首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
Enantioseparation of N-tert.-butyloxycarbonyl amino acids (N-t-Boc-Aas) with teicoplanin chiral selector was performed in two different separation systems: A teicoplanin-based chiral stationary phase (CSP-TE) was used in reversed-phase HPLC, and the same chiral selector (CS) was added into a background electrolyte (BGE) in HPCE. The enantioselective interaction with the same CSP/CS can be influenced by several factors, such as mobile phase/background electrolyte composition: the buffer concentration, pH, the CS concentration, the presence of organic modifiers. In addition, the charge of the chiral selector related to the charge of the analyte and to EOF are important variables in CE. The effect of these parameters on enantioselectivity and enantioseparation of selected N-t-Boc-Aas was studied. The presence of a sufficient concentration (1% solution) of a triethylamine acetate buffer in the mobile phase was shown to be essential for enantioseparation of these blocked amino acids in HPLC. A certain concentration of teicoplanin aggregates (along with teicoplanin molecules) in the BGE is required to obtain enantioseparation of N-t-Boc-Aas in HPCE.  相似文献   

2.
This study details the use of two permanently positively charged mono-substituted β-cyclodextrin derivatives, 6I -deoxy-6I-(N,N N′,N′,Nt’-pentamethyl-ethylene-1,2-diammonio)-cyclomaltoheptose dichloride (PEMEDA-β-CD) and the newly synthesised 6I-deoxy-6I-(N,N,N′,N′,N′-pentamethyl-propylene-1,3-diammonio)-cyclomaltoheptose (PEMPDA-β-CD) as chiral selectors in capillary electrophoresis. Cyclodextrin (CD) derivatives were tested as additives in various buffers at various pH values with the optional addition of an organic modifier. Fourteen anionogenic analytes were tested, including native amino acids, N-blocked amino acids and profens, which were detected using a UV-VIS detector at optimal wavelengths of 214 nm, 254 nm or 280 nm. A borate buffer (15 mmol L?1) at pH 9.5 without the addition of an organic modifier was chosen as a suitable background electrolyte. In addition, the effect of the concentration of the chiral selector on the separation and enantioseparation of selected analytes was monitored. The additions of cyclodextrin derivatives varied within the concentration range of 0.0–5.0 mmol L?1. Both chiral selectors were suitable for the enantioseparation of N-Boc-d,l-tryptophan, which was already separated on the baseline at 0.5 mmol L?1 concentration of the chiral selector.  相似文献   

3.
In this study, a new CE method, employing a binary system of trimethyl‐β‐CD (TM‐β‐CD) and a chiral amino acid ester‐based ionic liquid (AAIL), was developed for the chiral separation of seven 2‐arylpropionic acid nonsteroidal anti‐inflammatory drugs (NSAIDs). In particular, the enantioseparation of ibuprofen, ketoprofen, carprofen, indoprofen, flurbiprofen, naproxen, and fenoprofen was improved significantly by supporting the BGE with the chiral AAIL l ‐alanine tert butyl ester lactate (l ‐AlaC4Lac). Parameters, such as concentrations of TM‐β‐CD and l ‐AlaC4Lac, and buffer pH, were systematically examined in order to optimize the chiral separation of each NSAID. It was observed that the addition of the AAIL into the BGE improved both resolution and efficiency significantly. After optimization of separation conditions, baseline separation (Rs>1.5) of five of the analytes was achieved in less than 11 min, while the resolution of ibuprofen and flurbiprofen was approximately 1.2. The optimized enantioseparation conditions for all analytes involve a BGE of 5 mM sodium acetate/acetic acid (pH 5.0), an applied voltage of 30 kV, and a temperature of 20°C. In addition, the results obtained by computing the %‐RSD values of the EOF and the two enantiomer peaks, demonstrated excellent run‐to‐run, batch‐to‐batch, and day‐to‐day reproducibilities.  相似文献   

