首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 296 毫秒
1.
We have developed a sensor for the square wave anodic stripping voltammetric determination of Pb(II). A glassy carbon electrode was modified with a thin film of an antimony/poly(p-aminobenzene sulfonic acid) composite in air-saturated aqueous solution of pH 2.0. Compared to a conventional antimony film electrode, the new one yields a larger stripping signal for Pb(II). The conditions of polymerization, the concentration of Sb(III), the pH value of the sample solution, the deposition potential and time, frequency, potential amplitude, and step increment potential were optimized. Under the optimum conditions, a linear response was observed for Pb(II) in the range of 0.5 to 150.0 μg?L?1. The detection limit for Pb(II) is 0.1 μg?L?1.
Figure
The surface of a glassy carbon electrode (GCE) was modified by electropolymerization of p-aminobenzene sulfonic acid (p-ABSA) and the modified electrode was then prepared by in situ depositing antimony and target metal on the poly(p-ABSA) coated glassy carbon electrode. The antimony/poly(p-ABSA) film electrode displays high electrochemical activity in giving a peak current that is proportional to the concentration of Pb(II) in a certain range.  相似文献   

2.
We describe a novel magnetic metal-organic framework (MOF) for the preconcentration of Cd(II) and Pb(II) ions. The MOF was prepared from the Fe3O4-pyridine conjugate and the copper(II) complex of trimesic acid. The MOF was characterized by IR spectroscopy, elemental analysis, SEM and XRD. A Box-Behnken design through response surface methodology and experimental design was used to identify the optimal parameters for preconcentration. Extraction time, amount of magnetic MOF and pH value were found to be critical factors for uptake, while type, volume, concentration of eluent, and elution time are critical in the elution step. The ions were then determined by FAAS. The limits of detection are 0.2 and 1.1 μg?L?1 for Cd(II), and Pb(II) ions, respectively, relative standard deviations are <4.5% (for five replicates at 50 μg?L?1 of Cd(II) and Pb(II) ions), and the enrichment capacity of the MOF is at around 190 mg?g?1 for both ions which is higher than the conventional Fe3O4-pyridine material. The magnetic MOF was successfully applied to the rapid extraction of trace quantities of Cd(II) and Pb(II) ions in fish, sediment, and water samples.
Figure
Schematic illustration of synthesized magnetic MOF-pyridine nanocomposite  相似文献   

3.
Graphene nanosheets were modified with amino groups and the resulting material was used as a sorbent for the extraction of cadmium and lead ions. The nanosheets were characterized by IR spectroscopy, transmission electron microscopy, thermal gravimetric analysis and elemental analysis. The effects of sample pH, eluent parameters (type, concentration and volume of eluent), flow rates (of both sample and eluent), and of a variety of other ions on the efficiency of the extraction of Cd(II) and Pb(II) were optimized. Following solid phase extraction, the elements were determined by FAAS. The limits of detection are <0.9 μg L?1 for Pb(II) and <5 ng L?1 for Cd(II). The relative standard deviations are <2.2 %. The method was validated by analyzing several certified reference materials and was then used for Pb(II) and Cd(II) determination in natural waters and vegetables.
Figure
In this work, grapheme oxide nanosheets were modified with amino and tri-amino groups and their application were investigated in Cd(II) and Pb(II) determination in food sample. The results show high preconcentration factor and adsorption capacities for these nanosheets.  相似文献   

4.
We report on a protocol for a simultaneous competitive immunoassay for tetracycline (TC) and chloramphenicol (CAP) on the same sensing interface. Conjugates of TC and of CAP with bovine serum albumin were first co-immobilized on a glassy carbon electrode modified with gold nanoparticles. In parallel, monoclonal anti-TC and anti-CAP antibodies were conjugated onto CdS and PbS nanoclusters, respectively. In a typical assay, the immobilized haptens and the added target analytes competed for binding to the corresponding antibodies on the nanoclusters. Subsequently, Cd(II) and Pb(II) ions are released from the surface of the corresponding nanoclusters by treatment with acid and then were detected by square wave anodic stripping voltammetry. The currents at the peak potentials for Cd(II) and Pb(II) were used as the sensor signal for TC and CAP, respectively. This multiplex immunoassay enables the simultaneous determination of TC and CAP in a single run with dynamic ranges from 0.01 to 50 ng mL?1 for both analytes. The detection limits for TC and for CAP are 7.5 pg mL?1 and 5.4 pg mL?1, respectively. No obvious nonspecific adsorption and cross-reactivity was observed in a series of analyses. Intra-assay and inter-assay coefficients of variation were less than 10 %. The method was evaluated by analyzing TC and CAP in spiked samples of milk and honey. The recoveries range from 88 % to 107 % for TC, and from 91 % to 119 % for CAP.
Figure
We developed a new multiplexed electrochemical immunoassay for simultaneous determination of tetracycline and chloramphenicol, using metal sulfide nanoclusters as recognition elements.  相似文献   

