首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
孙春艳  纪颖鹤  秦昆明  高珣  赵龙山 《色谱》2019,37(12):1297-1304
建立了一种同时测定吉非替尼中4种基因毒性杂质3-氯-4-氟苯胺、3,4-二氟苯胺、3-氟-4-氯苯胺和3,4-二氯苯胺的高效液相色谱-串联质谱(HPLC-MS/MS)方法。用Inertsil ODS-3柱(100 mm×3.0 mm,3μm)为色谱柱,以0.1%(体积分数,下同)甲酸水溶液-0.1%甲酸乙腈溶液为流动相,在电喷雾正离子模式下进行测定。该方法在特异性、线性、精密度、准确性、稳定性和耐用性方面得到了验证。4种基因毒性杂质在0.6~96.0μg/L范围内与峰面积呈良好线性关系。检测限和定量限分别为0.2~2.0μg/L和0.6~6.0μg/L。所有杂质的回收率为91.0%~98.5%。检测后,在批号16052301和R16052501-1样品中仅检测到3-氯-4-氟苯胺,但低于杂质限度(6 mg/L)。该方法简便可靠,可用于吉非替尼中4种基因毒性杂质的测定,并为质量控制提供参考。  相似文献   

2.
A rapid, sensitive and specific method to quantify bromazepam in human plasma using diazepam as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid-liquid extraction using diethyl ether-hexane (80 : 20, v/v). The extracts were analyzed by high-performance liquid chromatography (HPLC) coupled to electrospray tandem mass spectrometry (MS/MS). Chromatography was performed isocratically on a Genesis C(18) analytical column (100 x 2.1 mm i.d., film thickness 4 microm). The method had a chromatographic run time of 5.0 min and a linear calibration curve over the range 5.0-150 ng ml(-1) (r(2) > 0.9952). The limit of quantification was 5 ng ml(-1). This HPLC/MS/MS procedure was used to assess the bioequivalence of two bromazepam 6 mg tablet formulations (bromazepam from Medley SA Indústria Farmacêutica as the test formulation and Lexotan from Produtos Roche Químico e Farmacêutico SA as the reference formulation). A single 6 mg dose of each formulation was administered to 24 healthy volunteers (12 males and 12 females). The study was conducted using an open, randomized, two-period crossover design with a 3 week washout interval. Since the 90% CI for C(max), AUC(last), AUC(0-240 h) (linear) and AUC((0- infinity )) ratios were all inside the 80-125% interval proposed by the US Food and Drug Administration, it was concluded that the bromazepam formulation from Medley is bioequivalent to the Lexotan formulation for both the rate and the extent of absorption.  相似文献   

3.
Atrasentan (A-147627) is an endothelin antagonist receptor being developed at Abbott Laboratories for the treatment of prostate cancer. A quick and sensitive method for the determination of atrasentan in human plasma has been developed and validated using high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry. A dual-column, single mass spectrometer system is used to provide a reliable and routine means to increase sample throughput. The analytical method involves liquid-liquid extraction and internal standard (A-166790). The plasma samples and internal standard are acidified with 0.3 M hydrochloric acid prior to being extracted into 1:1 (v/v) hexanes--methyl t-butyl ether. The organic extract was evaporated to dryness using heated nitrogen stream and reconstituted with mobile phase. Atrasentan and internal standard were separated with no interference in a Zorbax SB-C(18) analytical column with 2.1 x 50 mm, 5 microm, and a Zorbax C(8) guard column using a mobile phase consisting of 50:50 (v:v) acetonitrile--0.05 M ammonium acetate, pH 4.5, at a flow rate of 0.30 mL/min to provide 4 min chromatograms. For a 250 microL plasma sample volume, the limit of quantitation was approximately 0.3 ng/mL. The calibration was linear from 0.30 to 98.0 ng/mL (r(2) > 0.995). A significant advantage of the method is the ability to employ parallel HPLC separations with detection by a single MS/MS system to provide sensitivity and selectivity sufficient to achieve robust analytical results with a lower limit of quantitation of 0.30 ng/mL and high throughput.  相似文献   