4.
《Analytical letters》2012,45(15):2821-2839
Abstract

The macrocyclic antibiotics represent a relatively new class of chiral selectors in separation science and teicoplanin‐based chiral stationary phases (CSP) have been used successfully in a number of applications in high‐performance liquid chromatography. In the present studies, we self‐prepared two bonded CSPs–teicoplanin (TE) and teicoplanin phenyl isocyanate (TE‐Phe). Seven amino alcohols, propranolol, bisoprolol fumarate, atenolol, salbutamol, isoproterenol, metoprolol, and labetalol were enantioseparated on both self‐made CSPs using methanol as mobile phase and acetic acid (HOAc) and triethylamine (TEA) as mobile phase additives. On both CSPs, the different enantioseparation behavior of analytes with different structure was compared. The influence of the concentration of mobile phase additives (HOAc and TEA) on the enantioseparation was investigated. In all conditions, the retention factors (k′) of seven analytes on TE‐Phe CSP were larger than that on TE CSP. However, the separation factors (α) and resolutions (Rs) on TE‐Phe CSP were smaller than that on TE CSP. The results indicated that the derivatized TE‐Phe CSP is not efficient as original teicoplanin CSP. Our observations also suggested that, for teicoplanin‐based CSPs, π‐π interactions and dipole‐dipole between solutes and CSPs mainly contribute to the retention of solutes on CSPs while hydrogen bonding and steric interactions play important roles in the chiral recognition for teicoplanin‐based CSPs.  相似文献   

5.
The enantiomeric separations of highly hydrophobic furan derivatives and polycycles were performed and optimized using CD-modified micellar CE. The most effective chiral selector for the enantiomeric separation of these analytes was hydroxypropyl-gamma-CD. The effects of CD and SDS concentration and organic modifier were examined in order to optimize the separation conditions. The ratio of CD to surfactant concentration affected the enantiomeric separation significantly, with increases in the derivatized CD concentration generally enhancing resolution. Addition of an organic solvent modifier to the run buffer served to increase the analytes' solubility and enhance the separation efficiency. A highly acidic pH was necessary to effectively suppress the EOF when operating in the reverse polarity mode.  相似文献   

6.
Nanoparticles (NPs) can be used as pseudostationary phases (PSPs) in EKC, which is similar to the use of micelle additives as applied in MEKC. To date, the use of NPs to enhance enantiomeric separation by EKC with β‐CD or its derivative as chiral selector has been reported only in two papers. However, to the best of our knowledge, there has been no prior effort to use NPs for achieving enantioseparation with polysaccharides as chiral selector. This paper describes for the first time the use of carbon nanoparticles (CNPs) as PSPs to modify chiral separation system employing dextrin as chiral selector for the enantioseparations of several basic drugs in capillary EKC. Three different types of CNPs, including carbogenic nanoparticles (NPs), carboxylated single‐walled carbon nanotubes, and carboxylated multiwalled carbon nanotubes, were used as running buffer additives, respectively. The potential of the PSPs and the effects of dextrin concentration, buffer pH, and buffer concentration on the enantioseparations were evaluated. Four pairs of tested enantiomers were successfully resolved in less than 15 min with the resolution values in the range of 1.41–4.52 under optimized conditions. Compared to the buffer without NPs, the introduction of NPs into the buffer enhanced the separation of the enantiomers.  相似文献   

7.
Lin B  Shi ZG  Zhang HJ  Ng SC  Feng YQ 《Electrophoresis》2006,27(15):3057-3065
Perphenylcarbamoylated beta-cyclodextrin bonded-silica particles (5 microm) were packed into 75-mum fused-silica capillaries, and used for the enantiomer separation of neutral and basic solutes by pressure-assisted capillary electrochromatography. Triethylammonium acetate and phosphate buffer were employed as the BGEs. A cathodic EOF was observed with these two BGEs. Seven chiral analytes were successfully resolved into their enantiomers under optimized conditions, and five of them could be baseline-separated within 12 min due to their high electrophoretic mobility. Better results were achieved with phosphate buffer as the BGE. The effects of organic content and pH on the enantioseparation were also investigated.  相似文献   

8.
Zhang M  El Rassi Z 《Electrophoresis》2000,21(15):3135-3140
A chiral silica-based stationary phase having surface-bound hydroxypropyl-beta-cyclodextrin (HP-beta-CD) with a relatively strong electroosmotic flow (EOF) was introduced for enantioseparation by capillary electrochromatography (CEC). The stationary phase contained a hydrophilic sulfonated sublayer to which a chiral top layer of HP-beta-CD was immobilized. While the sulfonated sublayer was to provide a relatively strong EOF, the top HP-beta-CD was to confer the desired chiral recognition towards enantiomeric solutes. This HP-beta-CD sulfonated silica (CDSS) stationary phase proved useful for the rapid separation of anionic enantiomers such as dansyl amino acids and phenoxy acid herbicides. The effects of the organic modifier content, pH, and ionic strength of the mobile phase on enantioseparation were investigated. Under the optimized separation conditions, ten dansyl amino acids and six phenoxy acid herbicides were enantioseparated with a resolution greater than unity.  相似文献   

