首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An electrochemical method for the simultaneous determination of benzene, toluene and xylenes (BTX) in water was developed using square‐wave voltammetry (SWV). The determination of BTX was carried out using a cathodically pre‐treated boron‐doped diamond electrode (BDD) using 0.1 mol L?1 H2SO4 as supporting electrolyte. In the SWV measurements using the BDD, the oxidation peak potentials of the total xylenes‐toluene and toluene‐benzene couples, present in ternary mixtures, display separations of about 100 and 200 mV, respectively. The attained detection limits for the simultaneous determination of benzene, toluene and total xylenes were 3.0×10?7, 8.0×10?7 and 9.1×10?7 mol L?1, respectively. The recovery values taken in ternary mixtures of benzene, toluene and total xylenes in aqueous solutions are 98.9 %, 99.2 % and 99.4 %, respectively.  相似文献   

2.
The electrochemical characteristics of multi-component phenolic pollutants, such as phenol (Ph), hydroquinone (HQ) and 4-nitrophenol (4-NP), were investigated on boron-doped diamond (BDD) film electrode by differential pulse voltammetry (DPV) technique. A simple and feasible platform was accordingly established for the direct and simultaneous determination of these three phenolic pollutants. Results showed that, Ph, HQ and 4-NP gave obvious oxidation peaks on BDD electrode at the potential of 1.24, 0.76 and 1.52 V, respectively. Each of them displayed good linear relationship between their oxidation peak currents and their corresponding concentrations in a rather wide range coexisting with one or two of the other phenolic pollutants. The detection limits of Ph, HQ and 4-NP were estimated to be as low as 1.82×10^-6, 1.67×10^-6 and 1.44×10^-6 mol·L^-1, respectively. Therefore, a promising direct and simultaneous electrochemical determination method of multi-component phenolic pollutants in wastewater samples was constructed successfully on BDD electrode with advantages being rapid, simple, convenient, sensitive, in situ and inexpensive.  相似文献   

3.
《Analytical letters》2012,45(12):1958-1975
The electrooxidative behavior and determination of lercanidipine (LRC) were investigated in aqueous acetonitrile medium at a boron-doped diamond electrode using voltammetric techniques. The LRC in selected supporting electrolyte presents a well-defined anodic response at 0.944 V, studied by the proposed method. The linear response was obtained in the ranges of 4 × 10?6 to 2 × 10?4 mmol L?1 range in 0.5 mmol L?1 sulfuric acid supporting electrolyte and 1 × 10?5 to 8 × 10?5 mmol L?1 range in spiked serum sample for square wave voltammetric technique. No electroactive interferences from the excipients and endogenous substances were found in the pharmaceutical dosage form and in the biological sample, respectively.  相似文献   

4.
《Analytical letters》2012,45(5-6):449-459
Based on the study of voltammetric behavior of carcinogenic 1-nitropyrene (1-NP), 1-aminopyrene (1-AP), and 1-hydroxypyrene (1-HP), optimum conditions have been found for the determination of these analytes by differential pulse voltammetry (DPV) at a boron-doped diamond film electrode. The optimum medium was methanol-Britton–Robinson buffer (BR buffer) pH 3.0 (70:30) for 1-NP and 1-AP, and methanol-BR buffer pH 5.0 (70:30) for 1-HP. Concentration dependences of the DPV response were measured in the range 1 · 10?6–1 · 10?4 mol dm?3 (R = ?0.9998) with the limit of detection (LOD) 3 · 10?7 mol dm?3 for 1-NP, 1 · 10?7–1 · 10?5 mol dm?3 (R = 0.9971) with LOD 6 · 10?8 mol dm?3 for 1-AP, and 1 · 10?7–1 · 10?5 mol dm?3 (R = 0.9934) with LOD 1 · 10?7 mol dm?3 for 1-HP. Simultaneous determination of 1-NP and 1-AP in a mixture was tested in the methanol-BR buffer pH 3.0 (70:30) medium as well. The content of 1-AP in the concentration range from 1 · 10?6 to 1 · 10?4 mol dm?3 had no effect on the sensitivity of the determination of 1-NP, and vice versa. Due to the close peak potentials of 1-AP and 1-HP, the direct determination of their mixture using voltammetric methods is impossible.  相似文献   

