首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In electrospray ionization (ESI)-ion mobility spectrometry, continuously generated ions must be desolvated in a first tube before short ion pulses are introduced into a second (drift) tube. Both tubes are separated by an ion-gate. The resolving power of the resulting drift time spectrum is strongly influenced by the design of the ion gate. In the case of the Bradbury-Nielsen gates typically used, an orthogonal field between oppositely charged, parallel wires blocks ions from entering the drift tube. However, the blocking field also distorts the entering ion cloud. One alternative, which eliminates these effects and therefore enables a potentially higher resolving power, is already known for spectrometers with small ionization volumes, where ions are formed between two electrodes and subsequently transferred into the drift tube by a high voltage pulse. Based on this setup, we introduce an alternative ion gate design for liquid samples, named field switching ion gate (FSIG). The continuous flow of ions generated by ESI is desolvated in the first tube and introduced into the space between two electrodes (repeller and transfer electrodes). A third (blocking) electrode prevents the movement of ions into the drift tube in the closed state. Ions are transferred during the open state by pulsing the voltages of the repeller and blocking electrodes. First results demonstrate an increase of the resolving power by 100% without intensity losses and further changes in the spectrometer setup. The parameters of the FSIG, such as electrode voltages and pulse width, are characterized allowing the optimization of the spectrometer’s resolving power.  相似文献   

2.
An ion mobility spectrometer that can easily be installed as an intermediate component between a commercial triple-quadrupole mass spectrometer and its original atmospheric pressure ionization (API) sources was developed. The curtain gas from the mass spectrometer is also used as the ion mobility spectrometer drift gas. The design of the ion mobility spectrometer allows reasonably fast installation (about 1 h), and thus the ion mobility spectrometer can be considered as an accessory of the mass spectrometer. The ion mobility spectrometer module can also be used as an independently operated device when equipped with a Faraday cup detector. The drift tube of the ion mobility spectrometer module consists of inlet, desolvation, drift, and extraction regions. The desolvation, drift and extraction regions are separated by ion gates. The inlet region has the shape of a stainless steel cup equipped with a small orifice. Ion mobility spectrometer drift gas is introduced through a curtain gas line from an original flange of the mass spectrometer. After passing through the drift tube, the drift gas serves as a curtain gas for the ion-sampling orifice of the ion mobility spectrometer before entering the ion source. Counterflow of the drift gas improves evaporation of the solvent from the electrosprayed sample. Drift gas is pumped away from the ion source through the original exhaust orifice of the ion source. Initial characterization of the ion mobility spectrometer device includes determination of resolving power values for a selected set of test compounds, separation of a simple mixture, and comparison of the sensitivity of the electrospray ionization ion mobility spectrometry/mass spectrometry (ESI-IMS/MS) mode with that of the ESI-MS mode. A resolving power of 80 was measured for 2,6-di-tert-butylpyridine in a 333 V/cm drift field at room temperature and with a 0.2 ms ion gate opening time. The resolving power was shown to be dependent on drift gas flow rate for all studied ion gate opening times. Resolving power improved as the drift gas flow increased, e.g. at a 0.5 ms gate opening time, a resolving power of 31 was obtained with a 0.65 L/min flow rate and 47 with a 1.3 L/min flow rate for tetrabutylammonium iodide. The measured limits of detection with ESI-MS and with ESI-IMS/MS modes were similar, demonstrating that signal losses in the IMS device are minimal when it is operated in a continuous flow mode. Based on these preliminary results, the IMS/MS instrument is anticipated to have potential for fast screening analysis that can be applied, for example, in environmental and drug analysis.  相似文献   

