was significantly improved relative to previously published methods, resulting in smaller sample requirements and shorter analysis time. Assay results from a clinical study following the oral administration of an exploratory statin demonstrate that this procedure could potentially be used in the investigation of therapies associated with hypercholesterolemia. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

20.
Zhou  Jing  Zhang  Yingxue  Xu  Baiqiu  Zhang  Xu  Cui  Shufen 《Chromatographia》2014,77(17):1213-1221

In this study, a liquid-phase solvent bar micro-extraction technique was used to investigate both the extraction and back-extraction processes of the target analyte. A novel concentration curve method and a classic time curve method, used under the same experimental conditions, verified the symmetry between the extraction process (target analyte moves from sample matrix to the organic solvent-based extraction phase) and the back-extraction process (target analyte moves from organic solvent to the sample matrix), providing the basis to use the target analyte in the back-extraction process to calibrate its extraction process. A quantitative calibration can be achieved using back extraction on the target analyte from the blank sample matrix in the organic solvent. Information from the process of back extraction of the target analyte, such as the time constant a, can be directly used to calculate the initial concentration of the target analyte in the sample matrix. This new kinetic calibration method employs a liquid-phase solvent bar micro-extraction technique combined with high-performance liquid chromatography with a diode array detector (HPLC-DAD) and was successfully used to analyze three local anesthetics in biological samples; it extends the application of the kinetic calibration to HPLC-DAD and establishes a novel, simple and accurate method to determine the concentration of the free drug in biological samples and its protein-binding ratio.

  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号