首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A microfluidic approach for rapid bioluminescent real-time detection of single nucleotide polymorphism (SNP) is presented. The method is based on single-step primer extension using pyrosequencing chemistry to monitor nucleotide incorporations in real-time. The method takes advantage of the fact that the reaction kinetics differ between matched and mismatched primer-template configurations. We show here that monitoring the initial reaction in real time accurately scores SNPs by comparing the initial reaction kinetics between matched and mismatched configurations. Thus, no additional treatment is required to improve the sequence specificity of the extension, which has been the case for many allele-specific extension assays. The microfluidic approach was evaluated using four SNPs. Three of the SNPs included primer-template configurations that have been previously reported to be difficult to resolve by allele-specific primer extension. All SNPs investigated were successfully scored. Using the microfluidic device, the volume for the bioluminescent assay was reduced dramatically, thus offering a cost-effective and fast SNP analysis method.  相似文献   

2.
Xia F  Jin W  Yin X  Fang Z 《Journal of chromatography. A》2005,1063(1-2):227-233
A novel electrochemical method with a microfluidic device was developed for analysis of single cells. In this method, cell injection, loading and cell lysis, and electrokinetic transportation and detection of intracellular species were integrated in a microfluidic chip with a double-T injector coupled with an end-channel amperometric detector. A single cell was loaded at the double-T injector on the microfluidic chip by using electric field. Then, the docked cell was lysed by a direct current electric field strength of 220 V/cm. The analyte of interest inside the cell was electrokinetically transported to the detection end of separation channel and was electrochemically detected. External standardization was used to quantify the analyte of interest in individual cells. Ascorbic acid (AA) in single wheat callus cells was chosen as the model compound. AA could be directly detected at a carbon fiber disk bundle electrode. The selectivity of electrochemical detection made the electropherogram simple. The technique described here could, in principle, be applied to a variety of electroactive species within single cells.  相似文献   

3.
The zebrafish embryo is a small, cheap, whole-animal model which may replace rodents in some areas of research. Unfortunately, zebrafish embryos are commonly cultured in microtitre plates using cell-culture protocols with static buffer replacement. Such protocols are highly invasive, consume large quantities of reagents and do not readily permit high-quality imaging. Zebrafish and rodent embryos have previously been cultured in static microfluidic drops, and zebrafish embryos have also been raised in a prototype polydimethylsiloxane setup in a Petri dish. Other than this, no animal embryo has ever been shown to undergo embryonic development in a microfluidic flow-through system. We have developed and prototyped a specialized lab-on-a-chip made from bonded layers of borosilicate glass. We find that zebrafish embryos can develop in the chip for 5 days, with continuous buffer flow at pressures of 0.005-0.04 MPa. Phenotypic effects were seen, but these were scored subjectively as 'minor'. Survival rates of 100% could be reached with buffer flows of 2 μL per well per min. High-quality imaging was possible. An acute ethanol exposure test in the chip replicated the same assay performed in microtitre plates. More than 100 embryos could be cultured in an area, excluding infrastructure, smaller than a credit card. We discuss how biochip technology, coupled with zebrafish larvae, could allow biological research to be conducted in massive, parallel experiments, at high speed and low cost.  相似文献   

4.
Calpains are unique calcium-dependent thiol proteases that have been proposed to participate in a number of physiological processes including signal transduction and protein turnover in skeletal muscle. Calpains exist in two major forms. Interestingly, the two forms of protease show no significant difference in their action on various substrates. The only demonstrable difference in their activity involves the concentration of calcium required for activation. Both mu- and m-calpains typically achieve half maximal activation at 50 microM and 0.7 mM calcium, respectively. The focus of this study was to examine the action of both forms of calpain on casein substrates and assess whether any differences could be observed in the resulting peptide finger print using capillary electrophoresis. Purified mu- and m-calpain were incubated for various lengths of time with Oregon Green labeled alphas- and beta-casein. The reactions were stopped with sodium dodecyl sulfate (SDS) and products separated by capillary electrophoresis in micellar electrokinetic capillary chromatography (MEKC) mode using laser-induced fluorescence (LIF) detection. Comparison of the electropherograms showed no difference in the peptide profile for either enzyme. However, it was found that beta-casein was hydrolyzed more extensively than alphas-casein, by both enzymes. Capillary electrophoresis was found to be a very sensitive technique for detection of calpain activity. Using beta-casein as substrate, the CE approach was able to detect 2-3 ng of calpain activity. The results also suggest that capillary electrophoresis is a useful tool for proteolytic investigations of protein structure.  相似文献   

