首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The high-performance liquid chromatographic behavior of some basic drugs was studied on a n-octadecylphosphonic acid modified magnesia-zirconia (C18PZM) stationary phase. The effect of mobile phase variables such as methanol content, ionic strength, and pH on their chromatographic behavior was investigated. The retention mechanism of basic drugs on the stationary phase was elucidated. The results indicate that both hydrophobic and cation-exchange interactions contribute to solute retention under most chromatographic conditions. The inherent Br?nsted-acid sites and also the adsorbed Lewis base anionic buffer constituents on accessible ZM surface Lewis acid sites play a role in the retention of ionized solutes by cation-exchange interaction. However, especially at high mobile phase pH, the retention of basic drugs depends mainly on hydrophobic interactions between solutes and support. Separations of the basic drugs on the C18PZM phase by a predominantly reversed-phase retention mode were very promising. The mixed-mode retention feature on this phase, as a result of the adsorbed Lewis base anionic buffer constituents acting as sites for cation-exchange, could also be very useful, e.g. for enhancing the chromatographic selectivity of such analytes. The C18PZM seems to be an excellent alternative to silica-based reversed-phase stationary phase for the separation of strongly basic solutes.  相似文献   

2.
In this study, an aqueous solution consisting of benzoic acid with low background conductivity and beta-cyclodextrin (beta-CD) of hydrophilic nature and the inclusion effect to benzoic acid were used as eluent for the ion-exclusion chromatographic separation of aliphatic carboxylic acids with different pKa values and hydrophobicity on a polymethacrylate-based weakly acidic cation-exchange resin in the H+ form. With increasing concentration of beta-cyclodextrin in the eluent, the retention times of the carboxylic acids decreased due to the increased hydrophilicity of the polymethacrylate-based cation-exchange resin surface from the adsorption of OH groups of beta-cyclodextrin. Moreover, the eluent background conductivity decreased with increasing concentration of beta-cyclodextrin in 1 mM benzoic acid, which could result in higher sensitivity for conductimetric detection. The ion-exclusion chromatographic separation of carboxylic acids with high resolution and sensitivity was accomplished successfully by elution with a 1 mM benzoic acid-10 mM cyclodextrin solution without chemical suppression.  相似文献   

3.
It was found that common cations (Na+, NH4+, K+, Mg2+ and Ca2+) could be strongly retained on an ODS stationary phase when aqueous solutions of carboxylic acids were used as eluents. The chromatographic conditions used in this work were the same as in common cation-exchange chromatography on a cation-exchange resin and the retention behavior of the above-mentioned cations on the ODS column was quite similar to that on a cation-exchange column. The retention behavior and mechanism have been investigated using a number of carboxylic acids as eluents. The retention mechanism of the cations in these experiments was considered to be a dynamic coating ion-exchange mechanism. The carboxylic acids in the mobile phase were coated onto the surface of the ODS stationary phase and formed a dynamic carboxylic acid functional layer which could act like the functional group layer of a carboxylic group cation exchanger.  相似文献   

4.
A glutamic acid-bonded silica (Glu-silica) stationary phase with cation-exchange properties was synthesized using l-glutamic acid as ligand and silica gel as matrix. The effects of solution pH value, salt concentration and metal ion on the retention of proteins were examined. The standard protein mixture was separated with a prepared chromatographic column and an iminodiacetic acid column, and compared. The influence of the binding capacity of an immobilized metal ion on the complexation of metal chelate column was studied. The results indicate that the obtained column displays cation-exchange characteristic and better separation ability for proteins. As fixing metal ion on the Glu-silica column, retention of proteins on the column is a cooperative interaction of metal chelate and cation-exchange. The stationary phase shows the typical metal chelate properties with the increase of the sorption capacity of immobilized metal ion.  相似文献   

