首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 399 毫秒
1.
A liquid chromatography–electrospray-tandem mass spectrometry (LC–ESI-MS–MS) method based on the detection of biomarker peptides from allergenic proteins was devised for confirming and quantifying peanut allergens in foods. Peptides obtained from tryptic digestion of Ara h 2 and Ara h 3/4 proteins were identified and characterized by LC–MS and LC–MS–MS with a quadrupole-time of flight mass analyzer. Four peptides were chosen and investigated as biomarkers taking into account their selectivity, the absence of missed cleavages, the uniform distribution in the Ara h 2 and Ara h 3/4 protein isoforms together with their spectral features under ESI-MS–MS conditions, and good repeatability of LC retention time. Because of the different expression levels, the selection of two different allergenic proteins was proved to be useful in the identification and univocal confirmation of the presence of peanuts in foodstuffs. Using rice crispy and chocolate-based snacks as model food matrix, an LC–MS–MS method with triple quadrupole mass analyzer allowed good detection limits to be obtained for Ara h2 (5 μg protein g−1 matrix) and Ara h3/4 (1 μg protein g−1 matrix). Linearity of the method was established in the 10–200 μg g−1 range of peanut proteins in the food matrix investigated. Method selectivity was demonstrated by analyzing tree nuts (almonds, pecan nuts, hazelnuts, walnuts) and food ingredients such as milk, soy beans, chocolate, cornflakes, and rice crispy. Figure ESI-QTOF-MS mass spectrum of Ara h3/4 triptig digest  相似文献   

2.
In this work, two analytical methods based on liquid chromatography coupled to electrospray time-of-flight mass spectrometry (LC/ESI-TOFMS) and tandem mass spectrometry (LC/ESI-MS/MS) are described for the identification, confirmation and quantitation of three insecticides non-authorized in the European Union (nitenpyram, isocarbophos and isofenphos-methyl) but detected in recent monitoring programmes in pepper samples. The proposed methodologies involved a sample extraction procedure using liquid-liquid partition with acetonitrile followed by a cleanup step based on dispersive solid-phase extraction. Recovery studies performed on peppers spiked at different fortification levels (10 and 50 microg kg(-1)) yielded average recoveries in the range 76-100% with relative standard deviation (RSD) (%) values below 10%. Identification, confirmation and quantitation were carried out by LC/TOFMS and LC/MS/MS using a hybrid triple quadrupole linear ion trap (QqLIT) instrument in multiple-reaction monitoring (MRM) mode. The obtained limits of quantitation (LOQs) were in the range 0.1-5 microg kg(-1), depending on each individual technique. Finally, the proposed methods were successfully applied to the analysis of suspected pepper samples.  相似文献   

3.
Complex matrices commonly affect the sensitivity and selectivity of liquid chromatography-mass spectrometry (LC-MS) analysis. Thus, selective sample enrichment strategies are useful particularly to analyze organic biomarkers present in low abundance in samples. A selective immunomagnetic extraction procedure to isolate trace peanut allergen protein Ara h3/4 from breakfast cereals combined with microwave-assisted tryptic digestion and liquid chromatography-electrospray ion-trap tandem mass spectrometry (LC-ESI-IT-MS/MS) measurement was developed. Using protein A-coated magnetic bead (MB) support, anti-Ara h3/4 monoclonal antibodies (Abs) were used as selective capture molecules. The results obtained by LC-ESI-IT-MS/MS in terms of limit of detection (3mg peanuts/kg matrix) and a significantly reduced matrix effect demonstrated that the Ab-coated magnetic bead was very effective to selectively trap Ara h3/4 protein in breakfast cereals. The magnetic bead-based sample treatment followed by LC-IT-MS/MS method here developed can be proposed as very rapid and powerful confirmatory analytical method to verify the reliability of enzyme-linked immunosorbent assay (ELISA) screening methods, since the magnetic bead-LC-IT-MS/MS method combines good sensitivity to the identification capabilities of mass spectrometry.  相似文献   