3.
The use of radio-frequency (RF)-only ion guides for efficient transport of ions through regions of a mass spectrometer where the background gas pressure is relatively high is widespread in present instrumentation. Whilst multiple collisions between ions and the background gas can be beneficial, for example in inducing fragmentation and/or decreasing the spread in ion energies, the resultant reduction of ion axial velocity can be detrimental in modes of operation where a rapidly changing influx of ions to the gas-filled ion guide needs to be reproduced at the exit. In general, the RF-only ion guides presently in use are based on multipole rod sets. Here we report investigations into a new mode of ion propulsion within an RF ion guide based on a stack of ring electrodes. Ion propulsion is produced by superimposing a voltage pulse on the confining RF of an electrode and then moving the pulse to an adjacent electrode and so on along the guide to provide a travelling voltage wave on which the ions can surf. Through appropriate choice of the travelling wave pulse height, velocity and gas pressure it will be shown that the stacked ring ion guide with the travelling wave is effective as a collision cell in a tandem mass spectrometer where fast mass scanning or switching is required, as an ion mobility separator at pressures around 0.2 mbar, as an ion delivery device for enhancement of duty cycle on an orthogonal acceleration time-of-flight (oa-TOF) mass analyser, and as an ion fragmentation device at higher wave velocities.  相似文献   

4.
A key component in the design of every drift tube ion mobility spectrometer (IMS) is the ion shutter which controls the injection of ions into the drift tube. Especially, compact drift tube IMS require very short injection pulses to achieve high resolution and therefore require fast ion shutters. Thus, it is important to find an ion shutter principle that can be readily scaled towards these short injection widths without causing major non-idealities in the injection process, such as drift field inhomogeneities, ion loss and ion discrimination by mobility. In this paper, we compare different ion shutter principles, foremost the Bradbury-Nielsen gate and a field switching design. It is shown through theoretical considerations and field simulations that the Bradbury-Nielsen shutter is more universally applicable and typically less complex for long injections widths but field inhomogeneities associated with its operating principle impede the scaling process. Thus, the currently less used field switching shutters will become the superior principle when very short injection widths are required, as this shutter principle allows for single digit microsecond widths.  相似文献   

5.
We present a detailed investigation of the performance of our previously reported nanoelectrospray high‐resolution resistive‐glass atmospheric pressure drift tube ion mobility spectrometer constructed with monolithic resistive‐glass desolvation and drift regions. Using experimental spectral data and theoretical pulse width and diffusion variables, we compare theoretical and experimental resolving powers achievable under a variety of field strengths and ion gate pulse widths. The effects of instrumental and operational parameters on the resolution achievable in chromatographic terms are also discussed. Following characterization of the separation power of the instrument, experimental spectral peak width data is fitted by a least‐squares procedure to a pre‐existing semi‐empirical model developed to study contributions to peak width other than initial pulse width and diffusional broadening. The model suggests possible contributions to the final measured peak width from electric field inhomogeneity and minor contributions from instrumental parameters such as anode size, anode‐to‐anode grid distance and drift gas flow rate. The model also reveals an unexpected ion gate width dependence on the final measured peak width that we attribute to non‐ideal performance of the Bradbury‐Nielsen ion gate and limitations in the design of our pulsing‐electronics. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

6.
代渐雄  段忆翔 《分析化学》2016,(11):1686-1691
离子迁移谱仪的性能受到多种因素的影响,如漂移管电场强度离子门脉冲宽度、离子源工作条件、漂移管尺寸、离子门加工工艺和屏蔽网透过率等。在实际应用中需要对漂移管电场强度和离子门脉冲宽度进行调整以平衡灵敏度和分辨率。本研究详细研究了漂移管电场强度和离子门脉冲宽度对微波诱导等离子体离子迁移谱( MIPI-IMS)分辨率和灵敏度的影响。实验结果表明,存在一个最佳电场强度值使得分辨率达到最大,而且不同离子门脉冲宽度对应的最佳电场强度值不同;增大电场强度和离子门脉冲宽度有利于灵敏度的提升。与其它离子流较弱的离子源相比,离子流较大的微波诱导等离子体离子源在实际应用中对离子门脉冲宽度和漂移管电场强度有更多的选择。此研究结果有助于MIPI-IMS仪器性能的提升。将异丙醇用于测试MIPI-IMS的性能,结果表明,MIPI-IMS在保持较低检出限(7.7×10-11, V/V)的同时,分辨率可以达到66。  相似文献   

