首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
In this paper, a simple, convenient and sensitive electrochemical method has been developed for the determination of C.I. Direct Red 80. A gold nanoparticle modified carbon paste electrode was fabricated and used for study and sensitive determination of Direct Red 80 by cyclic voltammetry and differential pulse voltammetry. The overall analysis involved a two-step procedure: an accumulation step under open-circuit conditions, followed by voltammetric measurements of Direct Red 80 in a 0.1?M phosphate buffer solution at pH?=?3.0. The experimental conditions, such as the medium, pH and accumulation time, were optimised. The oxidation peak current was proportional to the concentration of Direct Red 80 from 5.0?×?10?8 to 5.0?×?10?7?M and 5.0?×?10?7 to 3.0?×?10?6?M, and the detection limit was 1.15?×?10?8?M (S/N?=?3). The proposed method was used to detect Direct Red 80 in natural water and sewage with good accuracy.  相似文献   

2.
A novel method for the determination of Pb2+ with bismuth film electrodes (BFEs) based on magneto-voltammetry was investigated. In the presence of a 0.6?T external magnetic field, square wave voltammetry of Pb2+ was performed with BFEs. A high concentration of Fe3+ was added to the analytes to generate a large cathodic current during the preconcentration step. A Lorentz force from the flux of net current through the magnetic field resulted in convection. Then, more Pb2+ deposited onto the electrode and larger stripping peak currents were observed. BFEs that were prepared by simultaneously depositing the bismuth and Pb2+ on an electrode offered a mercury-free environment for this determination. This method exhibits a high sensitivity of 4.61?µA?µM?1 for Pb2+ over the 1?×?10?8 to 1?×?10?6?M range. A detection limit as low as 8.5?×?10?10?M was obtained with only 1-min preconcentration. The method was successfully applied to determine Pb2+ in real water samples.  相似文献   

3.
An electroanalytical method for the simultaneous determination of paracetamol (PAR), caffeine (CAF), and orphenadrine (ORPH) using the square‐wave voltammetry (SWV) and a cathodically pretreated boron‐doped diamond electrode was developed. The method exhibits linear responses to PAR, CAF, and ORPH in the concentration ranges 5.4×10?7–6.1×10?5 M, 7.8×10?7–3.5×10?5 M, and 7.8×10?7–3.5×10?5 M, respectively, with detection limits of 2.3×10?7 M, 9.6×10?8 M, and 8.4×10?8 M, respectively. The proposed method was successfully applied in the simultaneous determination of these analytes in pharmaceutical formulations.  相似文献   

4.
A new chemically modified carbon paste electrode is fabricated to determine lead ion concentration in its trace level in aqueous media with differential pulse voltammetry (DPV). The best performance is obtained by the carbon paste electrode composition including 20% of dithiodibezoic acid (DDA), 80% of high purity graphite powder and 60?µL of colloidal gold nanoparticle (AuNP) solution. The proposed electrode has a wide linear calibration response from 1?×?10?9 to 6?×?10?5 M with a detection limit of 6.6?×?10?10?M, at pH 3.5. Seven replicate determination of 5?×?10?8?M of lead ion concentration gives a relative standard deviation of 3.33%. The modified sensor is applied to determine lead contents in some environmental and biological Samples with satisfactory results.  相似文献   

5.
The electrochemical behavior of D ‐penicillamine (D ‐PA) studied at the surface of ferrocene carboxylic acid modified carbon paste electrode (FCAMCPE) in aqueous media using cyclic voltammetry and double step potential chronoamperometry. It has been found that under optimum condition (pH 7.00), the oxidation of D ‐PA at surface of such an electrode is occurred about 420 mV less positive than that an unmodified carbon paste electrode (CPE). The catalytic oxidation peak current was linearly dependent on the D ‐PA concentration and a linear calibration curve was obtained in the ranges 7.5×10?5 M – 1.0×10?3 M and 6.5×10?6 M?1.0×10?4 M of D ‐PA with cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods respectively. The detection limits (3σ) were determined as 6.04×10?5 M and 6.15×10?6 M. This method was also used for the determination of D ‐PA in pharmaceutical preparation (capsules) by standard addition method.  相似文献   

