首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The purpose of the Water Framework Directive is to ensure the quality of the natural water across Europe. In this context, passive samplers have shown interesting capacities for the monitoring of contaminants in aqueous ecosystems. They allow the measurement of time-weighted average concentrations, overcoming many drawbacks of the spot-sampling techniques known to be expensive and time consuming. However, application of passive samplers such as polar organic chemical integrative samplers (POCIS) for the monitoring of hydrophilic contaminants requires calibration to define compound sampling rates; key parameters to deduce the pollutant water concentrations from the amounts of pollutants accumulated by the device. Unfortunately, sampling rates are influenced by a range of environmental factors; in that respect, a question remains: is it not evident to know to what extent the sampling rates obtained in laboratory experiments can be used in field conditions? The problem can be solved for hydrophobic samplers by using performance reference compounds (PRCs), and an ongoing challenge for POCIS is focused on the improvement of the quantitative aspect of this family of samplers. In this study, potential PRCs have been selected during a specific experiment and their performance was tested in the laboratory under two hydrodynamic conditions. Results revealed a good proportionality between elimination rates of PRCs and sampling rates of chemicals. Afterwards, the application of the approach under environmental conditions was assessed by deploying POCIS in the Arcachon Bay (France) where POCIS–PRC-derived water concentrations appear to be close to the simultaneous grab-sampling results.
Figure
Relationship between Irgarol sampling rate and DIA elimination rate  相似文献   

2.
This paper presents an optimization of the pharmaceutical Polar Organic Chemical Integrative Sampler (POCIS-200) under controlled laboratory conditions for the sampling of acidic (2,4-dichlorophenoxyacetic acid (2,4-D), acetochlor ethanesulfonic acid (ESA), acetochlor oxanilic acid, bentazon, dicamba, mesotrione, and metsulfuron) and polar (atrazine, diuron, and desisopropylatrazine) herbicides in water. Indeed, the conventional configuration of the POCIS-200 (46 cm2 exposure window, 200 mg of Oasis® hydrophilic lipophilic balance (HLB) receiving phase) is not appropriate for the sampling of very polar and acidic compounds because they rapidly reach a thermodynamic equilibrium with the Oasis HLB receiving phase. Thus, we investigated several ways to extend the initial linear accumulation. On the one hand, increasing the mass of sorbent to 600 mg resulted in sampling rates (R s s) twice as high as those observed with 200 mg (e.g., 287 vs. 157 mL day?1 for acetochlor ESA). Although detection limits could thereby be reduced, most acidic analytes followed a biphasic uptake, proscribing the use of the conventional first-order model and preventing us from estimating time-weighted average concentrations. On the other hand, reducing the exposure window (3.1 vs. 46 cm2) allowed linear accumulations of all analytes over 35 days, but R s s were dramatically reduced (e.g., 157 vs. 11 mL day?1 for acetochlor ESA). Otherwise, the observation of biphasic releases of performance reference compounds (PRC), though mirroring acidic herbicide biphasic uptake, might complicate the implementation of the PRC approach to correct for environmental exposure conditions.
Figure
POCIS and μPOCIS in river media  相似文献   

3.
Odorant binding protein (OBP) is a multi-functional scavenger for small hydrophobic molecules dissolved in the mucus lining the nasal epithelia of mammals, characterized by broad ligand binding specificity towards a large number of structurally unrelated natural and synthetic molecules of different chemical classes. Here, we demonstrate for the first time the application of OBP as the active element of an innovative filtering matrix for the removal of environmental pollutants such as triazine herbicides from water samples. The filtering device, obtained by coupling histidine-tagged bovine OBP to a nickel nitrilotriacetic acid (Ni-NTA) agarose resin, was characterized in terms of retention capacity for the herbicides atrazine, simazine, and propazine. Analysis of these herbicides at trace levels with solid-phase microextraction followed by gas chromatography–mass spectrometry using the selected ion monitoring mode proved the capabilities of the proposed device for the decontamination of surface and groundwater samples in the 0.2–2,300 μg/L concentration range, obtaining a reduction in the triazine content greater than 97 %, thus suggesting its possible use for the potabilization of water.
Figure
Tridimensional structure of bOBP with AMA inside the cavity  相似文献   

