首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
《Analytica chimica acta》2002,470(2):205-214
A new analytical method based on the cloud-point extraction (CPE) methodology combined with high-performance liquid chromatography is used in this study for the extraction and quantification of polychlorinated dibenzo-p-dioxins. These compounds are extracted by using the non-ionic surfactant polyoxyethylene 10 lauryl ether (POLE) from different aqueous systems: fresh, brackish and sea waters. After the cloud-point extraction, which also allowed a preconcentration of the PCDDs being studied, the samples were analysed using a HPLC-UV system under the optimum chromatographic conditions. The proposed method showed very satisfactory recovery percentages for the PCDDs under study and standard deviation values lower than 2%.The results obtained were finally compared with those found using the traditional liquid-liquid extraction method.  相似文献   

2.
A simple cloud-point extraction method for the determination of meloxicam in human serum was developed. Meloxicam was extracted from serum sample after adding 1 mL of 3% (v/v) Triton X-114 aqueous solution in the presence of 1M HCl and 60 mg NaCl. The meloxicam, present in the surfactant-rich phase, was enriched again with acetonitrile. Tenoxicam was used as the external standard. The separation was achieved on a C18 analytical column with a mobile phase consisting of aqueous acetic acid (1%, v/v) and acetonitrile (54:46, v/v). UV detection was performed at 360 nm. The response was linear over the range 45–2000 ng mL−1 in human serum, and intra- and interday precisions of less than 15.0% were obtained. The relative error was within ±3.0%. The recoveries of meloxicam were larger than 92.0%. The method was compared with liquid–liquid extraction. The results showed that the new method has a considerable LOQ and higher recoveries but poorer precision than liquid–liquid extraction, which exhibited poor recoveries of less than 86.0%, precisions of less than 5.0% and relative errors of less than 7.0%. The method was used for the determination of meloxicam in healthy human volunteers.  相似文献   

3.
This article proposes an alternative method, using cloud-point extraction and gas chromatography, for extraction and determination of disulfoton in water samples. For cloud-point extraction, the nonionic surfactant Triton X-114 was used. Before gas chromatography, a cleanup stage for surfactant removal from the extracts was optimized. Cleanup used two columns, in series, containing silica gel and Florisil, with methanol:hexane (1?:?1) as eluent, resulting in the removal of more than 95% of the Triton X-114. Factors such as ionic strength (>0.5?mol?L?1) and surfactant concentration (1.0% w/v) increased the extraction efficiency of the cloud-point methodology, yielding disulfoton recoveries of almost 100%. Compared with liquid–liquid extraction, the cloud-point methodology was more efficient, with a better detectability, and resulted in a significant reduction in solvent volume.  相似文献   

4.
A new straightforward method based on cloud-point extraction (CPE) was developed to determine osthole in rat plasma by reversed phase high-performance liquid chromatography with ultraviolet detection using a photodiode array detector. The non-ionic surfactant Triton X-114 was chosen as the extract solvent. Variable parameters affecting the CPE efficiency were evaluated and optimized. A Zorbax SB-C18 column was used for elution separation at 25 °C with detection wavelength at 322 nm. Under the optimum conditions, the method was shown to be reproducible and reliable with intra-day precision below 7.62%, inter-day precision below 6.37%, and accuracy within ±5.02% and mean extraction recovery more than 90.4%, which were all calculated using a range of spiked samples at three concentrations of 0.5, 5.0 and 15.0 μg mL−1 for osthole in plasma. The calibration curve for the analyte was linear in the range from 0.1 to 20 μg mL−1 with the correlation coefficients greater than 0.9981. Limit of detection (S/N = 3) was less than 0.03 μg mL−1and limit of quantification (S/N = 10) was less than 0.1 μg mL−1. After strict validation, the method was successfully applied to the pharmacokinetic study of osthole in rats after oral and intravenous administration, respectively.  相似文献   

