首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
李枚枚  王雅静 《分析化学》2000,28(4):428-431
研究了在火焰原子吸收光谱法中三乙醇胺及十二烷基三甲基氯化铵对钼的增感作用。在仪器最佳工作条件及合适的酸存在下,60g/L三乙醇胺及16g/L十二烷基三甲基氯化铵可使钼的吸光度增感70.4%,且能消除多种共存元素的干扰。建立了合金风中大于0.05%钼的测定方法。  相似文献   

2.
采用火焰原子吸收光谱法测定镍基高温合金中的镉,样品以硝酸-氢氟酸-水混合溶液(1+1+1)前处理,选择Cd 228.8nm为分析线进行测定,并通过标准加入法校正基体效应。考察了消解酸的选择,仪器工作参数的调整,基体和共存离子对镉测定的影响。结果表明,镍基高温合金中镉的检出限为0.088μg/g。加标回收率为94.1%~109%,结果的相对标准偏差(RSD,n=8)在0.54%~1.6%。方法操作简便、分析速度快、准确度好,适用于镉含量在0.0001%~0.001%的镍基高温合金中的测定。  相似文献   

3.
采用火焰原子吸收光谱法测定镍基高温合金中的镉,样品以硝酸-氢氟酸-水混合溶液(1+1+1)前处理,选择Cd 228.8 nm为分析线进行测定,并通过标准加入法校正基体效应。考察了消解酸的选择,仪器工作参数的调整,基体和共存离子对镉测定的影响。结果表明,镍基高温合金中镉的检出限为0.088μg/g。加标回收率为94.1%~109%,结果的相对标准偏差(RSD,n=8)在0.54%~1.6%。方法操作简便、分析速度快、准确度好,适用于镉含量在0.0001%~0.001%的镍基高温合金中的测定。  相似文献   

4.
Amberlite XAD-4 modified with N-para-anisidine-3,5-di-tert-butylsalicylaldimine was investigated as a new chealting sorbent for the selective separation and preconcentration of Cu(II). The metal ion was retained by chemical sorption on the modified resin, eluted by hydrochloric acid, and determined by high-resolution continuum source flame atomic absorption spectrometry. The prepared resin was characterized for the solid-phase extraction of Cd2+, Co2+, Cr3+, Cu2+, Fe3+, Mn2+, Ni2+, Pb2+, and Zn2+ in a column. The influence of the pH, the mass of solid phase, eluent, flow rate, and sample volume was optimized. Using the optimum conditions, only Cu(II) showed quantitative sorption at the 95% confidence level, and the recoveries of the other metal ions were below 80%. A preconcentration factor 125 was obtained for Cu(II) with a limit of detection of 0.56?µg?L?1. The method was used for the determination of Cu(II) in tap water, river water, tomato leaves, and fish. The relative standard deviation and the relative error were lower than 7%.  相似文献   

5.
Almond skin was used as a biosorbent by solid-phase extraction for the preconcentration of manganese(II) before the determination by flame atomic absorption spectrometry. Characterization of almond skin was performed by infrared spectroscopy. The functional groups of the almond skin surface were shown to be beneficial for the adsorption of manganese(II). At pH 6.0, the manganese(II) ions were retained on the almond skin and afterward quantitatively eluted using 1.5?mol?L?1 nitric acid. The pH, flow rate and volume of sample, concentration, and flow rate of eluent and interfering ions were characterized. Using a sample size of 30?mL, a linear dynamic range of 1–120?µg?L?1 was obtained. A detection limit of 0.24?µg?L?1 manganese(II) and a relative standard deviation of 1.6% at 30?µg?L?1 were achieved. The accuracy of the present procedure was evaluated by the determination of manganese(II) in a certified reference material (GSB07-1189-2000). The protocol was also used for the determination of manganese(II) in wastewater. The fortified recoveries were from 99.0 to 99.4%.  相似文献   

6.
A column solid-phase extraction (SPE) preconcentration method was developed for the determination of Cd, Co, Cu, Ni and Zn ions in natural water samples by flame atomic absorption spectrometry. The procedure is based on the retention of analytes in the form of 2-acetylmercaptophenyldiazoaminoazobenzene (AMPDAA) complexes on a short column of AMPDAA-XAD-4 resin from buffered sample solution and subsequent elution with hydrochloric acid plus sodium chloride. Important SPE parameters were optimized using model solutions. The loading half-time, t1/2, for Cd, Co, Cu and Zn was found to be less than 5min, and for Ni the value was 12min. The detection limit for Cd, Co, Cu, Ni and Zn was 0.028, 0.064, 0.042, 0.023 and 0.16µgL–1, respectively, and the quantification limit was 0.043, 0.11, 0.099, 0.044 and 0.29µgL–1, respectively. The AMPDAA-XAD-4 resin has good selectivity for Cd, Co, Cu, Ni and Zn over several electrolytes, especially over earth alkaline metals with tolerance limits of 0.05molL–1. The method was validated by analysing a standard reference material (GBW 08301), and it was found that the results agree with those quoted by the manufactures. The developed method was applied to the determination of trace metal ions in tap water and river water samples with satisfactory results.  相似文献   