5.
High-throughput rheology in a microfluidic device   总被引:2,自引:0,他引:2  
Schultz KM  Furst EM 《Lab on a chip》2011,11(22):3802-3809
High-throughput rheological measurements in a microfluidic device are demonstrated. A series of microrheology samples are generated as droplets in an immiscible spacer fluid using a microfluidic T-junction. The compositions of the sample droplets are continuously varied over a wide range. Rheology measurements are made in each droplet using multiple particle tracking microrheology. We review critical design and operating parameters, including the droplet size, flow rates and rapid fabrication methods. Validation experiments are performed by measuring the solution viscosity of glycerine and the biopolymer heparin as a function of concentration. Overall, the combination of microrheology with microfluidics maximizes the number of rheological measurements while simultaneously minimizing the sample preparation time and amount of material, and should be particularly suited to the characterization of scarce or expensive materials.  相似文献   

6.
Stop-flow lithography in a microfluidic device   总被引:1,自引:0,他引:1  
Polymeric particles in custom designed geometries and with tunable chemical anisotropy are expected to enable a variety of new technologies in diverse areas such as photonics, diagnostics and functional materials. We present a simple, high throughput and high resolution microfluidic method to synthesize such polymeric particles. Building off earlier work that we have done on continuous flow lithography (CFL) (D. Dendukuri, D. C. Pregibon, J. Collins, T. A. Hatton, P. S. Doyle, Nat. Mater., 2006, 5, 365-369; ref. 1), we have devised and implemented a new setup that uses compressed air driven flows in preference to syringe pumps to synthesize particles using a technique that we call stop-flow lithography (SFL). A flowing stream of oligomer is stopped before polymerizing an array of particles into it, providing for much improved resolution over particles synthesized in flow. The formed particles are then flushed out at high flow rates before the cycle of stop-polymerize-flow is repeated. The high flow rates enable orders-of-magnitude improvements in particle throughput over CFL. However, the deformation of the PDMS elastomer due to the imposed pressure restricts how quickly the flow can be stopped before each polymerization event. We have developed a simple model that captures the dependence of the time required to stop the flow on geometric parameters such as the height, length and width of the microchannel, as well as on the externally imposed pressure. Further, we show that SFL proves to be superior to CFL even for the synthesis of chemically anisotropic particles with sharp interfaces between distinct sections.  相似文献   

7.
Magnetically labelled cells are finding a wealth of applications for in vitro analysis as well as in vivo treatments. Sorting of cells into subpopulations based on their magnetite loading is an important step in such procedures. Here, we study the sorting of monocytes and macrophages which internalise nanoparticles to different extents based on their endocytotic capacity. Macrophages featured a high endocytotic activity and were found to internalise between 4 and 60 pg of iron per cell. They were successfully sorted into five subpopulations of narrow iron loading distributions via on-chip free-flow magnetophoresis, thus demonstrating the potential of sorting of relatively similarly loaded cells. Monocytes featured a low endocytotic capacity and took on 1 to 4 pg of iron per cell. Mixtures of monocytes and macrophages were successfully sorted within the free-flow magnetophoresis chip and good purity (>88%), efficacy (>60%) and throughput (from 10 to 100 cells s(-1)) could be achieved. The introduced method constitutes a viable tool for studies of endocytotic capacity and sorting/selection of cells based on this functionality.  相似文献   

8.
Water disinfection byproducts (DBPs) are a class of chemicals that are produced when chemical disinfectants react with organic materials in untreated water. Cytotoxicity and genotoxicity of DBPs have been systematically evaluated to compile a comparative, quantitative database of in vitro mammalian cell toxicity of DBPs. However, one of the most challenging limitations for current DBP cytotoxicity assessment assays is sample availability. Although our current cytotoxicity assay using a 96-well microplate has been designed to reduce sample consumption, further minimization of the size of the test system would allow us to explore various possibilities for point-of-care applications. We have developed a microfluidic device with micro-pillars that shows high uniformity in distribution of cells across all chambers with low cell count. We compare the performance between the 96-well microplate and the microfluidic device by running 72-hour standalone-on-chip cell culture and cytotoxicity analysis experiments, using dimethyl sulfoxide (DMSO) and ethanol as model toxic agents, and bromoacetic acid (BAA) as a representative DBP. The results show close agreement between the two systems. The measured LC(50) values for the 96-well microplate and the microfluidic device are 1.54% v/v and 1.27% v/v for DMSO, 1.44% v/v and 2.92% v/v for ethanol, and 17.6 μM and 8.20 μM for BAA, respectively. The micro-pillar microfluidic device offers a great reduction in sample consumption while maintaining the accuracy of the cytotoxicity analyses of water disinfection byproducts.  相似文献   

