首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
采用水热合成法制备了正八面体Cu2O/Cu修饰的多孔Ni(NF)自支撑电极(Cu2O/Cu-NF),并对其进行了形貌和结构表征。 在三电极体系下,在碱性介质中以循环伏安法和恒电位安培法测试其对葡萄糖催化氧化性能。 结果表明,150 ℃水热法制备的自支撑电极对葡萄糖的电催化氧化活性最强。 响应电流与葡萄糖浓度在3.7×10-3~1.1 mmol/L和1.4~5.0 mmol/L范围内呈线性相关,响应灵敏度分别是6929和706.1 μA/(mmol·L-1·cm2),且具有良好的选择性和稳定性,对无酶葡萄糖传感器的发展有重要意义。  相似文献   

2.
Cai CX  Xue KH 《Talanta》1998,47(5):4188-1119
A stable electroactive thin film of poly(toluidine blue o) (PTOB) has been deposited on the surface of a glassy carbon electrode by cyclic voltammetry from an aqueous solution containing toluidine blue o (TOB). Cyclic voltammograms of PTOB indicate the presence of two redox couples and the formal potential shifts linearly in the negative direction with increasing solution pH with a slope of 58 and 54 mV per pH unit for couple I and couple II, respectively. The PTOB modified glassy carbon electrode shows electrocatalytic activity toward NADH oxidation in phosphate buffer solution (pH 7.0), with an overpotential ca. 470 mV lower than that of the bare electrode. The catalytic rate constant of the modified glassy carbon electrode for the oxidation of NADH is determined by cyclic voltammetry and rotating disk electrode measurements. The experimental results indicate that the electrode can be used as a detector for NADH determination with a linear range of 5.0×10−6 to 2.0×10−3 mol l−1 and the detection limits of (5.0±0.3)×10−7 mol l−1 at optimal conditions.  相似文献   

3.
《Electroanalysis》2004,16(11):904-909
A phthalocyanine based sensor, for anodic detection of sodium ethylene bisdithiocarbamate (Nabam) by coating a mixture of cobalt phthalocyanine (CoPC) modified carbon ink on the surface of a glassy carbon electrode, has been described. The modified ink was prepared by mixing three percent of cobalt phthalocyanine into carbon ink and then diluting the mixture with cyclohexanone in w/w ratio of 1/9. A suitable portion (or 1 μL) of ink mixture was then dip‐coated on a rotating disk glassy carbon electrode. The modified ink electrode was air‐dried for 15 mins before use. In comparison to the bare ink electrode on which the oxidation of Nabam takes place at 300 mV (vs. 3 M Ag/AgCl), the oxidation potential (?125 mV) of Nabam at the CoPC modified ink decreases significantly. A typical calibration plot of Nabam proportionally increases over the concentration range of 2.5 to 36 μM (R=0.9990). The detection limit is estimated about 28.8 nM (S/N=3) and its response time (between 10% to 90% of steady‐state response) is about 5.3 s at the injection of 5 μM Nabam. The sensitivity requirement of JMPR meeting (Joint FAO/WHO Meeting on Pesticide Residues) for ethylene bisdithiocarbamates (EBDCs) is achieved by this proposed scheme.  相似文献   

4.
The oxidation of electrodeposited Co electrodes has been studied in 0.1 M KOHaq at potentials more negative than ?880 mV vs. Hg|HgO by means of electrochemical quartz crystal microbalance (EQCM) and rotating ring disk electrode coupled with cyclic voltammetry (CV) and chronoamperometry (CA). Dissolution of cobalt was found to be insignificant and does not constitute a step in the overall process of formation of the oxidised layer. The irreversibility of the oxidation process depends on the electrode potential and oxidation time. The composition of the oxidised layer depends on the oxidation potential: Co(OH)2 is formed at more negative potentials, while at more positive potentials CoO is the prevailing product. The results obtained by means of three techniques (CV, CA and EQCM) reveal that at potentials not higher than ?880 mV, the oxidation of Co follows a direct logarithmic law. The mechanism of the process is discussed.  相似文献   

