首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 468 毫秒
1.
D Zheng  SK Vashist  K Al-Rubeaan  JH Luong  FS Sheu 《The Analyst》2012,137(16):3800-3805
A rapid and simple procedure was developed for the preparation of a highly stable and leach-proof glucose oxidase (GOx)-bound glassy carbon electrode (GCE). Crosslinked GOx via glutaraldehyde was drop-cast on a KOH-pretreated GCE followed by drop-casting of 3-aminopropyltriethoxysilane (APTES) to form a stable bioactive layer. At -0.45 V, the biosensor exhibited a wide dynamic detection range of 0.5-48 mM for commercial glucose and 1.3-28.2 mM for Sugar-Chex blood glucose linearity standards. Several endogenous electroactive substances and drug metabolites commonly found in blood were tested and provoked no signal response. To our knowledge, the developed procedure is the most rapid method for preparing a glucose biosensor. The biosensor suffered no biofouling after 7 days of immersion in Sugar-Chex blood glucose. With excellent production reproducibility, GOx-bound electrodes stored dry at room temperature retained their initial activity after several weeks.  相似文献   

2.
A non-enzymatic impedimetric glucose sensor was fabricated based on the adsorption of gold nanoparticles (GNPs) onto conductive polyaniline (PANI)-modified glassy carbon electrode (GCE). The modified electrode (GCE/PANI/GNPs) was characterized by using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and scanning electron microscopy (SEM). The determination of glucose concentration was based on the measurement of EIS with the mediation of electron transfer by ferricyanide ([Fe(CN)6]3?). The [Fe(CN)6]3? is reduced to ferrocyanide ([Fe(CN)6]4?), which in turn is oxidized at GCE/PANI/GNPs. An increase in the glucose concentration results in an increase in the diffusion current density of the [Fe(CN)6]4? oxidation, which corresponds to a decrease in the faradaic charge transfer resistance (R ct). A wide linear concentration range from 0.3 to 10 mM with a lower detection limit of 0.1 mM for glucose was obtained. The proposed sensor shows high sensitivity, good reproducibility, and stability. In addition, the sensor exhibits no interference from common interfering substances such as ascorbic acid, acetaminophen, and uric acid.  相似文献   

3.
A novel and simple glucose sensor based on layer-by-layer (LBL) assembly of Cu and MnO2 nanoparticles on the glassy carbon electrode (Cu/MnO2/GCE) was constructed. The morphology and composition of the Cu and Cu/MnO2 on the electrode surface were observed by scanning electron microscopy and X-ray diffraction. Electrochemical experiments showed that the proposed Cu/MnO2/GCE exhibited excellent electrocatalytic properties to glucose. The oxidation peak currents of glucose on the Cu/MnO2/GCE were linearly related to glucose concentration in a wider linearity range from 0.25???M to 1.02?mM with a correlation coefficient of 0.9977. The sensitivity and detection limit was 26.96???A?mM?1 and 0.1???M (S/N?=?3), respectively. The Cu/MnO2 nanocomposite-modified electrode presented attractive features such as high sensitivity, stability, reproducibility, and interference-free property. The applicability of the proposed method to the determination of glucose in serum samples was demonstrated with satisfactory results.  相似文献   

4.
X Yang  J Bai  Y Wang  X Jiang  X He 《The Analyst》2012,137(18):4362-4367
Silver nanowires synthesized through a polyol process using polyvinylpyrrolidone as protection (PVP-AgNWs) were used as a new electrode material for constructing a sensor. Hydrogen peroxide (H(2)O(2)) and glucose were used as analytes to demonstrate the sensor performance of the PVP-AgNWs. It is found that the PVP-AgNWs-modified glassy carbon electrode (PVP-AgNWs/GCE) exhibits remarkable catalytic performance toward H(2)O(2) reduction. This sensor has a fast amperometric response time of less than 2 s and the catalytic current is linear over the concentration of H(2)O(2) ranging from 20 μM to 3.62 mM (R = 0.998) with a detection limit of 2.3 μM estimated on a signal-to-noise ratio of 3. A glucose biosensor was constructed by immobilizing glucose oxidase (GOD) onto the surface of the PVP-AgNWs/GCE. The resultant glucose biosensor can be used for glucose detection in human blood serum with a sensitivity of 15.86 μA mM(-1) cm(-2) and good selectivity and stability.  相似文献   