6.
《Analytical letters》2012,45(15):2430-2443
Abstract

A highly sensitive method to determine of indium is proposed by adsorption stripping differential pulse cathodic voltammetry (AdSDPCV) method. The complex of indium ions with xylenol orange is analyzed based on the adsorption collection onto a hanging mercury drop electrode (HMDE). After accumulation of the complex at ?0.20 V vs. Ag/AgCl reference electrode, the potential is scanned in a negative direction from ?0.40 to ?0.75 V with the differential pulse method. Then, the reduction peak current of In(III)–XO complex is measured. The influence of chemical and instrumental variables was studied by factorial design analysis. Under optimum conditions and accumulation time of 60 s, linear dynamic range was 0.1–10 ng/ml (8.7 × 10?10 to 8.7 × 10?8 M) with a limit of detection of 0.03 ng/ml (2.6 × 10?10 M); at accumulation time of 5 min, linear dynamic range was 0.04–10 ng/ml (3.4 × 10?10 to 8.7 × 10?8 M) with a limit of detection of 0.013 ng/ml (1.1 × 10?10 M). The applicability of the method to analysis of real samples was assessed by the determination of indium in water, alloy, and jarosite (zinc ore) samples.  相似文献   

7.
Differential pulse cathodic adsorptive stripping (DPCAdSV) and square wave cathodic adsorptive stripping (SWCAdSV) voltammetric methods were developed for the determination of antimony and lead in gunshot residues. Linear working ranges for DPCAdSV and SWCAdSV methods were (2.0×10?9–5.0×10?7) M and (2.0×10?9–7.0×10?7) M for antimony and 2.0×10?9–3.0×10?7 M (both methods) for lead. The detection of antimony limits were found to be 1.3×10?9 M for DPCAdSV and 7.3×10?10 M for SWCAdSV while the corresponding values for lead were 3.0×10?9 M and 5.8×10?10 M. Antimony and lead contents obtained by these methods in gunshot residues are in good agreement with those obtained by graphite furnace atomic absorption spectrometric method within a confidence limit of 95%.  相似文献   

8.
A multi-walled carbon nanotubes (MWNTs) modified glassy carbon electrode (MWNT-GCE) was used to study the electrochemical behaviour of1-hydroxypyrene (1-OHP) and applied to its determination. The results showed that the modified electrode had a strong adsorptive ability to 1-OHP and enhances its electrochemical signal. By square wave voltammetry, the linear relationship of 1-OHP was 6?×?10?9???8?×?10?7?mol?L?1 with a linear correlation coefficient of 0.996, and the detection limit was 1?×?10?10?mol?L?1. Compared with other published methods, this newly proposed method possesses many advantages such as very low detection limit, fast response, low cost and simplicity. And this method was applied successfully in the determination of 1‐OHP in real human urine samples.  相似文献   

9.
《Analytical letters》2012,45(7):1411-1420
Abstract

Cadmium in the presence of 0.04 M NaCl as the electrolyte was determined using stripping voltammetry with superimposed constant amplitude pulses of negative polarity (SVPNP) or positive polarity (SVPPP), and differential pulses stripping voltammetry using rotating disc glass carbon electrode (RDGCE). The SVPNP was found to give the greatest sensitivity. The anodic peak was obtained at potential ?850 to ?795 mV due to the oxidation of cadmium to cadmium(II). Linear calibration curves were obtained in the concentration range between 1.5×10?9–2×10?10 M. The relative standard deviation is 4.25% at very low concentration of 2×10?10 M. This method was successfully applied to the determination of cadmium in some foodstuffs (wheat and its products, vegetables) after acid digestion.  相似文献   

10.
《Analytical letters》2012,45(11):1783-1802
Abstract

Griseofulvin is an antifungal antibiotic used to treat various pathogenic mycotic diseases. The voltammetric behavior of griseofulvin at a hanging mercury drop electrode in Britton‐Robinson buffers of pH 2–11.5 was studied and discussed. A fully validated sensitive square‐wave adsorptive cathodic stripping voltammetric procedure was described for direct determination of bulk griseofulvin substance. The procedure was based on the reduction of the >C?O double bond of griseofulvin molecule following its preconcentration onto a hanging mercury drop electrode in a Britton‐Robinson buffer of pH 10. Limits of detection (LOD) and quantitation (LOQ) of 5.8×10?10 M and 1.93×10?9 M bulk griseofulvin were achieved, respectively. The proposed stripping voltammetric procedure was successfully applied to assay griseofulvin in tablets and in spiked human serum and urine samples. LOD of 8.65×10?10 M and 6.6×10?9 M and LOQ of 2.88×10?9 M and 2.2×10?8 M griseofulvin in spiked human serum and urine samples, respectively, were achieved.  相似文献   