5.
We report on a glassy carbon electrode (GCE) modified with a lead ionophore and multiwalled carbon nanotubes. It can be applied to square wave anodic stripping voltammetric determination of Pb(II) ion after preconcentration of Pb(II) at ?1.0?V (vs. SCE) for 300?s in pH?4.5 acetate buffer containing 400?μg?L?1 of Bi(III). The ionophore-MWCNTs film on the GCE possesses strong and highly selective affinity for Pb(II) as confirmed by quartz crystal microbalance experiments. Under the optimum conditions, a linear response was observed for Pb(II) ion in the range from 0.3 to 50?μg?L?1. The limit of detection (at S/N?=?3) is 0.1?μg?L?1. The method was applied to the determination of Pb(II) in water samples with acceptable recovery.
Figure
A glassy carbon electrode modified with a lead ionophore and multiwalled carbon nanotubes is successfully applied to sensitive and selective square wave anodic stripping voltammetric determination of Pb(II) ion after preconcentration of Pb(II) at ?1.0?V (vs. SCE) in pH?4.5 solutions containing 400?μg?L?1 of Bi(III).  相似文献   

6.
A new composite electrode is described for anodic stripping voltammetry determination of Pb(II) at trace level in aqueous solution. The electrode is based on the use of multiwalled carbon nanotubes and Amberlite IR-120. The anodic stripping voltammograms depend, to a large extent, on the composition of the modified electrode and the preconcentration conditions. Under optimum conditions, the anodic peak current at around ?0.57 V is linearly related to the concentration of Pb(II) in the range from 9.6?×?10?8 to 1.7?×?10?6 mol L?1 (R?=?0.998). The detection limit is 2.1?×?10?8 mol L?1, and the relative standard deviation (RSD) at 0.24?×?10?6 mol L?1 is 1.7% (n?=?6). The modified electrode was applied to the determination of Pb(II) using the standard addition method; the results showed average relative recoveries of 95% for the samples analysed.
Figure
A new composite electrode is described for anodic stripping voltammetry determination of Pb(II) at trace level in aqueous solution. The electrode is based on the use of MWCNT and Amberlite IR-120. The method showed a good linearity for 9.6?×?10?8 - 1.7?×?10?6 mol L?1 and detection limit of 2.1?×?10?8 mol L?1.  相似文献   

7.
Various carbon nanomaterials for use in anodic stripping voltammetric analysis of Hg(II), Cu(II), Pb(II) and Cd(II) are screened. Graphene, carbon nanotubes, carbon nanofibers and fullerene (C60), dispersed in chitosan (Chit) aqueous solution, are used to modify a glassy carbon electrode (GCE). The fullerene-chitosan modified GCE (C60-Chit/GCE) displays superior performance in terms of simultaneous determination of the above ions. The electrodes and materials are characterized by electrochemical impedance spectroscopy, cyclic voltammetry, scanning electron microscopy, Raman spectroscopy, X-ray diffraction and X-ray photoelectron spectroscopy. The excellent performance of C60-Chit/GCE is attributed to the good electrical conductivity, large surface area, strong adsorption affinity and unique crystalline structure of C60. Using differential pulse anodic stripping voltammetry, the assay has the following features for Hg(II), Cu(II), Pb(II) and Cd(II), respectively: (a) Peak voltages of +0.14, ?0.11, ?0.58 and???0.82 V (vs SCE); (b) linear ranges extending from 0.01–6.0 μM, 0.05–6.0 μM, 0.005–6.0 μM and 0.5–9.0 μM; and (c), detection limits (3σ method) of 3 nM (0.6 ppb), 14 nM (0.9 ppb), 1 nM (0.2 ppb) and 21 nM (2.4 ppb). Moreover, the modified GCE is well reproducible and suitable for long-term usage. The method was successfully applied to the simultaneous determination of these ions in spiked foodstuff.
Graphical abstract Compared with graphene, carbon nanotubes and carbon nanofibers, an electrode modified with fullerene in chitosan electrode displays superior performance for the simultaneous anodic stripping voltammetric detection of Hg(II), Cu(II), Pb(II) and Cd(II).
  相似文献   