5.
The combined atomic force-electrochemical microscopy (AFM-SECM) technique was used in aqueous solution to determine both the static and dynamical properties of nanometer-thick monolayers of poly(ethylene glycol) (PEG) chains end-grafted to a gold substrate surface. Approach of a microelectrode tip from a redox end-labeled PEG layer triggered a tip-to-substrate cycling motion of the chains' free ends as a result of the redox heads' oxidation at the tip and re-reduction at the substrate surface. As few as approximately 200 chains at a time could be addressed in such a way. Quantitative analysis of the data, in the light of a simple model of elastic bounded diffusion SECM positive feedback, gave access to the end-tethered polymer layer thickness and the end-to-end diffusion coefficient of the chains. The thickness of the grafted PEG layer was shown to increase with the chain surface coverage, while the end-to-end diffusion coefficient was found to be constant and close to the one predicted by Rouse dynamics. At close tip-substrate separation, slowing of the chains' motion, as a consequence of their vertical confinement within the tip-substrate gap, was observed and quantitatively modeled.  相似文献   

6.
A novel glucose biosensor was fabricated by immobilizing glucose oxidase (GOx) on Ag nanoparticles-decorated multiwalled carbon nanotube (AgNP-MWNT) modified glass carbon electrode (GCE). The AgNP-MWNT composite membrane showed an improving biocompatibility for GOx immobilization and an enhancing electrocatalytic activity toward reduction of oxygen due to decoration of AgNPs on MWNT surfaces. The AgNPs also accelerated the direct electron transfer between redox-active site of GOx and GCE surface because of their excellent conductivity and large capacity for protein loading, leading to direct electrochemistry of GOx. The glucose biosensor of this work showed a lower limit of detection of 0.01 mM (S/N?=?3) and a wide linear range from 0.025 to 1.0 mM, indicating an excellent analytical performance of the obtained biosensor to glucose detection. The resulting biosensor exhibits good stability and excellent reproducibility. Such bionanocomposite provides us good candidate material for fabrication of biosensors based on direct electrochemistry of immobilized enzymes.  相似文献   

7.
《Electroanalysis》2018,30(9):2044-2052
Acid functionalized multi‐walled carbon nanotubes (f‐MWCNTs) were decorated with Au and Fe2O3 nanoparticles (FeONPs) and deposited on glassy carbon electrode (GCE). The resulting hybrid Au/Fe2O3/f‐MWCNTs/GCE electrode and the one further modified by glucose oxidase were compared for detection of glucose. FeONPs and Au were deposited on the f‐MWCNTs by sonication‐assisted precipitation and deposition‐precipitation methods, respectively. The morphology and structure of the samples were characterized by transmission electron microscopy, scanning electron microscopy, X‐ray diffraction and Raman spectroscopy. A uniform distribution of FeONPs with an average size of 5 nm increased the surface area of functionalized nanotubes from 39 to 50 m2/g. The electrocatalytic glucose detection on the modified electrodes was evaluated using cyclic voltammetry and chronoamperometry in 0.1 M phosphate buffer solution at pH 7.0. The non‐enzymatic and enzymatic electrodes show sensitivity of 512.4 and 921.4 mA/mM.cm2 and detection limit of 1.7 and 0.9 mM, respectively. The enzymatic and enzymeless electrodes retained more than 70 % and 80 % of their cathodic faradic current after 70 days, respectively. The sensing mechanism of the non‐enzymatic biosensor is described through the reaction of glucose with iron (III) ions, while in the case of enzymatic electrode, glucose is oxidized by glucose oxidase.  相似文献   

8.
Present study describes the synthesis of mixed oxide films of manganese and vanadium by electrochemical pulsed deposition technique on a glassy carbon electrode (GCE) modified with multiwall carbon nanotubes (MWCNT). The film was further decorated with gold nanoparticles to enhance the reduction signal of dissolved oxygen in pH 5.17 acetate buffer solution. All of the electrochemical synthesized modified electrodes have been characterized with Scanning electron microscopy(SEM), High‐resolution transmission electron microscopy (HRTEM), X‐Ray photoelectron spectroscopy (XPS), X‐Ray diffraction (XRD) techniques. The electrode obtained (AuNPs/MnOx?VOx/CNT/GCE) was utilized as a platform for glucose biosensor where the glucose oxidase enzyme was immobilized on the composite film with the aid of chitosan and an ionic liquid. The electrochemical performance of the biosensor was investigated by cyclic voltammetry and the relative parameters have been optimized by amperometric measurements in pH 5.17 acetate buffer solution. The developed biosensor exhibited a linear range for glucose between 0.1–1.0 mM and the limit of detection was calculated as 0.02 mM.  相似文献   