4.
液相色谱-电喷雾串联质谱法测定生姜中的215种农药残留   总被引:4,自引:1,他引:4  
曹静  庞国芳  王明林  范春林 《色谱》2010,28(6):579-589
建立了生姜中215种农药多残留测定的液相色谱-电喷雾串联质谱(LC-ESI-MS/MS)方法。样品用1%醋酸-乙腈溶液均质提取,经Sep-Pak Vac固相萃取柱净化,乙腈-甲苯(3:1, v/v)洗脱,旋转蒸发浓缩至约0.5 mL后,于室温氮气吹干,用乙腈-水(3:2, v/v)溶解,以电喷雾电离串联质谱在正离子多反应监测(MRM)模式下进行测定。在定量限水平进行添加回收率实验,方法的回收率范围为68.1%~132.6%,其中回收率在70%~120%的占94.4%,相对标准偏差(RSD)范围为0.4%~25.0%。方法的检出限(S/N=3)和定量限(S/N=10)范围分别为0.01~70.45 μg/L和0.04~234.84 μg/L。该方法操作简便,灵敏度、准确度和精密度均符合农药多残留检测技术要求,适用于生姜中215种农药多残留的快速测定。  相似文献   

5.
A novel method for the analysis of endogenous lipids and related compounds was developed employing hydrophilic interaction liquid chromatography with electrospray ionization tandem mass spectrometry. A hydrophilic interaction liquid chromatography with carbamoyl stationary phase achieved clear separation of phosphatidylcholine, lysophosphatidylcholine, sphingomyelin, ceramide, and mono‐hexsosyl ceramide groups with good peak area repeatability (RSD% < 10) and linearity (R2 > 0.99). The established method was applied to human plasma assays and a total of 117 endogenous lipids were successfully detected and reproducibly identified. In addition, we investigated the simultaneous detection of small polar metabolites such as amino and organic acids co‐existing in the same biological samples processed in a single analytical run with lipids. Our results show that hydrophilic interaction liquid chromatography is a useful tool for human plasma lipidome analysis and offers more comprehensive metabolome coverage.  相似文献   

6.
An accurate and selective method for the simultaneous determination of triptolide, tripdiolide and tripterine in human urine using hydrocortisone as an internal standard (IS) by high-performance liquid chromatography coupled with atmospheric-pressure chemical ionization mass spectrometry in negative ion mode has been developed. After triptolide, tripdiolide and tripterine in human urine were extracted with ethyl acetate and cleaned by solid-phase extraction with C(18) cartridges, a satisfactory separation was achieved on an XDB C(18) short column (30 x 2.1 mm i.d., 3 microm) using the mobile phase of acetic acid-ammonium acetate (5 mmol/L, pH = 4.5)-acetonitrile-methanol in gradient elution. Detection was operated by APCI in selected ion monitoring mode. The target ions m/z 359, m/z 375, m/z 449 and m/z 419 were selected for the quantification of triptolide, tripdiolide, tripterine and IS, respectively. The linear range was 1.0-100.0 ng mL(-1), and the limits of quantification in human urine were found to be 0.1-0.5 ng mL(-1) for the three compounds. The precisions (CV%) and accuracies were 6.6-12.9 and 85.1-97.0%, respectively. The developed method could be applied to the determination of triptolide, tripdiolide and tripterine in human urine for diagnosis of the intoxication and for forensic purposes.  相似文献   

