首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到12条相似文献,搜索用时 0 毫秒
1.
A new pyrolysis–GC/MS system incorporating with on-line micro-ultraviolet (UV) irradiation was developed to make rapid evaluation of the synergistic material deterioration during UV irradiation under thermal and oxidative atmospheres. The basic effectiveness of the system was demonstrated by polystyrene, polypropylene and polycarbonate as the test samples. The volatile products evolved during deterioration of the polymers were analyzed on-line by thermal desorption GC/MS, and then the residual degraded polymers were analyzed by evolved gas analysis (EGA) and/or Py–GC/MS to obtain specific thermograms and pyrograms. Based on these results, the deterioration mechanism of the polymeric materials during irradiation under thermal and oxidative atmosphere can be evaluated using a sub-milligram polymer sample within a relatively short period of time.  相似文献   

2.
A pyrolysis-GC/MS system incorporating with micro-UV irradiator (Xe-Hg lamp) was applied to the evaluation of the weatherability of the acrylic coating paints for house exterior walls. The deterioration of the materials during UV irradiation under thermal, and oxidative atmosphere was evaluated within a relatively short period of time with evolved gas analysis-mass spectrometry (EGA-MS) using a sub-milligram polymer sample. The EGA-MS thermograms indicated that both micro-UV irradiator with Xe-Hg lamp and weather meter with metal halide lamp caused similar photo, thermal, and oxidative degradation to the coating paint samples. Strong correlations between the results obtained by the UV/Py-GC/MS and that obtained by conventional weathering test using metal halide lamp was observed. It was suggested that UV/Py-GC/MS method could be used for compensating the conventional method by reducing the test period.  相似文献   

3.
The high cost and long duration of the existing standard tests, such as ASTM D5338 and ISO 14855, represents an important drawback in evaluating the biodegradability of polymers. This works presents a new accelerated method for this purpose, based on the use of a Bartha respirometer and biostimulation with yeast extract. The new method was applied to microcrystalline cellulose (MCC), low density polyethylene (LDPE), poly(3-hidroxybutyrate) (PHB), poly(lactic acid) (PLA), poly(vinyl alcohol) (PVOH), polypropylene (PP) and poly(ethylene terephthalate) (PET). The results obtained with these polymers were consistent with those of the standard methods in terms of differentiating biodegradable and non-biodegradable polymers and relative order of biodegradation extent. Besides, a significant reduction of test duration was achieved (from 45 to 110 days with ASTM D5338 or ISO 14855 to 28 days). These results corroborate the potential of the proposed method as a fast test for assessment of biodegradation of polymeric materials.  相似文献   

4.
An advance on the model used by Guseva et al. [1] for estimating the service life of organic coatings under service conditions from accelerated test results has been developed. Instead of modelling just the times to failure, this new approach uses the complete degradation curve and allows for a more general specification of the failure time distribution. This modified model was then applied to the estimation of the service life (defined as gloss loss) for aircraft coatings and the results were compared to those obtained by Guseva et al. It was found that when this model was applied to the naturally weathered data, gloss loss (and thus failure times at a given level of gloss loss) followed a generalised gamma distribution, rather than the Weibull distribution identified by Guseva et al. Further, the new approach suggested a reduction in the warranty time of about one month. When the model was applied to the accelerated test data, it produced more accurate extrapolations of the median failure time associated with the naturally weathered data - (49.3 months compared to a measured 52 months obtained at the naturally weathered site). In fact, the extrapolated distribution obtained by this new approach was much closer to the distribution for the naturally weathered data than the extrapolated distribution obtained by Guseva et al.  相似文献   

5.
Chemiluminescence (CL) has been applied as a condition monitoring technique to assess aging related changes in a hydroxyl-terminated-polybutadiene based polyurethane elastomer. Initial thermal aging of this polymer was conducted between 110 and 50 °C. Two CL methods were applied to examine the degradative changes that had occurred in these aged samples: isothermal “wear-out” experiments under oxygen yielding initial CL intensity and “wear-out” time data, and temperature ramp experiments under inert conditions as a measure of previously accumulated hydroperoxides or other reactive species. The sensitivities of these CL features to prior aging exposure of the polymer were evaluated on the basis of qualifying this method as a quick screening technique for quantification of degradation levels. Both the techniques yielded data representing the aging trends in this material via correlation with mechanical property changes. Initial CL rates from the isothermal experiments are the most sensitive and suitable approach for documenting material changes during the early part of thermal aging.  相似文献   

6.
Thermal treatment hyphenated with gas chromatography is a versatile and powerful tool in the study of polymer characterization. An inexpensive system where thermal treatment at different temperatures occurs inside a Programmable Temperature Vaporization injector (PTV) is described. The samples investigated, commercial plastics, are complex mixtures that contain several polymers and additives. These plastics as well as their pure constituents are subjected to multi-step thermal treatment. The individual chromatograms of the various constituents of the polymeric sample are correlated with those of the final material in order to identify additives (thermal desorption) and degradation products (pyrolysis). Results obtained with the new method indicate the interesting potentials of the technique for the characterization of polymer compositions. Reproducibility of absolute and relative peak areas has been considered and found to be acceptable. The absence of a heated transfer line and switching valves, which are always present in conventional set-ups, eliminates the risk of losses of high molecular weight components. Further advantages of the technique proposed are simplicity, versatility, and its inexpensive nature.  相似文献   

