首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new solid phase extraction method based on aptamers, an oligosorbent, was developed and applied to the determination of ochratoxin A (OTA) from red wine. Two solid supports were chosen to immobilize OTA aptamer by covalent binding (cyanogen bromide-activated sepharose) or noncovalent binding (streptavidin-activated agarose). The resulting oligosorbents were evaluated in terms of retention, selectivity, and capacity. To assess the selectivity of the resulting oligosorbents, control supports made only of a solid support without immobilized aptamers were simultaneously studied. After optimization of the selective extraction procedure, extraction recoveries close to 100% were obtained on both materials. No retention was observed on the control supports. A similar capacity was also found for both oligosorbents. However, the immobilization by covalent bonding appeared more robust for the determination of OTA in the wine. A conventional sorbent and an immunoaffinity column were also applied to the determination of OTA in red wine to compare the potential of the various approaches for the treatment of such complex samples.  相似文献   

2.
Madru B  Chapuis-Hugon F  Pichon V 《Talanta》2011,85(1):616-624
A new kind of selective sorbent based on the use of aptamers and dedicated to the selective solid phase extraction was developed. Cocaine aptamer was chosen as model aptamer to demonstrate the feasibility of this material and to provide a complete evaluation of the synthesized sorbent. The effect of different parameters such as the nature of the immobilisation support (silica, agarose), the type of immobilisation (covalent or non-covalent) and the length of the spacer arm (C6 or C12) were studied. Therefore, various oligosorbents based on different immobilisation strategies were synthesized and characterised by estimating the extraction recovery and the capacity of cocaine and the binding efficiency of aptamers. Control supports without immobilised aptamers were simultaneously studied in parallel to assess the selectivity brought by the oligosorbents. The oligosorbent based on CNBr-activated sepharose showed the best performances with an extraction recovery for cocaine of 90% while 6% was obtained on the control sorbent. The high selectivity brought by the oligosorbent was then illustrated by applying the oligoextraction followed by LC/MS analysis to a post-mortem blood (cocaine overdose). Results were compared to those resulting from a conventional protein precipitation procedure. The presence of co-extracted interfering compounds was strongly reduced with the treatment by oligoextraction. A limit of quantification of 0.5 ng/mL was obtained that is largely lower than the concentration found after a single intake of cocaine.  相似文献   

3.
Wu X  Hu J  Zhu B  Lu L  Huang X  Pang D 《Journal of chromatography. A》2011,1218(41):7341-7346
A sorbent based on the aptamer for ochratoxin A was immobilized onto magnetic nanospheres (MNS) and used to develop a magnetic solid-phase extraction procedure to clean up food samples in conjunction with high-performance liquid chromatography separation and fluorescence detection. Specific retention of ochratoxin A by the sorbent was demonstrated, and the capacity of the MNS-aptamer sorbent was determined. The efficacy of this new approach was successfully evaluated through comparison with solid-phase extraction on commercial C18 cartridge. Several different food samples fortified in the range of with 2.5-50 μg/kg yielded mean recoveries from 67% to 90%, respectively. Finally, this oligosorbent was applied to the selective extraction of ochratoxin A from unfortified food samples.  相似文献   

4.
We explored a fluorescent strategy for sensing ochratoxin A (OTA) by using a single fluorophore-labeled aptamer for detection of OTA. This method relied on the change of the fluorescence intensity of the labeled dye induced by the specific binding of the fluorescent aptamer to OTA. Different fluorescein labeling sites of aptamers were screened, including the internal thymine bases, 3′-end, and 5′-end of the aptamer, and the effect of the labeling on the aptamer affinity was investigated. Some fluorophore-labeled aptamers showed a signal-on or signal-off response. With the fluorescent aptamer switch, simple, rapid, and selective sensing of OTA at nanomolar concentrations was achieved. OTA spiked in diluted red wine could be detected, showing the feasibility of the fluorescent aptamer for a complex matrix. This method shows potential for designing aptamer sensors for other targets.
Figure
A simple fluorescent approach for OTA sensing is achieved by using single fluorophore-labeled aptamer. A fluorophore is attached on one site of the aptamer. The affinity binding of OTA induces the alteration of fluorescence properties of the labeled fluorophore as the consequence of the conformation change of the aptamer. OTA can be detected by measuring the change of fluorescence signals of the labeled dye  相似文献   