5.
Three n-octadecylphosphonic acid-modified magnesia-zirconia reversed stationary phases (C18PZM) are prepared via the strong Lewis base interactions between organophosphonate and magnesia-zirconia composite. And two of them are end-capped by using trimethylchlorosilane as end-capping agent in different procedures. Stability studies at extreme high pH conditions (pH 9-12) show that both the non-endcapped and endcapped columns are quite stable at pH 12 mobile phase. The reversed-phase liquid chromatographic behavior of three C18PZM stationary phases are comparatively investigated in detail using a variety of basic compounds as probes. The retention of basic compounds on the three phases is studied over a wide range of pHs. And the possible retention mechanisms of basic compounds on the three stationary phases are discussed. The results show that the basic solutes retain by a hydrophobic and cation-exchange interaction mixed mechanism on three stationary phases when they are operated in eluents at pH values near to the pKa of the Brönsted conjugate acid form of the analyte, suggesting that inherent zirconol groups on ZM are not expected to interact with bases via cation-exchange interaction at lower pH. Nonetheless, the non-endcapped phase differs markedly from the edncapped ones in retention and selectivity of basic solutes using eluents at pH 4.1, implying a complex retention mechanism at this pH. The cation-exchange sites under such conditions are more likely due to the adsorbed Lewis base anionic buffer constituents (acetate) on accessible ZM surface sites than the chemisorbed phosphonate. Although the three phases exhibit very similar chromatographic behavior with eluents at pH 10.1, and show in general satisfactory separation of basic compounds and alkaloids studied, the performance for a specific analyte, however, differs largely from column to column.  相似文献   

6.
The retention mechanism of monocarboxylic acids on a cation-exchange resin column was investigated. It was assumed that both Donnan membrane equilibrium and adsorption equilibrium were involved in the chromatographic process. On the basis of the proposed mechanism, an equation was derived for correlating distribution coefficient, Kd, dissociation constant, Aa, and adsorption equilibrium constant, K, of the analyzed acid. By this approach, retention data for some aliphatic acids under different operating conditions were predicted. Results are reasonably in agreement with experiment.  相似文献   

7.
A highly cross-linked porous poly(styrene-divinylbenzene) resin was reacted with sulfuric acid to give strong cation-exchange resins with capacities from 0.2 to 1.9 mequiv./g. The retention behavior of mono- and dicar☐ylic acids on these resins was compared with results obtained from silica-based cation exchangers functionalized with alkylsulfonic acid or phenylsulfonic acid groups. The contribution of different retention mechanisms like ion exclusion, hydrophobic interaction and adsorption to the separation of the analytes on these chromatographic supports was discussed. Additionally the applicability of silica-based cation exchangers was tested in the field of silage analysis.  相似文献   

8.
研究了一些芳胺类化合物在1-萘甲膦酸改性氧化锆固定相上的色谱行为。分别考察了流动相中甲醇含量、缓冲液pH值和离子强度等对芳胺类化合物色谱保留的影响,并对这类化合物在该固定相上的保留机理进行了探讨。研究结果表明,芳胺类化合物在该固定相上表现出反相和阳离子交换的混合保留模式。以pH 10.1的Tris-甲醇(60/40,V/V)溶液为流动相,在1-萘甲膦酸改性氧化锆固定相上成功分离了间苯二胺、邻甲苯胺、N-甲苯胺、对硝基苯胺、邻硝基苯胺和α-甲萘胺6种芳胺类化合物。  相似文献   

9.
This work describes chromatographic properties of reversed-phase/cation-exchange/anion-exchange trimodal stationary phases. These stationary phases were based on high-purity porous spherical silica particles coated with nano-polymer beads using an electrostatically driven self-assembly process. The inner-pore area of the material was modified covalently with an organic layer that provided both reversed-phase and anion-exchange properties while the outer surface was coated with nano-sized polymer beads with strong cation-exchange characteristics. This design ensured spatial separation of the anion-exchange and the cation-exchange regions, and allowed reversed-phase, anion-exchange and cation-exchange retention mechanisms to function simultaneously. Chromatographic evaluation of ions and small molecules suggested that retention of ionic analytes was influenced by the ionic strength, pH, and mobile phase organic solvent content, and governed by both ion-exchange and hydrophobic interactions. Meanwhile, neutral analytes were retained by hydrophobic interaction and was mainly affected by mobile phase organic solvent content. Depending on the specific application, selectivity could be optimized by adjusting the anion-exchange/cation-exchange capacity ratio (selectivity), which was achieved experimentally by using porous silica particles with different surface areas.  相似文献   