7.
研制了一种新型的多路气体自动进样器,可与气相色谱联机,用于钢瓶中气体组分的定性、定量分析,最多可同时分析16个钢瓶气体样品。通过对色谱工作站参数的设定,可自动调整钢瓶气体的进样顺序、进样次数和进样时间。实验表明,与手动进样方式相比,气体自动进样器的应用可显著提高色谱分析的重复性、稳定性,以及气体分析的工作效率和分析精确度。  相似文献   

8.
Roflumilast is a phosphodiesterase type 4 inhibitor that is administered orally as a long-term, in the clinical treatment of chronic obstructive pulmonary disease and asthma. Launched in 2010 for the European market, it currently does not have an official monograph. Here, a reproducible gradient RP-HPLC method was developed and validated for the separation and determination of Roflumilast in the presence of its six major degradation products. Separation was performed on a C18 analytical column (250?×?4.6?mm, 5?µm) with a mobile phase-A of ACN and a phase-B of ammonium acetate buffer (5?mM, pH 4.2) containing triethylamine (0.5% v/v). The most effective RP-HPLC gradient program was determined to be 0/80, 35/10, 36/80, 40/80 (time in minutes/% mobile phase-B). The flow rate was 1.0?ml/min and the column temperature was 25°C. The success of separation of the degradation products with different chemical characteristics was obtained by extending the time of the gradient, changing the proportion of the mobile phases and increasing the velocity of the flow. Two detectors were evaluated for the identification of degradation products and Roflumilast: a diode-arrary detector and a charged aerosol detector. The inability of the charged aerosol detector to dectect one of the six degradation products indicated that the method developed with RP-HPLC and the diode-array detector was more suitable for Roflumilast analysis. The method was validated according to specificity, linearity, LOD, LOQ, accuracy, precision and robustness.  相似文献   

9.
In this study, a multiresidue analytical method for the detection of 37 pesticides in a soil matrix was developed and validated. The soil sample was fortified with a known quantity of pesticides at two different concentration levels (0.1 and 0.01 µg/g) and the analytes were extracted via a liquid–solid extraction method. The pesticides were separated on an HP5 capillary column and were analyzed with a gas chromatograph coupled to a nitrogen–phosphorous detector (GC‐NPD). Method validation was accomplished with good linearity (r2 = 0.994–0.999) within a considerable range of concentrations. Satisfactory recoveries (70.5–110.4%) were obtained with 32 pesticides at both spiking concentration levels, whereas five pesticides—dimepiperate, buprofezin, prometryn, pirimicarb, and fludioxonil—were recovered at relatively low levels (43.6–61.8%). The applicability of the method was demonstrated by analyzing field samples collected from 24 different sites around Yeongsan and Sumjin rivers in the Republic of Korea. No residues of the selected pesticides were detected in any of the samples. The developed method could be employed as a simple and cost‐effective method for the routine detection and analysis of 37 pesticides in soil samples. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

10.
A simple high‐performance liquid chromatographic (HPLC) method with photometric detection is described for the determination of vardenafil hydrochloride, a phosphodiesterase V inhibitor, in human plasma. Chromatographic separation of the analyte and internal standard was achieved on an analytical 250 × 4.6 mm i.d. reversed‐phase Kromasil KR 100 C18 (5 µm particle size) column using a mobile phase of acetonitrile–potassium dihydrogen phosphate (30:70 v/v). The run time was less than 15 min. Column eluate was monitored at 230 nm. The linearity over the concentration range of 10–1500 ng/mL for vardenafil was obtained and the limit of quantification (LOQ) was 10 ng/mL. The method has been applied to analysis of the vardenafil concentrations for application in pharmacokinetic studies. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
 根据 30万t乙烯工程“橡胶”装置中生产工艺控制的实际需要 ,研究了在线分析己烷中痕量四氢呋喃的气相色谱柱系统。使用自制的 7μm特厚膜甲基硅氧烷大孔径弹性石英毛细管柱 ,通过试验不同条件下色谱柱的分离特性及研究组分在柱内的运动轨迹 ,给出了总的柱切换时间程序。在上述基础上 ,完成了正己烷、环己烷中 10 -6(体积分数 )级的四氢呋喃分析。现场应用一年多的实践表明 ,所研制的柱系统从分析时间、运行稳定性、定量准确性 (相对标准偏差小于 5 % )等方面均满足工艺控制的要求。  相似文献   

12.
An analytical method based on a dual capillary gas chromatographic technique combining the advantages of GasPro PLOT and a non polar narrow bore WCOT column was developed for the analysis of air samples containing C2–C9 NMHCs. A refocusing step was not required due to the fast heating rate of the sample preconcentration trap and the resolving power of the PLOT column for C2 and C3 NMHCs. Water had to be removed from the air samples to avoid plugging of the columns if the initial GC oven temperature was below ambient temperature. To dry air samples, a scrubber and a cryogenic technique were employed. The interferences caused by carbon dioxide were reduced by purging the loaded sample preconcentration trap with helium. The dual column system was compared to a method employing a refocusing device and a single narrow bore WCOT column. Both systems provided a high degree of precision. However, the dual column approach was superior to the single column system due to better resolution of low molecular weight components.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号