4.
A method for the simultaneous determination of six perfluoroalkyl compounds (perfluorooctanesulfonic acid (PFOS) and five perfluoroalkyl carboxylic acids), five phenolic compounds (nonylphenol (NP), bisphenol A (BPA), and methyl-, ethyl- and propylparabens), and the brominated flame retardant hexabromocyclododecane (HBCDD) in surface water and effluent wastewater has been developed. The selected pollutants include eight of the industrial pollutants (PFOS and derivatives, NP, and HBCDD) that could be regulated in surface water according to an European Union Directive proposal and four compounds of great concern because their estrogenicity (BPA and parabens). The method is based on solid-phase extraction and determination by high-performance liquid chromatography–triple quadrupole mass spectrometry in negative electrospray ionization mode. Method quantitation limits of NP, PFOS and derivatives, and HBCDD allow its application for routinely control of surface water according to the EU proposal of directive.
Figure
?  相似文献   

5.
The detection of volatile organic compounds is of great importance for assessing the quality of water. In this contribution, we describe a miniaturized stripping device that allows fast online detection of organic solvents in water. The core component is a glass microfluidic chip that facilitates the creation of an annular-flowing stream of water and nitrogen gas. Volatile compounds are transferred efficiently from the water into the gas phase along the microfluidic pathway at room temperature within less than 5 s. Before exiting the microchip, the liquid phase is separated from the enriched gas phase by incorporating side capillaries through which the hydrophilic water phase is withdrawn. The gas phase is conveniently collected at the outlet reservoir by tubing. Finally, a semiconductor gas sensor analyzes the concentration of (volatile) organic compounds in the nitrogen gas. The operation and use of the stripping device is demonstrated for the organic solvents THF, 1-propanol, toluene, ethylbenzene, benzaldehyde, and methanol. The mobile, inexpensive, and continuously operating system with liquid flow rates in the low range of microliters per minute can be connected to other detectors or implemented in chemical production line for process control.
Figure
We present a microfluidic device for highly efficient analytical stripping of organic solvents from water/solvent mixtures at room temperature  相似文献   

6.
Most of the precursors and/or degradation products related to the Chemical Weapons Convention (CWC) are polar. Identification of these molecules in environmental samples provides clues regarding the alleged usage and/or synthesis of the parent toxic chemicals. Such polar compounds need to be derivatized in order to analyze them by gas chromatography–mass spectrometry (GC–MS). In this study, we developed a new derivatizing reagent, para-tolyl isocyanate (PTI), for derivatization of polar CWC-related compounds. The PTI reagent selectively derivatizes the –OH and/or?SH functional groups with high efficiency, but does not react with carboxylic acid (?COOH) or phosphonic acid (?(O)P(OH)2) groups. The PTI derivatives of dialkyl aminoethanols, dialkyl aminoethanol-N-oxides, and 3-quinuclidinol were successfully eluted through GC, and their electron ionization (EI) mass spectra were distinct and provided the structure information by which the isomeric compounds can be easily distinguished. We also calculated the GC-retention index values that can be used for further confirmation of the target compounds. All the studied PTI derivatives can be analyzed by EI-MS with direct insertion probe and/or by direct electrospray ionization mass spectrometry (ESI-MS) together with the MS–MS data; both sets of data provide full structure information. The PTI reagent was found to be better in some respects than the conventional bistrimethylsilyl trifluoroacetamide (BSTFA), a trimethyl silylating reagent. The PTI reagent is commercially available, and the PTI derivatives are highly stable for months and are not sensitive to moisture. The applicability of the PTI derivatization for trace-level determination of the target CWC-related polar compounds in environmental matrices and in human plasma samples is also evaluated.
Fig. a
?  相似文献   

7.
Human biomonitoring (HBM) is a scientific technique that allows us to assess whether and to what extent environmental pollutants enter humans. We review here the current HBM efforts for organophosphate esters, emerging flame retardants, perfluoroalkyl substances, and phthalate esters. Use of some of these chemicals has already been banned or restricted; they are regularly detected in the environment, wildlife, and human matrices. Traditionally, blood and urine collection have been widely used as sampling methods. New non-invasive approaches (e.g., saliva, hair, nails) are emerging as valid alternatives since they offer advantages with respect to sampling, handling, and ethical aspects, while ensuring similar reliability and sensitivity. Nevertheless, the identification of biomarkers of exposure is often difficult because chemicals may be metabolized in the human body. For many of the above-mentioned compounds, the mechanisms of the favorable metabolization pathways have not been unraveled, but research on important metabolites that could be used as biomarkers of exposure is growing. This review summarizes the state of the art regarding human exposure to, (non-invasive) HBM of, and metabolism of major organophosphate esters, emerging flame retardants, perfluoroalkyl substances, and phthalate esters currently detected in the environment.
Figure
Human biomonitoring of emerging contaminants-non-invasive versus invasive matrices  相似文献   

