首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel high-performance liquid chromatographic method for the determination of codeine, norcodeine and morphine in plasma and urine has been developed. The compounds were separated on a cyano column (15 cm x 4.6 mm, 5 microns particle size) using a mobile phase of acetonitrile-triethylamine-distilled water (4:0.1:95.9, v/v) pH 3.1 and then determined by fluorescence detection. Calibration curves in the range 5-200 ng/ml for plasma and 0.1-10 micrograms/ml for urine were linear and passed through the origin. The imprecision and inaccuracy of the assay were less than 10% and the limits of detection were 2 ng/ml for all three compounds in human plasma.  相似文献   

2.
A high-performance liquid chromatographic method for the measurement of bumetanide in plasma and urine is described. Following precipitation of proteins with acetonitrile, bumetanide was extracted from plasma or urine on a 1-ml bonded-phase C18 column and eluted with acetonitrile. Piretanide dissolved in methanol was used as the internal standard. A C18 Radial Pak column and fluorescence detection (excitation wavelength 228 nm; emission wavelength 418 nm) were used. The mobile phase consisted of methanol-water-glacial acetic acid (66:34:1, v/v) delivered isocratically at a flow-rate of 1.2 ml/min. The lower limit of detection for this method was 5 ng/ml using 0.2 ml of plasma or urine. Nafcillin, but not other semi-synthetic penicillins, was the only commonly used drug that interfered with this assay. No interference from endogenous compounds was detected. For plasma, the inter-assay coefficients of variation of the method were 7.6 and 4.4% for samples containing 10 and 250 ng/ml bumetanide, respectively. The inter-assay coefficients of variation for urine samples containing 10 and 2000 ng/ml were 8.1 and 5.7%, respectively. The calibration curve was linear over the range 5-2000 ng/ml.  相似文献   

3.
An improved method for the simultaneous determination of cocaine, norcocaine, benzoylecgonine and benzoylnorecgonine using reversed-phase high-performance liquid chromatography with ultraviolet detection is described. Following solid-phase extraction, chromatography was performed using a column containing an octadecylsilica-coated packing, eluted with 6% acetonitrile in phosphate buffer, pH 2.1, and detected at 233 nm. Using 80-microliters samples, the detection limit is 18 ng/ml for benzoylecgonine and benzoylenorecgonine and 35 ng/ml for cocaine and norcocaine. The coefficients of variation range from 3.5% (benzoylecgonine) to 7.0% (norcocaine). The procedure has been applied to samples of guinea pig plasma, urine and amniotic fluid and human urine.  相似文献   

4.
A liquid chromatographic method using a solid-phase extraction procedure for the quantification of sotalol in plasma and urine is described. Sotalol is eluted from an extraction column with ethyl acetate-acetonitrile (1:2) and, after separation by reversed-phase high-performance liquid chromatography on a mu Bondapak C18 column, is quantified by fluorescence detection at excitation and emission wavelengths of 240 and 310 nm, respectively. The method has been demonstrated to be linear over the concentration ranges 10-6000 ng/ml in plasma and 0.5-100 micrograms/ml in urine. Mean inter-assay accuracy of the method for plasma ranged from 93 to 100% and for urine from 102 to 114%; precision ranged from 0.5 to 1.6% for plasma over a concentration range of 200-4000 ng/ml and for urine from 0.7 to 2.0% at concentrations of 2-50 micrograms/ml. Mass spectrometry confirmed the presence of sotalol in isolated chromatographic fractions of plasma and urine extracts from subjects given sotalol orally.  相似文献   

5.
The simultaneous isolation and determination of mitoxantrone (Novantrone) and its two known metabolites (the mono- and dicarboxylic metabolites) were carried out using a high-performance liquid chromatographic (HPLC) system equipped with an automatic pre-column-switching system that permits drug analysis by direct injection of biological samples. Plasma or urine samples were injected directly on to an enrichment pre-column flushed with methanol-water (5:95, v/v) as the mobile phase. The maximum amount of endogenous water-soluble components was removed from biological samples within 9 min. Drugs specifically adsorbed on the pre-column were back-flushed on to an analytical column (Nucleosil C18, 250 X 4.6 mm I.D.) with 1.6 M ammonium formate buffer (pH 4.0) (2.5% formic acid) containing 20% acetonitrile. Detection was effected at 655 nm. Chromatographic analysis was performed within 12 min. The detection limit of the method was about 4 ng/ml for urine and 10 ng/ml for plasma samples. The precision ranged from 3 to 11% depending on the amount of compound studied. This technique was applied to the monitoring of mitoxantrone in plasma and to the quantification of the unchanged compound and its two metabolites in urine from patients receiving 14 mg/m2 of mitoxantrone by intravenous infusion for 10 min.  相似文献   