5.
Summary A sample preparation method has been developed for the determination of chlorinated phenols in water. The method is based on a supported liquid membrane extraction system connected on-line to liquid chromatography with electrochemical detection. The supported liquid membrane technique utilizes a porous PTFE membrane. The membrane is impregnated with an organic solvent which forms a barrier between two aqueous phases and enables selective extraction. The technique can easily be coupled in a flow system. In this investigation five chlorinated phenols (1–5 chlorine atoms) were extracted from natural water samples. Extraction for 30 minutes resulted in detection limits of approximately 25 ng L–1.  相似文献   

6.
Summary Two analytical methods have been developed for the determination in water of 18 priority phenolics listed in US EPA method 604 and on EEC list 76/464. A solidphase extraction system using eight different sorbents packed in a precolumn was coupled on-line with a liquid chromatograph with UV detection. The ensuing method uses 50–100 mL of ground water; its performance was compared with that of an off-line method using Empore extraction disks and 1 L water samples. Phenol recoveries varied from <20 to 100% for concentrations in the range 0.1–10 g/L at an acid pH. The presence of the phenols in water was confirmed by using thermospray LC-mass spectrometry in the negative ion mode. The stability of the phenols in water was studied at a 10 g/l level in ground and estuarine water at acid pH (2.5–3) and at 4°C for 1 month. The system was validated by various interlaboratory exercises with samples containing 2,4,6-trichlorophenol and pentachlorophenol at concentrations from 0.1 to 0.5 g/L.  相似文献   

7.
A cloud-point extraction (CPE) method using Triton X-114 non-ionic surfactant was developed for the extraction and preconcentration of carbamate insecticide residues (i.e., methomyl, propoxur, carbofuran, carbaryl, isoprocarb, and promecarb) in fruit samples. The optimum conditions of CPE were 1.5% (w/v) Triton X-114, 7.0% (w/v) NaCl and 20 min equilibrated at 45 °C. The surfactant-rich phase was then analyzed by reversed-phase high-performance liquid chromatography with ultraviolet detection at 270 nm, under gradient separation using methanol and 0.1% (v/v) acetic acid. Under the study conditions, six carbamate insecticides were successfully separated within 27 min. Good reproducibility was obtained with the relative standard deviation of <3% for retention time and <9% for peak area. Limits of detection in the studied fruit samples were in the range of 0.1–1.0 mg kg−1. No carbamate insecticides were detected in the studied fruit samples. The high recoveries of the spiked fruit samples were obtained in the range 80.0–107%. The CPE method has been shown to be a potential useful methodology for the preconcentration of the target analytes, with a preconcentration factor of 14. Moreover, the method is simple, has high sensitivity, consumes much less solvent than traditional methods, and is environmental friendly.  相似文献   

8.
Jihai Zhou 《Talanta》2009,79(2):189-1249
A CPE-HPLC (UV) method has been developed for the determination of Prometryne. In this method, non-ionic surfactant Triton X-114 was first used to extract and pre-concentrate Prometryne from water and soil samples. The separation and determination of Prometryne were then carried out in an HPLC-UV system with isocratic elution using a detector set at 254 nm wavelength. The parameters and variables that affected the extraction were also investigated and the optimal conditions were found to be 0.5% of Triton X-114 (w/v), 3% of NaCl (w/v) and heat-assisted at 50 °C for 30 min. Using these conditions, the recovery rates of Prometryne ranged from 92.84% to 99.23% in water and 85.48% to 93.67% in soil, respectively, with all the relative standard deviations less than 3.05%. Limit of detection (LOD) and limit of quantification (LOQ) were 3.5 μg L−1 and 11.0 μg L−1 in water and 4.0 μg kg−1 and 13.0 μg kg−1 in soil, respectively. Thus, we developed a method that has proven to be an efficient, green, rapid and inexpensive approach for extraction and determination of Prometryne from soil samples.  相似文献   