8.
Hydrophilic interaction liquid chromatography (HILIC) has emerged in recent years as a valuable alternative to reversed-phase liquid chromatography in the analysis of polar compounds. Research in HILIC is divided into two directions: the assessment of the retention mechanism and retention behavior, and the development of HILIC methods. In this work, four polar neutral analytes (iohexol and its related compounds A, B, and C) were analyzed on two silica and two diol columns in HILIC mode with the aim to investigate thoroughly the retention mechanisms and retention behavior of polar neutral compounds on these four columns. The adsorption and partition contribution to the overall HILIC retention mechanism was investigated by fitting the retention data to linear (adsorption and partition) and nonlinear (mixed-retention and quadratic) theoretical models. On the other hand, the establishment of empirical second-order polynomial retention models on the basis of D-optimal design made possible the estimation of the simultaneous influence of several mobile-phase-related factors. Furthermore, these models were also used as the basis for the application of indirect modeling of the selectivity factor and a grid point search approach in order to achieve the optimal separation of analytes. After the optimization goals had been set, the grids were searched and the optimal conditions were identified. Finally, the optimized method was subjected to validation.
Figure
?  相似文献   

9.
Monitoring carnitine and acetylcarnitine levels in biological fluids is a powerful tool for diagnostic studies. Research has recently shown that the analysis of carnitine and related compounds in clinical samples can be accomplished by different analytical approaches. Because of the polar and ionic nature of the analytes and matrix complexity, accurate quantitation is a highly challenging task. Thus, sample processing factors, preparation/cleanup procedures, and chromatographic/ionization/detection parameters were evaluated. On the basis of the results obtained, a rapid, selective, sensitive method based on hydrophilic interaction liquid chromatography–tandem mass spectrometry for the analysis of carnitine and acetylcarnitine in serum and urine samples is proposed. The matrix effect was assessed. The proposed approach was validated, the limits of detection were in the nanomolar range, and carnitine and acetylcarnitine levels were found within the micromolar range in both types of sample.
Figure
Experimental workflow for the carnitine and acetylcarnitine determination in biological samples by HILIC-MS/MS  相似文献   

10.
We report on a surface molecular imprinting strategy for synthesizing core-shell particles whose shell is imprinted with chlorpyrifos (CPF). The particles were prepared by copolymerization of the methacryloyl groups on the surface of silica particles modified with 3-methacryloxypropyl trimethoxysilane a functional monomer and a cross-linking agent. The imprinted particles exhibit larger binding capacity, faster binding kinetics, and higher recognition selectivity for CPF. Combined with highly sensitive chemiluminescence assay, the method was applied to the determination of CPF with a detection limit of 0.92?nM which is about 2 orders of magnitude lower than that by conventional CL method. The method also displays repeatability for more than 200 times.
Figure
Schematic illustration of a surface molecular imprinting strategy for synthesizing core-shell particles with CPF-imprinted shells and the CL kinetics curves of MIP-based CL method for the determination of chlorpyrifos.  相似文献   

11.
We have prepared a hydrophilic molecularly imprinted polymer (MIP) for the hydrophobic compound bisphenol A (BPA) in aqueous solution using 3-acrylamido-N,N,N-trimethylpropan-1-aminium chloride (AMTC) as the functional monomer. Under redox-polymerization conditions, BPA forms an ion-pair with AMTC, which was confirmed by 1H-NMR titration. The imprinting effect in aqueous solution was evaluated by comparison of this material with the corresponding non-imprinted polymer (NIP) and with a control polymer (CP) bearing no AMTC. The MIP showed the highest activity among the three polymers, and the imprinting factors as calculated from the amount of BPA bound to the MIP divided by the amounts bound to NIP and CP, respectively, are 1.8 and 6.0. The MIP was selective for BPA in aqueous solution, while structurally related compounds are not recognized. Such a selectivity for a hydrophobic compound is rarely observed in aqueous medium because non-specific binding of BPA inevitably leads to hydrophobic interaction.
Figure
A hydrophilic molecularly imprinted polymer (MIP) for bisphenol A (BPA) recognition was prepared in aqueous solution. The obtained MIP (BPA-MIP) showed good selectivity under aqueous conditions  相似文献   