7.
The effect of space charge on the ion beam in a spectrometer of ion mobility increment with the planar drift chamber has been investigated. A model for the drift of ions under a non-uniform high-frequency electric field(1-3) has been developed recently. We have amplified this model by taking space charge effect into account. The ion peak shape taking into consideration the space charge effect is obtained. The output current saturation effect limiting the rise of the ion peak with increasing ion density at the input of the drift chamber of a spectrometer is observed. We show that the saturation effect is caused by the following phenomenon. The maximum possible output ion density exists, depending on the ion type (constant ion mobility, k(0)) and the time of the motion of ions through the drift chamber. At the same time, the ion density does not depend on the parameters of the drift chamber.  相似文献   

8.
This paper explains the effect of pressure on separation factor, resolving power (defined based on a single peak), and resolution (defined based on two adjacent peaks) in ion mobility spectrometry. IMS spectra were recorded at various pressures ranging from 39 hPa (29 Torr) up to atmospheric pressure and various ion gates ranging from 50 to 225 μs. The results show that the IMS peaks shift perfectly linear with pressure so that separation factors remain unaffected by pressure. However, pressure has strong influence on resolving power and resolution. Reducing pressure at constant pulse width decreases the resolving power and resolution. On the other hand, the decrease in resolution can be compensated by shortening the ion pulse width since reducing pressure results in a higher ion current.  相似文献   

9.
Hill CA  Thomas CL 《The Analyst》2005,130(8):1155-1161
The concept of using a short ionisation event, in this case a pulsed corona discharge, in conjunction with programmed gate delay is described. This technique is proposed for the selective study of different ionisation processes within the reaction region of an ion mobility spectrometer. The utility of such an approach was tested in a study of the ionisation of dipropylene-glycol-monomethyl-ether (DPM); a compound commonly used to test the operation of ion mobility spectrometers. Dipropylene-glycol-monomethyl-ether at a concentration of 113 microg m(-3) in air, with a water level of 75 mg m(-3) in air, was analysed using a switchable, high resolution ion mobility spectrometer, operating in the positive mode at 40 degrees C at ambient pressure. The ion mobility spectrometer was fitted with a pulsed corona discharge ionisation source, doped with ammonia at a concentration of 1.3 mg m(-3) in the reaction region, and interfaced to a mass spectrometer. Synchronisation of the ionisation event to the operation of the shutter grids for the drift region enabled different parts of the product ion population to be injected into the drift tube, and programming the gate delays produced a map of the gate delay verses drift time response surface. Ammonium bound dipropylene-glycol-monomethyl-ether was observed, [(DPM)NH4]+ (m/z 166) as well as the ammonium bound dimer [(DPM)2NH4]+ (m/z 314), the same as those observed with a 63Ni source. Two other species were also observed, but their molecular identity was not elucidated. One of them m/z 146, also observed with 63Ni, formed ammonium bound ions [(m/z 146)NH4]+ (K0= 1.49 cm2 V(-1) s(-1)), ammonium bound dimer ions [(m/z 146)2NH4]+(K0= 1.18 cm2 V(-1) s(-1)) and a mixed cluster ion with DPM [(m/z 146)(DPM)NH4]+(K0= 1.18 cm2 V(-1) s(-1)); while the other, m/z 88 a decomposition product, formed ammonium bound monomer [(m/z 88)NH4]+(K0= 1.68 cm2 V(-1) s(-1)), dimer ions [(m/z 88)2NH4]+(K0= 1.40 cm2 V(-1) s(-1)) and a mixed cluster ion containing DPM and ammonium, [(DPM)(m/z 88)2NH4]+(K0= 1.40 cm2 V(-1) s(-1)). The assignment of responses to these ions required the additional dimensionality in the data provided from the gate delay studies. The relationships evident in the programmable gate delay data enabled these ions to be differentiated from alternative assignments of possible nitrogen clusters, formed at the interface of the mass spectrometer.  相似文献   