7.
Paraquat (PQ) and diquat (DQ) in human whole blood and urine were analyzed by high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) with positive ion electrospray ionization (ESI). The compounds were extracted with Sep-Pak C18 cartridges from whole blood and urine samples containing ethyl paraquat as an internal standard. The separation of PQ and DQ was carried out using ion-pair chromatography with heptafluorobutyric acid in 20 mM ammonium acetate and acetonitrile gradient elution for successful coupling with MS. Both compounds formed base peaks due to [M-H]+ ions by HPLC/ESI-MS and the product ions produced from each [M-H]+ ion by HPLC/MS/MS. Selective reaction monitoring (SRM) showed much higher sensitivity for both body fluids. Therefore, a detailed procedure for the detection of compounds by SRM with HPLC/MS/MS was established and carefully validated. The recoveries of PQ and DQ were 80.8-95.4% for whole blood and 84.2-96.7% for urine. The calibration curves for PQ and DQ showed excellent linearity in the range of 25-400 ng ml(-1) of whole blood and urine. The detection limits were 10 ng ml(-1) for PQ and 5 ng ml(-1) for DQ in both body fluids. The intra- and inter-day precision for both compounds in whole blood and urine samples were not greater than 13.0%. The data obtained from the determination of PQ and DQ in rat blood after oral administration of the compounds are also presented.  相似文献   

8.
Flavonoids are a class of secondary plant metabolites existing in great variety in nature. Due to this variety, identification can be difficult, especially as overlapping compounds in both chromatographic separations and mass spectrometric detection are common. Methods for distinguishing isobaric flavonoids using MS2 and MS3 have been developed. Chromatographic separation of various plant extracts was done with RP‐HPLC and detected with positive ESI‐MS operated in information‐dependent acquisition (IDA) mode. Two methods for the determination of flavonoid identity and substitution pattern, both featuring IDA criteria, were used together with the HPLC equipment. A third method where the collision energy was ramped utilized direct infusion. With the developed strategies, it is possible to differentiate between many isobaric flavonoids. Various classes of flavonoids were found in all of the plant extracts, in the red onion extract 45 components were detected and for 29 of them the aglycone was characterized, while the substituents were tentatively identified for 31 of them. For the strawberry extract, those numbers were 66, 30 and 60, and for the cherry extract 99, 56 and 71. The great variety of flavonoids, several of them isobaric, found in each of the extracts highlights the need for reliable methods for flavonoid characterization. Methods capable of differentiating between most of the isobars analyzed have been developed. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

9.
啤酒中单糖的衍生化HPLC-ESI-MS测定方法研究   总被引:4,自引:0,他引:4  
单糖类样品在溶液中非常稳定,难于离子化,不适合于进行ESI-MS检测。采用1-苯基-3-甲基-5-吡唑啉酮(PMP)将糖类物质衍生化,HPLC-ESI-MS在线联用,选择性离子扫描方式对几种啤酒样品中的5种单糖进行了分离检测。检出限可达到80pg。  相似文献   

10.
LC/MS法分析头孢替坦二钠原料中的杂质   总被引:2,自引:0,他引:2  
本文应用LC/MS技术对头孢替坦二钠原料中的4种杂质进行了快速鉴定.根据头孢菌素的降解反应机制设计加速实验,确定头孢替坦的2个主要杂质为其碱水解产物;以1%冰醋酸溶液-乙腈-甲醇为流动相,经C18柱分离,通过电喷雾串联质谱负离子检测,获得各杂质的相对分子质量信息和碎片信息,并辅助UV特征对杂质结构进行了鉴定.在所建立的LC/MS条件下,头孢替坦及其杂质得到有效的分离,4个杂质经分析分别为5-巯基-1-甲基-四氮唑、头孢替坦内酯、头孢替坦脱羧物和头孢替坦异构体.本研究表明,利用LC/MS技术可推测头孢菌素类抗生素中杂质的结构,且本方法快速、灵敏、专属性高.  相似文献   