12.
An analytical method using high-performance liquid chromatography–tandem mass spectrometry was developed to determine internal concentrations of 34 test compounds such as pharmaceuticals and pesticides in zebrafish embryos (ZFE), among them, cimetidine, 2,4-dichlorophenoxyacetic acid, metoprolol, atropine and phenytoin. For qualification and quantification, multiple reaction monitoring mode was used. The linear range extends from 0.075 ng/mL for thiacloprid and metazachlor and 7.5 ng/mL for coniine and clofibrate to 250 ng/mL for many of the test compounds. Matrix effects were strongest for nicotine, but never exceeded ±20 % for any of the developmental stages of the ZFE. Method recoveries ranged from 90 to 110 % from an analysis of nine pooled ZFE. These findings together with the simple sample preparation mean this approach is suitable for the determination of internal concentrations from only nine individual ZFE in all life stages up to 96 h post-fertilization. Exemplarily, the time course of the internal concentrations of clofibric acid, metribuzin and benzocaine in ZFE was studied over 96 h, and three different patterns were distinguished, on the basis of the speed and extent of uptake and whether or not a steady state was reached. Decreasing internal concentrations may be due to metabolism in the ZFE.
Figure
Quantification of polar pollutants in different life stages of the zebrafish embryo by LC-MS/MS  相似文献   

13.
Nanotubular titania film was prepared in situ on titanium wire and was used as the fiber substrate for solid-phase microextraction (SPME) because of its high surface-to-volume ratio, easy preparation, and mechanical stability. Three different functional coatings, β-cyclodextrin (β-CD), β-cyclodextrin-co-poly(ethylenepropylene glycol) (β-CD/PEG), and polyethylene glycol (PEG)-based sorbents were chemically bonded to the nanostructured wire surface via sol-gel technology to further enhance the absorbing capability and extraction selectivity. Coupled to gas chromatography-flame ionic detection (GC-FID), the prepared SPME fibers were investigated using diverse compounds. The results indicated that the fibers showed good mechanical strength, excellent thermal stability, and wonderful capacity and selectivity to polar compounds, including polar aromatic compounds, alcohols, and ketones. Combining the superior hydrophilic property of a bonded functional molecule and the highly porous structure of a fiber coating, the prepared PEG-coated SPME fiber showed much higher adsorption affinity to ephedrine and methylephedrine than β-CD and β-CD/PEG fibers. The as-established PEG-coated SPME-GC analytical method provided excellent sensitivity (LODs, 0.004 and 0.001 ng mL–1 for ephedrine and methylephedrine, respectively) and better linear range (0.01–2 000 μg L?1). In addition, it has surprising repeatability and reproducibility. Finally, the present approach was used to analyze ephedrine and methylephedrine from real urine samples, and reliable results were obtained.
Figure
Preparation and application of sol-gel adsorbents/nanotublar tiatinia-coated SPME fibers  相似文献   

14.
Large polarizable n-alkanes (approximately C18 and larger), alcohols, and other nonpolar compounds can be detected as negative ions when sample solutions are injected directly into the sampling orifice of the atmospheric pressure interface of the time-of-flight mass spectrometer with the direct analysis in real time (DART) ion source operating in negative-ion mode. The mass spectra are dominated by peaks corresponding to [M + O2] ̄?. No fragmentation is observed, making this a very soft ionization technique for samples that are otherwise difficult to analyze by DART. Detection limits for cholesterol were determined to be in the low nanogram range.
Figure
?  相似文献   

15.
We present an effective solution for the problem of contrast enhancement in phase-contrast microangiography, with the specific objective of visualising small (<8 µm) vessels in tumor-related microangiogenesis. Different hydrophilic and hydrophobic contrast agents were explored in this context. We found that an emulsified version of the hydrophobic contrast agents Lipiodol® provides the best contrast and minimal distortion of the circulation and vessel structure. Such emulsions are reasonably biocompatible and, with sizes of 0?±?0.8 µm, sufficient to diffuse to the smallest vessel and still provide reasonable contrast. We also explored the use of Au nanoparticle colloids that could be used not only to enhance contrast but also for interesting applications in nanomedicine. Both the Lipiodol microemulsions and Au nanoparticle colloids can be conjugated with medicines or cell specific labeling agents and their small size can allow the study of the diffusion of contrast agents through the vessel leakage. This enables direct imaging of drug delivery which is important for cancer treatment.
Figure
  相似文献   

16.
A composite film made from a thiol-functionalized mesoporous molecular sieve and an ionic liquid is introduced for use in a voltammetric sensor for Cd(II). The electrode exhibits excellent sensitivity towards Cd(II) in showing a markedly increased stripping peak current. Following the optimization of the experimental parameters, a linear response is obtained in the concentration range from 29?nM to 0.87?mM of Cd(II). The detection limit is as low as 1.0?nM (at S/N?=?3) after an accumulation at ?1.1?V for 4?min. The method was successfully applied to determine Cd(II) in water samples. Features such as large electroactive area, fast electron transfer and low background current make this electrode a promising platform for fabricating reliable electrochemical sensors for various species, such as heavy metals and environmental pollutants.
Figure
Linear sweep voltammograms of 0.5 ??M Cd(II) in 0.1 M HAc-NaAc buffer (pH 5.5), 100 mV s?1 at: (a) bare GCE; (b) ILs film coated GCE; (c) P123-SH/ILs/GCE  相似文献   