9.
Shiddiky MJ  Won MS  Shim YB 《Electrophoresis》2006,27(22):4545-4554
A CE microsystem coupled with a microchip and a copper-(3-mercaptopropyl) trimethoxysilane (Cu-MPS) complex-modified carbon paste electrode (CPE) was developed for the simultaneous analysis of nitrite and nitrate. The method is based on the electrocatalytic reduction of both analytes with the modified electrode. The Cu-MPS complex was characterized by voltammetric, XPS, and FT-IR analyses. Experimental parameters affecting the sensitivity of the modified electrode were assessed and optimized. The best separation was achieved in a 60 mm separation channel filled with a 20 mM acetate buffer of pH 5.0 containing 3.0 mM CTAB at separation field strength of -250 V/cm within 90 s. The detection potential for the simultaneous analysis of nitrite and nitrate was found to be -225 mV versus Ag/AgCl. A reproducible response (RSD of 3.2% (nitrite) and 2.8% (nitrate), n = 8) for repetitive sample injections reflected the negligible electrode fouling at the modified CPE. The interference effect was examined for other inorganic ions and biological compounds. A wide hydrodynamic range between 0.25 and 120 microM was observed for analyzing nitrite and nitrate with the sensitivities of 0.069 +/- 0.003 and 0.065 +/- 0.002 nA/microM, and the detection limits, based on S/N = 3, were found to be 0.09 +/- 0.007 and 0.08 +/- 0.009 microM, respectively. The applicability of the method to water and urine samples analyses was demonstrated.  相似文献   

10.
DNA adducts are regarded as individual internal dosimeters for the exposure to chemical carcinogens. To date, the most sensitive method for DNA adduct analysis is the radioactive 32P-postlabeling method, which allows the detection of one adduct in 10(10) unmodified nucleotides in microg amounts of DNA. However, this technique suffers from disadvantages such as working with radioactive phosphorus and time-consuming chromatographic separation procedures. In addition, the simultaneous detection of adducts from different classes of carcinogens in a DNA sample is difficult. In order to overcome these drawbacks, we are developing a new detection method, comprising fluorescence labeling of DNA adducts, capillary electrophoretic (CE) separation, and on-line detection by monitoring laser-induced fluorescence (LIF). So far, we have evaluated the separation power and the detection limit of CE with fluorescently labeled standard compounds such as unmodified nucleotides or alkylated thymidines. For this purpose, we developed a universal method for labeling 5'-OH-mononucleosid-3'-dicyanoethyl-phosphates with fluorescent dyes based on the phosphoramidite technology for DNA synthesis. The separation of N3-methylated, N3-, O2- and O4-butylated thymidines from the unmodified nucleotide within a few minutes recommends CE-LIF as a powerful method for DNA adduct analysis.  相似文献   

11.
Caenorhabditis elegans, one of the widely studied model organisms, sense external chemical cues and perform relative chemotaxis behaviors through its simple chemosensory neuronal system. To study the mechanism underlying chemosensory behavior, a rapid and reliable method for quantitatively analyzing the worms' behaviors is essential. In this work, we demonstrated a microfluidic approach for investigating chemotaxis responses of worms to chemical gradients. The flow-based microfluidic chip was consisted of circular tree-like microchannels, which was able to generate eight flow streams containing stepwise chemical concentrations without the difference in flow velocity. Worms' upstream swimming into microchannels with various concentrations was monitored for quantitative analysis of the chemotaxis behavior. By using this microfluidic chip, the attractive and repellent responses of C. elegans to NaCl were successfully quantified within several minutes. The results demonstrated the wild type-like repellent responses and severely impaired attractive responses in grk-2 mutant animals with defects in calcium influx. In addition, the chemotaxis analysis of the third stage larvae revealed that its gustatory response was different from that in the adult stage. Thus, our microfluidic method provided a useful platform for studying the chemosensory behaviors of C. elegans and screening of chemosensation-related chemical drugs.  相似文献   