5.
Several types of amperometric biosensors comprised of immobilized glucose oxidase in chemically-modified ceramic-carbon matrices are compared. The electrodes are comprised of several building blocks each performing a specific function. Glucose oxidase is used to catalyze the bio-oxidation of glucose; carbon powder imparts conductivity and favorable electrochemical characteristics; the Ormosil network provides rigidity and porosity; and the organic modification of the Ormosil imparts controlled surface polarity. Additionally, hydrophilic chemical modifiers are incorporated in order to control the size of the wetted, electroactive layer; high dispersion of inert metal catalysts is used to enhance hydrogen peroxide oxidation and redox mediators may be co-immobilized when oxygen independent response is desirable. The electrodes can be prepared either in the form of thick supported film, useful for disposable electrodes or as bulk-modified, disk shape electrodes, which can be used as renewable surface electrodes.  相似文献   

6.
The electrochemical determination of iodide was studied at boron-doped diamond thin film electrodes (BDD) using cyclic voltammetry (CV) and flow-injection (FI) analysis, with amperometric detection. Cyclic voltammetry of iodide was conducted in a phosphate buffer pH 5. Experiments were performed using glassy carbon (GC) electrode as a comparison. Well-defined oxidation waves of the quasi-reversible cyclic voltammograms were observed at both electrodes. Voltammetric signal-to-background ratios (S/B) were comparable. However, the GC electrode gives much greater in the background current as usual. The potential sweep rate dependence exhibited that the peak current of iodide oxidation at 1 mM varied linearly (r2 = 0.998) with the square root of the scan rate, from 0.01 to 0.30 V s−1. This result indicates that the reaction is a diffusion-controlled process with negligible adsorption on BDD surface, at this iodide concentration. Results of the flow-injection analysis show a highly reproducible amperometric response. The linear working range was observed up to 200 μM (r2 = 0.999). The detection limit, as low as 0.01 μM (3σ of blank), was obtained. This method was successfully applied for quantification of iodide contents in nuclear emergency tablets.  相似文献   

7.
Application of parallel and serial dual electrode detectors for capillary electrophoresis was first described. In parallel dual electrode approach, two 100 μm-diameter Cu disks arranged side by side were used as the dual working electrode for the simultaneous determination of a mixture of carbohydrates and amino acids. In serial dual electrode approach, two working electrodes were arranged in a disk-ring manner for the simultaneous determination of both cysteine and cystine; the disk electrode was Hg/Au serving as the upstream electrode, the ring electrode was 5% CoPC carbon paste serving as the downstream electrode.  相似文献   

8.
Gold nanoparticles were self-assembled to the modified glassy carbon electrode (GC) with cysteamine (CA) to prepare the nano-Au/CA/GC modified electrode. The electrochemical behavior of epinephrine (EP) on the modified electrode was explored with cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Epinephrine gave a pair of redox peaks at Epa = 0.190 mV and Epc = −0.224 mV (versus SCE), respectively. The nano-Au/CA/GC modified electrode shows an excellent electrocatalytic activity for the oxidation of EP. The modified electrode could be used to determine EP in the presence of ascorbic acid (AA). The response of catalytic current with EP concentration shows a linear relation in the range of 1.0 × 10−7 to 5.0 × 10−4 mol L−1 with the correlation coefficient of 0.998. The detection limit is 4.0 × 10−8 mol L−1. The modified electrode exhibited a good reproducibility, sensitivity and stability for the determination of EP injection.  相似文献   

9.
本文利用旋转圆盘电极系统研究了酸性介质中H2O2在Au(100)和Au(111)电极表面的电化学行为. 实验发现在Au电极上H2O2难以发生还原,但是当电位稍微正于H2O2氧化为O2的平衡电势时即可发生氧化. 在Au(111)上H2O2氧化的起始电位比在Au(100)正0.1 V左右. Au(100)上的双桥位位点能增强反应中间体*OOH的吸附,可能是导致Au(100)上H2O2氧化反应超电势比Au(111)低的主要原因. 在较正电位区(E>1.2 V), 当电极表面被氧物种覆盖时,H2O2在两个电极上的氧化都会受到一定程度的抑制,这种影响在Au(111)上比Au(100)上更加明显,这与Au(111)上氧物种的生成与逆向还原可逆性差的趋势一致. 最后还将Au与Pt单晶电极上H2O2氧化的行为进行了对比分析.  相似文献   