10.
The retention and selectivity of the chromatographic separation of basic (cationic) analytes on a polybutadiene-coated zirconia (PBD-ZrO2) stationary phase have been studied in greater detail than in previous studies. These separations are strongly influenced by the chemistry of the accessible surface of zirconia. In the presence of buffers which contain hard Lewis bases (e.g., phosphate, fluoride, carboxylic acids) zirconia's surface becomes negatively charged due to adsorption of the buffer anion at the hard Lewis acid sites. Consequently, under most conditions (e.g., neutral pH), cationic analytes undergo both hydrophobic and cation-exchange interactions. This mixed-mode retention process generally leads to greater retention factors for cations relative to those on silica-based reversed phases despite the lower surface areas of the zirconia phase, but, more importantly, adsorption of hard Lewis bases can be used to control the chromatographic selectivity for cationic analytes on these zirconia-based stationary phases. In contrast to our prior work, here we show that when mixed-mode retention takes place, both retention and selectivity are easily adjusted by changing the type of hard Lewis base buffer anion, the type of buffer counter-ion (e.g., sodium, potassium, ammonium), the pH, and the ionic strength of the eluent as well as the type and amount of organic modifier.  相似文献   

11.
The chromatographic retention mechanism describing relationship between retention factor and concentration of Cu2+(l ‐phenylalanine)2 using chiral ligand mobile phase was investigated and eight mandelic acid derivatives were enantioseparated by chiral ligand exchange chromatography. The relationship between retention factor and concentration of the Cu2+(l ‐phenylalanine)2 complex was proven to be in conformity with chromatographic retention mechanism in which chiral discrimination occurred both in mobile and stationary phase. Different copper(II) salts, chiral ligands, organic modifier, pH of aqueous phase, and conventional temperature on retention behavior were optimized. Eight racemates were successfully enantioseparated on a common reversed‐phase column with an optimized mobile phase composed of 6 mmol/L of l ‐phenylalanine or N,N‐dimethyl‐l ‐phenylalanine and 3 mmol/Lof copper(II) acetate or copper(II) sulfate aqueous solution and methanol.  相似文献   

12.
The high-speed ion-exclusion chromatographic determination of dissolved carbon dioxide, i.e., carbonic acid, hydrogencarbonate or carbonate, with conductivity detection was obtained using a small column packed with a weakly acidic cation-exchange resin in the H+-form (40 mm long x 4.6 mm i.d., 3 microm-particle and 0.1 meq./ml-capacity). Two different ion-exchange resin columns, which were a strongly acidic cation-exchange resin in the K+-form and a strongly basic anion-exchange resin in the OH- -form, were connected after the separation column. The sequence of columns could convert dissolved carbon dioxide to KOH having high conductivity response. The enhancement effect for dissolved carbon dioxide could retain even on the vast chromatographic runs, by using the enhancement columns with high ion-exchange capacity above 1.0 meq./ml. The retention time was in 60 s at flow-rate of 1.2 ml/min. The calibration graph of dissolved carbon dioxide estimated as H2CO3- was linear in the range of 0.005-10 mM. The detection limit at signal to noise of 3 was 0.15 microM as H2CO3-. This method was applicable to several rainwater and tap water samples.  相似文献   

13.
A novel type of silica-based sulfonate-modified reversed phase ((-)SO3-HC-C8) has been synthesized; it is based on a newly developed acid stable "hyper-crosslinked" C8 derivatized reversed phase, denoted HC-C8. The (-)SO3-HC-C8 phases containing controlled amounts of sulfonyl groups were made by sulfonating the aromatic hyper-crosslinked network of the HC-C(8) phase at different temperatures. The (-)SO3-HC-C8 phases are only slightly less hydrophobic than the parent HC-C8 phase. The added sulfonyl groups provide a unique strong cation-exchange selectivity to the hydrophobic hyper-crosslinked substrate as indicated by the very large C coefficient as shown through Snyder's hydrophobic subtraction reversed-phase characterization method. This cation-exchange activity clearly distinguishes the sulfonated phase from all other reversed phases as confirmed by the very high values of Snyder's column comparison function F(s). In addition, as was found in previous studies of silica-based and zirconia-based reversed phases, a strong correlation between the cation-exchange interaction and hydrophobic interaction was observed for these sulfonated phases in studies of the retention of cationic solutes. The overall chromatographic selectivity of these (-)SO3-HC-C8 phases is greatly enhanced by its high hydrophobicity through a "hydrophobically assisted" ion-exchange retention process.  相似文献   