12.
13.
Lin F  Butcher EC 《Lab on a chip》2006,6(11):1462-1469
This paper describes the use of a simple microfluidic device for studying T cell chemotaxis. The microfluidic device is fabricated in poly(dimethylsiloxane) (PDMS) using soft-lithography and consists of a "Y" type fluidic channel. Solutions are infused into the device by syringe pumps and generate a concentration gradient in the channel by diffusion. We show that the experimentally measured gradient profiles agree nicely with theoretical predictions and the gradient is stable in the observation region for cell migration. Using this device, we demonstrate robust chemotaxis of human T cells in response to single and competing gradients of chemokine CCL19 and CXCL12. Because of the simplicity of the device, it can flexibly control gradient generation in space and time, and would allow generation of multiple gradient conditions in a single chip for highly parallel chemotaxis experimentation. Visualization of T cell chemotaxis has previously been limited to studies in 3D matrices or under agarose assays, which do not allow precise control or variation in conditions. Acknowledging the importance of lymphocyte homing in the adaptive immune response, the ability to study T cell chemotaxis in microfluidic devices offers a new approach for investigating lymphocyte migration and chemotaxis in vitro.  相似文献   

14.
With the advent of next-generation sequencing (NGS) systems and the associated high throughput they afford, the input to these machines requires manageable lengths of fragments (~1000 bp) produced from chromosomal DNAs. Therefore, it is critical to develop devices that can shear DNA in a controlled fashion. We report a polymer-based microfluidic device that establishes an efficient and inexpensive platform with performance comparable to a commercially available bench-top system.  相似文献   

15.
The release of reactive oxygen species (ROS) or reactive nitrogen species (RNS), i.e., the initial phase of oxidative stress, by macrophage cells has been studied by electrochemistry within a microfluidic device. Macrophages were first cultured into a detection chamber containing the three electrodes system and were subsequently stimulated by the microinjection of a calcium ionophore (A23187). Their production of ROS and RNS was then measured by amperometry at the surface of a platinized microelectrode. The fabricated microfluidic device provides an accurate measurement of oxidative release kinetics with an excellent reproducibility. We believe that such a method is simple and versatile for a number of advanced applications based on the detection of biological processes of secretion by a few or even a single living cell.  相似文献   

16.
Wei H  Chueh BH  Wu H  Hall EW  Li CW  Schirhagl R  Lin JM  Zare RN 《Lab on a chip》2011,11(2):238-245
Porous membranes have been fabricated based on the development of the perforated membrane mold [Y. Luo and R. N. Zare, Lab Chip, 2008, 8, 1688-1694] to create a single filter that contains multiple pore sizes ranging from 6.4 to 16.6 μm inside a monolithic three-dimensional poly(dimethylsiloxane) microfluidic structure. By overlapping two filters we are able to achieve smaller pore size openings (2.5 to 3.3 μm). This filter operates without any detectable irreversible clogging, which is achieved using a cross-flow placed in front of each filtration section. The utility of a particle-sorting device that contains this filter is demonstrated by separating polystyrene beads of different diameters with an efficiency greater than 99.9%. Additionally, we demonstrate the effectiveness of this particle-sorting device by separating whole blood samples into white blood cells and red blood cells with platelets.  相似文献   

17.
Kim YC  Park SJ  Park JK 《The Analyst》2008,133(10):1432-1439
This paper presents a new biomechanical analysis method for discrimination between cancerous and normal cells through compression by poly(dimethylsiloxane) (PDMS) membrane deflection in a microfluidic device. When a cell is compressed, cellular membrane will expand and then small bulges will appear on the peripheral cell membrane beyond the allowable strain. It is well known that the amount of F-actin in cancer cells is less than that of normal cells and bulges occur at the sites where cytoskeleton becomes detached from the membrane bilayer. Accordingly, we have demonstrated the difference of the bulge generation between breast cancer cells (MCF7) and normal cells (MCF10A). After excessive deformation, the bulges generated in MCF7 cells were not evenly distributed on the cell periphery. Contrary to this, the bulges of MCF10A cells showed an even distribution. In addition, the morphologies of bulges of MCF7 and MCF10A cells looked swollen protrusion and tubular protrusion, respectively. Peripheral strains at the moment of the bulge generation were also 72% in MCF7 and 46% in MCF10A. The results show that the bulge generation can be correlated with the cytoskeleton quantity inside the cell, providing the first step of a new biomechanical approach.  相似文献   