10.
Yamamoto K  Zeng H  Shen Y  Ahmed MM  Kato T 《Talanta》2005,66(5):1175-1180
An amperometric glucose ring-disk biosensor based on a ruthenium complex mediator of low redox potential was fabricated and evaluated. This thin-layer radial flow microsensor (10 μl) with ring-disk working electrode displayed remarkable amperometric sensitivity. For Ru33-O)(AcO)6(Py)3(ClO4) (Ru-Py), a trinuclear oxo-acetate bridged cluster, a reversible redox curve of low redox potential and narrow potential window (redox potentials were −0.190 and −0.106 V versus Ag/AgCl wire, respectively) was observed, which is comparable to many reported mediators such as ferrocene derivatives and other ruthenium complexes. The glucose and hydrogen peroxide assays were carried out with this complex-modified electrode Ru-Py-HRP-GOx/Nafion. The sensitivity was obtained 24 nA (15.4 mA M−1 cm−2) for 10 μM glucose and 126 nA (160 mA M−1 cm−2) for 5 μM H2O2, respectively with a working potential at 0 V versus Ag/AgCl. Ascorbic acid was studied as interference to the glucose assay. The application of 0 V potential versus Ag/AgCl did not avoid the occurrence of the oxidation of ascorbic acid, however, the pre-coating of ascorbate oxidase on the disk part of the ring-disk working electrode efficiently pre-oxidized the ascorbic acid and hence eliminated its interference on the glucose response. The practical reliability was also evaluated by assaying the dialysate from the prefrontal cortex of Wistar rats.  相似文献   

11.
对铜-聚四氟乙烯复合电极的制作方法进行了研究,对其电分析性能做了考察,用XPS及SEM对电极表面形态进行了表征。实验证明,以5mA/cm2的电流密度镀0.5C所得的复合电极有优良的机械性能和分析性能,将其与裸铜电极相比,前者不仅加宽了电位窗,而且增大了对醇醛糖的恒电位安培法响应。将它做成流动注射分析检测池的柱状工作电极,则背景信号降低,使检出限进一步降低。可检出3×10-6mol/L葡萄糖。本文还对它们的电氧化过程作了探讨。  相似文献   

12.
Graphene modified electrodes have been fabricated by electrodeposition from an aqueous graphene oxide solution onto conducting Pt, Au, glassy carbon, and indium tin dioxide substrates. Detailed investigations of the electrochemistry of the [Ru(NH(3))(6)](3+/2+) and [Fe(CN)(6)](3-/4-) and hydroquinone and uric acid oxidation processes have been undertaken at glassy carbon and graphene modified glassy carbon electrodes using transient cyclic voltammetry at a stationary electrode and near steady-state voltammetry at a rotating disk electrode. Comparisons of the data with simulation suggest that the transient voltammetric characteristics at graphene modified electrodes contain a significant contribution from thin layer and surface confined processes. Consequently, interpretations based solely on mass transport by semi-infinite linear diffusion may result in incorrect conclusions on the activity of the graphene modified electrode. In contrast, steady-state voltammetry at a rotating disk electrode affords a much simpler method for the evaluation of the performance of graphene modified electrode since the relative importance of the thin layer and surface confined processes are substantially diminished and mass transport is dominated by convection. Application of the rotated electrode approach with carbon nanotube modified electrodes also should lead to simplification of data analysis in this environment.  相似文献   

