首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The aim of the present investigation was to determine spin lock (SL) relaxation parameters for the normal brain tissues and thus, to provide basis for optimizing the imaging contrast at 0.1 T. 68 healthy volunteers were included. On-resonance spin lock relaxation time (T) and off-resonance spin lock relaxation parameters (Toff, Me/Mo), MT parameters (T1sat, Ms/Mo), and T1, T2 were determined for the cortical gray matter, and for the frontal and parietal white matters. The T for the frontal and parietal white matters ranged from 110 to 133 ms and from 122 to 155 ms with locking field strengths from 50 μT to 250 μT, respectively. Accordingly, the values for the gray matter ranged from 127 to 155 ms. With a locking field strength of 50 μT, Toff for the frontal and parietal white matters were from 114 to 217 ms and from 126 to 219 ms, and for the gray matter from 136 to 267 ms with the angle between the effective magnetic field (Beff) and the z-axis (θ) ranging from 60° to 15°, respectively. The T of the white and gray matters increased significantly with increasing locking field amplitude (p < 0.001). The Toff decreased significantly with increasing θ (p < 0.001). T and Toff with θ ≥ 30° were statistically significantly shorter in the frontal than in the parietal white matters (p < 0.05). The duration, amplitude and θ of the locking pulse provide additional parameters to optimize contrast in brain SL imaging.  相似文献   

2.
Magnetization transfer between bound and free protons was used as a source of contrast in high speed MR imaging using the FLASH technique. Contrast in FLASH MR images was found to depend upon the reduced magnetization and the spin lattice relaxation rate of free protons in the presence of bound proton radio-frequency saturation. MTC FLASH imaging was thus used to estimate the variation with saturation frequency of free proton spin-lattice relaxation during magnetization transfer.  相似文献   

3.
4.
The human calf muscle was examined by using the magnetization transfer MR imaging technique. The time-dependent saturation transfer (TDST) method was applied at low magnetic field 0.1 T in order to measure the mobile water relaxation time T1w, the magnetization transfer rate Rwm from water to solid macromolecules, and the magnetization transfer contrast (MTC) of the human tissue. The magnetization transfer contrast of 0.67 was attained. The transfer rate Rwm was 4.5 sec-1 (+/- 0.3 sec-1) for the anterior tibial muscle and 5.0 sec-1 (+/- 0.4 sec-1) for the gastrocnemius muscles. The values of Rwm are considerably larger than the values of corresponding relaxation rates measured at high fields. The relaxation rate measurements of human tissues in vivo was shown to be possible at 0.1 T even within the framework of normal routine MR imaging. Magnetization transfer MR imaging is a very promising and practical method in order to assess the relaxation processes in heterogeneous human tissues in vivo, and it can improve the tissue characterization possibilities of MR imaging techniques.  相似文献   

5.
Results of the preliminary study on the evaluation of the role of magnetization transfer imaging (MTI) of prostate in men who had raised prostate-specific antigen (PSA) (>4 ng/ml) or abnormal digital rectal examination (DRE) are reported. MT ratio (MTR) was calculated for 20 patients from the hyper- (normal) and hypo-intense regions (area suspicious of malignancy as seen on T2-weighted MRI) of the peripheral zone (PZ) and the central gland (CG) at 1.5 T. In addition, MTR was calculated for three healthy controls. Mean MTR was also calculated for the whole of the PZ (including hyper- and hypo-intense area) in all patients. Out of 20 patients, biopsy revealed malignancy in 12 patients. Mean MTR value (8.29+/-3.49) for the whole of the PZ of patients who were positive for malignancy on biopsy was statically higher than that observed for patients who were negative for malignancy (6.18+/-3.15). The mean MTR for the whole of the PZ of controls was 6.18+/-1.63 and is similar to that of patients who were negative for malignancy. Furthermore, for patients who showed hyper- (normal portion) and hypo-intense (region suspicious of malignancy) regions of the PZ, the MTR was statistically significantly different. These preliminary results reveal the potential role of MT imaging in the evaluation of prostate cancer.  相似文献   