8.
We report that magnetic multiwalled carbon nanotubes functionalized with 8-aminoquinoline can be applied to the preconcentration of Cd(II), Pb(II) and Ni(II) ions. The parameters affecting preconcentration were optimized by a Box-Behnken design through response surface methodology. Three variables (extraction time, magnetic sorbent amount, and pH value) were selected as the main factors affecting sorption, and four variables (type, volume and concentration of the eluent; elution time) were selected for optimizing elution. Following sorption and elution, the ions were quantified by FAAS. The LODs are 0.09, 0.72, and 1.0 ng mL?1 for Cd(II), Ni(II), and Pb(II) ions, respectively. The relative standard deviations are <5.1 % for five separate batch determinations at 30 ng mL?1 level of Cd(II), Ni(II), and Pb(II) ions. The sorption capacities (in mg g?1) of this new sorbent are 201 for Cd(II), 150 for Pb(II), and 172 Ni(II). The composite was successfully applied to the rapid extraction of trace quantities of heavy metal ions in fish, sediment, soil, and water samples.
Figure
A schematic diagram for synthesis of functionalized magnetic multiwalled carbon nanotube.  相似文献   

9.
We describe a novel magnetic metal-organic framework (MOF) prepared from dithizone-modified Fe3O4 nanoparticles and a copper-(benzene-1,3,5-tricarboxylate) MOF and its use in the preconcentration of Cd(II), Pb(II), Ni(II), and Zn(II) ions. The parameters affecting preconcentration were optimized by a Box-Behnken design through response surface methodology. Three variables (extraction time, amount of the magnetic sorbent, and pH value) were selected as the main factors affecting adsorption, while four variables (type, volume and concentration of the eluent; desorption time) were selected for desorption in the optimization study. Following preconcentration and elution, the ions were quantified by FAAS. The limits of detection are 0.12, 0.39, 0.98, and 1.2 ng mL?1 for Cd(II), Zn(II), Ni(II), and Pb(II) ions, respectively. The relative standard deviations were <4.5 % for five separate batch determinations of 50 ng mL?1 of Cd(II), Zn(II), Ni(II), and Pb(II) ions. The adsorption capacities (in mg g?1) of this new MOF are 188 for Cd(II), 104 for Pb(II), 98 Ni(II), and 206 for Zn(II). The magnetic MOF nanocomposite has a higher capacity than the Fe3O4/dithizone conjugate. This magnetic MOF nanocomposite was successfully applied to the rapid extraction of trace quantities of heavy metal ions in fish, sediment, soil, and water samples.
Figure
A schematic diagram for synthesis of magnetic MOF-DHz nanocomposite.  相似文献   

10.
Li Qi  Yan Shang  Fangying Wu 《Mikrochimica acta》2012,178(1-2):221-227
We report on a colorimetric probe for the determination of Pb(II). It is based on the use of silver nanoparticles that have been functionalizd with iminodiacetic acid (IDA-Ag NPs). The absorption spectrum and solution color of IDA-Ag NPs undergo dramatic changes on exposure to Pb(II) with a new absorption peak appearing at 650 nm and a concomitant color change from yellow to green. This is assumed to result from the aggregation of IDA-Ag NPs induced by Pb(II). Under optimum conditions, there is a linear relationship between the ratio of the absorbances at 650 and 396 nm, respectively, and the concentration of Pb(II) in the 0.4 to 8.0 μM concentration range, with a detection limit of 13 nM. The method was applied to the determination of Pb(II) in tap water and urea samples, and recoveries ranged from 93.7 % to 98.6 %.
Figure
A colorimetric probe based on iminodiacetic acid-functionalized silver nanoparticles (IDA-Ag NPs) was obtained and used for determination of Pb2+. The color change from yellow to green was assumed to result from the aggregation of the NPs induced by Pb(II) ions. The assay was possessed highly selectivity to lead(II) over the other ions.  相似文献   