13.
Carbon paste electrodes were modified with a nitrofluorenone derivative, 2,4,7-trinitro-9-fluorenone, adsorbed on zirconium phosphate (ZP). After electrochemical reduction of the fluorenone derivative, it turns into a very efficient mediator for electrocatalytic NADH oxidation, with a formal potential of about +250 mV vs. Ag/AgCl. The electrochemistry and the electrocatalytic properties of the mediator were investigated with cyclic voltammetry and rotating disk electrode methodology. The second order rate constant with NADH was evaluated and found to be higher than 10(6) M(-1) s(-1), thus approaching true diffusion controlled currents for NADH oxidation.  相似文献   

14.
The electrochemical behavior of L-tyrosine was investigated at a multi-wall carbon nanotubes modified glassy carbon electrode. L-tyrosine itself showed a poor electrochemical response at the bare glassy carbon electrode; however, a multi-wall carbon nanotubes film fabricated on the glassy carbon electrode can directly enhance the electrochemical signal of L-tyrosine when applying cyclic voltammetry and square wave stripping voltammetry without any mediator. Cyclic voltammetry was carried out to study the electrochemical oxidation mechanism of L-tyrosine, which shows a totally irreversible process and an oxidation potential of 671 mV at the modified electrode and 728 mV at the bare electrode, ΔEp = 57 mV. The anodic peak current linearly increases with the square root of scan rate in the low range, suggesting that the oxidation of L-tyrosine on the multi-wall carbon nanotubes modified electrode is a diffusion-controlled process. The square wave stripping voltammetry currents of L-tyrosine at the multi-wall carbon nanotubes modified electrodes increased linearly with the concentration in the range of 2.0 × 10−6–5.0 × 10−4 mol L−1. The detection limit was 4.0 × 10−7 mol L−1. The method is simple, quick, sensitive and accurate.  相似文献   

15.
Cox JA  Lewinski K 《Talanta》1993,40(12):1911-1915
Either an iridium electrode that was anodically pretreated or a glassy carbon electrode that was coated with a film that contained iridium oxide promoted the oxidation of hydrogen peroxide. With flow injection methodology, linear calibration curves were obtained over the 2 × 10−5 −3.6 × 10−8M range with 0.1M KOH as the carrier. With solutions of pH 11, oxidation occurred at applied potentials of near 0.0 V vs. SCE, which is much lower than potentials needed at bare Pt or glassy carbon. The low overpotential suggests applications to systems where oxidation of other species limits the use of bare electrodes. Cyclic voltammetric studies show that HO2 is the electroactive species and that catalysis rather than mediation promotes the charge transfer. Dissolved oxygen does not interfere with the measurement.  相似文献   

16.
Cu2O/nitrogen-doped grapheme(NG) nanocomposite material was prepared via a facile one step chemical reduction and characterized by means of X-ray diffraction(XRD) and scanning electron microscopy(SEM). A new electrochemical sensor was then fabricated by coating Cu2O/nitrogen-doped graphene nanocomposite with Nafion on glassy carbon electrode(Cu2O/NG/Nafion/GCE). The electrochemical response of this modified electrode toward ofloxacin was examined by cyclic voltammetry. The results indicate that Cu2O/NG/Nafion composite-modified electrode exhibits higher catalytic activity in the electrochemical oxidation of ofloxacin compared with glassy carbon electrode(GCE), Cu2O/Nafion modified electrode(Cu2O/Nafion/GCE), and N-doped graphene/Nafion modified electrode(NG/Nafion/GCE). Under optimal conditions, the peak current was found to be linearly proportional to the concentration of ofloxacin in the 0.5-27.5 μmol/L and 27.5-280 μmol/L ranges with a lower detection limit of 0.34 μmol/L, higher sensitivity of 39.32 μA·L·mmol-1 and a shorter reaction time of less than 2 s. In addition, Nafion can enhance the stability of the modified electrode and prevent some negative species. Thus the modified electrode exhibits good selectivity and a long working life. The Cu2O/NG/Nafion composite modified electrode shows promising application in electrochemical sensors, biosensors, and other related fields because of its excellent properties.  相似文献   