9.
《Electroanalysis》2017,29(3):696-701
Three non‐covalent metallotetraphenylporphyrin/fullerene (MTPPS4 (M=Zn2+, Fe2+, Co2+)/C60) nanocomposites were prepared by π‐π molecular interaction and characterized by scanning electron microscopy and UV‐Vis absorption spectroscopy. Electrocatalytic studies indicated that the MTPPS4/C60 nanocomposites which were embedded in TOAB film on the glassy carbon electrode (GCE) (TOAB/MTPPS4/C60/GCE) exhibited a high electrocatalytic activity for H2O2. MTPPS4 enhanced the electrocatalytic ability of C60 in the increasing order of TOAB/ZnTPPS4/C60/GCE, TOAB/FeTPPS4/C60/GCE and TOAB/CoTPPS4/C60/GCE. The measurement with the differential pulse voltammetry (DPV) exhibited that there is a well‐defined linear relationship between the reduction currents and H2O2 concentrations in the range from 0.3 to 1.0 mM, with the detection limit of 0.07 mM at the TOAB/ZnTPPS4/C60/GCE electrode, of 0.08 mM at the TOAB/FeTPPS4/C60/GCE electrode, of 0.04 mM at the TOAB/CoTPPS4/C60/GCE electrode, respectively. The biosensors showed a good anti‐interfering ability towards glucose, ascorbic acid and L‐cysteine and a high potential practicality.  相似文献   

10.
A novel recessed electrode is reported for amperometric detection of hydrogen peroxide and via glucose oxidase for the detection of glucose. The electrode utilised electrodeposited platinum over a gold wire surface, which proved to be an effective peroxide-detecting surface. Compared with a traditional exposed electrode surface, the recessed tip facilitated an extended linear range for glucose from 4 to over 14 mM. Bio-fouling, as assessed by exposure to bovine serum albumin, was also significantly reduced. Though response time at the recess was increased, it was within an acceptable range for physiological monitoring. Moreover, the recess enabled precise measurement of the hydrogen peroxide diffusion coefficient; this was based on a bipartite expression for the transient amperometric current at the recessed structure following a step change in ambient hydrogen peroxide concentration. An important aspect of the diffusion measurement was the curve fitting routine used to map on to the theoretical response curve.  相似文献   

11.
《Electroanalysis》2017,29(5):1368-1376
In this work, a photoamperometric glucose biosensor based on glucose oxidase (GODx) was developed in flow injection analysis (FIA) system using ZnS‐CdS quantum dot (QD) modified multiwalled carbon nanotube/glassy carbon electrode (ZnS‐CdS/MWCNT/GCE). Cyclic voltammograms of the proposed electrode (GODx/ZnS‐CdS/MWCNT/GCE) showed a pair of well‐defined reversible redox peak attributing that direct electron transfer between the protein and electrode. The current of the reduction peak became more cathodic in the presence of O2 due to the electrocatalytic activity of the electrode towards the reduction of dissolved O2, but reduction current shifted to a less negative value upon addition of glucose in the solution. The obtained CV currents were affected by the irradiation of the electrode surface. Thus, the photoelectrochemical biosensing of glucose in the FIA system was studied by monitoring of the changes in the electrocatalyzed reduction peak current of dissolved O2 at the proposed electrode dependent on glucose concentration. The proposed photoelectrochemical FIA method has a linear response to glucose ranging from of 0.01 to 1.0 mM with detection limit of 3.0 μM under optimized conditions. Photoelectrochemical biosensor was successfully fabricated in FIA system for selective, sensitive and repeatable detection of glucose and has been satisfactorily applied to determination of glucose in real sample.  相似文献   

12.
A novel disposable biamperometric capillary-fill device for glucose was fabricated using thick-film technology and incorporating a polymer mediator and glucose oxidase. A simple electrode system consisting of two identical carbon screen-printed electrodes was used as a transducer. The reagent ink of glucose oxidase and [Os(bpy)2(PVP)10Cl]Cl was drop-coated on the biosensor substrate between the strips of the electrode. A microliter biamperometric capillary-fill device was constructed by adhesion of a glass cover and the biosensor substrate. A drop of test solution was automatically introduced into the microchannel by capillary action, and then a water-soluble layer containing glucose oxidase was solubilized and quickly dispersed throughout the volume of the microchannel. With a voltage of +200mV applied, the current response was directly proportional to the concentration of glucose in the solution. The disposable device for the analysis of glucose shows a linear response range from 0 to 15mM and is virtually insusceptible to interfering species such as 1mM ascorbic acid. The device designed was successfully applied to the determination of glucose in human serum.  相似文献   