5.
N‐acetylcysteine (NAC) and gentamicin sulfate (GS) are biologically and pharmaceutically relevant thiol‐containing compounds. NAC is well known for its antioxidant properties, whereas GS is an aminoglycoside that is used as a broadband antibiotic. Both pharmaceuticals play a significant role in the treatment of bacterial infections by suppressing the formation of biofilms. According to the European Pharmacopeia protocol, GS is analyzed by high performance liquid chromatography (HPLC) using gold electrodes for electrochemical detection. Here, we report the electrochemical detection of these compounds at NH2‐terminated boron‐doped diamond electrodes, which show significantly reduced electrode passivation, an issue commonly known for gold electrodes. Cyclic voltammetry experiments performed for a period of 70 minutes showed that the peak current decreased only by 1.6 %/7.4 % for the two peak currents recorded for GS, and 6.6 % for the oxidation peak of NAC, whereas at gold electrodes a decrease in peak current of 14.2 % was observed for GS, and of 64 %/30 % for the two peak currents of NAC. For their quantitative determination, differential pulse voltammetry was performed in a concentration range of 2–49 µg/mL of NAC with a limit of detection (LOD) of 1.527 µg/mL, and a limit of quantification (LOQ) of 3.624 µg/mL, respectively. The quantification of GS in a concentration range of 0.2–50 µg/mL resulted in a LOD of 1.714 µg/mL, and a LOQ of 6.420 µg/mL, respectively.  相似文献   

6.
The present work describes the first electrochemical investigation and a simple, rapid and modification‐free electroanalytical methodology for quantification of hordenine (a potent phenylethylamine alkaloid) using a boron‐doped diamond electrode. At optimized square‐wave voltammetric parameters, the observed oxidation peak current in 0.1 M HClO4 at +1.33 V (vs. Ag/AgCl) increased linearly from 5.0 to 100 μg mL?1 (3.0×10?5–6.1×10?4 M), with detection limit of 1.3 μg mL?1 (7.8×10?6 M). The applicability of the developed method was tested with the determination of hordenine in the commercial dietary supplement formulations.  相似文献   

7.
The electrochemical properties of methylisothiazolinone (MIT), the most widely used preservative, were investigated by cyclic (CV) and differential pulse voltammetry (DPV) to develop a new method for its determination. To our knowledge, this is the first demonstration of a voltammetric procedure for the determination of MIT on a boron-doped diamond electrode (BDDE) in a citrate–phosphate buffer (C-PB) environment. The anodic oxidation process of methylisothiazolinone, which is the basis of this method, proved to be diffusion-controlled and proceeded with an irreversible two-electron exchange. The radical cations, as unstable primary products, were converted in subsequent chemical reactions to sulfoxides and sulfones, and finally to more stable final products. Performed determinations were based on the DPV technique. A linear calibration curve was obtained in the concentration range from 0.7 to 18.7 mg L−1, with a correlation coefficient of 0.9999. The proposed procedure was accurate and precise, allowing the detection of MIT at a concentration level of 0.24 mg L−1. It successfully demonstrated its suitability for the determination of methylisothiazolinone in household products without the need for any separation steps. The proposed method can serve as an alternative to the prevailing chromatographic determinations of MIT in real samples.  相似文献   

8.
《Electroanalysis》2017,29(7):1691-1699
The simultaneous voltammetric determination of melatonin (MT) and pyridoxine (PY) has been carried out at a cathodically pretreated boron‐doped diamond electrode. By using cyclic voltammetry, a separation of the oxidation peak potentials of both compounds present in mixture was about 0.47 V in Britton‐Robinson buffer, pH 2. The results obtained by square‐wave voltammetry allowed a method to be developed for determination of MT and PY simultaneously in the ranges 1–100 μg mL−1 (4.3×10−6–4.3×10−4 mol L−1) and 10–175 μg mL−1 (4.9×10−5–8.5×10−4 mol L−1), with detection limits of 0.14 μg mL−1 (6.0×10−7 mol L−1) and 1.35 μg mL−1 (6.6×10−6 mol L−1), respectively. The proposed method was successfully to the dietary supplements samples containing these compounds for health‐caring purposes.  相似文献   

9.
Voltammetric methods for estrone determination were developed using a cathodically pretreated BDD electrode with DPV or SWV. Analytical curves were obtained for estrone concentrations from 0.20 or 0.10 to 2.0 µmol L?1, for DPV or SWV, with detection limits of 0.20 and 0.10 µmol L?1, respectively. The SWV method was successfully applied in estrone recovery studies in different water matrices. Additionally, these recovery results were reasonably similar to those attained using HPLC/UV‐vis. Comparatively to other electroanalytical methods based on different carbon electrodes, the here‐reported novel methods yield very good results, being adequate for estrone determination in environmental samples.  相似文献   

10.
An effective electrochemical sensor was constructed using an unmodified boron-doped diamond electrode for determination of genistein by square-wave voltammetry. Cyclic voltammetric investigations of genistein with HClO4 solution indicated that irreversible behavior, adsorption-controlled and well-defined two oxidation peaks at about +0.92 (PA1) & +1.27 V (PA2). pH, as well as supporting electrolytes, are important in genistein oxidations. Quantification analyses of genistein were conducted using its two oxidation peaks. Using optimized experiments as well as instrumental conditions, the current response with genistein was proportionately linear in the concentrations range of 0.1 to 50.0 μg mL−1 (3.7×10−7−1.9×10−4 mol L−1), by the detection limit of 0.023 μg mL−1 (8.5×10−8 mol L−1) for PA1 and 0.028 μg mL−1 (1.1×10−7 mol L−1) for PA2 in 0.1 mol L−1 HClO4 solution (in the open circuit condition at 30 s accumulation time). Ultimately, the developed method was effectively applied to detect genistein in model human urine samples by using its second oxidation peak (PA2).  相似文献   