11.
We report on the application of emulsification-based dispersive liquid microextraction (EB-DLME) to the preconcentration of Cd(II). This procedure not only possesses all the advantages of routine DLLME, but also results in a more stable cloudy state which is particularly useful when coupling it to FAAS. In EB-DLME, appropriate amounts of the extraction solvent (a solution of dithizone in chloroform) and an aqueous solution of sodium dodecyl sulfate (SDS; acting as a disperser) are injected into the samples. A stable cloudy microemulsion is formed and Cd(II) ion is extracted by chelation. After phase separation, the sedimented phase is subjected to FAAS. Under optimized conditions, the calibration curve for Cd(II) is linear in the range from 0.1 to 25 μg L?1, the limit of detection (at S/N?=?3) is 30 pg L?1, the relative standard deviations for seven replicate analyses (at 0.56 μg L?1 of Cd(II)) is 4.6 %, and the enrichment factor is 151. EB-DLME in our opinion is a simple, efficient and rapid method for the preconcentration of Cd(II) (and most likely of many other ions) prior to FAAS determination.
Figure
Emulsification based dispersive liquid microextraction is presented for determination of cadmium in water samples  相似文献   

12.
In this study, we demonstrated a highly sensitive electrochemical sensor for the simultaneous detection of Pb (II) and Cd (II) in aqueous solution using carbon paste electrode modified with Eichhornia crassipes powder by square wave anodic stripping voltammetry. The effect of modifier composition, pH, preconcentration time, reduction potential and time, and type of supporting electrolyte on the determination of metal ions were investigated. Pre-concentration on the modified surface was performed at open circuit. The modified electrode exhibited well-defined and separate stripping peaks for Pb (II) and Cd (II). Under optimum experimental conditions, a linear range for both metal ions was from 10 to 5000 μg L?1 with the detection limits of 4.9 μg L?1, 2.1 μg L?1 for Cd(II) and Pb (II), respectively. The modified electrode was found to be sensitive and selective when applied to determine trace amounts of Cd (II) and Pb (II) in natural water samples.  相似文献   

13.
Voltammetric procedures for trace metals analysis in polluted natural waters using homemade bare gold-disk microelectrodes of 25- and 125-μm diameters have been determined. In filtered seawater samples, square wave anodic stripping voltammetry (SWASV) with a frequency of 25 Hz is applied for analysis, whereas in unfiltered contaminated river samples, differential pulse anodic stripping voltammetry (DPASV) gave more reliable results. The peak potentials of the determined trace metals are shifted to more positive values compared to mercury drop or mercury-coated electrodes, with Zn always displaying 2 peaks, and Pb and Cd inversing their positions. For a deposition step of 120 s at ?1.1 V, without stirring, the 25-μm gold-disk microelectrode has a linear response for Cd, Cu, Mn, Pb and Zn from 0.2 μg L?1 (1 μg L?1 for Mn) to 20 μg L?1 (30 μg L?1 for Zn, Pb and 80 μg L?1 for Mn). Under the same analytical conditions, the 125-μm gold-disk microelectrode shows linear behaviour for Cd, Cu, Pb and Zn from 1 μg L?1 (5 μg L?1 for Cd) to 100 μg L?1 (200 μg L?1 for Pb). The sensitivity of the 25-μm electrode varied for different analytes from 0.23 (±0.5%, Mn) to 4.83 (±0.9%, Pb) nA L μmol?1, and sensitivity of the 125-μm electrode varied from 1.48 (±0.7%, Zn) to 58.53 (±1.1%, Pb  nA L μmol?1. These microelectrodes have been validated for natural sample analysis by use in an on-site system to monitor Cu, Pb and Zn labile concentrations in the Deûle River (France), polluted by industrial activities. First results obtained on sediment core issued from the same location have shown the ability of this type of microelectrode for in situ measurements of Pb and Mn concentrations in anoxic sediments.   相似文献   