9.
A novel procedure for in situ assembling a complex chiral selector, di-n-butyl l-tartrate–boric acid complex, by the reaction of di-n-butyl l-tartrate with boric acid in a running buffer was reported and its application in the enantioseparation of β-blockers and structural related compounds by chiral microemulsion electrokinetic chromatography (MEEKC) has been demonstrated. In order to achieve a good enantioseparation, the effect of dibutyl l-tartrate and sodium tetraborate concentration, surfactant identity and concentration, cosurfactant, buffer pH and composition, organic modifiers, as well as applied voltage and capillary length were investigated. Ten pairs of enantiomers that could not be separated with only dibutyl l-tartrate, obtained good chiral separation using the complex chiral selector; among them, seven pairs could be baseline resolved under optimized experimental conditions. The fixation of chiral centers by the formation of five-membered rings, and being oppositely charged with basic analytes were thought to be the key factors giving the complex chiral selector a superior chiral recognition capability. The effect of the molecular structure of analytes on enantioseparation was discussed in terms of molecular interaction.  相似文献   

10.
Nine racemic arylglycine amides were synthesized and successfully enantioseparated by capillary electrophoresis (CE) using highly sulfated beta-cyclodextrin (HS-beta-CD) as a chiral selector. Baseline enantioseparation of the analytes was obtained around neutral pH but not in the acidic conditions that are commonly used. HS-beta-CD content, buffer pH, type and concentration, and organic modifier concentration were studied and optimized for fast and efficient separation. A chiral CE separation system composed of 1.5% (w/v) HS-beta-CD, 0 to 10% (v/v) methanol and 20 mM 3-(N-morpholino)propanesulfonic acid at pH 6.5 was shown suitable for baseline enantioseparation of the mentioned amides within 6 min, including simultaneous enantioseparation of three positional isomer series (methyl-, methoxyl or chloro-substituted). By using this system, D-enantiomers migrated ahead of the L-enantiomers and the enantiomeric resolution order of arylglycine amides was more or less parallel to the pK(a), order of the analytes.  相似文献   

11.
Edwards SH  Shamsi SA 《Electrophoresis》2002,23(9):1320-1327
Chiral separation of moderately to highly hydrophobic polychlorinated biphenyls (PCBs) using a conventional chiral micelle or a polymeric chiral surfactant, as the single chiral selector is very difficult since the hydrophobic interactions between the chiral PCB and the monomeric or polymeric surfactant is very strong. Combined use of a polymeric chiral surfactant, polysodium N-undecanoyl-D-valinate (poly-D-SUV) with hydroxypropyl-gamma-cyclodextrin (HP-gamma-CD) was successful in cyclodextrin modified electrokinetic chromatography (CD-EKC) enantioseparation of PCB congeners. Addition of HP-gamma-CD to the background electrolyte containing poly-D-SUV functioned to improved chiral resolution for the PCBs and reduce the analysis time for these congeners. In addition, concentration of methanol, concentration of 2-(N-cyclohexylamino) ethanesulfonic acid (CHES) buffer and separation voltage was also varied to optimize multicomponent separation of five chiral PCBs. Simultaneous separation and enantioseparation of all five PCBs was possible in less than 50 min under optimized conditions that requires a 5 mM CHES solution buffered at about pH 10 with 1.5% w/v (ca. 60 mM) poly-D-SUV and 16 mM HP-gamma-CD. In addition, 1 M urea and 20% v/v methanol should be added as organic modifier and the capillary temperature maintained at 45 degrees C. As expected the polymeric surfactant showed improved chiral resolution of PCBs over conventional micelles of SUV. Under optimized conditions, when CD-EKC of chiral PCBs using poly-D-SUV was compared to sodium dodecyl sulfate (SDS), better resolution, higher efficiency and shorter analysis time was achieved with poly-D-SUV.  相似文献   

12.
The separation of thalidomide (TD) and its hydroxylated metabolites including their simultaneous enantioseparation was studied using three different polysaccharide-type chiral stationary phases (CSPs) in combination with polar organic mobile phases. Three different techniques, high-performance liquid chromatography in common-size columns, capillary LC and nonaqueous capillary electrochromatography were compared in terms of separation. As this study illustrates, polar organic mobile phases represent a valuable extension for less polar and polar aqueous-organic mobile phases in combination with polysaccharide CSPs. Chiralpak AD consisting of 25% of amylose-tris(3,5-dimethylphenylcarbamate) coated on wide-pore aminopropylsilanized silica gel exhibited higher resolving ability compared to the similar cellulose derivative (Chiralcel OD) as well as to cellulose-tris(4-methylbenzoate) (Chiralcel OJ) CSPs for this particular set of chiral analytes. Baseline separation and simultaneous enantioseparation of all three compounds could be achieved under optimized separation conditions.  相似文献   