13.
This paper describes the use of scanning electrochemical microscopy (SECM) in the tip generation/substrate collection (TG/SC), or feedback, mode and substrate generation/tip collection (SG/TC) mode to measure homogeneous kinetics in the catalytic EC' process. Theoretical analyses of both configurations have been developed numerically to allow the optimal conditions for sensitive kinetic measurements to be determined. This is shown to involve collection efficiency measurements as a function of tip-substrate electrode distance in the case of TG/SC measurements and tip (collector current) images in a plane normal to the substrate electrode for the SG/TC mode. An important consideration for the SECM configuration (particularly for TG/SC and feedback measurements) is that the electroinactive co-reactant may be depleted more significantly than with other electrode geometries, because of cycling of the redox couple in the tip/substrate electrode gap, while the co-reactant can only enter this gap by hindered diffusion. The approaches described are examined through studies of the oxidation of amidopyrine by electrogenerated Fe(CN) in 0.5 mol dm(-3) aqueous KOH solution. A second-order rate constant of 390 ± 80 dm(3) mol(-1) s(-1) is obtained from TG/SC measurements, consistent with SG/TC quantitative imaging measurements. The consistency of the kinetic measurements confirms the validity of the approaches described. The kinetic constant is lower than expected based on previous ultramicroelectrode (UME) studies, and this is attributed to the fact that background currents for the direct heterogeneous oxidation of amidopyrine are more significant with conventional UME measurements, which will tend to enhance the current measured and may therefore lead to an overestimation of kinetic constants. The TG/SC approach, on the other hand, provides a means of making dual-electrode collection efficiency measurements with diffusional feedback of the redox couple, leading to superior voltammetric responses and enabling more accurate kinetic determination.  相似文献   

14.
The homogeneous reaction between glucose oxidase and osmium bipyridine-pyridine carboxylic acid in the presence of glucose has been studied in detail by cyclic voltammetry and digital simulation. Combination of the analytical equations that describe the dependence of the amperometric response on enzyme, substrate and co-substrate concentrations for the limiting cases with digital simulation of the coupled enzyme reaction diffusion problem allows us to extract kinetic parameters for the substrate-enzyme reaction: K(MS)=10.8 mM, k(cat)=254 s(-1) and for the redox mediator-enzyme reaction, k=2.2x10(5) M(-1) s(-1). The accurate determination of the kinetic parameters at low substrate concentrations (<7 mM) is limited by depletion of the substrate close to the electrode surface. At high substrate concentrations (>20 mM) inactivation of the reduced form of glucose oxidase in the bulk solution must be taken into account in the analysis of the results.  相似文献   

15.
The direct electrochemistry of glucose oxidase (GOx) immobilized on a composite matrix based on chitosan (CHIT) and NdPO(4) nanoparticles (NPs) underlying on glassy carbon electrode (GCE) was achieved. The cyclic voltammetry and electrochemical impedance spectroscopy were used to characterize the modified electrode. In deaerated buffer solutions, the cyclic voltammetry of the composite films of GOx/NdPO(4) NPs/CHIT showed a pair of well-behaved redox peaks that are assigned to the redox reaction of GOx, confirming the effective immobilization of GOx on the composite film. The electron transfer rate constant was estimated to be 5.0 s(-1). The linear dynamic range for the detection of glucose was 0.15-10 mM with a correlation coefficient of 0.999 and the detection limit was estimated at about 0.08 mM (S/N=3). The calculated apparent Michaelis-Menten constant was 2.5 mM, which suggested a high affinity of the enzyme-substrate. The immobilized GOx in the NdPO(4) NPs/CHIT composite film retained its bioactivity. Furthermore, the method presented here can be easily extended to immobilize and obtain the direct electrochemistry of other redox enzymes or proteins.  相似文献   

16.
《Electroanalysis》2017,29(7):1741-1748
The determination of lead ions by inhibition of choline oxidase enzyme has been evaluated for the first time using an amperometric choline biosensor. Choline oxidase (ChOx) was immobilized on a glassy carbon electrode (GCE) modified with multiwalled carbon nanotubes (MWCNT) through cross‐linking with glutaraldehyde. In the presence of ChOx, choline was enzymatically oxidized into betaine at –0.3 V versus Ag/AgCl reference electrode, lead ion inhibition of enzyme activity causing a decrease in the choline oxidation current. The experimental conditions were optimised regarding applied potential, buffer pH, enzyme and substrate concentration and incubation time. Under the best conditions for measurement of the lowest concentrations of lead ions, the ChOx/MWCNT/GCE gave a linear response from 0.1 to 1.0 nM Pb2+ and a detection limit of 0.04 nM. The inhibition of ChOx by lead ions was also studied by electrochemical impedance spectroscopy, but had a narrower linear response range and low sensitivity. The inhibition biosensor exhibited high selectivity towards lead ions and was successfully applied to their determination in tap water samples.  相似文献   