11.
HIV protease inhibitors are important antiretroviral drugs which have substantially reduced the morbidity and mortality associated with HIV-1 infection. Recent data have shown relationships between plasma concentrations of the protease inhibitors and clinical response, which makes therapeutic drug monitoring valuable. We have developed and validated an assay, using liquid chromatography coupled with electrospray tandem mass spectrometry (LC/MS/MS), for the routine quantification of the six licensed protease inhibitors (amprenavir, indinavir, lopinavir, nelfinavir, ritonavir and saquinavir) and the pharmacologically active nelfinavir metabolite M8 in plasma. The sample pretreatment consisted of protein precipitation with a mixture of methanol and acetronitrile using only 100 microl of plasma. Chromatographic separation was performed on an Inertsil ODS3 column (50 x 2.0 mm i.d., particle size 5 microm), with a quick stepwise gradient using an acetate buffer (pH 5) and methanol, at a flow rate of 0.5 ml min(-1). The analytical run time was 5.5 min. The use of a 96-well plate autosampler allowed batch sizes up to 150 patient samples. The triple-quadrupole mass spectrometer was operated in the positive ion mode and multiple reaction monitoring was used for drug quantification. The method was validated over the concentration ranges 0.01-10 microg ml(-1) for indinavir and saquinavir, 0.1-10 microg ml(-1) for amprenavir, 0.05-10 microg ml(-1) for nelfinavir and ritonavir, 0.1-20 microg ml(-1) for lopinavir and 0.01-5 microg ml(-1) for M8. Saquinavir-d(5) and indinavir-d(6) were used as internal standards. The coefficients of variation were always <10% for both intra-day and inter-day precisions for each compound. Mean accuracies were also between the designated limits (+/-15%). The validated concentration ranges proved to be adequate in daily practice. This robust and fast LC/MS/MS assay is now successfully applied for routine therapeutic drug monitoring and pharmacokinetic studies in our hospital.  相似文献   

12.
In this work, we have developed a sensitive method for detection and quantification of eight N-nitrosamines, N-nitrosodimethylamine (NDMA), N-nitrosomorpholine (NMor), N-nitrosomethylethylamine (NMEA), N-nitrosopirrolidine (NPyr), N-nitrosodiethylamine (NDEA), N-nitrosopiperidine (NPip), N-nitroso-n-dipropylamine (NDPA) and N-nitrosodi-n-butylamine (NDBA) in drinking water. The method is based on liquid chromatography coupled to tandem mass spectrometry, using atmospheric pressure chemical ionization (APCI) in positive mode with a triple quadrupole analyzer (QqQ). The simultaneous acquisition of two MS/MS transitions in selected reaction monitoring mode (SRM) for each compound, together with the evaluation of their relative intensity, allowed the simultaneous quantification and reliable identification in water at ppt levels. Empirical formula of the product ions selected was confirmed by UHPLC-(Q)TOF MS accurate mass measurements from reference standards.Prior to LC–MS/MS QqQ analysis, a preconcentration step by off-line SPE using coconut charcoal EPA 521 cartridges (by passing 500 mL of water sample) was necessary to improve the sensitivity and to meet regulation requirements. For accurate quantification, two isotope labelled nitrosamines (NDMA-d6 and NDPA-d14) were added as surrogate internal standards to the samples.The optimized method was validated at two concentration levels (10 and 100 ng L−1) in drinking water samples, obtaining satisfactory recoveries (between 90 and 120%) and precision (RSD < 20%). Limits of detection were found to be in the range of 1–8 ng L−1. The described methodology has been applied to different types of water samples: chlorinated from drinking water and wastewater treatment plants (DWTP and WWTP, respectively), wastewaters subjected to ozonation and tap waters.  相似文献   

13.
A novel qualitative and quantitative method using high-performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS) was developed for simultaneous determination of the nine major active constituents in Pulsatilla cernua (Thunb.) Bercht. et Opiz., namely anemoside A3 (1), anemoside B4 (2), 23-hydroxybetulinic acid (3), cirenshenoside S (4), pulsatilloside B (5), pulsatilloside C (6), oleanolic acid (7), ajugasterone C (8) and β-ecdysterone (9), respectively. A Sapphire C18 column (250 mm × 4.6 mm, 5 μm) and gradient elution were used during the analysis. The identification and quantification of the analytes were achieved on a hybrid quadrupole linear ion trap mass spectrometer. Multiple-reaction monitoring (MRM) scanning was employed for quantification with switching electrospray ion source polarity between positive and negative modes in a single run. All calibration curves showed good linearity (r(2) > 0.9948) within the test ranges. The intra and interday variations for nine analytes were less than 3.95 and 3.78%, respectively. The developed method was successfully applied to determine the investigated compounds in 15 batches of natural and cultured samples of P. cernua. The results indicated that the method was simple, rapid, specific and reliable, which is helpful to comprehensive evaluation of quality of P. cernua.  相似文献   