14.
A simple and effective chromatographic method with suppressed conductivity detection was developed and validated to determine dissolved samples of octadecyltrimethylammonium bromide (C18H37N+Me3Br, ODTAB) for purity testing. A response surface methodology generated with a Doehlert matrix design was applied to optimize the chromatographic and detection conditions in ion-exchange chromatography (IEC) with conductivity detection in the chemical suppression mode. A three-factor Doehlert design was performed to fit a second-order model and jointly optimize the peak intensity and shorten analysis time through a global desirability function. Regenerant flow rate, volume fraction of acetonitrile in the acidic eluent and its flow rate were studied at seven, five and three levels, respectively. The optimized separation and detection conditions were accomplished by using a cation-exchange column eluted at 0.5 mL min−1 with an isocratic mobile phase composed of CH3CN and 25 mN H2SO4, 82/18 (v/v). Chemical suppression of ionic conductivity was performed by 100 mN tetrabutylammonium hydroxide (TBAOH) as a regenerant at a flow-rate of 4.0 mL min−1. Remarkably good agreement was found between predicted and experimental values of signal intensity and chromatographic retention. With the developed method, a linear calibration curve of ODTA+ as bromide salt from 5 to 1000 ppm was obtained using hexadecyltrimethylammonium bromide as internal standard. The estimated limit of detection was 0.3 ppm (S/N = 3). The effectiveness of electrochemically suppressed conductivity detection of ODTA+ was also demonstrated, thus making easier the whole detection operation and instrumental needs as well.  相似文献   

15.
Influence of acidic eluent on retention behaviors of common anions and cations by ion-exclusion/cation-exchange chromatography (ion-exclusion/CEC) were investigated on a weakly acidic cation-exchange resin in the H(+)-form with conductivity. Sensitivities of analyte ions, especially weak acid anions (F(-) and HCOO(-)), were affected with degree of background conductivity level with pK(a1) (first dissociation constant) of acid in eluent. The retention behaviors of anions and cations were related to that of elution dip induced after eluting acid to separation column and injecting analyte sample. These results were largely dependent on the natures of acid as eluent. Through this study, succinic acid as the eluent was suitable for simultaneous separation of strong acid anions (SO(4)(2-), Cl(-), NO(3)(-) and I(-)), weak acid anions (F(-), HCOO(-) and CH(3)COO(-)), and cations (Na(+), K(+), NH(4)(+), Mg(2+) and Ca(2+)). The separation was achieved in 20 min under the optimum eluent condition, 20 mM succinic acid/2 mM 18-crown-6. Detection limits at S/N=3 ranged from 0.10 to 0.51 microM for strong acid anions, 0.20 to 5.04 microM for weak acid anions and 0.75 to 1.72 microM for cations. The relative standard deviations of peak areas in the repeated chromatographic runs (n=10) were in the range of 1.1-2.9% for anions and 1.8-4.5% for cations. This method was successfully applied to hot spring water containing strong acid anions, weak acid anions and cations, with satisfactory results.  相似文献   

16.
The harmful health effects caused by phthalic acid esters have been supported from the increasing scientific evidence, developing the efficient methodologies to monitor the levels of phthalic acid esters in various foods become especially important from the aspects of human exposure assessment and their migration mechanistic understanding. In this study, quantitative structure‐retention relationship studies on both the gas and liquid chromatographic retention times of 23 phthalic acid esters were performed by genetic function approximation, and the optimal quantitative structure‐retention relationship models (r2 > 0.980, r2CV > 0.960, and r2pred > 0.865) passed the statistical tests of cross‐validation, randomization, external prediction, Roy′ rm2 metrics, Golbraikh‐Tropsha′ criteria and applicability domain. The established predictive models elucidate the structural requirements for the retention of phthalic acid esters over different chromatographic columns, which were finally used to predict the retention times of 11 new phthalic acid esters. Hopefully, this work could provide useful guidelines for better understanding and accurate prediction of the retention behavior of undetermined phthalic acid esters when lacking standard samples or under poor experimental conditions, and make the simultaneous identification and quantification of numerous phthalic acid esters possible.  相似文献   