11.
《Electroanalysis》2006,18(3):253-258
The anodic voltammetric behavior of carbaryl on a boron‐doped diamond electrode in aqueous solution is reported. The results, obtained by square‐wave voltammetry at 0.1 mol L?1 Na2SO4 and pH 6.0, allow the development of a method to determine carbaryl, without any previous step of extraction, clean‐up, preconcentration or derivatization, in the range 2.5–30.0×10?6 mol L?1, with a detection limit of 8.2±0.2 μg L?1 in pure water. The analytical sensitivity of this electrochemical method diminished slightly, from 3.07 mA mmol?1 L to 2.90 mA mmol?1L, when the electrolyte was prepared with water samples collected from two polluted points in an urban creek. In these conditions, the recovery efficiencies obtained were around 104%. The effect of other pesticides (fenthion and 4‐nitrophenol) was evaluated and found to exert a negligible influence on carbaryl determination. The square‐wave voltammetric data obtained for carbaryl were typical of an irreversible electrode process with mass transport control. The combination of square‐wave voltammetry and diamond electrodes is an interesting and desirable alternative for analytical determinations.  相似文献   

12.
采用微分脉冲阳极溶出伏安法, 研究了Ag+、Cu2+、Pb2+、Sn2+、Cd2+等多种共存金属离子在掺硼金刚石(BDD)表面双金属共沉积-共溶出电化学行为. 结果表明, 双金属在掺硼金刚石膜表面的共沉积-共溶出模型是由金属本身的析出电位, 金属之间的相互作用, 金属离子和溶液间的相互作用等多种因素决定的. 微分阳极溶出法的研究结果表明, 双金属在掺硼金刚石电极上的共沉积-共溶出过程表现出金属1溶出-金属2溶出、金属1溶出-析氢-金属2溶出、金属1溶出-金属合金溶出-金属2溶出、金属1溶出-析氢-金属2络合物形成-金属2溶出等四种模型.  相似文献   

13.
《Electroanalysis》2017,29(4):1180-1187
The voltammetric behavior of ramipril (RMP), an angiotensin‐converting enzyme inhibitor, was investigated for the first time in the literature on a boron‐doped diamond electrode (BDDE) using cyclic (CV) and square‐wave voltammetry (SWV). Its behavior was also considered in the presence of a thiazide diuretic, hydrochlorothiazide (HCTZ), for the simultaneous determination. The performance of BDDE and glassy carbon electrode (GCE) was compared, since RMP provides a high oxidation potential. It was observed that the anodic peak potentials for HCTZ and RMP at the BDDE were 1.23 and 1.67 V (vs . Ag/AgCl (3.0 mol L‐1 KCl)) by CV in BR buffer solution (pH 2.0), respectively. The influence of supporting electrolyte, pH and scan rate in the current response of these both drugs was examined to select optimum experimental conditions. By this way, the determination of RMP and its association with HCTZ using SWV and a BDDE was successfully applied in real samples (single and combined dosage forms), with results in close agreement at 95% confidence level with those obtained using high‐performance liquid chromatography.  相似文献   

14.
The electrochemical methods cyclic and square‐wave voltammetry were applied to develop an electroanalytical procedure for the determination of N‐nitrosamines (N‐nitrosopyrrolidine, N‐nitrosopiperidine and N‐nitrosodiethylamine) in aqueous solutions. Cyclic voltammetry was used to evaluate the electrochemical behaviors of N‐nitrosamines on boron‐doped diamond electrodes. It was observed an irreversible electrooxidation peak located in approximately 1.8 V (vs. Ag/AgCl) for both N‐nitrosamines. The optimal electrochemical response was obtained using the following square‐wave voltammetry parameters: f=250 Hz, Esw=50 mV and Es=2 mV using a Britton–Robinson buffer solution as electrolyte (pH 2). The detection and quantification limits determined for total N‐nitrosamines were 6.0×10?8 and 2.0×10?7 mol L?1, respectively.  相似文献   