14.
Pigments are among the most important components of historical paintings and textiles and their nature provides the unique character of color. They can be divided into two main groups: inorganic and organic, extracted from plants or animals. Their identification is a necessary stage in the conservation of art objects. Reversed-phase liquid chromatography with electrospray ionization mass spectrometry (ESI-MS) and UV/visible spectrophotometric methods were elaborated for the identification of indigoid (indigo, indirubin, isoindigo, isoindirubin) color components of natural dyestuffs and their natural or synthetic precursors (indican, isatin, indoxyl, 2-indolinone). ES-MS offers detection limits in the range 0.03-5.00 microg ml(-1) for the color compounds examined. The method developed made it possible to identify indigo and its isomers in genuine Indian indigo, indigo from woad and Tyrian Purple. It was applied to the identification of natural dyes on fiber from a 19th century Japanese tapestry, 'Cranes in the landscape'. A procedure based on freezing and grinding of a sample before the extraction of dyes from the textile was developed. The components of the extract obtained were identified after acidic hydrolysis as indigotin and methylene blue.  相似文献   

15.
N-(Dicyclohexyl)acetylpiperidine-4-benzylidene-4-carboxylic acid (1) is an excellent in vitro inhibitor of 5 alpha-reductase (5 alpha R). Compound 1 showed, however, much lower inhibition activity of 5 alpha R in vivo than in vitro, which might be caused by poor membrane permeability. The methyl ester of 1 (1a) was therefore tested as a model prodrug to see if it has better permeability properties than the corresponding acid 1. It was also monitored that this methyl ester was cleaved into the active compound 1 within the DU145 cells. Quantitative matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) and high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) methods were established with reliable linearity factors (0.996 for MALDI-TOFMS and 0.998 for HPLC/MS/MS) and reproducibility (relative standard deviation = 6.5% for MALDI-TOFMS and 2.8% for HPLC/MS/MS). The samples for MS analysis were effectively prepared from the cell homogenates using solid-phase extraction, with a high recovery of 90% on average. The intracellular amount of 1a (1.7 nmol) was much higher than that of 1 (0.032 nmol) in DU145 cells after 6 h of incubation. After incubation with the ester (1a), the cleaved acid (1) was detected within the cells. The concentration of acid 1 (0.045 nmol) in this experiment was higher than the acid content (0.032 nmol) after direct incubation with 1. Surprisingly, high amounts of the cleaved compound 1 were found outside the cells after 6 h of incubation with 1a.  相似文献   

16.
Aspartame is a widely used sweetener,the long-term safety of which has been controversial ever since it was accepted for human consumption.It is unstable and can produce some harmful degradation products under certain storage conditions.A high-performance liquid chromatography/tandem mass spectrometry method was developed for the simultaneous analysis of aspartame and its four degradation products,including aspartic acid,phenylalanine,aspartyl-phenylalanine and 5-benzyl-3,6-dioxo-2-piperazieacetic acid in water and in diet soft drinks.Aspartame and its four degradation products were quantified by a matrix matched external standard calibration curve with excellent correlation coefficients.The limits of detection were 0.16–5.8 mg/L,which exhibited higher sensitivity than common methods.This method was rapid,sensitive,specific and capable of eliminating matrix interferences.It was also applied to the study of the degradation of aspartame at various pH and temperatures.The results indicated that aspartame was partly degraded under strong acidic or basic conditions and the extent of degradation increased with increasing temperature.  相似文献   