9.
This paper presents a novel analytical method for the determination of pyridinium ionic liquid cations in environmental water samples by ion chromatography coupled with solid phase extraction. The water samples were purified and enriched by a sulphonic acid extraction column, and then the impurities were washed with 10 mL water – 20% (v/v) acetonitrile solution and the analytes eluted with 0.5 mol L?1 phosphoric acid – sodium dihydrogen phosphate buffer solution – 55% methanol. The eluted analytes were determined by ion chromatography with 3.0 mmol L?1 methane sulphonic acid – 8% acetonitrile as the mobile phase and direct conductivity detection. Three pyridinium cations were completely separated in 20 min and the retention mechanism basically conforms to the ion exchange mode. The newly developed method has been successfully applied to the analysis of pyridinium cations in spiked environmental water samples, which provided satisfactory recoveries in the range of 98.8% to 100.0% with the relative standard deviations less than 2.8%. The concentration of 0.004 to 0.01 mg L?1 in water samples can be preconcentrated by this method. The method is accurate, reliable, simple and practical. This research provides a new reference for detecting ionic liquid cations in environmental water samples and studying the environmental risk assessment of ionic liquids.  相似文献   

10.
This study introduced a new microextraction method named temperature-induced dispersive solid-phase extraction. The performance of the method was demonstrated with the determination of Sudan dyes in food and natural water samples. In this method, a low quantity of sorbent was added to the aqueous solution and the mixture was shaken manually for about one minute. Then, the solution was heated in an ultrasonic water bath, and the sorbent was dissolved. Subsequently, the solution was cooled down with ice water, and consequently, the solubility of the sorbent was reduced in the sample solution and became cloudy. The phase separation was accelerated by centrifugation. The upper liquid phase was picked up using a syringe, and the remainder was solved in methanol and introduced into the HPLC for analysis. Various parameters affecting the extraction yield were evaluated. Analytical parameters, including limits of detection (0.011–0.016 μg/L) and quantification (0.038–0.055 μg/L), relative standard deviations (2.3%–3.1%), and preconcentration factor (40) proved the high efficiency of the developed method for the analysis of Sudan dyes. The proposed method was used to measure Sudan dyes in water and food samples and showed good extraction recoveries (95.0%–103.5%).  相似文献   

11.
By using ionic liquid as membrane liquid and tri-n-octylphosphine oxide (TOPO) as additive, hollow fiber supported liquid phase microextraction (HF-LPME) was developed for the determination of five sulfonamides in environmental water samples by high-performance liquid chromatography with ultraviolet detection The extraction solvent and the parameters affecting the extraction enrichment factor such as the type and amount of carrier, pH and volume ratio of donor phase and acceptor phase, extraction time, salt-out effect and matrix effect were optimized. Under the optimal extraction conditions (organic liquid membrane phase: [C8MIM][PF6] with 14% TOPO (w/v); donor phase: 4 mL, pH 4.5 KH2PO4 with 2 M Na2SO4; acceptor phase: 25 μL, pH 13 NaOH; extraction time: 8 h), low detection limits (0.1–0.4 μg/L, RSD ≤ 5%) and good linear range (1–2000 ng/mL, R2 ≥ 0.999) were obtained for all the analytes. The presence of humic acid (0–25 mg/L dissolved organic carbon) and bovine serum albumin (0–100 μg/mL) had no significant effect on the extraction efficiency. Good spike recoveries over the range of 82.2–103.2% were obtained when applying the proposed method on five real environmental water samples. These results indicated that this present method was very sensitive and reliable with good repeatabilities and excellent clean-up in water samples. The proposed method confirmed hollow fiber supported ionic liquid membrane based LPME to be robust to monitoring trace levels of sulfadiazine, sulfamerazine, sulfamethazine, sulfadimethoxine and sulfamethoxazole in aqueous samples.  相似文献   

12.
Anion-exchange solid-phase extraction accompanied with high-performance liquid chromatography has been developed for the determination of six kinds of aminopolycarboxylic acids (APCAs) in river water [N-(2-hydroxyethyl)ethylenediaminetriacetate (HEDTA), ethylenediaminetetraacetate (EDTA), 1,3-propanediaminetetraacetate (PDTA), diethylenetriaminepentaacetate (DTPA), 1,2-propanediaminetetraacetate (MeEDTA), and O,O′-bis(2-aminoethyl)ethyleneglycoltetraacetate (GEDTA)]. The enrichment of APCAs using an anion-exchange cartridge was successfully done by the removal of anions, which competed with APCAs in anion-exchange processes. Barium chloride solution was added to river water and the mixture was passed through On Guard II Ag and H cartridges and then a Bond Elut Jr.SAX cartridge to enrich APCAs. After elution, APCAs were analyzed on two reversed phase C30 columns connected in series and detected with ultraviolet detection. The enrichment using solid-phase extraction permitted the determination of APCAs in river water at concentrations as low as 1 nM. Good recoveries (83–111%) were obtained for each APCA by the standard addition method on three river water samples with high accuracy (RSD 1.8–9.5%). Applying this method, two kinds of APCAs, EDTA and DTPA, were determined in samples from the Oyabe and Senbo Rivers in Japan.  相似文献   