15.
The present work describes the individual, selective and simultaneous quantification of acetaminophen (ACP) and tramadol hydrochloride (TRA) using a modification‐free boron‐doped diamond (BDD) electrode. Cyclic voltammetric measurements revealed that the profile of the binary mixtures of ACP and TRA were manifested by two irreversible oxidation peaks at about +1.04 V (for ACP) and +1.61 V (for TRA) in Britton‐Robinson (BR) buffer pH 3.0. TRA oxidation peak was significantly improved in the presence of anionic surfactant, sodium dodecyl sulfate (SDS), while ACP signal did not change. By employing square‐wave stripping mode in BR buffer pH 3.0 containing 8×10?4 mol L?1 SDS after 30 s accumulation under open‐circuit voltage, the BDD electrode could be used for quantification of ACP and TRA simultaneously in the ranges 1.0–70 μg mL?1 (6.6×10?6–4.6×10?4 mol L?1) and 1.0–70 μg mL?1 (3.3×10?6–2.3×10?4 mol L?1), with detection limits of 0.11 μg mL?1 (7.3×10?7 mol L?1) and 0.13 μg mL?1 (4.3×10?7 mol L?1), respectively. The practical applicability of the proposed approach was tested for the individual and simultaneous quantification of ACP and/or TRA in the pharmaceutical dosage forms.  相似文献   

16.
A new voltammetric procedure for the simultaneous determination of dopamine (DA) and paracetamol (PA) using boron doped diamond electrode modified with Nafion and lead films (PbF/Nafion/BDDE) was investigated. The use of this electrode resolved the overlapped voltammetric waves of DA and PA into well‐defined peaks with peak to peak separation of about 320 mV. Under the optimized experimental conditions in differential pulse voltammetric technique, DA and PA gave a linear response over the ranges 2.0×10?7–1.0×10?4 mol L?1*(R2=0.9996) and 5.0×10?7–1.0×10?3 mol L?1 (R2=0.9979), respectively. The detection limits were found to be 5.4×10?8 mol L?1 for DA and 1.4×10?7 mol L?1 for PA. They are lower, comparable or in some cases a little bit higher than those obtained using other electrochemical sensors. However, the proposed procedure of the sensor preparation is much simpler than procedures described in the literature with a lower detection limit. The proposed procedure was successfully applied to the determination of PA in some commercial pharmaceuticals as well as to the simultaneous determination of DA and PA in human urine, whole blood and serum samples directly without any separation steps.  相似文献   

17.
用疏水性离子液体1-丁基-3-甲基咪唑六氟磷酸盐([BMIM]PF6)和纳米MnO2作修饰剂,通过壳聚糖(CHIT)的成膜效应,构置了玻碳修饰电极([BMIM]PF6-MnO2-CHIT/GCE).在Britton-Robinson(B-R)缓冲液中研究了黄芩苷在修饰电极上的电化学行为,建立了测定黄芩胶囊中黄芩苷含量的...  相似文献   

18.
In the present study, an alternative platform for trace copper ions (Cu(II)) determination using a diamond electrode in combination with a disposable paper-based analytical device (d-PAD) has been proposed. First, the complexation between Cu(II) and 1,10-phenanthroline ligand was adsorptively accumulated onto a paper that is directly in contact with the diamond electrode and measured via square wave anodic stripping voltammetry. Under the optimal experimental conditions, the peak current was proportional to the concentration of Cu(II) in the range of 0.4–70 ng mL−1, and the detection limit was found to be 0.1 ng mL−1. Most importantly, this platform can be successfully applied to detect trace Cu(II) in different water samples (drinking water, tap water, groundwater and river water) with satisfactory results. Thus, the proposed d-PAD could be a highly efficient platform for trace Cu(II) determination in environmental samples.  相似文献   

19.
采用电聚合方法制备了聚烟酸修饰玻碳电极(PNA/GCE),并利用循环伏安法(CV)和差分脉冲伏安法(DPV)考察了盐酸吡哆辛(VB6)在该修饰电极上的电化学行为。结果表明,VB6在PNA/GCE上的氧化峰电流显著提高,电极反应为扩散控制的一电子两质子反应。利用差分脉冲伏安法对VB6进行测定,线性范围为0.08~400μmol/L,VB6的检出限为0.02μmol/L,测定结果的相对标准偏差为3.1%(n=8),加标回收率为95.8%~103.7%。该方法可用于VB6片中VB6含量的测定。  相似文献   

20.
An electroanalytical method for the simultaneous determination of paracetamol (PAR), caffeine (CAF), and orphenadrine (ORPH) using the square‐wave voltammetry (SWV) and a cathodically pretreated boron‐doped diamond electrode was developed. The method exhibits linear responses to PAR, CAF, and ORPH in the concentration ranges 5.4×10?7–6.1×10?5 M, 7.8×10?7–3.5×10?5 M, and 7.8×10?7–3.5×10?5 M, respectively, with detection limits of 2.3×10?7 M, 9.6×10?8 M, and 8.4×10?8 M, respectively. The proposed method was successfully applied in the simultaneous determination of these analytes in pharmaceutical formulations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号