6.
Two different reversed-phase high-performance liquid chromatographic methods for the determination of aniracetam (I) and its metabolite N-anisoyl-GABA (II) in human plasma are described. The procedure for I involves direct injection of plasma samples spiked with the internal standard on a clean-up column followed by reversed-phase chromatography on a C18 column. The limit of quantification was 5 ng/ml, using a 200-microliters specimen of plasma. The mean inter-assay precision of the method up to 800 ng/ml was 3%. The procedure for II involved liquid-liquid extraction of II and the internal standard from plasma with ethyl acetate, and reversed-phase chromatography on a C18 column. The limit of quantification was 50 ng/ml using a 0.5-ml plasma specimen. The mean inter-assay precision up to 50 micrograms/ml was 6%. The applicability and accuracy of the methods were demonstrated by the analysis of over 1000 plasma samples from two bioavailability studies in healthy volunteers.  相似文献   

7.
The quantitative determination of the quaternary spasmolytic compound ciclotropium and its metabolite N-isopropyltropinium is described for human plasma and urine. The analytical procedure consists of ion-pair extraction from biological material, alkaline hydrolysis, subsequent derivatization with the fluorophor flunoxaprofen chloride and separation by high-performance liquid chromatography on a reversed-phase column with fluorimetric monitoring. The detection limits of 0.5 ng/ml in plasma and 10 ng/ml in urine at signal-to-noise ratios higher than 3 permit the determination of pharmacokinetic parameters after therapeutic doses.  相似文献   

8.
A sensitive and selective high-performance liquid chromatographic method for determination of intact glipizide in human plasma or urine has been developed. The plasma and urine samples were acid-buffered, before tolbutamide was added as internal standard. The samples were extracted with benzene, and the organic layer was evaporated to dryness. The residue was dissolved in equilibrated mobile phase (acetonitrile-0.01 M phosphate buffer pH 3.5, 35:65), and an aliquot of 20 microliters was chromatographed on a Spherisorb ODS reversed-phase column. Quantitation was achieved by monitoring the ultraviolet absorbance at 275 nm. The response was linear (0-1000 ng/ml) and the detection limit was 5-10 ng/ml in plasma or urine. The within-assay variation was less than or equal to 10%. No interferences from metabolites or endogenous constituents were observed. The utility of the assay was demonstrated by determining glipizide in samples from a diabetic subject receiving a therapeutic dose of 5 mg of the drug.  相似文献   

9.
A sensitive and reproducible high-performance liquid chromatographic method was developed to assay ampherotericin B in plasma, blood, urine and various tissue samples. Amphotericin B was isolated from each sample matrix by solid-phase extraction (Bond-Elut). The eluate from Bond-Elut containing amphotericin B was injected onto a reversed-phase C18 column (Waters, mu Bondpak, 10 microns, 300 mm x 3.9 mm I.D.) with a mobile phase of 45% acetonitrile in 2.5 mM Na2EDTA at 1 ml/min. Detection of amphotericin B was by ultraviolet absorption at 382 nm. Blood and tissues were homogenized and extracted with methanol prior to Bond-Elut extraction. The extraction efficiencies of amphotericin B from plasma, blood and tissues were approximately 90, 70 and 75%, respectively. The sensitivity of the assay was less than or equal to 5 ng/ml for plasma, less than or equal to 25 ng/ml for blood, 2.5 ng/ml for urine and 50 ng/g for tissues. The linearity of the assay method was up to 2.5 micrograms/ml for plasma, 5 micrograms/ml for blood, 500 ng/ml for urine and 500 micrograms/g for tissues. The assay was reproducible with an intra-day coefficient of variation (C.V., n = 3) of less than 5% in general for plasma, blood and tissues. The inter-day C.V. of the assay was less than 5% for plasma (n = 5), less than 10% for blood (n = 4) and less than 5% for tissues (n = 3). The overall variability in the urine assay was generally less than 10%. This method has demonstrated significant improvement in the sensitivity and reproducibility in assaying amphotericin B in plasma and especially in blood, urine and tissues. We have employed this assay to compare the pharmacokinetic and tissue distribution profiles of amphotericin B in rats and dogs following administration of Fungizone and ABCD (amphotericin B-cholesteryl sulfate colloidal dispersion), a lipid-based dosage form. In addition, the assay method for plasma and urine samples can also be applied to pharmacokinetics studies of amphotericin B in man.  相似文献   

10.
A high-performance liquid chromatographic (HPLC) method for the determination of a new H2 receptor antagonist, 3-amino-5-[3-[4-(piperidinoindanyloxy)]propylamino] -1-methyl-1H-1,2,4-triazole (I), in human plasma and urine was developed. The method employs liquid-liquid extraction of the analyte and an internal standard and chromatographic separation using an alkylphenyl-bonded HPLC column. The total time of chromatography was less than 10 min. Sensitivity was 10 ng/ml for the plasma analysis and 1 microgram/ml for the analysis of I from urine. The coefficients of variation, based on interpolated concentrations, were less than 10%. The method was used for more than 5000 samples during clinical pharmacokinetic studies.  相似文献   