5.
《Analytical letters》2012,45(13):2452-2464
Abstract

A high-performance liquid chromatography method for determination of ochratoxin A (OTA) in human blood serum has been validated. A liquid-liquid partition, solid-phase extraction and immunoaffinity cleanup was applied for OTA extraction from 0.5 mL of serum. Significant correlation (r = 0.998) was found over the range from 0.1 to 8 ng/mL, with better performance in terms of accuracy, precision, and selectivity. Validation was made with human serum spiked at two levels, 0.5 and 2.0 ng/mL,26 and natural contaminated serum. Average recoveries of OTA using different extraction methods ranged from 58.48 ± 4.56 to 94.85 ± 3.52%. Immunoaffinity cleanup showed a better recovery rate, with a lower detection limit validated at 0.1 ng/mL. The cited method can be used as a rapid and noninvasive tool to assess human and animal exposure to OTA.  相似文献   

6.
We describe a simple, environmentally friendly and selective technique for the determination of ochratoxin A (OTA) in urine. It involves (a) the use of a molecularly imprinted polymer as a sorbent in micro-solid-phase extraction in which the sorbent is contained in a propylene membrane envelope, and (b) separation and detection by capillary electrophoresis (CE). Under optimized conditions, response is linear in the range between 50 and 300 ng mL?1 (with a correlation coefficient of 0.9989), relative standard deviations range from 4 to 8 %, the detection limit for OTA in urine is 11.2 ng mL?1 (with a quantification limits of 32.5 ng mL?1) which is lower than those of previously reported methods for solid-phase extraction combined with CE. The recoveries of OTA from urine spiked at levels of 50, 150 and 300 ng mL?1 ranged from 93 to 97 %.
Figure
?  相似文献   

7.
A simple, reliable, and low‐cost method based on molecularly imprinted polymer as a selective sorbent of SPE was proposed for the determination of ochratoxin A (OTA) in beer, red wine, and grape juice by HPLC coupled with fluorescence detection (HPLC‐FLD). Samples were diluted with water and cleaned up with an AFFINIMIP® SPE OTA column. After washing and eluting, the analyte was analyzed by HPLC‐FLD. Under the optimized conditions, LOD and LOQ for OTA were 0.025 and 0.08 ng/mL, respectively. The recoveries of OTA from beer, red wine, and grape spiked at 0.1, 2, and 5 ng/mL ranged from 91.6 to 101.7%. Furthermore, after a simple regenerated procedure, the molecularly imprinted polymer based SPE column could be reused at least 14 times to achieve more than 80% recoveries of OTA in real samples. The developed method was applied to the detection of 30 beer, red wine, and grape juice samples and only four samples were contaminated by OTA with levels below the legal limits.  相似文献   

8.
研制了一种基于液晶取向改变的非标记液晶型免疫传感器,并用于检测赭曲霉素A(0TA).采用戊二醛交联法将OTA同定在由自组装膜修饰的玻璃肇底表面.自组装膜能诱导液晶分子垂直排列,而连接OTA抗体后则扰乱了液晶分子取向的有序排列,导致液晶分子在化学敏感膜表面的取向发生变化,使光学信号的亮度及色彩发生变化,以此实现对OTA的...  相似文献   

9.
The authors describe a fluorometric assay for ochratoxin A (OTA) that is based on the use of graphene oxide and RNase H-aided amplification. On addition of OTA, cAPT is replaced from the APT/cAPT hybridization complex and then hybridizes with RNA labeled with a fluorophore at the 5′-end. Eventually, the fluorophore is released by RNase H cleavage. As the concentration of OTA increases, more cAPTs are displaced, this leading to fluorescence enhancement (best measured at excitation/emission wavelengths of 495/515 nm). This RNase H-assisted cycle response results in strong signal amplification. The limit of detection, calculated on the basis of a signal to noise ratio of 3, is 0.08 ng·mL?1. Response is linear in the 0.08–200 ng·mL?1 OTA concentration range. The method is highly selective for OTA over ochratoxin B and aflatoxin B1. It was applied to the determination of OTA in red wine samples spiked at levels of 1, 7, and 50 ng·mL?1, and the recoveries ranged from 90.9 to 112%.
Graphical abstract Schematic of a novel fluorometric aptasensor for ochratoxin A based on the use of graphene oxide and RNase H-aided amplification.
  相似文献   

