首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 421 毫秒
1.
The CR-39 detectors are widely used as passive radon dosimeters, as well as in physics laboratories or for industrial applications. For what concerns radon monitoring, the calibration curve which is usually adopted corresponds to a linear relation between the actual etched track density and the track density counted by an automatic acquisition system. This linear calibration provides very accurate radon exposure assessments in a restricted range of etched track density, however it neglects the effect of the tracks overlapping that becomes as relevant as the track density increases. In the present work the mathematical expression of the area covered by a set of uniformly distributed tracks is deduced. This result allows then to infer the probability that the system acquires the right track density, providing a general calibration curve for a solid state radon track detector. The process of track production and reading routine is also simulated adopting a Monte Carlo approach, showing that the obtained results are in agreement with the function proposed as calibration curve. Moreover, a linear dependence between the track average area and the rate parameter of the calibration curve has been observed. Finally a semi-empirical correlation based on the previous results is proposed.  相似文献   

2.
《Radiation measurements》2003,36(1-6):329-334
Different stacks of tissue equivalent targets interleaved with CR-39 nuclear track detectors were irradiated with 135 MeV/u 12C and 16O ions. After track etching and measurement by an automatic image analysis system, a method of trajectory tracing was applied. The trajectories of particles were reconstructed using a pattern-matching method based on a comparison of relative track coordinates.

Fragmentation products have a lower charge and can be clearly distinguished by their smaller track sizes. The track positions within the individual trajectory are additionally fitted to a straight line, from which we can determine the direction of the traversing ion within a path of a few mm. We performed an angular distribution study of the fragments, which we compared to simulation results obtained by a simple particle emission model. For the fitted parameters the model showed agreement within the margins of error but failed to describe the energy dependence and thus should be further improved and upgraded.  相似文献   


3.
The purpose of this work is to determine alpha track density on solid state nuclear track detectors (SSNTDs) such as CR-39 efficiently with minimal time. Samples of CR-39 were irradiated with different doses from an alpha emitter. These samples were chemically etched and the tracks counted using an optical microscope. The intensity of the transmitted light (λ=400–1200 nm) through irradiated and etched CR-39 was measured using a photomultiplier. For all wavelengths used in this study, it is found that the transmittance of light decreases as irradiation time increases. In addition, the calibration factor was calculated from the relation between track density on CR-39 and light transmittance. The procedure appeared to be a good and fast technique for determining radon concentration in the environment and consequently dose reading.  相似文献   

4.
A passive neutron dosemeter with thermoluminescence and etched-track detectors was used in the space station MIR in 1995 and 1997 and during some shuttle flights to MIR. High neutron doses of about 200 microSv d-1 were measured with track detectors, while the contribution of protons to the track density was estimated to be small. An active personal dosemeter based on silicon diodes providing a direct readout, improved sensitivity and spectrometric properties is proposed for additional monitoring. Firstly, measurements with a prototype were performed in the stray radiation fields of the CERN-EU Reference Radiation Facility. When mounted on a phantom at different positions, both the passive and the active dosemeter provide the directional distribution of neutrons via an unfolding procedure. This can be helpful for a better understanding of the complex radiation field in space and for comparisons with calculations.  相似文献   

5.
The results of an experimental work aimed at improving the performance of the CR-39 nuclear track detector for neutron dosimetry applications are reported. A set of CR-39 plastic detectors was exposed to 252Cf neutron source, which has the emission rate of 0.68 × 108 s−1, and neutron dose equivalent rate 1 m apart from the source is equal to 3.8 mrem/h. The detection of fast neutrons performed with CR-39 detector foils, subsequent chemical etching and evaluation of the etched tracks by an automatic track counting system was studied. It is found that the track density increases with the increase of neutron dose and etching time. The track density in the detector is directly proportional to the neutron fluence producing the recoil tracks, provided the track density is in the countable range. This fact plays an important role in determining the equivalent dose in the field of neutron dosimetry. These results are compared with previous work. It is found that our results are in good agreement with their investigations.   相似文献   

6.
Two techniques have been developed to investigate the characteristic of the sensitivity of CR-39 (polyallyldiglycol carbonate) track detector using Am---Be neutron source. The firstis to measure volume track density created by fast neutrons in CR-39 detectors. The second is to measure areal asymptotic track density on the surface of CR-39 sheets. Two types of CR-39—SY-2 CR-39 made in China and another made in USA were calibrated using the techniques. It shows that the two types of CR-39 detectors have nearly the same sensitivity to detect fast neutrons. The techniques developed in this work can be applied to calibration of other track detectors.  相似文献   