11.
A highly sensitive and selective high-performance liquid chromatographic method, involving sample pre-treatment, column switching and fluorimetric detection, is described for the determination of dihydroergotamine in plasma and urine samples. The pre-chromatographic sample treatment consists of extraction by means of an Extrelut column for plasma samples, and pre-separation with enrichment steps on a Sep-Pak column for urine samples. The samples are then injected onto a pre-separation column (Aquapore), and the fraction containing dihydroergotamine are automatically diverted onto an analytical column (ODS reversed phase). An acetonitrile-ammonium carbamate gradient is used as the mobile phase. High recovery of dihydroergotamine from both plasma (87%) and urine (100%) and a detection limit as low as 100 pg/ml were achieved, with a linear response up to 5 ng/ml. The assay demonstrated a high degree of selectivity with regard to the extensive metabolism of dihydroergotamine especially to the main metabolite 8'-hydroxydihydroergotamine. The assay was successfully applied for more than one year to the determination of plasma and urine concentrations of dihydroergotamine after parenteral administration.  相似文献   

12.
A high-performance liquid chromatographic method for the measurement of isepamicin, a new aminoglycoside, in plasma, urine and dialysate is reported. The assay utilizes a simple extraction of isepamicin in plasma using commercially available Cyano solid-phase cartridges and dilution of urine and dialysate samples. The separation is performed on a Hypersil C18 column (15 cm X 4.6 mm I.D., 5 microns particle size) and utilizes a mobile phase consisting of 10% methanol and 90% buffer solution containing 0.01 M sodium hexanesulfonate, 0.1 M sodium sulfate and 17 mM acetic acid. The flow-rate is 1.1 ml/min. Dibekacin is used as the internal standard. Isepamicin is derivatized post-column with o-phthalaldehyde for spectrofluorometric detection. The method can also be used for the measurement of other aminoglycosides, i.e. tobramycin, kanamycin, netilmicin and gentamicin. The assay is fast, accurate and has a quantitation limit of 100 ng/ml isepamicin in plasma and 50 ng/ml in urine and dialysate.  相似文献   

13.
A selective and sensitive high-performance liquid chromatographic method for determination of intact glibenclamide in human plasma or urine has been developed. With glibornuride as internal standard, acid-buffered plasma or urine was extracted with benzene. The organic layer was evaporated and the residue was dissolved in equilibrated mobile phase (acetonitrile-phosphate buffer 0.01 M pH 3.5, 50:50). An aliquot of 20 microliters was chromatographed on a Spherisorb ODS reversed-phase column, and quantitation was achieved by monitoring the ultraviolet absorbance at 225 nm. The response was linear (0-1000 ng/ml) and the detection limit was 5-10 ng/ml in plasma or urine. The within-assay variation was less than or equal to 10%. No interferences from metabolites or endogenous constituents could be noted. The utility of the method was demonstrated by analysing glibenclamide in samples from diabetic subjects on therapeutic doses of the drug.  相似文献   

14.
A sensitive, selective, and rapid high-performance liquid chromatographic procedure was developed for the determination of isoxicam in human plasma and urine. Acidified plasma or urine were extracted with toluene. Portions of the organic extract were evaporated to dryness, the residue dissolved in tetrahydrofuran (plasma) or acetonitrile (urine) and chromatographed on a mu Bondapak C18 column preceded by a 4-5 cm X 2 mm I.D. column packed with Corasil C18. Quantitation was obtained by UV spectrometry at 320 nm. Linearity in plasma ranged from 0.2 to 10 micrograms/ml. Recoveries from plasma samples seeded with 1.8, 4 and 8 micrograms/ml isoxicam were 1.86 +/- 0.077, 4.10 +/- 0.107 and 8.43 +/- 0.154 micrograms/ml with relative standard deviations of 3.3%, 2.5% and 5.4%, respectively. The linearity in urine ranged from 0.125 to 2 micrograms/ml. The precision of the method was 3.3-9.0% relative standard deviation over the linear range.  相似文献   