4.
A rapid method is presented for the determination of 4 nitroimidazoles in poultry and swine muscle and eggs by liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS). Samples were extracted with acetonitrile, then evaporated the organic phase. After filtration, the extract was directly injected into the LC/ESI-MS/MS system. The LC separation was made on a C8 column by applying a gradient composed of water and acetonitrile. Overall average recoveries ranged from 50-86% for egg, 66-115% for poultry muscle, and 79-111% for swine muscle. The decision limits ranged from 0.05-0.25 microg/kg for egg, 0.07-0.27 microg/kg for poultry muscle, and 0.07-0.26 microg/kg for swine muscle; and detection capabilities ranged from 0.51-0.68 microg/kg for egg, 0.41-0.75 microg/kg for poultry muscle, and 0.53-0.78 microg/kg for swine muscle.  相似文献   

5.
Flow injection analysis (FIA) with ESI-MS and ion chromatography (IC) with inductively coupled plasma-MS (ICP-MS) as the complementary technique have been explored for the determination of metal ions as their metal-EDTA complexes. ESI-MS enabled the identification of metal-EDTA complexes such as [Mn(EDTA)](2-), [Co(EDTA)](2-), [Ni(EDTA)](2-), [Cu(EDTA)](2-), [Zn(EDTA)](2-), [Pb(EDTA)](2-), and [Fe(EDTA)](1-) and their MS spectral showed that these metal-EDTA complexes were present in solution. Based on the ESI-MS, ion chromatographic separation and ICP-MS detection of these complexes are possible because IC-ICP-MS requires stable metal-EDTA complex during the chromatographic separation. The separation of these metal-EDTA complexes was achieved on an anion-exchange column with a mobile phase containing 30 mM NH(4)(HPO(4))(2) at pH 7.5 within 7 min with ICP-MS providing element specific detection. The ICP-MS LODs for the metal-EDTA were in the range of 0.1-0.5 microg/L with the exception of Fe (15 microg/L). The proposed method was a simple procedure for sample processing, using direct injection of sample without removal of sample matrix and was successfully applied to the determination of metal-EDTA complexes in real samples.  相似文献   

6.
Electrospray ionization mass spectrometry is used in lipidomics studies. The present research established a top-down liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) shotgun analysis method for phospholipids (PLs) using a normal-phase column or a C30 reverse-phase column with the data-dependent MS/MS scanning mode. A normal-phase column can separate most of the major different classes of PLs. By using LC/ESI-MS/MS with a normal-phase column, approximately 50 molecular species were identified in a PL mixture from rat liver. When the reverse-phase column was used, the PLs could be separated depending on their hydrophobicity, essentially the length of their fatty acyl chains and the number of unsaturated bonds in them. The LC/ESI-MS/MS method using a C30 reverse-phase column was applied to phosphatidylcholine (PC) and phosphatidylethanolamine (PE) mixtures as test samples. Molecular species with the same molecular mass but with different pairs of fatty acyl chains were separately identified. As a result, about 60 PC and 50 PE species were identified. PLs from rat liver were subjected to LC/ESI-MS/MS using the C30 reverse-phase column and about 110 molecular species were identified. Off-line two-dimensional LC/ESI-MS/MS with the normal-phase and C30 reverse-phase columns allowed more accurate identification of molecular species by using one-dimensional C30 reverse-phase LC/ESI-MS/MS analysis of the collected fractions.  相似文献   

7.
Electrospray ionization multi-stage tandem mass spectrometry (ESI-MS(n)) and liquid chromatography coupled with on-line mass spectrometry (LC/MS/MS) were applied to characterize saponins in crude extracts from Panax ginseng. The MS(n) data of the [M - H](-) ions of saponins can provide structural information on the sugar sequences of the saccharide chains and on the sapogins of saponins. By ESI-MS(n), non-isomeric saponins and isomeric saponins with different aglycones can be determined rapidly in plant extracts. LC/MS/MS is a good complementary analytical tool for determination of isomeric saponins. These approaches constitute powerful analytical tools for rapid screening and structural assignment of saponins in plant extracts.  相似文献   