11.
A lead film plated in situ at a carbon paste support was tested as a novel, potential electrode for adsorptive stripping voltammetric determination of cobalt traces in an ammonia buffer solution. To show the practical applicability of the new electrode, a catalytic adsorptive Co system in a supporting electrolyte containing 0.1 M ammonia buffer, 5×10?4 M nioxime and 0.25 M nitrite was selected and investigated as a model solution. Pb and Co ions were simultaneously accumulated in situ on the electrode surface: Pb ions electrochemically at ?1.3 V) and then at ?0.75 V, at which potential the Co(II)‐nioximate complex was also pre‐concentrated via adsorption. Instrumental parameters, such as the time of nucleation and formation of Pb film deposits, the time of accumulation of the Co‐nioxime complex at the PbF/CPE, and the procedures of electrode regeneration, were optimized to obtain good reproducibility and sensitivity of the Co response. The optimized procedure yields favorable and highly stable stripping responses with good precision (RSD=3% for a 5×10?8 M Co) and good linearity (up to 5×10?7 M, coefficient of determination, R=0.996). The detection limit was 4×10?10 M Co (0.023 μg L?1) for an accumulation time of 120 s. The method enables the determination of Co in the presence of high excesses of Ni or Zn. The voltammetric data were correlated with the structural characterization by scanning electron microscopy (SEM) and X‐ray fluorescence spectroscopy (XRF).  相似文献   

12.
For the first time, a novel carbon nanotube bed electrode impregnated with silver–nanoparticles (AgNPs) for the determination of trace amounts of gabapentin (GBP) is described. We synthesized the AgNPs via a new procedure. The voltammetric behavior of the electrode was investigated by cyclic voltammetry. There were linear relationships in the ranges from 3.1×10?9 to 2.9×10?2 M and from 1.0×10?8 to 1.0×10?2 GBP with square wave and differential pulse voltammetric peak currents, respectively. The detection limits were 5.6×10?10 and 9.7×10?9 M, respectively. The electrode showed excellent response over a period of 2 months and was successfully applied in human plasma and pharmaceutical capsular products.  相似文献   

13.
A bismuth‐film electrode (BiFE) ex situ electrochemically deposited onto a copper substrate has been presented for paraquat determination. The bismuth film was electrochemically deposited at an applied potential of ?0.18 V vs. Ag/AgCl (3.0 M KCl) for 200 s. The analytical curve was linear in the paraquat concentration range from 6.6×10?7 M to 4.8×10?5 M with a limit of detection of 9.3×10?8 M. The method presented satisfactory results at a confidence level of 95% and the performance was evaluated in water samples.  相似文献   

14.
A hemin bulk modified carbon electrode with Adeps neutralis (solid fat) as binder was developed for the determination of antimalarial endoperoxide artemisinin in plant matrix. The hemin modified electrode showed significant catalytic activity for the electrochemical reduction of artemisinin at about ?380 mV vs. Ag/AgCl in phosphate buffer solution of pH 7 by using cyclic and differential pulse voltammetry. Under optimized conditions strict linearity between artemisinin concentration and height of the cathodic catalytic current peak was observed in 4.8×10?6–7.8×10?5 M concentration range (R=0.9991) when using differential pulse voltammetry. The detection limit was calculated as 1.4×10?6 M of artemisinin. The developed electroanalytical device is suitable for the determination of artemisinin in Artemisia annua extracts.  相似文献   

15.
《Analytical letters》2012,45(8):1711-1717
Abstract

In a solution containing 0.005M borax medium (PH= 8? 10). 0.03% ascorbic acid and 0.001% gelatin, a fine sensitive adsorptive reduction peak of manganese appeared at ?1.53v (vs.SCE) on a hanging mercury electrode by fast speed scanning voltammetry. The derivative peak current is directly proportional to the concentration of manganese in the range from 1.0×10?8M to 2.0×10?6M. The detection limit is 3.0×10?9M. Using this method, we have successfuly determined tracesof Mn in water and strawberry samples.  相似文献   