17.
研究了非抑制型阳离子交换色谱中色谱柱温度(25~50℃)对碱金属离子(Li+、Na+、K+、Rb+)和碱土金属离子(Mg2+、Ca2+、Sr2+)以及NH4+保留的影响。在Shim-pack IC-C1磺酸型阳离子交换柱上,以硝酸为流动相分离碱金属离子,以乙二胺或乙二胺-草酸(柠檬酸)为流动相分离碱土金属离子,随着色谱柱温度的升高,碱金属和碱土金属离子的保留时间均增长,其范特霍夫曲线具有良好的线性关系,斜率为负值,表明在此条件下碱金属和碱土金属离子的保留为吸热过程。在Shim-pack IC-SC1羧酸型阳离子交换柱上,以硫酸为流动相同时分离碱金属和碱土金属离子,随着色谱柱温度的升高,Mg2+、Ca2+的保留时间增长,而K+、Rb+的保留时间缩短,Li+、Na+、NH4+的保留时间基本不变。在此条件下,Mg2+、Ca2+、K+和Rb+的范特霍夫曲线具有良好的线性关系,其中Mg2+和Ca2+的曲线斜率为负值,K+和Rb+的曲线斜率为正值,表明Mg2+和Ca2+的保留表现为吸热过程,K+和Rb+的保留表现为放热过程。研究表明在不同固定相和流动相条件下,色谱柱温度对碱金属和碱土金属离子保留行为的影响不同。  相似文献   

18.
Li R  Chen GL  Zhao WM 《Annali di chimica》2004,94(12):939-949
A weak cation-exchanger (XIDACE-WCX) has been synthesized by the indirect method. The chromatographic characteristics of the synthesized packing was studied in detail. The standard protein mixture and lysozyme from egg white were separated with the prepared chromatographic column. The chromatographic thermodynamics of proteins was studied in a wide temperature range. Thermodynamic parameters standard enthalpy change (deltaH0) and standard entropy change (deltaS0) and compensation temperature (beta) at protein denaturation were determined in the chromatographic system. By using obtained deltaS0, the conformational change of proteins was judged in the chromatographic process.The linear relationship between deltaH0 and deltaS0 can be used to identify the identity of the protein retention mechanism in the weak cation-exchange chromatography. The interaction between weak cation-exchanger and metal ions was investigated. Several metal chelate columns were prepared. The effects of introducing metal ion into the naked column on protein retention and the retention mechanism of proteins in the metal chalet affinity chromatography were discussed.  相似文献   

19.
Muhammad Amin 《Talanta》2007,71(4):1470-1475
A convenient ion chromatography method has been proposed for the routine and simple determination of anions (Cl, SO42− and NO3) and/or cations (Na+, NH4+, K+, Mg2+ and Ca2+) using a single pump, a single eluent and a single detector. The present system used cation-exchange and anion-exchange columns connected in series via two 6-port switching valves or a single 10-port valve. The connection order of the ion-exchange columns could be varied by switching the valve(s). The present system therefore allowed the separation of either cations or anions in a single chromatographic run. While one ion-exchange column is being operated, the other ion-exchange column is being conditioned, i.e., the columns are always ready for analysis at any time. When 2.4 mM 5-sulfosalicylic acid was used as the eluent, the three anions and the five cations could be separated on the anion-exchange column and cation-exchange column, respectively. In order to obtain the separations of the target ions, the injection valve was placed between the two columns. Complete separations of the above anions or cations were demonstrated within 10 min each. The detection limits at S/N = 3 were 19-50 ppb (μg/l) for cations and 10-14 ppb for anions. The relative standard deviations of the analyte ions were less than 1.1, 2.9 and 2.8% for retention time, peak area and peak height, respectively. This proposed technique was applied to the determination of common anions and cations in river water samples.  相似文献   

20.
蛋白质在合成阳离子交换剂上的色谱特性研究   总被引:1,自引:0,他引:1  
李蓉  陈国亮  赵文明 《色谱》2004,22(2):134-137
用国产材料按间接法合成了螯合型弱阳离子交换剂,详细研究了合成填料的色谱性能,并与商品柱的分离效能进行了比较;在宽温度范围内研究了蛋白质在弱阳离子交换系统中的色谱热力学,测定了蛋白质在色谱过程变性时的热力学参数 (△H0和△S0) 和补偿温度β,提出用标准熵变△S0判断蛋白质的构象变化和用△H0与△S0的补偿关系鉴定蛋白质各变体在色谱系统保留机理的同一性。考察了螯合型弱阳离子交换剂与金属离子的作用,研究了蛋白质在金属螯合色谱中的保留机理。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号