13.
A new and sensitive precolumn derivatisation with dabsyl chloride was developed for the analysis of melamine in water samples by high-performance liquid chromatography (HPLC) with visible detection. Derivatisation with dabsyl chloride leads to improving sensitivity and hydrophobicity of melamine. Under optimum conditions of derivatisation and microextraction, the method yielded a linear calibration curve ranging from 10 to 2000 µg L?1 with a determination coefficient (R2) of 0.9952. Limit of detection (LOD) and limit of quantification (LOQ) were 2.0 and 6.0 µg L?1, respectively. The relative standard deviation per cent (RSD%) for intraday and inter-day extraction and determination at 20 and 200 µg L?1 levels of melamine was less than 8.2% (n = 6). Finally, the proposed method was successfully applied for the determination of melamine in different water samples and satisfactory results were obtained (relative recovery ≥91%).  相似文献   

14.
Antidepressants are widely used for the treatment of psychiatric disorders and therefore their monitoring in biological fluids is quite important taking into account that they can produce dangerous biochemical imbalances in toxic doses. A method for the determination of antidepressants in urine samples is presented using solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) with ultraviolet (UV) detection. Home-made cartridges containing 30 mg multiwall carbon nanotubes are employed for isolation of the analytes from the sample, allowing also the preconcentration of the analytes prior to the HPLC analysis. Chromatographic separation was achieved in a reversed-phase C8 column using the ionic liquid 1-butyl-3-methylimidazolium trifluoromethanesulfonate as silanol activity suppressor, which enhances peak symmetry and chromatographic resolution. Limits of detection were 12.3 ng mL−1 for trazodone and 90.1 ng mL−1 for fluoxetine. The repeatability of the proposed method expressed as RSD (n = 11) varied between 3.4% (fluoxetine) and 5.0% (desipramine and mianserine). Thus, the method is suitable for the therapeutic monitoring of antidepressants in urine samples.  相似文献   

15.
A simple, rapid, efficient, and environmentally friendly method for the determination of some triazine herbicides (simazine, atrazine, prometone, ametryn and prometryne) in water samples was developed by ultrasound-assisted emulsification microextraction (USAEME) coupled with high-performance liquid chromatography-diode array detection (HPLC-DAD). The main parameters that affect the extraction efficiencies, such as the kind and volume of the extraction solvent, ultrasound emulsification time and salt addition, were investigated and optimized. Under the optimum conditions, the method was sensitive and showed a good linearity within a range of 0.5 to 200?ngm?L?1 for simazine, atrazine, prometone, ametryn and prometryne, with the correlation coefficients (r) varying from 0.9993 to 0.9998. High enrichment factors were obtained ranging from 148 to 225. The limits of detection (LODs) were in the range between 0.06 and 0.1?ngm?L?1 and the limits of quantification (LOQs) were in the range between 0.2 and 0.3?ngm?L?1. The recoveries of the analytes from water samples at spiking levels of 5.0 and 50.0?ngm?L?1 were ranged from 82.4% to 107.0%. The relative standard deviations (RSDs) varied from 3.0% to 4.6%. The results demonstrated that the USAEME-HPLC-DAD method was an ef?cient pretreatment and enrichment procedure for the determination of triazine pesticides in real water samples.  相似文献   