18.
Endothelial cell polarization and chemotaxis in a microfluidic device   总被引:2,自引:0,他引:2  
Shamloo A  Ma N  Poo MM  Sohn LL  Heilshorn SC 《Lab on a chip》2008,8(8):1292-1299
The directed migration of endothelial cells is an early and critical step in angiogenesis, or new blood vessel formation. In this study, the polarization and chemotaxis of human umbilical vein endothelial cells (HUVEC) in response to quantified gradients of vascular endothelial growth factor (VEGF) were examined. To accomplish this, a microfluidic device was designed and fabricated to generate stable concentration gradients of biomolecules in a cell culture chamber while minimizing the fluid shear stress experienced by the cells. Finite element simulation of the device geometry produced excellent agreement with the observed VEGF concentration distribution, which was found to be stable across multiple hours. This device is expected to have wide applicability in the study of shear-sensitive cells such as HUVEC and non-adherent cell types as well as in the study of migration through three-dimensional matrices. HUVEC were observed to chemotax towards higher VEGF concentrations across the entire range of concentrations studied (18-32 ng mL(-1)) when the concentration gradient was 14 ng mL(-1) mm(-1). In contrast, shallow gradients (2 ng mL(-1) mm(-1)) across the same concentration range were unable to induce HUVEC chemotaxis. Furthermore, while all HUVEC exposed to elevated VEGF levels (both in steep and shallow gradients) displayed an increased number of filopodia, only chemotaxing HUVEC displayed an asymmetric distribution of filopodia, with enhanced numbers of protrusions present along the leading edge. These results suggest a two-part requirement to induce VEGF chemotaxis: the VEGF absolute concentration enhances the total number of filopodia extended while the VEGF gradient steepness induces filopodia localization, cell polarization, and subsequent directed migration.  相似文献   

19.
Hematocrit (HCT) tests are widely performed to screen blood donors and to diagnose medical conditions. Current HCT test methods include conventional microhematocrit, Coulter counter, CuSO4 specific gravity, and conductivity‐based point‐of‐care (POC) HCT devices, which can be either expensive, environmentally inadvisable, or complicated. In the present work, we introduce a new and simple microfluidic system for a POC HCT determination. HCT was determined by measuring current responses of blood under 100 V DC for 1 min in a microfluidic device containing a single microchannel with dimensions of 180 μm by 70 μm and 10 mm long. Current responses of red blood cell (RBC) suspensions in PBS or separately plasma at HCT concentrations of 10, 20, 25, 30, 35, 40, 45, 50, 55, 60, and 70 vol% were measured to show feasibility of the microfluidic system for HCT determination. Key parameters affecting current responses included electrolysis bubbles and irreversible RBC adsorption; parameters were optimized via addition of nonionic surfactant Triton X‐100 into sample solution and carbonizing electrode surfaces. The linear trend line of current responses over a range of RBC concentrations were obtained in both PBS and plasma. This work suggested that a simple microfluidic device could be a promising platform for a new POC HCT device.  相似文献   

20.
A disk-shaped microfluidic device (lab-on-a-Disk) was developed to allow the evaluation of mental stress. As a standard sample, secretory immunoglobulin A (sIgA), which is a candidate marker of mental stress, was measured by a heterogeneous enzyme immunoassay (EIA) on the lab-on-a-Disk. Centrifugal force provided a microfluidic control on the lab-on-a-Disk. We examined the relationship between the rotational speed, the channel profile, and the position of the microfluidic chambers from the center of rotation to manipulate sample solutions into each reaction reservoir through microchannels sequentially, i.e., retain in a reservoir or flow into a subsequent reservoir. A single glass bead with immobilized sIgA on its surface was injected into a reservoir for a competitive antigen-antibody reaction, and applied to a specific surface in a heterogeneous assay. It is expected that the lab-on-a-Disk would be suitable for miniaturization and automation of the processes in EIA compared with a conventional EIA using a titer plate.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号