17.
We have successfully developed a highly sensitive electrochemical sensor strip for a home blood-sugar monitoring device by a single-step straightforward procedure. The strip consists of a pair of screen-printed carbon electrodes, which work as counter and working electrodes in the chronoamperometric mode. To remedy the poor electrochemical activity of the printed carbon electrode, a small amount of gold nanoparticles was immobilized on the electrode. In the presence of glucose oxidase, the electrode modified with 2-nm particles showed about a five times higher sensitivity for glucose oxidation than the bare printed carbon electrode, and there was a significant dependence of the current on the particle diameter. Based on these observations, we have elucidated the glucose oxidation mechanism, which is comprised of two key factors, i.e. (1) electron transfer between the gold particles, and (2) electronic coupling between the gold particles and glucose oxidase.  相似文献   

18.
基于TiO2/Ti电极在含Cu2+溶液中的循环伏安图,调节电沉积的沉积电压,我们在TiO2平整表面制备出Cu2O和/或Cu颗粒.通过扫描电镜(SEM)、X射线衍射(XRD)和X射线光电子能谱(XPS)表征,发现Cu2O和Cu有不同的生长机制:Cu2O颗粒在TiO2表面分散结晶,而Cu颗粒是在已生长的颗粒上成核,从而形成堆积颗粒结构.这是由于在Cu2O/TiO2界面和Cu/TiO2界面形成不同的能带结构,使得电子的转移方式不同.与纯TiO2光阳极比较,可以观察到Cu2O/TiO2和Cu/TiO2异质结构的光电流均有显著增强.特别地,存在一个电压区间使得Cu2O和Cu同时生长在TiO2表面,此时对应的光电流比较稳定并且能达到最大.紫外-可见(UV-Vis)漫反射光谱、电化学阻抗谱(EIS)和光电流-电压特性曲线均显示,Cu2O和Cu明显有助于光的可见光吸收,同时Cu/TiO2在光电转换过程中显示更宽波段的可见光利用率.此外,开路电压的增加、有效的电荷分离和电极/电解质界面上载流子的快速迁移也增强了材料的光电化学性质.  相似文献   

19.
Hu SQ  Xie JW  Xu QH  Rong KT  Shen GL  Yu RQ 《Talanta》2003,61(6):769-777
An electrochemical immunosensor for the direct determination of paraoxon has been developed based on the biocomposites of gold nanoparticles loaded with paraoxon antibodies. The biocomposites are immobilized on the glassy carbon electrode (GCE) using Nafion membrane. On the immunosensor prepared paraoxon shows well-shaped CV with reduction and oxidation peaks located −0.08 and −0.03 mV versus SCE, respectively. The detection of paraoxon performed at −0.03 mV is beneficial for guaranteeing sufficient selectivity. The amount of the biocomposite consisting gold nanoparticles loaded with antibodies and the volume of Nafion solution used for fabricating the immunosensor have been studied to ensure sensitivity and conductivity of the immunosensor. The immunosensor has been employed for monitoring the concentrations of paraoxon in aqueous samples up to 1920 μg l−1 with a detection limit of 12 μg l−1.  相似文献   

20.
An ionic liquid-type carbon paste electrode (IL-CPE) had been fabricated by replacing non-conductive organic binders with a conductive room temperature ionic liquid, 1-pentyl-3-methylimidazolium hexafluorophosphate (PMIMPF6). The electrochemical responses of calcium dobesilate were investigated at the IL-CPE and the traditional carbon paste electrode (T-CPE) in 0.05 mol L−1 H2SO4, respectively. The results showed the superiority of IL-CPE to T-CPE in terms of provision of higher sensitivity, faster electron transfer and better reversibility. A novel method for determination of calcium dobesilate was proposed. The oxidation peak current was rectilinear with calcium dobesilate concentration in the range of 8.0 × 10−7 to 1.0 × 10−4 mol L−1, with a detection limit of 4.0 × 10−7 mol L−1(S/N = 3) by differential pulse voltammetry. The proposed method was applied to directly determine calcium dobesilate in capsule and urine samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号