10.
《Analytical letters》2012,45(5):757-766
Abstract

A high‐performance liquid chromatography (HPLC) method has been developed for the determination of ochratoxin A (OTA) in human blood serum. Samples were purified on a C18 solid phase extraction column. The developed method required a relatively low serum volume (0.5 ml). Significant correlation (r of 0.998) was found over the range from 0.10 to 8 ng/ml, with a detection limit of 0.1 ng/ml and better performance in terms of precision and accuracy. Mean recoveries at 0.5 and 2 ng/ml were respectively 69.7±1.2 and 71.9±2.8%. This method was used as a rapid and noninvasive tool to assess human exposure to OTA. Among 40 analyzed serum samples, 27.5% were found to contain OTA with levels going from 0.1 to 11.98 ng/ml with a mean concentration of 0.73±2.35 ng/ml.  相似文献   

11.
This article describes a simple and homogeneous fluorescent aptasensor for the detection of ochratoxin A (OTA). With its high specificity and simplicity; RecJf exonuclease is used to cleave DNA strand of the FAM-aptamer/OTA complex and realize target recycling signal amplification. In order to avoid the loss of reaction system, magnetic beads (MBs) are added only once at the last experimental step. This proposed fluorescent aptasensor showed the higher sensitivity in the range of 0.1–100 ng/mL with LOD of 0.056 ng/mL, and the good selectivity against other interfering toxins. The feasibility of the prepared aptasensor was studied by detecting OTA in spiked liquor and cereal samples. The obtained average recoveries ranged from 92% to 115%. This study provides a promising application with convenience and rapidness in the aptasensor fabrication for food safety analysis.  相似文献   

12.
The aim of this work was to develop a method for the clean-up of a mycotoxin, i.e. Ochratoxin A (OTA), from cereal extracts employing a new molecularly imprinted polymer (MIP) as selective sorbent for solid-phase extraction (SPE) and to compare with an immunoaffinity column. A first series of experiments was carried out in pure solvents to estimate the potential of the imprinted sorbent in terms of selectivity studying the retention of OTA on the MIP and on a non-imprinted polymer using conventional crushed monolith. The selectivity of the MIP was also checked by its application to wheat extracts. Then, after this feasibility study, two different formats of MIP: crushed monolith and micro-beads were evaluated and compared. Therefore an optimization procedure was applied to the selective extraction from wheat using the MIP beads. The whole procedure was validated by applying it to wheat extract spiked by OTA at different concentration levels and then to a certified contaminated wheat sample. Recoveries close to 100% were obtained. The high selectivity brought by the MIP was compared to the selectivity by an immunoaffinity cartridge for the clean-up of the same wheat sample. The study of capacity of both showed a significant higher capacity of the MIP.  相似文献   

13.
Comparison of methods for the determination of ochratoxin A in wine   总被引:2,自引:0,他引:2  
Different analytical methods for the determination of ochratoxin A (OTA) in wine have been compared. Sample clean-up was based on solid-phase extraction (SPE) with (i) immunoaffinity or (ii) RP-18 sorbent materials applying different experimental protocols. The detection of OTA was accomplished with high-performance liquid chromatography (HPLC) combined either with electrospray ionisation (ESI) tandem mass spectrometry (MS-MS) or fluorescence detection (FL). Comparative method evaluation was based on the investigation of 18 naturally contaminated red wine samples originating from different European countries. The analytical results are discussed in view of the respective method validation data and the corresponding experimental protocols. In general, analytical data obtained with RP-18 SPE combined with LC-MS-MS detection and immunoaffinity extraction combined with FL offered comparable good results in the sub-ppb concentration level indicating that high selectivity of either the sample clean-up or, alternatively the detection system are equally well-suited to guarantee an accurate OTA analysis in wine.  相似文献   