14.
Polyimide (PI) sheets were laser etched to obtain graphene-based carbon nanomaterials (LEGCNs). These were analyzed by scanning electron microscopy, X-ray diffraction and Raman spectroscopy which confirmed the presence of stacked multilayer graphene nanosheets. Their large specific surface and large number of edge-plane active sites facilitate the accumulation of metal ions. A glassy carbon electrode (GCE) with an in-situ plated bismuth film was modified with the LEGCNs to give a sensor with satisfactory response for the simultaneous determination of cadmium(II) and lead(II) by means of square wave anodic stripping voltammetry. It appears that is the first report on an electrochemical sensor based on the use of laser etched graphene for determination of heavy metal ions. Figures of merit for detection of Cd(II) include (a) a low and well separated working potential of ?0.80 V (vs. Ag/AgCl), (b) a wide linear range (from 7 to 120 μg·L?1), and a low detection limits 0.47 μg·L?1. The respective data for Pb(II) are (a) -0.55 V, (b) 5 to 120 μg·L?1, and (c) 0.41 μg·L?1. The modified GCE displays remarkable repeatability, reproducibility, selectivity and stability. The sensor was applied to the simultaneous determination of Cd(II) and Pb(II) in spiked real water samples. The results confirm that the laser etching technique is an efficient tool for the preparation of carbon nanomaterials with high quality and great sensing performance.
Graphical abstract Bismuth film and laser etched graphene-modified glassy carbon electrode (BF-LEGCN/GCE) for the simultaneous determination of cadmium(II) and lead(II) by square wave anodic stripping voltammetry.
  相似文献   

15.
We have constructed a carbon nitride electrode modified with a bismuth film and show that it can be used for the electroanalysis of lead(II) by differential pulse anodic stripping voltammetry. The combination of such materials is shown to greatly improve the sensing capability of the electrode. Under the optimal conditions, the electrochemical response of the modified electrode is linearly related to the concentration of Pb(II) in the 6 – 1,000 nM concentration range (R = 0.9983). The detection limit is 2.0 pM (at an SNR of 3), and the sensitivity is 8 times better of that of respective graphite electrodes. The sensor enables rapid, highly sensitive, continuous, and environmentally friendly determination of trace levels of Pb(II) at affordable costs.
Figure
Graphite-like carbon nitride (g-C3N4) as a new electrode material shows high performance for the determination of Pb(II).  相似文献   

16.
We describe the application of temperature-controlled ionic liquid based microextraction (TC-IL-ME) of lead(II) ion. The method does not require the use of an organic solvent or a ligand. Rather, the IL is directly added to the aqueous sample containing Pb(II) in a centrifuge tube, and the mixture is heated to 80 °C for 4 min. After cooling at 0 °C, the solution turns cludy due to the formation of fine droplets of the IL containing Pb(II). The IL is separated by centrifugation, acidified, and directly submitted to FAAS by microinjection. The effects of pH value, volume of IL, extraction time, temperature, sample volume and matrix were optimized to result in a preconcentration factor of 30, a detection limit of 5.8 μg L?1, and a limit of quantification of 19.3 μg L?1. The method was validated by analyzing a certified reference material (NCSZC81002B; hair). A recovery test performed with spiked samples gave values between 102 % and 105 %. The method was also used to determine Pb(II) in hair samples.
Figure
We describe the application of temperature-controlled ionic liquid based microextraction (TC-IL-ME) of lead(II) ion. The effects of pH value, volume of IL, extraction time, temperature, sample volume and matrix were optimized.  相似文献   