6.
Purpose: To study whether application of magnetization transfer contrast (MTC) improves visibility and detection of multiple sclerosis (MS) lesions on long repetition time (TR) conventional spin-echo (CSE) or fast spin-echo (FSE) magnetic resonance (MR) imaging.Material and methods: In 20 patients and 5 controls, MR images were obtained using long repetition time CSE and FSE sequences with and without MTC. Signal-to-noise ratios of normal appearing white matter (NAWM) and selected lesions, and contrast-to-noise ratios between lesions and NAWM, were calculated. Lesions were counted and total lesion volume was measured in a blinded fashion for each sequence.Results: In controls, MT effect in white matter (16.3% vs. 12.2%) was higher for CSE than for FSE (p < 0.01). Application of MTC to either CSE or FSE resulted in a significantly lower decrease in signal intensity of NAWM in patients compared to white matter in controls (p < 0.01). Furthermore, in patients signal intensity of lesions was less decreased than signal intensity of NAWM (p < 0.01). Compared to sequences without MTC, contrast-to-noise ratios were significantly higher on both CSE (10.9%) and FSE (6.3%) when MTC was applied (p < 0.01). Despite better visibility, the number of lesions detected on either sequences did not increase when MTC was applied. For CSE with MTC, we found an almost equal number of lesions and for FSE with MTC, we found even less lesions (p < 0.01). Total lesion volume did not change significantly when MTC was applied.Conclusion: Although contrast between lesions and NAWM improved when magnetization transfer contrast was applied, this did not increase detection of MS lesions on either CSE or FSE MR imaging.  相似文献   

7.
The addition of a spin-lock preparatory sequence to a Carr-Purcell-Meiboom-Gill (CPMG) imaging sequence provides a method which allows an accurate and simple comparison of T1p and T2 contrast. Sagittal and axial brain images, produced with the application of a three pulse preparatory spin-lock sequence prior to a sixteen-echo CPMG imaging sequence, are compared with images acquired without the spin-lock sequence. The CPMG sequence uses non-selective refocusing pulses. Therefore, observed echo signals accurately reflect T2 relaxation. This allows a convenient method for assessing the degree to which T1p and T2 contrast differ. The spin-lock CPMG (SL-CPMG) images were acquired with a spin-locking field amplitude of 0.4 G and resemble heavily T2-weighted images at 0.15 T. Quantitative analyses of signal intensities from edema and normal brain tissue confirm the qualitative observations. This in vivo method should prove useful for determining when the additional RF power deposition associated with spin-locking techniques will provide an alternate form of tissue contrast than that available from additional echo collection.  相似文献   

8.
In an effort to demonstrate the potential of nuclear magnetic resonance imaging (NMR) in the management of pregnancy, 15 patients in the first trimester and one in the third trimester of pregnancy have been investigated in the Aberdeen University NMR imager. Simple measurements of biparietal diameter and crown-rump length were made from both the NMR images and the ultrasound images on the same day, with good correlation between the two. The NMR data was displayed as inversion recovery, calculated T1, proton density and S1–S2 images. The proton density and S1–S2 images were found to be the most useful for the demonstration of the fetus and for discriminating between placenta and uterus. The calculated T1 data provided accurate quantification of the proton-spin lattice relaxation times of the different tissues, indicating that this measurement may be of use in the study of fetal brain development and placental function. The inversion recovery images showed poor tissue discrimination and were found to be of limited value. The unique information available using NMR and the non-invasive nature of the technique indicated that it should provide a useful method for the investigation of both fetal development and placental function in addition to making basic measurements of fetal size.  相似文献   

9.
10.
Signal fluctuations in functional magnetic resonance imaging (fMRI) can result from a number of sources that may have a neuronal, physiologic or instrumental origin. To determine the relative contribution of these sources, we recorded physiological (respiration and cardiac) signals simultaneously with fMRI in human volunteers at rest with their eyes closed. State-of-the-art technology was used including high magnetic field (7 T), a multichannel detector array and high-resolution (3 mm3) echo-planar imaging. We investigated the relative contribution of thermal noise and other sources of variance to the observed fMRI signal fluctuations both in the visual cortex and in the whole brain gray matter. The following sources of variance were evaluated separately: low-frequency drifts due to scanner instability, effects correlated with respiratory and cardiac cycles, effects due to variability in the respiratory flow rate and cardiac rate, and other sources, tentatively attributed to spontaneous neuronal activity. We found that low-frequency drifts are the most significant source of fMRI signal fluctuations (3.0% signal change in the visual cortex, TE=32 ms), followed by spontaneous neuronal activity (2.9%), thermal noise (2.1%), effects due to variability in physiological rates (respiration 0.9%, heartbeat 0.9%), and correlated with physiological cycles (0.6%). We suggest the selection and use of four lagged physiological noise regressors as an effective model to explain the variance related to fluctuations in the rates of respiration volume change and cardiac pulsation. Our results also indicate that, compared to the whole brain gray matter, the visual cortex has higher sensitivity to changes in both the rate of respiration and the spontaneous resting-state activity. Under the conditions of this study, spontaneous neuronal activity is one of the major contributors to the measured fMRI signal fluctuations, increasing almost twofold relative to earlier experiments under similar conditions at 3 T.  相似文献   