7.
In this study, a method of dispersive liquid phase microextraction combined with the flame atomic absorption spectrometry was proposed for the determination of trace Hg using diphenylthiocarbazone as chelating reagent. Several factors which have effect on the microextraction efficiency of Hg, such as pH, extraction and dispersive solvent type and their volume, concentration of the chelating agent, extraction time were investigated, and the optimized experimental conditions were established. After extraction, the enrichment factor was 68. The detection limit of the method was 45 ng mL?1, and the relative standard deviation for eight determinations of 2 μg mL?1 Hg was 1.7%. The results for the determination of Hg in environmental water samples (tap water, well water, mineral water and Caspian sea water) have demonstrated the applicability of the proposed method.  相似文献   

8.
于洪梅  孙巍  陈明丽  田永  王建华 《分析化学》2010,38(12):1721-1726
以NaOH为沉淀试剂,将水样中的Ag+在线生成Ag2O沉淀,并即时被滞留在硅胶负载的碳纳米管表面。被吸附的Ag2O沉淀用HNO3(10%,V/V)洗脱,并用火焰原子吸收法检测。当进样体积为5.4mL时,线性范围为1~120μg/L,富集系数为34.5;检出限为0.35μg/L;相对标准偏差为0.5%(40μg/L,n=7),采样频率为47次/h。结果表明:本方法的富集系数、检出限及精密度均明显优于以纯碳纳米管和纯硅胶微珠为吸附剂收集Ag2O的体系。将此系统应用于实际水样中银的测定,加标回收率在96%~108%之间。  相似文献   

9.
《Analytical letters》2012,45(4):632-646
A new solid phase extraction method based on the application of polyaniline as the sorbent and calmagite as the anionic chelating agent is reported for selective preconcentration of trace copper, prior to its determination by microsample injection system-flame atomic absorption spectrometry. The parameters that influence the extraction and chelate formation were optimized. The copper was retained on a polyaniline minicolumn at pH 4.0 and eluted with 2.0 mL of 3.0 mol L?1 nitric acid. Under the optimum conditions, the limit of detection, the relative standard deviation, and the preconcentration factor were 1.98 µg L?1, less than 5.4%, and 50 to 200, respectively. The method was validated through the analysis of certified reference water samples and standard addition measurements. Quantitative recoveries between 93.4% and 103.5% were obtained. The method was successfully applied to the determination of copper in water.  相似文献   

10.
A facile, reliable and reproducible method for speciation and determination of the traces amounts of chromium(III) in waste water has been developed. The method was based on complex formation on the surface of the ENVI‐18 DSK? disks followed by stripping of the retained species by minimum amounts of appropriate organic solvents. The elution was efficient and quantitative. The effects of potential interfering ions, pH, ligand amount, stripping solvent, and sample flow rate were also investigated. Under the optimal experimental conditions, the break‐through volume was found to be about 1500 mL providing a preconcentration factor of 300. The maximum capacity of the disks was found to be 225 ± 3.9 μg for Cr3+. A limit of detection of 0.02 ng.mL ?1 was obtained, and the method was applied for determination of chromium in electroplating industries waste water located in the eastern regions of Tehran.  相似文献   

11.
A method was developed to sequentially assay ten rare earth elements by high-resolution continuum source flame atomic absorption spectrometry. The rare earth elements Nd, Sm, Eu, Tb, Ho, Er, Tm, Yb, Y, and Sc were assayed in environmental water samples which were also analyzed by a reference inductively coupled plasma-mass spectrometry protocol. The samples did not require pretreatment or preconcentration. Interferences for the method were evaluated. Experimental parameters, including the flame composition, burner height, ionization buffers and number of pixels, were optimized. The volume necessary to run measurements in triplicate was only 15?mL per sample. The accuracy, precision and linear range were evaluated. The limits of detection ranged from 0.003 to 0.473?µg mL?1 for the most sensitive (Yb) to the least sensitive (Tb) element.  相似文献   