17.
Disposable screen-printed carbon arrays modified with gold nanoparticles (AuNPs) are described. The AuNP-modified screen-printed carbon arrays, designated as AuNP-SPCE arrays, were characterized by cyclic voltammetry and electrochemical impedance spectroscopy. The AuNP-SPCE arrays display excellent electrocatalytic activity towards lead and copper. Two well-defined and fully resolved anodic stripping peaks, at 20 mV for Pb(II) and at 370 mV for Cu(II), both vs. Ag/AgCl, can be seen. Square wave anodic stripping voltammetry was used to simultaneously analyze Pb(II) and Cu(II) in their binary mixtures in tap water. The linear working range for Pb(II) extends from 10 μg.L?1 to 100 μg.L?1 with a sensitivity of 5.94 μA.μg?1.L.cm?2. The respective data for Cu(II) are a working range from 10 μg.L?1 to 150 μg.L?1 with a sensitivity of 3.52 μA.μg?1.L.cm?2. The limits of detection (based on 3× the baseline noise) are 2.1 ng.L?1 and 1.4 ng.L?1, respectively. In our perception, this array is particularly attractive because Pb(II) and Cu(II) can be determined at rather low working potentials which makes the method fairly selective in that it is not significantly interfered by other electroactive species that require higher reduction potentials.
Graphical abstract Fabrication, characterization and electrochemical behavior of gold nanoparticles modified screen-printed carbon arrays towards lead and copper in tap water.
  相似文献   

18.
We have developed a method for the microextraction of lead(II) ion. It is based on the use of suspended zirconia nanoparticles modified with the reagent cadion. Pb(II) ions in the sample are adsorbed onto the modified zirconia nanoparticles suspended in the solution of a non-ionic surfactant. After cloud formation and phase separation by sedimentation, the surfactant rich phase was acidified and diluted to 100 μL with 3.0 mol L?1 nitric acid and ultrasonicated for a few seconds to desorb the analyte from the sorbent. The mixture was centrifuged and 10 μL of the supernatant liquid phase along with 10 μL of the Pd/Mg modifier were submitted to the electrothermal atomic absorption spectrometer. The parameters affecting the extraction efficiency were optimized by the univariable method. Under the optimized conditions, a sample volume of 40 mL resulted in an enhancement factor of 384 and a detection limit (defined as 3Sb/m) of 2.2 ng L?1. The method was successfully applied to the determination of Pb(II) in water, tea and rice samples. Accuracy was determined by the recovery experiments and the analysis of two certified reference materials.
Figure
A new microextraction method for lead (II) is developed. It is based on the use of suspended zirconia nanoparticles modified with the reagent cadion. The method was successfully applied to the determination of the Pb(II) in water, tea and rice samples. Accuracy was determined by the recovery experiments and the analysis of two certified reference materials.  相似文献   

19.
We have designed and synthesized a thermosensitive tri-block copolymer for selective trace extraction of Pb(II) ions from biological and food samples. The polymer was characterized by Fourier transform IR and NMR spectroscopy, and by gel permeation chromatography. The critical aggregation concentration and lower critical solution temperature were determined via fluorescence and UV spectrophotometry, respectively. The effects of solution pH value, amount of copolymer, of the temperature on extraction and on phase separation, and of the matrix on the extraction of Pb(II) were optimized. Pb(II) ions were then quantified by FAAS. The use of this copolymer resulted in excellent figures of merit including a calibration plot extending from 0.5 to 160 μg L?1 (with an R2 of >0.99), a limit of detection (LOD) as low as 90 pg L?1, an extraction efficiency of >98 %, and relative standard deviations of <4 % for eight separate extraction experiments.
Figure
In this paper, for the first time an intelligent system using a thermosensitive tri-block copolymer for selective trace removal of Pb(II) in biological and food samples was designed and its determination was carried out by flame atomic absorption spectrometry.  相似文献   

20.
The present work describes a study of complexation efficiency and selectivity of calix[4]arenes bearing benzoimidazolyl, benzothiazolyl, and benzoxazolyl heterocycles (57) towards several selected metal ions using fluorescence and UV–Vis spectroscopy. The binding ability of calixarene derivatives 57 toward selected divalent metal ions such as Ca, Cd, Pb, Ni, Mg, Mn, Co, Fe and Zn has been investigated by fluorescence spectroscopic techniques. Fluorescent chemosensor ability of three calixarene derivatives was highly selective for Pb (II) in contrast with other divalent metal studied. The highest association constant corresponds to benzoxazolyl calixarene derivative 7, with a Ka of (1.37 ± 0.06) × 104 mol?1 L and detection limit for lead of 1.14 ± 0.05 mg L?1 in methanol being acceptable for the recognition of this metal at micromolar concentrations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号