16.
Pressurized liquid extraction (PLE) is a relatively new technique applicable for the extraction of persistent organic pollutants from various matrices. The main advantages of this method are short time and low consumption of extraction solvent. The effects of various operational parameters (i.e. temperature of extraction, number of static cycles and extraction solvent mixtures) on the PLE efficiency were investigated in this study. Fish muscle tissue containing 3.2% (w/w) lipids and native polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and other related compounds was used for testing. Purification of crude extracts was carried out by gel permeation chromatography employing Bio-Beads S-X3. Identification and quantitation of target indicator PCBs and OCPs was performed by high-resolution gas chromatography (HRGC) with two parallel electron-capture detectors (ECDs). Results obtained by the optimized PLE procedure were compared with conventional Soxhlet extraction (the same extraction solvent mixtures hexane–dichloromethane (1:1 v/v) and hexane–acetone (4:1 v/v) were used). The recoveries obtained by PLE operated at 90–120 °C were either comparable to “classic” Soxhlet extraction (for higher-chlorinated PCB congeners and DDT group) or even better (for lower chlorinated analytes). The highest recoveries were obtained for three static 5 min extraction cycles.  相似文献   

17.
建立了分散液相微萃取.气相色谱,质谱快速分析水中硝基苯、对硝基苯、1,3一二硝基苯和2,4-二硝基氯苯的新方法.将含有18μL氯苯(萃取荆)的0.25 mL丙酮(分散剂)作为萃取体系,快速注入到5.0 mL水溶液中.在4000r/min下离心2.0 min后,得到(10.0±0.5)μL沉积相(氯苯),取底部沉积相1.0μL进行气相色谱,质谱分析.方法线性范围0.5~50μg/L(r2=0.9986~0.9994),检出限0.2~0.5μg/L,相对标准偏差4.2%~7.3%(n=5).将该方法用于环境水样的测定,加标回收率72.9%~89.6%.  相似文献   

18.
A method for rapid extraction and determination of some crown ethers in aqueous matrices using octadecyl-bonded silica membrane disks and gas chromatography is presented. Extraction efficiency and the influence of vacuum pressure. pH, and type and least amount of eluting solvent used to extract the crown ethers from the membrane disks were evaluated. Extraction efficiencies > 95% were obtained for benzo-15-crown-5, benzo-18-crown-6 and dicyclohexyl-18-crown-6 using 5 ml of acetonitrile as eluting solvent. The limit of detection of the proposed method for the determination of the crown ethers is reported.  相似文献   

19.
In this study, a simple and rapid extraction method based on the application of polypyrrole‐coated Fe3O4 nanoparticles as a magnetic solid‐phase extraction sorbent was successfully developed for the extraction and preconcentration of trace amounts of formaldehyde after derivatization with 2,4‐dinitrophenylhydrazine. The analyses were performed by high‐performance liquid chromatography followed by UV detection. Several variables affecting the extraction efficiency of the formaldehyde, i.e., sample pH, amount of sorbent, salt concentration, extraction time and desorption conditions were investigated and optimized. The best working conditions were as follows: sample pH, 5; amount of sorbent, 40 mg; NaCl concentration, 20% w/v; sample volume, 20 mL; extraction time, 12 min; and 100 μL of methanol for desorption of the formaldehyde within 3 min. Under the optimal conditions, the performance of the proposed method was studied in terms of linear dynamic range (10–500 μg/L), correlation coefficient (R2 ≥ 0.998), precision (RSD% ≤ 5.5) and limit of detection (4 μg/L). Finally, the developed method was successfully applied for extraction and determination of formaldehyde in tap, rain and tomato water samples, and satisfactory results were obtained.  相似文献   

20.
Abstract

Sediment cores were collected at the MOLAR (MOuntain LAke Research) site Jörisee. The goal of the analysis was to date the sediment cores in order to correlate actual input conditions of nutrients and pollutants at this high-alpine, remote site, to historical situations. The sediment cores were dated by determining gamma rays of Pb-210 and Cs-137. The calculated sedimentation rate is 0.1 cm/year. Leaching techniques were used to investigate redox sensitive species. The results give evidence for post depositional recycling in case of Fe and Mn. In contrast, the heavy metals Pb, Zn, Cr and Ni are not affected by existing redox gradients. Sediment samples were leached with diluted nitric acid to determine anthropogenic input of Pb, Zn, Cr and Ni. Concentrations of these heavy metals reflect changes in the input conditions since the beginning of industrialization, which is the examined time period.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号