17.
Enzyme-functionalized gold nanowires for the fabrication of biosensors   总被引:3,自引:0,他引:3  
Gold nanowires were prepared by an electrodeposition strategy using nanopore polycarbonate (PC) membrane, with the average diameter of the nanowires about 250 nm and length about 10 microm. The nanowires prepared were dispersed into chitosan (CHIT) solution and stably immobilized onto glassy carbon electrode (GCE) surface. The electrochemical behavior of gold nanowire modified electrode and its application to the electrocatalytic reduction of hydrogen peroxide (H(2)O(2)) were investigated. The modified electrode allows low potential detection of hydrogen peroxide with high sensitivity and fast response time. Moreover, the good biocompatibility of nanometer-sized gold, the vast surface area of the nanowire-structure make it ideal for adsorption of enzymes for the fabrication of biosensors. Glucose oxidase was adsorbed onto the nanowire surface to fabricate glucose biosensor as an application example. The detection of glucose was performed in phosphate buffer (pH 6.98) at -0.2 V. The resulting glucose biosensor exhibited sensitive response, with a short response time (<8 s), a linear range of 10(-5)-2 x 10(-2) M and detection limit of 5 x 10(-6) M.  相似文献   

18.
One of the major problems in amperometric biosensors based on detection of H2O2 produced by enzymatic reaction between oxidase enzymes and substrate is the interference of redox active compounds such as ascorbic acid (AA), dopamine (DA) and uric acid (UA). To minimize these interferences, sodium bismuthate was used for the first time as an insoluble pre‐oxidant in the flow injection (FI) amperometric glucose biosensor at a Glucose oxidase (GOx) immobilized Pt/Pd bimetallic modified pre‐anodized pencil graphite electrode (p.PGE). In this context, these interfering compounds were injected into a flow injection analysis (FIA) system using an injector which was filled with NaBiO3. Thus, these interferents were converted into their redox inactive oxidized forms before reaching the electrode in the flow cell. While glucose was not influenced by the pre‐oxidant in the injector, the huge oxidation peak currents of the interferents decreased significantly in the biosensor. FI amperometric current time curves showed that the AA, DA and UA were minimized by 96 %, 86 %, and 98 % respectively, in the presence of an equivalent concentration of interferences in a 1.0 mM glucose solution. The proposed FI amperometric glucose biosensor exhibits a wide linear range (0.01–10 mM, R2=0.9994) with a detection limit of 2.4×10?3 mM. Glucose levels in the artificial serum and two real samples were successfully determined using the fabricated FI amperometric biosensor.  相似文献   

19.
A method is developed for quantitative determination of glucose using electrochemical impedance spectroscopy (EIS). The method is based on immobilized glucose oxidase (GOx) on the topside of gold mercaptopropionic acid self-assembled monolayers (Au-MPA-GOx SAMs) electrode and mediation of electron transfer by parabenzoquinone (PBQ). The PBQ is reduced to hydroquinone (H(2)Q), which in turn is oxidized at Au electrode in diffusion layer. An increase in the glucose concentration results in an increase in the diffusion current density of the H(2)Q oxidation, which corresponds to a decrease in the faradaic charge transfer resistance (R(ct)) obtained from the EIS measurements. Glucose is quantified from linear variation of the sensor response (1/R(ct)) as a function of glucose concentration in solution. The method is straightforward and nondestructive. The dynamic range for determination of glucose is extended to more than two orders of magnitude. A detection limit of 15.6 microM with a sensitivity of 9.66 x 10(-7) Omega(-1)mM(-1) is obtained.  相似文献   

20.
Based on hemin‐MWCNTs nanocomposite and hemin‐catalyzed luminol‐H2O2 reaction, a sensitive electrogenerated chemiluminescence (ECL) cholesterol biosensor was proposed in this paper. Firstly, hemin‐MWCNTs was prepared via π–π stacking and modified on the surface of GCE. Subsequently, cholesterol oxidase (ChOx) was adsorbed on the modified electrode to achieve a cholesterol biosensor. Hemin‐MWCNTs nanocomposite provided the electrode with a large surface area to load ChOx, and endowed the nanostructured interface on the electrode surface to enhance the performance of biosensor. The biosensor responded to cholesterol in the linear range from 0.3 µM to 1.2 mM with a detection limit of 0.1 µM (S/N=3).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号