15.
A sensitive and selective method for the determination of the pyridinium metabolite (HPP+) derived from the antipsychotic drug haloperidol (HP) in brain tissue, plasma and urine using high-performance liquid chromatography with fluorescence detection is described. The HPP+ present in biological samples was extracted using a Sep-Pak C18 cartridge. Recoveries of HPP+ ranged from 78 to 90%. Final separation and quantitative estimations of HPP+ were achieved on a C18 reversed-phase column employing a mobile phase of acetonitrile-30 mM ammonium acetate (40:60, v/v) containing 10 mM triethylamine and adjusted to pH 3 with trifluoroacetic acid. The fluorescence detection utilized an excitation wavelength of 304 nm and an emission wavelength of 374 nm. Standard curves were linear in the range of 2.5-100 ng/ml for brain tissue homogenate and plasma samples and 10-500 ng/ml for urine samples. The detection limit of HPP+ was about 1 ng/ml in all biological samples. The concentrations of HPP+ in brain tissue, plasma and urine from HP-treated rats were determined using this method.  相似文献   

16.
A sensitive high-performance liquid chromatographic technique is described for the separation of R- and S-acebutolol in human plasma and urine. The procedure involves derivatization with the chiral reagent S-(+)-1-(1-naphthyl)ethyl isocyanate. The resulting diastereoisomers are quantified using normal-phase high-performance liquid chromatography with fluorescence detection (220/389 nm). Virtual baseline separation, free from interference, with achieved (resolution factor = 1.45). Excellent linearity (r greater than 0.998) was observed throughout the range 10-500 ng/l and 2-100 mg/l in plasma and urine, respectively. Inter-assay variability was less than 5% for each enantiomer at concentrations of 10 ng/ml. This method is applicable for the determination of the pharmacokinetics, in man, of acebutolol enantiomers in plasma and urine.  相似文献   

17.
An assay for 5-fluorouracil (5-FU) has been developed that utilizes a double extraction with ethyl acetate, followed by precolumn derivatization with 4-bromo-methyl-7-methoxycoumarin. The reaction mixture was quenched with 5% acetic acid, extracted with hexane, and analyzed by multi-dimensional high-performance liquid chromatography. Derivatized 5-FU was injected into a cyanopropyl column and a heart cut containing the analyte was then switched to an octadecyl column and quantitated by fluorescence detection. The assay had a limit of detection of 0.5 ng 5-FU/ml plasma and was linear to 20 micrograms/ml. It was shown to be free of interferences from the other anticancer agents commonly used in combination with 5-FU. This assay should have the sensitivity needed to measure the low levels that occur after low-dose, continuous infusion of 5-FU.  相似文献   

18.
A simple and sensitive high-performance liquid chromatographic assay was developed for the quantitative determination of major erythromycin components and their potential metabolites or degradation products in plasma and urine. An ether extract of alkalized plasma sample was chromatographed on a reversed-phase column and the components in the column effluent were monitored by an electrochemical detector. The recovery of the drug from extraction was virtually 100%. The detection limits for erythromycin A in plasma were 5-10 ng/ml and 30 ng/ml using 1 and 0.2 ml of sample, respectively. For urine samples, a simple one-step deproteinization with two volumes of acetonitrile was satisfactory for analysis. The method has been evaluated in plasma and urine from dogs receiving oral or intravenous erythromycin A. The standard curves for potential metabolites or degradation products were not constructed due to the lack of sufficient samples.  相似文献   

19.
A simple and sensitive high-performance liquid chromatographic procedure to determine spironolactone and its three major metabolites in biological specimens is described. The assay involves sequential extraction on C18 and CN solid phases, and subsequent separation on a reversed-phase column. In plasma samples, spironolactone and its metabolites were completely separated within 8 min using an isocratic mobile phase, while in urine samples a methanol gradient was necessary to achieve a good separation within 14 min. Recoveries for all analytes were greater than 80% in plasma and 72% in urine. Linear responses were observed for all compounds in the range 6.25-400 ng/ml for plasma and 31.25-2000 ng/ml for urine. The plasma and urine methods were precise (coefficient of variation from 0.8 to 12.5%) and accurate (-12.1% to 7.4% of the nominal values) for all compounds. The assay proved to be suitable for the pharmacokinetic study of spironolactone in healthy human subjects.  相似文献   

20.
Abstract

A high-performance liquid chromatography was developed for simultaneous determinations of Cinobufagin (CB) and its metabolites deacetylcinobufagin, 3-epideacetyl-cinobufagin, 3-ketodeacetylcinobufagin, 3-epicinobufagin and 3-ketodeacetylcinobufagin in serum and urine of rat. The biological samples were extracted with diethylether-ethylacetate (4:1v/v) in the presence of bufalin as the internal standard. Recoveries for CB and all other compounds were in the range of 80.8%–100.2%. Excellent resolution was obtained by reversed-phase chromatography on a 4.6 mm I.D.×150 mm ODS column using acetonitrile:water (50:50 v/v) as the mobile phase at a flow-rate of 0.7 ml/min with UV detector at 300 nm. Standard curve data revealed linearity over a range of 10–500 ng per ml serum and urine. The detection limits of CB and its metabolites were less than 10 ng/ml. Coefficients of variation for the analysis were less than 10. CB and its some metabolites were observed in  相似文献   