11.
Sodium MRI has been shown to be highly specific for glycosaminoglycan (GAG) content in articular cartilage, the loss of which is an early sign of osteoarthritis (OA). Quantitative sodium MRI techniques are therefore under development in order to detect and assess early biochemical degradation of cartilage, but due to low sodium NMR sensitivity and its low concentration, sodium images need long acquisition times (15-25 min) even at high magnetic fields and are typically of low resolution. In this preliminary study, we show that compressed sensing can be applied to reduce the acquisition time by a factor of 2 at 7 T without losing sodium quantification accuracy. Alternatively, the nonlinear reconstruction technique can be used to denoise fully-sampled images. We expect to even further reduce this acquisition time by using parallel imaging techniques combined with SNR-improved 3D sequences at 3T and 7 T.  相似文献   

12.
The general Fourier scheme for parameter selective imaging is subdivided into three periods: A preparation period for application of magnetization filters, an evolution period for space encoding, and a detection period for acquisition of the spectroscopic dimension. Depending on sample requirements and available time, the first and the last period can be omitted. Preparation of the initial magnetization for space encoding by appropriate filters is a powerful and time-saving way to introduce parameter-selective image contrast. This is illustrated by filters of molecular dynamics, which are sensitive to segmental motion in different time windows for contrast enhancement in composite and aged elastomers. Further contrast amplification is achieved by computing the difference of images acquired with different filter settings.  相似文献   

13.
Biexponential T(2) relaxation of the localized water signal can be used for segmentation of spectroscopic volumes. To assess the specificity of the components an iterative relaxation measurement of the localized water signal (STEAM, 12 echo times, geometric spacing from 30 ms to 2000 ms) was combined with magnetization transfer (MT) saturation (40 single lobe pulses, 12 ms duration, 1440 degrees nominal flip angle, 1 kHz offset, repeated every 30 ms). Voxels including CSF were examined in parietal cortex and periventricular parietal white matter (10 each), as well as 13 voxels in central white matter and 16 T(1)-hypointense non-enhancing multiple sclerosis lesions without CSF inclusion. Biexponential models (excluding myelin water) were fitted to the relaxation data. In periventricular VOIs the component of long T(2) (1736 +/- 168 ms) that is attributed to CSF was not affected by MT. In cortical VOIs this component had markedly shorter T(2)'s (961 +/- 239 ms) and showed both attenuation and prolongation with MT, indicating contributions from tissue. MS lesions and central WM showed a second tissue component of intermediate T(2) (160-410 ms). In white matter similar MT attenuation indicated strong exchange between the two tissue components, prohibiting segmentation. In MS lesions, however, markedly less MT of the intermediate component was found, which is consistent with decreased cellularity and exchange in a region that is large compared to diffusion motion.  相似文献   

14.
Ultra-high-field clinical MRI scanners (e.g., 7 T and above) are becoming increasingly prevalent and can potentially enhance diagnostic ability through higher contrast, resolution and/or sensitivity. Diffusion-weighted MRI is a highly valued component in today's radiological exam and may benefit from the enhanced signal-to-noise ratio provided by high field with the appropriate imaging strategy. The most common diffusion pulse sequence readout (echo-planar imaging (EPI)) has been widely employed for in vivo human 7 T diffusion tensor imaging (DTI). In this article, we present results of brain DTI at 7 T with two diffusion-weighted imaging pulse sequence readouts: echo-planar imaging (EPI-DTI) and turbo spin echo (TSE-DTI). Results indicate that analogous coverage, quality and resolution typical of lower field (2 mm) can be obtained by properly processed EPI-DTI at 7 T, and, with some reduction in efficiency and sharpness, TSE-DTI at 7 T. Furthermore, 7 T TSE-DTI shows promise in obtaining higher-resolution results in targeted acquisitions of specific brain areas.  相似文献   