17.
Conventional N-glycoproteome analysis usually applies C18 reversed-phase (RP) adsorbent for sample purification, which will lead to unavoidable sample loss due to the high hydrophilicity of N-glycopeptides. In this study, a porous graphitized carbon (PGC) absorbent was combined with a C18 adsorbent for N-glycopeptide purification in comprehensive N-glycoproteome analysis based on the hydrophobic and polar interactions between carbon and N-glycans. It was observed that the small hydrophilic N-glycopeptides that cannot retain onto C18 adsorbent can be captured by the graphitized carbon, while the large hydrophobic N-glycopeptides that cannot retain onto the graphitized carbon can be feasibly captured by the C18 adsorbent. Comparing with sample purification by using C18 adsorbent only, 28.5 % more N-glycopeptides were identified by combining both C18 and PGC adsorbents. The C18-PGC strategy was further applied for both sample purification and pre-fractionation of a complex protein sample from HeLa cell. After hydrophilic interaction chromatography enrichment, 1,484 unique N-glycopeptides with 1,759 unique N-glycosylation sites were finally identified.
Online Abstract Figure
The overlap of identified N-glycosylation sites by different SPE strategies  相似文献   

18.
A method using on-line solid-phase microextraction (SPME) on a carbowax-templated fiber followed by liquid chromatography (LC) with ultraviolet (UV) detection was developed for the determination of triclosan in environmental water samples. Along with triclosan, other selected phenolic compounds, bisphenol A, and acidic pharmaceuticals were studied. Previous SPME/LC or stir-bar sorptive extraction/LC-UV for polar analytes showed lack of sensitivity. In this study, the calculated octanol–water distribution coefficient (log D) values of the target analytes at different pH values were used to estimate polarity of the analytes. The lack of sensitivity observed in earlier studies is identified as a lack of desorption by strong polar–polar interactions between analyte and solid-phase. Calculated log D values were useful to understand or predict the interaction between analyte and solid phase. Under the optimized conditions, the method detection limit of selected analytes by using on-line SPME-LC-UV method ranged from 5 to 33 ng?L?1, except for very polar 3-chlorophenol and 2,4-dichlorophenol which was obscured in wastewater samples by an interfering substance. This level of detection represented a remarkable improvement over the conventional existing methods. The on-line SPME-LC-UV method, which did not require derivatization of analytes, was applied to the determination of TCS including phenolic compounds and acidic pharmaceuticals in tap water and river water and municipal wastewater samples.
Figure
Schematic diagram of the On-line solid-phase microextraction  相似文献   

19.
A hydrophobic-hydrophilic-hydrophobic pattern has been produced on the surface of a silicon substrate for selective enrichment, self-desalting, and matrix-free analysis of peptides in a single step. Upon sample application, the sample solution is first confined in a small area by a hydrophobic F-SAM outer area, after which salt contaminants and peptides are selectively enriched in the hydrophilic and hydrophobic areas, respectively. Simultaneously, matrix background noise is significantly reduced or eliminated because of immobilization of matrix molecules. As a result, the detection sensitivity is enhanced 20-fold compared with that obtained using the usual MALDI plate, and interference-free detection is achieved in the low m/z range. In addition, peptide ions can be identified unambiguously in the presence of NH4HCO3 (100 mM), urea (1 M), and NaCl (1 M). When the device was applied to the analysis of BSA digests, the peptide recovery and protein identification confidence were greatly improved.
Figure
?  相似文献   

20.
Surface enhanced Raman spectroscopy (SERS) has emerged as one of the most promising analytical tools in recent years. Due to advantageous features such as sensitivity, specificity, ease of operation and rapidity, SERS is particularly well suited for environmental analysis. We summarize here some considerations with respect to the detection of pollutants by SERS and provide an overview on recent achievements in the determination of organic pollutants, heavy metal ions, and pathogens. Following an introduction into the topic and considering aspects of sensitivity, selectivity, reproducibility and portability, we are summarizing applications of SERS in the detection of pollutants, with sections on organic pollutants (pesticides, PAHs and PCBs, explosives), on heavy metal ions, and on pathogens. In addition, we discuss current challenges and give an outlook on applications of SERS in environmental analysis. Contains 174 references.
Figure
The application of surface enhanced Raman spectroscopy (SERS) for the detection of environmental pollutants.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号