8.
A liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method for measurement of aflatoxins B1, B2, G1, and G2 in maize is described. Aflatoxins (AFs) were extracted from 1 g samples by using tri-portions of acetonitrile/water (80:20, v/v) (10 + 7 + 7 mL), and 2/5 of the extract diluted to 500 mL by water was cleaned up with a 100 mg Carbograph-4 cartridge. After the addition of the internal standard AFM1, the final extract was analyzed by LC/ESI-MS/MS in positive ion mode using multiple reaction monitoring with a triple-quadrupole instrument. A C(18) column thermostatted at 45 degrees C with a mobile phase gradient of acetonitrile/water with 2 mmol/L ammonium formate was used. Although the matrix suppression effect was negligible, quantitation was achieved by an external calibration procedure using matrix-matched standard solutions to improve accuracy. Sample recoveries at four spiking levels ranged from 81 to 101% (relative standard deviation (RSD) 相似文献   

9.
A simple and inexpensive liquid chromatography/mass spectrometry (LC/MS) method was developed for the quantitation of acrylamide in various food products. The method involved spiking the isotope-substituted internal standard (1-C13 acrylamide) onto 6.00 g of the food product, adding 40 mL distilled/deionized water, and heating at 65 degrees C for 30 min. Afterwards, 10 mL ethylene dichloride was added and the mixture was homogenized for 30 s and centrifuged at 2700 x g for 30 min, and then 8 g supernatant was extracted with 10, 5, and 5 mL portions of ethyl acetate. The extracts were combined, dried with sodium sulfate, and concentrated to 100-200 microL. Acrylamide was determined by analysis of the final extract on a single quadrupole, bench-top mass spectrometer with electrospray ionization, using a 2 mm id C18 column and monitoring m/z = 72 (acrylamide) and m/z = 73 (internal standard). For difficult food matrixes, such as coffee and cocoa, a solid-phase extraction cleanup step was incorporated to improve both chromatography and column lifetime. The method had a limit of quantitation of 10 ppb, and coefficients of determination (r2) for calibration curves were typically better than 0.998. Acceptable spike recovery results were achieved in 11 different food matrixes. Precision in potato chip analyses was 5-8% (relative standard deviation). This method provides an LC/MS alternative to the current LC/MS/MS methods and derivatization gas chromatography/mass spectrometry methods, and is applicable to difficult food products such as coffee, cocoa, and high-salt foods.  相似文献   

10.
Twenty proteinogenic amino acids (AAs) were determined without derivatization using flow injection analysis followed by electrospray ionization mass spectrometry and tandem mass spectrometry (ESI-MS and ESI-MS/MS) and electrospray ionization high-field asymmetric waveform ion mobility mass spectrometry and tandem mass spectrometry (ESI-FAIMS-MS and ESI-FAIMS-MS/MS), in positive and negative ionization modes. Three separate sets of ESI-FAIMS conditions were used for the separation and detection of the 20 AAs. Typically ESI-FAIMS-MS showed somewhat improved sensitivity and significantly better signal-to-noise ratios than ESI-MS mainly due to the elimination of background noise. However, the difference between ESI-FAIMS-MS and ESI-MS/MS was significantly less. ESI-FAIMS was able to partially or completely resolve all the isobaric amino acid overlaps such as leucine, isoleucine and hydroxyproline or lysine and glutamine. Detection limits for the amino acids in ESI-FAIMS-MS mode ranged from 2 ng/mL for proline to 200 ng/mL for aspartic acid. Overall, ESI-FAIMS-MS is the preferred method for the quantitative analysis of AAs in a hydrolyzed yeast matrix.  相似文献   

11.
Direct quantitation of glutathione S-transferase (GST) isoforms [alpha (GST-A) and micro (GST-M)] in human liver cytosol was achieved by liquid chromatography/tandem mass spectrometry (LC/ESI-MS/MS) analysis of signature peptides of GST-A and GST-M and their corresponding stable isotopic peptide internal standards via multiple reaction monitoring (MRM). The selection of signature peptides was performed via trypsin digestion of commercially available cDNA-expressed GST-A1 and GST-M1, followed by LC/ESI-MS/MS with an ion trap mass spectrometer and sequencing with the TurboSEQUEST application. Quantitative analysis of the selected signature peptides in the multi-reaction monitoring (MRM) mode was performed using a triple-quadruple mass spectrometer. A series of human cytosol samples was quantitatively analyzed for levels of GST-A and GST-M. The total level of GST-A and GST-M obtained from this LC/ESI-MS/MS method was well correlated with the total level of GST determined by the 1-chloro-2,4-dinitrobenzene (CDNB) method.  相似文献   