13.
A novel positively charged single-isomer of β-cyclodextrin, mono-6-deoxy-6-(3R,4R-dihydroxypyrrolidine)-β-CD chloride (dhypy-CDCl), was synthesized and employed as a chiral selector for the first time in capillary electrophoresis (CE) for the enantioseparation of anionic and ampholytic acids. The effects of the running buffer pH, chiral selector concentration, analyte structure and organic modifier on the enantioseparation were studied in detail. The chiral selectivity and resolution for most of the studied analytes decreased as the buffer pH increased in the range of 6.0–9.0. Increasing selector concentration led to decreased effective mobility, increased chiral selectivity and resolution for most of the studied analytes. Moreover, the hydroxyl groups located on the dihydroxypyrrolidine substituent of the dhypy-CDCl could have influence on the chiral separation.  相似文献   

14.
Weak anion-exchange (WAX) type chiral stationary phases (CSPs) based on tert.-butyl carbamoyl quinine as chiral selector (SO) and different types of silica particles (porous and non-porous) as chromatographic support are evaluated in packed capillary electrochromatography (CEC). Their ability to resolve the enantiomers of negatively charged chiral analytes, e.g., N-derivatized amino acids, in the anion-exchange mode and their electrochromatographic characteristics are described in dependence of several mobile phase parameters (pH, buffer type and concentration, organic modifier type and concentration) and other experimental variables (electric field strength, capillary temperature). The inherent "zwitterionic" surface character of such silica-based WAX type CSPs (positively charged SO and negatively charged residual silanols) allows the reversal of the electroosmotic flow (EOF) towards the anode at pH values below the isoelectric point (pI) of the modified surface, whereas a cathodic EOF results at pH values above the pI. Since for negatively charged analytes also an electrophoretic transport increment has to be considered, which can be either in or against the EOF direction, several distinct modes of elution have been observed under different stationary phase and mobile phase conditions: (i) co-electrophoretic elution of the negatively charged solutes with the anodic EOF in the negative polarity mode, (ii) counter-electrophoretic elution with the cathodic EOF in the positive polarity mode, and (iii) electrophoretically dominated elution in the negative polarity mode with a cathodic EOF directed to the injection end of the capillary. Useful enantioseparations of chiral acids have been obtained with all three modes. Enantioselectivity values as high as under pressure-driven conditions and theoretical plate numbers up to 120000 per meter could be achieved under electrically driven conditions. A repeatability study yielded RSD values below 2% for retention times and RSD values in the range of 5-10% for theoretical plate numbers and resolution, thus clearly establishing the reliability of the investigated anion-exchange type CEC enantioseparation methods.  相似文献   

15.
The chiral resolving ability of a novel single-isomer cationic β-cyclodextrin (CD), mono-6A-propylammonium-6A-deoxy-β-cyclodextrin chloride (PrAMCD), as a chiral selector in capillary electrophoresis (CE) is reported in this work for the enantioseparation of hydroxy, carboxylic acids and amphoteric analytes. The effect of chiral selector concentration on the resolution was studied. Good resolutions were achieved for hydroxy acids. Optimum resolutions were obtained even at 3.5 mM CD concentration for carboxylic acids. The electrophoretic method showed good linearity and reproducibility in terms of migration times and peak areas, which should make it suitable for routine analysis. In addition, baseline chiral separation of a six-acid mixture was achieved within 20 min. PrAMCD proved to be an effective chiral selector for acidic analytes.  相似文献   

16.
表面活性剂在高效毛细管电泳中的作用   总被引:3,自引:0,他引:3  
关福玉 《色谱》1995,13(1):30-32
表面活性剂作为缓冲液添加剂已广泛用于高效毛细管电泳中,综述了阴离子、阳离子、两性离子、非离子及手性等多种表面活性剂在离子、中性分子、手性化合物、多肽和蛋白质分离等方面的作用,介绍了其作用机理与改善高效毛细管电泳分离的原理。  相似文献   