17.
A simple and sensitive liquid chromatography-tandem mass spectrometry method was developed and validated for determining domperidone in human plasma. The analyte and internal standard (IS; mosapride) were isolated from plasma samples by protein precipitation with methanol (containing 0.1% formic acid). The chromatographic separation was performed on an Xterra MS C(18) Column (2.1 x 150 mm, 5.0 microm) with a gradient programme mobile phase consisting of 0.1% formic acid and acetonitrile at a flow rate of 0.30 mL/min. The total run time was 4.0 min. The analyses were carried out by multiple reaction monitoring using the parent-to-daughter combinations m/z 426 --> 175 and m/z 422 --> 198 (IS). The areas of peaks from the analyte and IS were used for quantification of domperidone. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicated that the lower limit of quantification was 0.2 ng/mL, and the assay exhibited a linear range of 0.2-60.0 ng/mL and gave a correlation coefficient (r(2)) of 0.999 or better. Quality control samples (0.4, 0.8, 15 and 50 ng/mL) in six replicates from three different analytical runs demonstrated an intra-assay precision (RSD) 4.43-6.26%, an inter-assay precision 5.25-7.45% and an overall accuracy (relative error) of <6.92%. The method can be applied to pharmacokinetic and bioequivalence studies of domperidone.  相似文献   

18.
Summary Reversed-phase liquid chromatography with fluorescence detection (RPLC-FD) and with electrospray ionization (ESI) tandem mass spectrometric detection (RPLC-ESI-MS-MS), both coupled with automated solid-phase sample extraction, have been used for trace enrichment and analysis of octylphenol and nonylphenol (NP) in municipal wastewater. Quality data calculated for the methods were detection limits (LOD), quantitation limits, linearity, precision, and accuracy. For LC-ESI-MS-MS theLOD were below 0.08 μg L−1. Unequivocal detection of NP in wastewater samples was achieved by use of LC-ESI-MS and LC-ESI-MS-MS. In particular, application of the LC methods to wastewater samples revealed that the selectivity of LC-MS-MS was more than that of LC-FD for qualitative and quantitative analysis of complex matrices.  相似文献   

19.
20.
A rapid, sensitive and specific method to quantify nevirapine in human plasma using dibenzepine as the internal standard (IS) was developed and validated. The method employed a liquid-liquid extraction. The analyte and the IS were chromatographed on a C(18) analytical column, (150 x 4.6 mm i.d. 4 microm) and analyzed by tandem mass spectrometry in the multiple reaction monitoring mode. The method had a chromatographic run time of 5.0 min and a linear calibration curve over the range 10-5000 ng ml(-1) (r(2) > 0.9970). The between-run precision, based on the relative standard deviation for replicate quality controls was 1.3% (30 ng ml(-1)), 2.8% (300 ng ml(-1)) and 3.6% (3000 ng ml(-1)). The between-run accuracy was 4.0, 7.0 and 6.2% for the above-mentioned concentrations, respectively. This method was employed in a bioequivalence study of two nevirapine tablet formulations (Nevirapina from Far-Manguinhos, Brazil, as a test formulation, and Viramune from Boehringer Ingelheim do Brasil Química e Farmacêutica, as a reference formulation) in 25 healthy volunteers of both sexes who received a single 200 mg dose of each formulation. The study was conducted using an open, randomized, two-period crossover design with a 3 week washout interval. The 90% confidence interval (CI) of the individual ratio geometric mean for Nevirapina/Viramune was 96.4-104.5% for AUC((0-last)), 91.4-105.1% for AUC((0-infinity)) and 95.3-111.6% for C(max) (AUC = area under the curve; C(max) = peak plasma concentration). Since both 90% CI for AUC((0-last)) and AUC((0-infinity)) and C(max) were included in the 80-125% interval proposed by the US Food and Drug Administration, Nevirapina was considered bioequivalent to Viramune according to both the rate and extent of absorption.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号