12.
A method for the quantification of clindamycin in animal plasma using high-performance liquid chromatography combined with electrospray ionization mass spectrometry (LC/ESI-MS/MS) is presented. Lincomycin is used as the internal standard. The sample preparation includes a simple deproteinization step with trichloroacetic acid. Chromatographic separation is achieved on an RP-18 Hypersil column using gradient elution with 0.01 M ammonium acetate and acetonitrile as mobile phase. Good linearity was observed in the range 0-10 microg ml(-1). The limit of quantification of the method is 50 ng ml(-1) and the limit of detection is 1.3 ng ml(-1). The method was shown out to be of use for pharmacokinetic studies of clindamycin formulations in dogs.  相似文献   

13.
The quantitative determination of nucleotides from DNA modified by styrene oxide is described using a combination of inductively coupled plasma high-resolution mass spectrometry (ICP-HRMS) and electrospray ionization mass spectrometry (ESI-MS), both interfaced to reversed-phase high-performance liquid chromatography (HPLC). LC/ICP-MS (resolution > 1500 to discriminate against 15N16O+ and 14N16OH+) was employed to determine quantitatively the content of modified nucleotides in standard solutions based on the signal of phosphorus; phosphoric acid served as an internal standard. By means of the standard addition technique the sensitivity of the LC/ESI-MS approach was subsequently determined. Since a comparison of UV, ICP and ESI-MS data suggested that in ESI-MS the ionization efficiency of the adducts is identical within the error limits, quantitative determination of all adducts is possible. For LC/ESI-MS with single ion monitoring, the detection limit for styrene oxide adducts of nucleotides was determined to be 20 pg absolute or 14 modified in 10(8) unmodified nucleotides in a 5 micrograms DNA sample, which comes close to the best methods available for the detection of chemical modifications in DNA.  相似文献   

14.
Liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is one of the most prominent analytical techniques owing to its inherent selectivity and sensitivity. In LC/ESI-MS/MS, chemical derivatization is often used to enhance the detection sensitivity. Derivatization improves the chromatographic separation, and enhances the mass spectrometric ionization efficiency and MS/MS detectability. In this review, an overview of the derivatization reagents which have been applied to LC/ESI-MS/MS is presented, focusing on the applications to low molecular weight compounds.  相似文献   

15.
A sensitive liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method for the quantitative determination of ochratoxin A (OTA) in kidney samples was developed. Ochratoxin B (OTB) was used as internal standard. Extraction of homogenized kidney samples was done by adding a chloroform/phosphoric acid mixture. Due to restriction of the sample size, less chloroform could be used than in previously described methods. Two different columns for clean-up were compared: strong anion exchange (Bond Elut SAX) and Extrelut NT columns. The high-performance liquid chromatography (HPLC) was used with gradient elution consisting of variable mixtures of formic acid (0.3%) in acetonitrile and formic acid (0.3%) in water. The mass spectrometer was operated in the positive ESI mode using multiple reaction monitoring. For OTA the precursor ion was m/z 404 while the product ions were at m/z 239 and m/z 341. For OTB the precursor ion was m/z 370 while the product ions were at m/z 205 and at m/z 324. A calibration curve of fortified kidney samples was used to quantify OTA. Method validation was performed according to Commission Decision 2002/657/EC. Decision limit (CCalpha), detection capability (CCbeta), precision, bias, trueness, specificity and measurement uncertainty were determined. In general, the best results were obtained using SAX clean-up. CCalpha and CCbeta were 0.11 and 0.25 microg kg(-1), respectively. Within-laboratory reproducibility (% CV) was 9, 9, and 5% for OTA-fortified kidney samples of 0.5, 1, and 2.5 microg kg(-1), respectively. Trueness (%) was 75, 69, and 57% for OTA-fortified kidney samples at 0.25, 0.5, and 1 microg kg(-1), respectively. Measurement uncertainty and expanded uncertainty were 14.85 and 29.70%, respectively. All criteria as laid down in Commission Decision 2002/657/EC were fulfilled. Therefore, this LC/ESI-MS/MS method can be used to monitor kidneys for OTA in the framework of Council Directive No. 96/23/EC.  相似文献   