7.
Abstract

The effects of neutron, gamma and alpha radiations on the alpha and fission fragment tracks registration and revelation properties of CR-39 detectors (CR-39 and CR-39(DOP) were studied. It was found that the ratio of the bulk etch rate of irradiated to unirradiated (VG(irr.)/VG(unirr.) detectors is linearly dependent on dose. An exponential decrease in fission track densities with increase in neutron fluence was observed. The ratio of VG(irr.)/VG(unirr.) was found to be high in CR-39 than that in CR-39(DOP) exposed to the same reactor neutron fluence. The decrease in fission track densities with increase in neutron fluence was observed to be faster in CR-39 than in CR-39(DOP). This indicates that doping with dioctyl phthalate improves the radiation resistance of CR-39 detectors. It was observed that in detectors exposed to an alpha flux of the order of 9.36 × 106 / cm2, the fission track density was reduced by 11% and thereafter it remained constant. The results also indicate that thermal neutron fluence up to 7.01 ×1011 neutrons/cm2 does not affect the alpha and fission track densities. I.R. spectra were also studied to find out the nature of chemical changes produced by these radiations on CR-39.  相似文献   

8.
A miniature diffusion chamber with a 25 × 4 × 0.5 mm CR-39 track etch detector (Pershore Moulding Ltd.), mounted on the 1.1 m long pole has been developed for radon gas measurements at 1 meter depth in the soil. For chemically etched CR-39 (7h, 70°C NaOH) and automatic track analysis the lowest detection limit of the chamber was found to be 0.5 MBq h m−3 and the useful exposure range from 2 to 20 MBq h m−3. The typical exposure time in the soil is between 2 to 14 days. The chamber was tested against the active AlphaGUARD PQ-2000 (Genitron Instruments GmbH) probe. The test yielded consistent results for soils with typical values of permeability and which are not miniature with water. The pilot measurements of radon gas in soil conducted with the miniature diffusion chambers around 48 buildings in Kraków and Silesia regions yielded an average radon concentration of 13 kBq m−3. The chambers are to be applied to measure radon concentration in soil before constructing new houses in order to avoid high radon risk areas.  相似文献   

9.
In the Laboratory of Nuclear Microanalysis, we have developed two techniques for neutron dosimetry; the first for low fluence, the second for high fluence. These two techniques use a Solid State Nuclear Track Detector (SSNTD): the CR-39. The low fluence technique is based on the measurement of etched tracks resulting from a neutron-proton conversion. A Monte Carlo code performs a simulation of the (n,p) collision in the detector, and a numerical computer code of latent track etching allows the evaluation of the etched track parameters. The object of this is to obtain characteristics of a neutron fluence from the measured etched track parameters. When there is a high fluence and high doses, CR-39 is unsuited for optical microscopy analysis. This is because of track overlapping which makes it impossible to carry out counting and exploitation. We have therefore developed a new method permitting the reading of samples based on the measurement of the angular distribution of coherent light (He---Ne laser) transmitted through the irradiated etched SSNTD. We present these two techniques and our initial results.  相似文献   

10.
CR-39 (PADC) a Solid State Nuclear Track Detector., is used as a routine personnel monitor. 1800 workers are being monitored quarterly for fast neutron using CR-39 foils. These foils procured from Pershore Mouldings, UK are very expensive and indigenous development will make the foils cost effective. The aim of this paper is to find a suitable alternative to the imported CR-39 foils for use in personnel monitoring. The foils from three different manufacturers have been compared with the CR-39 foils from Pershore Moulding, UK, presently in use. Out of the three, only sample no 1 is promising. It has a background and sensitivity comparable with CR-39 presently used. The sample 2 is CR-39 being developed in India, has a relatively high background and poor sensitivity. Efforts are being made to improve the quality of this sample. The sample 3 was a poly carbonate from local manufacturer which produced very few tracks and the standard deviation of track counts was very large and hence not useful for Personnel Monitoring.   相似文献   

11.
Atomic Force Microscope (AFM) has been applied to evaluate the surface roughness and the track sensitivity of CR-39 track detector. We experimentally confirmed the inverse correlation between the track sensitivity and the roughness of the detector surface after etching. The surface of CR-39 (CR-39 doped with antioxidant (HARZLAS (TD-1)) and copolymer of CR-39/NIPAAm (TNF-1)) with high sensitivity becomes rough by the etching, while the pure CR-39 (BARYOTRAK) with low sensitivity keeps its original surface clarity even for the long etching.  相似文献   

12.
A technique based on the optical density (D) measurement of the etched track is useful for charged particles spectroscopy using SSNTD. It was shown that the stopping power of alpha particles in CR-39 is proportional to D. We measured the optical density and derived an expression to estimate the range of alpha particles in CR-39 detector as a function of the bulk etching rate and etching time. The relation between the etching time, track parameters (depth, radius) and D for different alpha particles energy and etching conditions were studied. A relation describing D as a function of track size is proposed.  相似文献   

13.
合肥光源BPM真空室位移监测系统   总被引:1,自引:1,他引:0       下载免费PDF全文
 合肥光源(HLS)电子储存环的束流水平轨道存在缓慢漂移现象,导致轨道水平漂移的主要原因是同步光热效应导致束流位置检测器(BPM)真空室水平移动。为抑制这种现象而研制的合肥光源BPM真空室位移监测系统,利用光栅位移传感器实时监测全环24个BPM真空室的位移,并将数据反馈至HLS控制系统,由控制系统对BPM的轨道测量值进行实时修正,从而提高了慢速轨道反馈系统有效性。  相似文献   