16.
The determination of Pb and Cd with a Nafion‐modified glassy carbon electrode and Cu‐DPABA complex (Cu‐DPABA–NA/GCE; DPABA is methyl 3,5‐bis{bis‐[(pyridin‐2‐yl)methyl]amino}methyl‐benzoate) as an alternative electrode for anodic stripping voltammetry was described. Pb and Cd were accumulated in acetate buffer pH 4 at a potential of ?1.4 V (vs. Ag/AgCl electrode) for 120 s followed by a DPASV scan from ?1.2 to ?0.2 V. Under optimum conditions the calibration curves were linear in the range of 4.8×10?9–5.0×10?5 and 5.0×10?9–5×10?5 mol L?1 for Pb and Cd, respectively. Detection limits were 1.8×10?9 and 1.2×10?9 mol L?1 for Pb and Cd, respectively. Different parameters and conditions, such as membrane ingredients, accumulation time, potential and pH value were optimized. A study of interfering substances was also performed. A significant increase in current was achieved at the modified electrode in comparison with the bare glassy carbon electrode. The validation of the proposed method was made by Pb and Cd determination in the certified reference material Groundwater CRM 610 (BCR, Community Bureau of Reference, Brussels, Belgium). The electrode was successfully applied for determination of Pb and Cd in river water with a high content of organic contaminants without any pretreatment.  相似文献   

17.
This work presents a sol‐gel based biosensor for atrazine determination which has been obtained by introducing the enzyme polyphenol oxidase from apple tissue in a sol‐gel matrix. Apple tissue acts as a molecular recognition element. Atrazine is an inactive compound electrochemically; redox coupling of dopamine was used for studying atrazine behavior. Atrazine was determined by monitoring the inhibition power of polyphenol oxidase activity. The measurements were performed in 0.1 M KH2PO4‐NaOH buffer (pH 7.5). The effect of various experimental parameters such as pH, concentration of buffer, concentration of dopamine, incubation time and matrix composition has been investigated for optimum analytical performance. The biosensor consisted of 10.3% (w/w) of apple tissue. The bioelectrode exhibits a linear response for dopamine and atrazine concentrations in the range of 5.66 × 10?6?2.27 × 10?3M and 1 × 10?5 ?1 × 10?4 M with a detection limit of 4.2 × 10?6 and 5.5 × 10?6 M, respectively. A correlation coefficient of 0.9945 and a relative standard deviation (R.S.D.) of 3.29% for dopamine, 0.9944 and 3.69% for a trazine were achieved.  相似文献   

18.
ABSTRACT

In the present study, a simple, cheap and sensitive electrochemical method based on a cathodically pretreated boron-doped diamond (CPT-BDD) electrode is described for the detection of triclosan with the cationic surfactant (cetyltrimethylammonium bromide, CTAB) media. The oxidation of triclosan was irreversible and exhibited an adsorption controlled process. The sensitivity of the adsorptive stripping voltammetric measurements was significantly improved with addition of CTAB. Using square-wave stripping mode, a linear response was obtained for triclosan determination in Britton-Robinson buffer solution at pH 9.0 containing 2.5 × 10?4 M CTAB at around + 0.67 V (vs. Ag/AgCl) (after 30 s accumulation at open-circuit condition). The method could be used in the range of 0.01–1.0 μg mL?1 (3.5 × 10?8–3.5 × 10?6 M), with a detection limit of 0.0023 μg mL?1 (7.9 × 10?9 M). The feasibility of the proposed method for the determination of triclosan in water samples was checked in spiked tap water.  相似文献   

19.
《Analytical letters》2012,45(13):2045-2055
Abstract

A new method for determination of trace indium is proposed by the adsorption stripping voltammetry (ASV) using a Nafion‐modified glassy carbon electrode (NMGCE). This chemically modified electrode (CME) shows a better stability. A sensitive oxidation peak was observed, and the anodic peak potential is ca. ?0.548 V (vs. SCE). The influences of various experimental parameters on the current peak were completely studied. Under the optimized condition, the method has been applied to the determination of indium in water samples. There is a good linear relationship between the peak current (ip) and indium(III) concentration in the range of 1.0×10?9–1.0×10?7 mol/l, and the limit of detection is 7.5×10?10 mol/l.  相似文献   

20.
A simple and sensitive differential pulse stripping voltammetric method was developed for the determination of antimony(III) using a selenium-doped carbon paste electrode modified with an ionic liquid, graphene, and gold nanoparticles. The conditions, including the mass of graphene, concentration of hydrochloric acid, deposition potential, and deposition time were optimized by single-factor experiments. Under the optimal conditions, a linear equation of ISb(III) (µA)?=??16.9882???11.0929 c (µmol/L) (R?=?0.9965) and a detection limit of 2.7?×?10?8?mol/L were obtained for 8.0?×?10?8 to 4.8?×?10?6?mol/L antimony(III). The response shows that the sensor enhances the sensitivity of antimony due to the high conductivity and large surface areas of the ionic liquid, graphene, and gold nanoparticles. This electrode may provide a new sensing platform for the determination of antimony.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号