12.
MOGHIMI  Ali 《中国化学》2007,25(11):1663-1668
A simple and reproducible method for the rapid extraction and determination of trace amounts of copper(Ⅱ) ions using octadecyl-bonded silica membrane disks modified by 1,5-diphenylcarbazide (DPC) and atomic absorption spectrometry was presented, which was based on complex formation on the surface of the ENVI-18 DISK^TM disks followed by stripping of the retained species by minimum amounts of appropriate organic solvents. The elution was efficient and quantitative. The effect of potential interfering ions, pH, ligand amount, stripping solvent, and sample flow rate were also investigated. Under the optimal experimental conditions, the break-through volume was found to be about 1000 mL providing a preconcentration factor of 400. The maximum capacity of the disks was found to be (255±5) lag for Cu^2+, and the limit of detection of the proposed method was 5 ng per 1000 mL. The method was applied to the extraction and recovery of copper in different water samples.  相似文献   

13.
In this study, a novel sorbent material bearing a bis(aldimine) group was designed and successfully synthesized by covalently bonding a 2-[N,N′-bis(salicylaldimine)]aminoethyl amine ligand to the silica gel surface that was characterized by carbon, hydrogen, and nitrogen elemental analysis, thermogravimetric analysis, and the Fourier transform infrared spectroscopy technique. The sorbent was used for the online solid-phase extraction (SPE) of Cd(II), Cu(II), and Co(II) ions for their determination at trace concentration levels by flame atomic absorption spectrometry. The effective factors for the online SPE such as the pH and the flow rate of the sample solution, and type, volume, and flow rate of eluent were investigated. The concentration levels of Cd(II), Cu(II), and Co(II) were measured in certified reference materials including Virginia tobacco leaves (CTA-VTL-2) and water-trace elements (NWTM-15.2) to validate this method. The metal levels in environmental water were determined by this method, and the values were checked by spiking and recovery experiments and independent analysis by inductively coupled plasma-mass spectrometry. The adsorption capacities of the sorbent were found to be 41.2, 31.6, and 25.6?mg/g for Cd(II), Cu(II), and Co(II), respectively. This method was also successfully used for the determination of Cd(II), Cu(II), and Co(II) concentrations in rice and molasses.  相似文献   

14.
采用硫脲络合–火焰原子吸收光谱法测定低硅铝合金中的银元素含量。实验探讨了酸度及硫脲用量对银测定的影响及铝合金中基体元素与共存元素对银元素分析线的干扰情况。结果表明:选用9%的盐酸和3%的硝酸溶解试样最好,加入5 mL 50 g/L硫脲溶液可消除氯离子对试验结果的影响,基体铝元素和其它共存元素不干扰银的测定。根据低硅铝合金中银元素的含量范围,合成系列标准溶液,建立工作曲线,工作曲线的线性范围为0.05%~0.50%。银元素含量为0.30%的样品测定结果的相对标准偏差为0.15%(n=8),标准加入回收率为96.8%~98.5%。该方法操作简便、重现性好、测量结果准确可靠。  相似文献   

15.
A novel simple and sensitive, time-based flow injection solid phase extraction system was developed for the automated determination of metals at low concentration. The potential of the proposed scheme, coupled with flame atomic absorption spectrometry (FAAS), was demonstrated for trace lead and chromium(VI) determination in environmental water samples. The method, which was based on a new sorptive extraction system, consisted of a microcolumn packed with glass fiber coated with sol–gel poly (diphenylsiloxane) (sol–gel PDPS), which is presented here for the first time. The analytical procedure involves the on-line chelate complex formation of target species with ammonium pyrrolidine dithiocarbamate (APDC), retention onto the hydrophobic sol–gel sorbent coated surface of glass fibers, and finally elution with methyl isobutyl ketone prior to atomization. All main chemical and hydrodynamic factors, which affect the complex formation, retention, and elution of the metal, were optimized thoroughly. Furthermore, the tolerance to potential interfering ions appearing in environmental samples was also explored. Enhancement factors of 215 and 70, detection limits (3 s) of 1.1 μg·L−1 and 1.2 μg·L−1, and relative standard deviations (RSD) of 3.0% (at 20.0 μg·L−1) and 3.2% (at 20.0 μg·L−1) were obtained for lead and chromium(VI), respec tively, for 120 s preconcentration time. The trueness of the developed method was estimated by analyzing certified reference materials and spiked environmental water samples.  相似文献   