14.
A review was given for our recent studies on the latent tracks in CR-39 nuclear track detector. The radial size of track core has been determined through UV spectral measurements combined to the model of track overlapping and by AFM observations of slightly etched detectors. The track core radius was found to be about a few nano-meters and almost proportional to the cubic root of stopping power. As a control study, the etching properties of CR-39, irradiated by low-LET radiation, has been examined. The observed depth dependence and dose-rate dependence of the bulk etch rate of the irradiated CR-39 were explained that the damage formation process was governed by the reaction between the radiation induced radicals and the oxygen supplied from the air. This indicated that latent tracks in CR-39 are produced through local radiation induced oxidation process along the ion paths. Studies on vibration spectra, near-IR, FT-IR and Raman spectra, of CR-39 have also been carried out to estimate the chemical structure of the latent tracks. The creation of OH group in irradiated CR-39 has been confirmed.  相似文献   

15.
NRPB has operated a routine neutron personal dosimetry service based on the electrochemical etch of PADC elements since 1986. Since its inception it has used an automated reader based on a video camera and real time analysis. A new and more powerful replacement system has been developed using a commercially available photographic slide scanner. This permits a complete image of the dosemeter to be grabbed in a single scan, generating a 2592x3888 pixel file which is saved for subsequent analysis. This gives an effective pixel size of 10x10 μm with an image of the entire dosemeter in one field of view. Custom written software subsequently analyses the image to assess the number of etched pits on the dosemeter and read the detector identification number (code). Batch scanning of up to 40 detectors is also possible using an autofeed attachment. The system can be used for electrochemically etched tracks for neutron detectors and chemically etched tracks for radon detectors.  相似文献   

16.
In the current work, alpha particle spectroscopy is investigated experimentally by utilizing the over-etched track lengths in the CR-39 detector. CR-39 samples were exposed perpendicularly to alpha particles emitted from 241Am with an energy ranging from 0.5 to 5.5 MeV. CR-39 samples were etched in 6.25 N NaOH at (70±0.5)°C for different durations. The track diameter and track length were measured under an optical microscope. The results show that, the energy-over-etched track length calibration curve is monotonic, in other words, the over-etched track length is a monotonic function in alpha particle energy. On the other hand, the energy-diameter calibration curve is degenerated, i.e. alpha track diameter is non-monotonic function in alpha particle energy. These results suggest that the CR-39 detector could be used as a wide range alpha particles spectrometer using an energy-over-etched track length calibration curve.  相似文献   

17.
At the beginning of the etching process a constant track etch rate can be assumed. In deeper detector layers, however, the etch rate varies drastically along the particle trajectories. Consequently, the indirect determination of the track etch rate by measuring the etch pit diameters on the detector surface does not yield correct results. Therefore, a method for the direct measurement of the track etch rate as a function of the depth within the detector was developed. Applying this method, the relationship between the track etch rate and the energy loss in CR-39/PATRAS could be derived.  相似文献   

18.
The application of CR-39 as a fast neutron dosimeter, based on counting elastic recoil nuclei tracks of H, C and O nuclei in a geometrically matched pair of detectors, was studied. A computer simulation of the processes during the exposure of a detector pair to neutrons is presented. The energy and spatial distribution of the recoil nuclei was calculated with the MCNP 4B program package. On the basis of this distribution, a Monte-Carlo procedure for the generation of latent tracks in the CR-39 detectors was run. Additionally, a procedure for calculation of the chemical track etching for revealing the visible track parameters was performed to obtain the detector response.  相似文献   

19.
The effect of infrared radiation on the etching characteristics of CR-39 plastic track recorder has been studied. CR-39, which is commonly employed in cosmic rays studies is found to be affected by IR radiations. The changes in the bulk etch rate, in the track etch rate and in etching efficiency due to infrared radiation exposure of CR-39 are discussed on the basis of scission and cross linking during infrared exposure.  相似文献   

20.
A laboratory system for the calibration of track detectors and charcoal detectors used in monitoring of radon and its decay products/their aerosols in air, is proposed. The system consists of three main components: (i) the alpha exposure chambers, including alpha monitoring devices and the connection with the 226Ra radioactive source. The CR-39 track detectors are mounted in the monitoring devices pre-equipped or not with paper filter; (ii) the calibrated  226Ra source. Among the three tested sources: 222Rn, 226Ra+222Rn and 226Ra, the 226Ra source is considered the most appropriate radon source for our calibration system. It is kept into an airtight flat bottom flask, the radionuclide 226Ra being always in the radioactive equilibrium with their descendants. In the alpha exposure chambers, the source assures the radon at a constant rate; (iii) the ALFAUURASE program for the computation of radioactive accumulation of the alpha 226Ra descendants. For any initial mass of the parent, the amount and the activity of each alpha decay product and of all the decay products can be calculated by this computation program. Each component of the calibration system is described in the paper. The use of the system for the calibration of CR-39 track detectors in radon measurements is tested.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号