15.
Contrast changes observed in functional magnetic resonance imaging in the human spinal cord were investigated with both motor and sensory tasks over a range of echo times. Data were acquired using a single-shot fast spin-echo sequence at 1.5 Tesla. Data were analyzed with two different correlation thresholds and the effects of altering the order of repeated experiments was also investigated. Plots of the fractional signal change as a function of echo time yielded linear functions with slopes corresponding to relaxation rate changes of -0.30 sec(-1) with sensory stimulation and approximately -0.50 sec(-1) with a motor task. However, the fractional signal change extrapolated to an echo time of zero was significantly greater than zero in each case and was roughly 2.5%. This suggests that in addition to the BOLD effect there is a baseline signal change which occurs concomitant to neuronal activation in the spinal cord.  相似文献   

16.
The Projector Quantum Monte Carlo method is used to study the two-dimensional Hubbard model with generalized boundary conditions at half-filling. The convergence of the algorithm depends strongly on the initial trial state. Spin-density waves provide an excellent trial state for the case of weak and of strong correlations. This choice of a trial state with broken symmetry allows us to calculate directly the staggered (or sublattice) magnetization m 0 as a function of the on-site repulsion U. The use of general boundary conditions strongly reduces finite size effects in m 0.  相似文献   

17.
This paper describes the development and application of a new fast MRI technique based on the DEFT principle. The sequence named MAgnetization RecoverY for Signal Enhancement (MARYSE) is composed of two completely symmetric gradient echoes separated by a 180 degrees refocusing pulse. The RF pulse scheme, 90 degrees x-180 degrees y-90 degrees -x enables restoration of the transverse magnetization along the longitudinal axis, and consequently artificially increases R1 relaxation rate. In this sequence, the period between the excitation pulse and the restoring pulse (Tem: transverse magnetization evolution time) is very short (< 10 ms). This makes possible a significant increase in signal-to-noise ratio, even with a relatively short repetition time (20 ms). Simulations were performed for different values of Tem and TR at definite T1 and T2 and for different values of T1 and T2 at constant Tem and TR. Relevant signal enhancement for species with long relaxation time constants as compared to classical gradient echo and fast spin-echo imaging was expected. In vitro studies on a fat/water phantom confirmed this simulation. Application of MARYSE to mouse brain imaging permitted to visualize almost completely cerebrospinal fluid of the ventricles, a signal usually partially saturated in fast gradient echo imaging.  相似文献   

18.
We have implemented an MR technique that employs a rapid gradient echo sequence, preceded by magnetization preparation pulses to provide T1- and T2-weighted tissue contrast. With this technique, which can be identified as a member of a new family of pulse sequences, generically named Magnetization Prepared RApid Gradient Echo (MP-RAGE), very short repetition times are used, allowing acquisition times of less than one second and images virtually free of motion-induced artifacts during quiet respiration. Fifteen patients with known liver lesions (metastases, hemangiomas, and cysts) were examined using T1- and T2-weighted 2-dimensional MP-RAGE sequences, and the images were compared with conventional T1- and multi-echo T2-weighted spin-echo (SE) sequences. Signal difference-to-noise ratios (SD/Ns) of the lesions were calculated for all pulse sequences using corresponding axial images and were normalized for voxel volume. The mean normalized SD/Ns of the MP-RAGE sequences were generally comparable to those for the SE sequences. In addition, there were no noticeable respiratory artifacts on the MP-RAGE images whereas these were clearly present on the T2-weighted SE images and to a lesser degree on the T1-weighted SE images. It is concluded that the MP-RAGE technique could become an important method for evaluating the liver for focal disease.  相似文献   

19.
We describe the design and testing of a quadrature transmit, eight-channel receive array RF coil configuration for the acquisition of images of the entire human spinal column at 7 T. Imaging parameters were selected to enable data acquisition in a clinically relevant scan time. Large field-of-view (FOV) scanning enabled sagittal imaging of the spine in two or three-stations, depending upon the height of the volunteer, with a total scan time of between 10 and 15 min. A total of 10 volunteers have been scanned, with results presented for the three subjects spanning the range of heights and weights, namely one female (1.6 m, 50 kg), one average male (1.8 m, 70 kg), and one large male (1.9 m, 100 kg).  相似文献   

20.
One-dimensional phase encoding was incorporated in the stimulated echo single voxel localization sequence for in vivo proton spectroscopic studies. Phantom studies were performed to assess the effect of the number of phase encoding steps on the spectral contamination from the adjacent volumes. Both water suppressed and unsuppressed spectra were obtained in reasonable acquisition times from various regions in the human leg with a spatial resolution of around 1.1 cm3.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号