16.
This paper describes the development of a cloud point extraction procedure for the determination of manganese in saline effluents by flame atomic absorption spectrometry (FAAS). The optimization step was performed using the Doehlert matrix involving the following variables: buffer concentration, pH and centrifugation time. The validation process was assessed as: parameters of the analytical curve, precision, effect of other ions in the proposed procedure, robustness test and accuracy. The proposed procedure allows the determination of manganese with a detection limit (3δ/S) of 0.60 μg L−1, and a precision expressed as relative standard deviation (RSD) of 2.2 (n = 8) and 1.5% (n = 8) for a manganese concentration of 1 and 5 μg L−1, respectively. The pre-concentration factor obtained was 84. The recovery achieved for the determination of manganese in the presence of several other metal ions demonstrated that this procedure could be satisfactorily applied to the analysis of environmental samples. The accuracy was confirmed by the analysis of CRM trace elements in water (NIST 1643d). This procedure was applied to the determination of manganese in saline effluents of a petroleum refinery. For three analyzed samples the manganese content varied between 44.9 and 67.9 μg L−1.  相似文献   

17.
A sensitive and simple solid‐phase preconcentration procedure for the determination of trace amount of lead by flame atomic absorption spectrometry (FAAS) is developed. The method is based on the adsorption of Pb2+ on the column of fine grinded eucalyptus stem adsorbent, elution of the column by nitric acid and subsequent determination by FAAS. The effect of different variables such as pH, eluent type, flow rate and interfering ions on the recovery of the analyte was investigated and optimum conditions were established. The adsorption of lead onto fine grinded eucalyptus stem can formally be described by a Langmuir equation with a maximum adsorption capacity of 4.49 mg g?1. A preconcentration factor of 50 was achieved using the optimum conditions. The calibration graph was linear in the range 10–125 ng mL?1 of lead in the initial solution with r = 0.9982. The limit of detection based on 3Sb criterion was 4.5 ng mL?1 and the relative standard deviation for eight replicate measurements of 30 and 80 ng mL?1 of iron was 3.6 and 2.8%, respectively. The method was successfully applied to the determination of lead added to well, tap and wastewater samples.  相似文献   

18.
本文试验了稀土元素对空气-乙炔火焰原子吸收测定锶的影响,并且选择镧作了重点研究,发现不同镧盐对测定锶的影响各不相同,当存在每mL1500μg镧(高氯酸盐)时,硝酸浓度在比较宽的范围内不影响锶的测定,本文建立建立了Sr-La(ClO4)3-HNO3体系中测量锶的新方法,该方法用于人工混合稀土样品中Sr的测定,获得满意的结果。  相似文献   

19.
《Analytical letters》2012,45(16):2566-2580
Multiwalled carbon nanotubes were modified by Fe3O4 nanoparticles with application for the preconcentration of metals. The modified materials were characterized by infrared spectroscopy, transmission electron microscopy, and X-ray diffraction. The Fe3O4 nanoparticle modified multiwalled carbon nanotubes were used as sorbents for the extraction of cadmium and lead from maca prior to analysis by flame atomic absorption spectrometry. The amount of nanoparticles, pH, adsorption time, coexisting ions, eluent solution, and reuse of the material were characterized to optimize the recoveries of the analytes. Under the optimum conditions, the calibration curves were linear from 0.05 to 20 milligrams per liter for cadmium and from 0.05 to 25 milligrams per liter for lead. The limits of detection were 0.32 and 0.57 micrograms per liter while the relative standard deviations were 2.1 and 1.9 percent, respectively. The method was employed for the determination of cadmium and lead in maca and recoveries between 94.8 and 105.6 percent were obtained.  相似文献   

20.
An adsorbent calix[4]arene carboxylic acid was employed as the adsorption material for on-line flow injection( FI) micro-column preconcentration coupled with flame atomic absorption spectrometry(FAAS) determination of trace heavy metals(Cu, Pb, Co, Ni and Cd). Parameters such as the pH, loading time and flow rate of sample, and the concentration, volume and flow rate of eluent were optimized. The enrichment factors are 50.0, 56.5, 11.6, 12.1 and 19.1 for Cu, Pb, Co, Ni, and Cd, respectively, and a sample throughput of 20 h-1 was obtained. The limits of detection for Cu, Pb, Co, Ni, and Cd were in a range of 1.56―3.91 μg/L, and the relative standard deviations(RSDs) were less than 2.76%(n=7). Furthermore, the proposed method was successfully applied to the determination of Cu, Pb, Co, Ni, and Cd in certified reference materials and various water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号