14.
An electrochemical aptasensor for ochratoxin A (OTA) detection has been developed on the base of a gold electrode covered with electropolymerized neutral red and silver nanoparticles obtained by chemical reduction with macrocyclic ligands bearing catechol fragments. Thiolated aptamers against OTA were covalently attached to silver nanoparticles via Ag? S bonding. The interaction with OTA induced the conformational switch of the aptamer, which caused increase of the charge transfer resistance measured by EIS in the presence of ferricyanide ions. The LOD achieved (0.05 nM) was comparable to other electrochemical aptasensors employing sophisticated assembling technique and enzyme amplification of the signal. The aptasensor was validated in spiked beer samples. The recovery of the OTA determination was found to be 66.3±14.1 % for light beer and 64.3±1.8 % for dark beer.  相似文献   

15.
By taking advantage of the intrinsic fluorescence of ochratoxin A (OTA), we present a fluorescence anisotropy approach for rapid analysis of the interactions between OTA and aptamers. The specific binding of OTA with a 36-mer aptamer can induce increased fluorescence anisotropy (FA) of OTA as the result of the freedom restriction of OTA and the increase of molecular volume, and the maximum FA change is about 0.160. This FA approach enables an easy way to investigate the effects of buffer compositions like metal ions on the affinity binding. FA analysis shows the interaction between OTA and aptamer is greatly enhanced by the simultaneous presence of Ca2+ and Na+, while the binding affinity of aptamer decreases more than 18-fold when only Ca2+ exists, and the binding is completely lost when Ca2+ is absent. Crucial region of the aptamer for binding can be mapped through FA analysis and aptamer mutation. The demonstrated FA approach maintains the advantages of FA in simplicity, rapidity, and robustness. This investigation will help the development of aptamer-based assays for OTA detection in optimizing the binding conditions, modification of aptamers, and rational design.
Figure
The free ochratoxin A (OTA) molecule tumbles rapidly and shows low fluorescence anisotropy (FA), while the bound OTA by the aptamer has increased molecular volume and restricted freedom, showing enhanced FA. FA analysis allows screening the interaction between OTA and aptamer  相似文献   

16.
Extraction techniques are surface-dependent processes since their kinetic directly depends on the contact area between the sample and the extractant phase. The dispersion of the extractant (liquid or solid) increases this area improving the extraction efficiency. In this article, the dispersion of a nanostructured sorbent at the very low milligram level is achieved by effervescence thanks to the in situ generation of carbon dioxide. For this purpose, a special tablet containing the effervescence precursors (sodium carbonate as carbon dioxide source and sodium dihydrogen phosphate as proton donor) and the sorbent [multiwalled carbon nanotubes (MWCNTs)] is prepared. All the microextraction steps take place in a glass beaker containing 100 mL of the sample. After the extraction, the MWCNTs, enriched with the extracted analytes, are recovered by vacuum filtration. Methanol was selected to elute the retained analytes. The extraction mode is optimized and characterized using the determination of nine herbicides in water samples as model analytical problem. The absolute recoveries of the analytes were in the range 48–76 %, while relative recoveries were close to 100 % in all cases. These values permit the determination of these analytes at the low microgram per liter range with good precision (relative standard deviations lower than 9.3 %) using ultra performance liquid chromatography (UPLC) combined with ultraviolet detection (UV).  相似文献   

17.
The analytical performances of a novel DNA-ligand system using the time-resolved fluorescence (TRF) response of ochratoxin A (OTA)-terbium-DNA aptamer interaction were tested for the quantitative determination of OTA in wheat. Wheat was extracted with acetonitrile/water (60:40, v/v) followed by clean-up through affinity columns containing a DNA-aptamer-based oligosorbent. Then, OTA was detected by TRF spectroscopy after reaction with a terbium fluorescent solution containing the DNA-aptamer probe. The entire procedure was performed in less than 30 min, including sample preparation, and allowed analysis of several samples simultaneously with a 96-well microplate reader. The average recovery from samples spiked with 2.5-25 μg kg(-1) OTA was 77%, with a relative standard deviation lower than 6% and a quantification limit of 0.5 μg kg(-1). Comparative analyses of 29 naturally contaminated (up to 14 μg kg(-1)) wheat samples using the aptamer-affinity column/TRF method or the immunoaffinity column/high-performance liquid chromatography method showed good correlation (r = 0.985) in the range tested. The trueness of the aptamer-based method was additionally assessed by analysis of two quality control wheat materials for OTA. The DNA-ligand system is innovative, simple and rapid, and can be used to screen large quantities of samples for OTA contamination at levels below the EU regulatory limit with analytical performances satisfying EU criteria for method acceptability.  相似文献   