16.
The behaviour of 5-methyl-2'-deoxycytidine (m(5)dCyd, claimed to be a potential marker for leukaemia) during the electrospray process was studied. In particular, considerations concerning the effect of solution chemistry (e.g. analyte concentration, pH, etc.) on electrospray ionization mass spectra were drawn. Furthermore, a procedure using liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) for the determination of urinary m(5)dCyd is described. The method is simple, sensitive and highly specific. The pre-treatment procedure gave an average recovery of 79% (relative standard deviation (RSD) of 3%). Method performance was evaluated on spiked urine samples covering the concentration range from 50 ng/mL to 10 microgram/mL, the same as that of an existing inhibition ELISA method. Contrary to findings based on this immunoassay technique, urinary m(5)dCyd in healthy individuals was not detectable and did not increase in the presence of the malignant disease.  相似文献   

17.
A quantitative liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method was developed for the analysis of the explosive, octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX). In negative ionization mode, HMX forms an acetate adduct ion [M + CH(3)COO](-), m/z 355, in the presence of a small amount of acetic acid in the mobile phase. The ESI collision-induced dissociation (CID) spectrum of m/z 355 was acquired and the transitions m/z 355 --> 147 and m/z 355 --> 174 were chosen for the determination of HMX in samples. Using this quantification technique, the method detection limit was 1.57 microg/L and good linearity was achieved in the range 5-500 microg/L. This method will help to unambiguously analyze environmentally relevant concentrations of HMX.  相似文献   

18.
A rapid analytical method based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) using electrospray ionization in negative ion detection mode was developed for the analysis of underivatized iodoacetic acid in water. The method was applied to model reaction mixtures in the study of the formation of iodoacetic acid after chlorinated tap water was boiled in the presence of potassium iodide or iodized table salt. Samples can be directly analyzed by the LC/MS/MS system without extraction or chemical derivatization. Limit of detection was determined to be 0.3 microg/L (or 0.3 ng/mL) and limit of quantitation was about 1 microg/L (1 ng/mL).  相似文献   

19.
A sensitive method using liquid chromatography with electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) was developed and validated to quantify and confirm 13 pesticides, including aldicarb sulfoxide, aldicarb sulfone, oxamyl, methomyl, formetanate, 3-hydroxycarbofuran, carbendazim, thiabendazole, aldicarb, propoxur, carbofuran, carbaryl, and methiocarb, in soy-based infant formula. Data acquisition under MS/MS was achieved by applying multiple reaction monitoring of 2 fragment ion transitions to provide a high degree of sensitivity and selectivity for both quantitation and confirmation. Different approaches to constructing calibration curves were compared and discussed to address issues of the extraction efficiency or recovery, and matrix effects. Matrix-matched standard calibration curves with the use of isoprocarb as an internal standard were finally used to achieve the best accuracy of the method. Under most circumstances, recoveries of 13 pesticides, spiked at 5.0, 25.0, and 45.0 microg/kg, were close to 100%. The method detection limits (signal-to-noise ratio > or =3:1; microg/kg) of 13 pesticides were 0.2 for thiabendazole and methiocarb, 0.6 for aldicarb, and 0.1 for the others.  相似文献   

20.
Qualitative and quantitative analyses of phenolic compounds are of interest for both medicinal and food plants. In the present work, the phenolic fraction from Yucca schidigera, a plant bearing the GRAS (Generally Recognized as Safe) label approved by the US Food and Drug Administration, was studied. Crude extracts of Y. schidigera bark were investigated by liquid chromatography/UV spectrophotometry with diode-array detection, liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS), in order to develop and optimize simple and rapid techniques to determine both stilbenes and yuccaols for the purposes of quality control of collected material. With optimal LC and MS conditions, stilbenes and yuccaols were quantified with all the proposed methods and the results were compared. Sensitivity was evaluated and the results indicated that MS/MS detection in the multiple reaction monitoring mode is easily applicable to this plant and allows the rapid and direct identification and quantification of these peculiar compounds in crude plant extracts.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号