17.
Li X  Zhou ZM  Xu D  Zhang J 《Talanta》2011,84(4):183-1092
Two new chiral stationary phases (CSP) were successfully prepared through bonding β-cyclodextrin (CD) derivatives modified by R-configuration groups (R-CPGCD, R-HMPGCD) to silica gel. Nineteen chiral nitro aromatic alcohol derivatives were separated under the polar organic and the reversed phase modes. Better enantioseparation was obtained in the reversed phase mode. The resolution values of the analytes ranged from 1.98 to 7.57 and from 2.19 to 8.14 on R-CPGCD and R-HMPGCD CSPs, respectively, using a mobile phase composed of methanol/water (v/v, 40/60). Better enantioseparation was obtained on R-HMPGCD CSP than on R-CPGCD CSP because of stronger hydrogen bonding and π-π interactions between the substituents on the cyclodextrin derivatives and the analytes. For different analytes, the increasing electronic density of the benzene ring was found to be favorable to the enantioseparation of the test analytes. The thermodynamic parameters showed that the enantioseparation of analytes was enthalpy-controlled and a lower temperature aided the enantiomeric separation of the solutes on the two CSPs. MD simulations were used to investigate the recognition mechanism between the chiral selectors and the analyte using R-, S-2-naphthalenemethanol and R-CPGCD and R-HMPGCD complexes as examples. S-2-naphthalenemethanol had the stronger interactions with R-CPGCD and R-HMPGCD than the R-isomer. The substituent derivatized on R-CPGCD and the cyclodextrin cavity contributed to the discrimination of the S-isomer, but only the derivatized group on R-HMPGCD was found to play a major role in separating prosess. In addition, the larger free energy deviation of the R- and S-isomers in the R-HMPGCD system brought about a higher resolution value (Rs = 8.14).  相似文献   

18.
In capillary electrophoresis (CE), separation of enantiomers of a chiral compound can be achieved through the chiral interactions and/or complex formation between the chiral selector and the enantiomeric analytes on leaving their diastereomeric forms with different stability constants and hence different mobilities. A great number of chiral selectors have been employed in CE and among them macrocyclic antibiotics exhibited excellent enantioselective properties towards a wide number of racemic compounds. The use of azithromycin (AZM) as a chiral selector has not been reported previously. This work reports the use of AZM as a chiral selector for the enantiomeric separations of five chiral drugs and one amino acid (tryptophan) in CE. The enantioseparation is carried out using polar organic mixtures of acetonitrile (ACN), methanol (MeOH), acetic acid and triethylamine as run buffer. The influences of the chiral selector concentration, ACN/MeOH ratio, applied voltage and capillary temperature on enantioseparation are investigated. The results show that AZM is a viable chiral selector in CE for the enantioseparation of the type of chiral drugs investigated.  相似文献   

19.
In this work, a new open-tubular capillary electrochromatography (OT-CEC) column was prepared using β-cyclodextrin covalent organic framework (β-CD COF) as a stationary phase. Polydopamine was used to assist fabrication of β-CD COF on an inner wall of a fused-silica capillary. The coating layer on the capillary was characterized by scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR). Electroosmotic flow (EOF) was also studied to evaluate the variation of the inner wall of immobilized columns. Furthermore, the chiral separation effectiveness of the fabricated capillary column was evaluated by CEC using enantiomers of several related proton pump inhibitors as model analytes, including omeprazole, lansoprazole, pantoprazole and tenatoprazole. The effects of bonding time and concentration of β-CD COF, the type, concentration and pH of buffer, applied voltage were investigated to obtain satisfactory enantioselectivity. In the optimum conditions, the enantiomers of four analytes were resolved within 15 min with resolutions of 1.63–2.62. The relative standard deviation values for migration times and resolutions of the analytes representing intraday and interday were less than 6.75% and 4.24%, respectively. The results reveal that β-CD COF has great potential as chiral-stationary phases for enantioseparation in CEC.  相似文献   

20.
Enantioseparations of fourteen dansyl amino acids were achieved by using a positively-charged single-isomer beta-cyclodextrin, mono-(3-methyl-imidazolium)-beta-cyclodextrin chloride, as a chiral selector. Separation parameters such as buffer pH, selector concentration, separation temperature, and organic modifier were investigated for the enantioseparation in order to achieve the maximum possible resolution. Chiral separation of dansyl amino acids was found to be highly dependent on pH since the degree of protonation of these amino acids can alter the strength of electrostatic interaction and/or inclusion complexation between each enantiomer and chiral selector. In general, the chiral resolution of dansyl amino acids was enhanced at higher pH, which indicates that the carboxylate group on the analytes may interact with the imidazolium group of cationic cyclodextrin. For most analytes, a distinct maximum in enantioresolution was obtained at pH 8.0. Moreover, the chiral separation can be further improved by careful tuning of the separation parameters such as higher selector concentration (e.g. 10 mM), lower temperature, and addition of methanol. Enantioseparation of a standard mixture of these dansyl amino acids was further achieved in a single run within 30 min.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号