18.
《Analytical letters》2012,45(10):1979-1991
Abstract

A piezoelectric immunosensor based on a competitive format was developed for determination of ochratoxin A (OTA) concentration. Surface modifications via two self‐assembled monolayers (SAMs) were investigated respectively and a better result was obtained with the SAM of 16‐mercaptohexadecanoic acid (16‐MHDA). The quartz crystal microbalance (QCM)‐based immunosensor was fabricated by immobilizing anti‐OTA antibodies onto the surface of the 16‐MHDA‐modified electrode, and allowing competition between free OTA and that conjugated with BSA to occur. The assay exhibited a working range of 50–1000 ng/mL and a detection limit of 16.1 ng/mL. Studies of interference and matrix effects were performed to evaluate the feasibility of the developed immunosensor for the direct analysis of OTA in real samples. Recoveries were conducted at 50, 200, and 1000 ng/g and were determined to be in the range of 142%–76%. The OTA assay is specific. No cross‐reactivates were observed with citrinin.  相似文献   

19.
A rapid method was developed for the determination of pentachloronitrobenzene (PCNB) and its metabolites pentachloroaniline, pentachlorothioanisole residues in ginseng. Extraction and clean-up were carried out in a single step and analysis was accomplished by gas chromatography–mass spectrometry with multiple reaction monitoring. The main parameters affecting extraction yield and selectivity, such as type and amount of dispersant material, clean-up co-sorbent and extraction solvent were evaluated. The best results were obtained using 1 g ginseng, 2 g florisil as dispersant sorbent, 0.5 g neutral alumina as clean-up co-sorbent, and subsequent extraction with 10 mL acetone–n-hexane (5:5, v/v) with assisted sonication and repeated with another 5 mL of the same solvent mixture. The method was validated by analysis of ginseng samples fortified at different concentration levels (0.01–0.10 mg kg?1). Average recoveries (n = 5) ranged from 85 to 95% with relative standard deviation between 2.5 and 11.2%. Spiked blank samples were used as standards to counteract the matrix effect observed in the chromatographic determination. The detection limits ranged from 0.2 to 0.9 µg kg?1 in ginseng. The method was applied to the analysis of PCNB and its metabolite residues in commercial ginseng samples.  相似文献   

20.
The article describes an aptamer affinity column for selective solid-phase extraction of aflatoxin B2 (AFB2). Amino-modified aptamer against AFB2 was immobilized on CNBr-activated Sepharose through a covalent bond. The effects of oligosorbents based on 3′- or 5′-amino-modified sequences with a C6 or a C7 spacer arm were evaluated by UV spectroscopy at 260 nm. The extraction recovery was evaluated by HPLC with fluorometric detection. The extraction of AFB2 was optimized. Under the optimum conditions, the aptamer affinity column has a linear response to AFB2 in the range of 0.5–80 ng, with a capacity of 84.6 ng. Control supports without immobilized aptamers and a nonspecific oligosorbent immobilized with a negative control oligonucleotide were studied in order to demonstrate selectivity. The method was tested with spiked peanut sample (0.5–50 μg·kg?1 AFB2) and gave average recoveries of 80.9% and a mean relative standard deviation of 1.9%. The limit of detection is 25 pg·mL?1. This is much lower than the maximum residue limits suggested by the European Union. The columns can be re-used up to five times without any loss of performance. The oligosorbent was also applied to clean-up of AFB2 from peanut sample extracts before HPLC analysis. Results were further confirmed by ultra-fast liquid chromatography with tandem mass spectrometry. Conceivably, the method may also be applied to other samples, such as food, agricultural products, and traditional Chinese medicines.
Graphical abstract Schematic illustration of the fabrication procedures of aptamer affinity column, AAC (a), its principle of aptamer bound to aflatoxin B2 (b) and the obtained AAC (c).
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号