10.
Current commercially available ion mobility spectrometers are intended for the analysis of chemicals in the gas phase. Sample introduction methods, such as direct air sampling, a GC injector or a thermal desorber, are commonly an integral part of these instruments. This paper describes an electrospray ionization ion mobility spectrometer system that allows direct introduction samples in solution phase. This allows direct analysis of non-volatile organic and biological samples, and avoids decomposition of thermally liable samples, providing reliable chemical identification. In addition, the new ion mobility spectrometer allows mobility analysis with high resolving power. Commonly used commercial IMS systems provide resolving powers between 10 and 30; this new ion mobility spectrometer has resolving power greater than 60 for routine analysis. A high resolution instrument is necessary for many applications where a complex mixture needs to be separated and quantified. This paper demonstrates the advantages of using a high resolution ion mobility spectrometer and an electrospray ionization source for the analysis of non-volatile pharmaceuticals as well as dissolved explosive in solution phase.  相似文献   

11.
A nano-electrospray ionisation source has been designed and constructed for a high temperature ion mobility spectrometer. The drift cell was modified by replacement of the 63Ni atmospheric pressure chemical ionisation source with a tube lens/desolvation region and operated using commercial nano-electrospray capillaries. Ions were introduced into the drift region via a Bradbury-Nielson gate (pulse width 50 micros, repetition period 20 ms). A unidirectional flow of nitrogen was used as the drift gas at temperatures in the range 100-150 degrees C to aid desolvation. The performance of the nano-electrospray ion source has been demonstrated for analytes including crown ethers, amino acids and peptides. Reduced mobilities determined by nano-ESI were consistent with those reported using a 63Ni ion source.  相似文献   

12.
Excluding the ion source, an ion mobility spectrometer is fundamentally comprised of drift chamber, ion gate, pulsing electronics, and a mechanism for amplifying and recording ion signals. Historically, the solutions to each of these challenges have been custom and rarely replicated exactly. For the IMS research community few detailed resources exist that explicitly detail the construction and operation of ion mobility systems. In an effort to address this knowledge gap we outline a solution to one of the key aspects of a drift tube ion mobility system, the ion gate pulser. Bradbury-Nielsen or Tyndall ion gates are found in nearly every research-grade and commercial IMS system. While conceptually simple, these gate structures often require custom, high-voltage, floating electronics. In this report we detail the operation and performance characteristics of a wifi-enabled, MOSFET-based pulser design that uses a lithium-polymer battery and does not require high voltage isolation transformers. Currently, each output of this circuit follows a TTL signal with ~20 ns rise and fall times, pulses up to +/? 200 V, and is entirely isolated using fiber optics. Detailed schematics and source code are provided to enable continued use of robust pulsing electronics that ease experimental efforts for future comparison.  相似文献   

13.
M.T. Jafari 《Talanta》2009,77(5):1632-1639
An improved design for high resolution electrospray ionization ion mobility spectrometry (ESI-IMS) was developed by making some salient modifications to the IMS cell and its performance was investigated. To enhance desolvation of electrospray droplets at high sample flow rates in this new design, volume of the desolvation region was decreased by reducing its diameter and the entrance position of the desolvation gas was shifted to the end of the desolvation region (near the ion gate). In addition, the ESI source (both needle and counter electrode) was positioned outside of the heating oven of the IMS. This modification made it possible to use the instrument at higher temperatures, and preventing needle clogging in the electrospray process. The ion mobility spectra of different chemical compounds were obtained. The resolving power and resolution of the instrument were increased by about 15-30% relative to previous design. In this work, the baseline separation of the two adjacent ion peaks of morphine and those of codeine was achieved for the first time with resolutions of 1.5 and 1.3, respectively. These four ion peaks were well separated from each other using carbon dioxide (CO2) rather than nitrogen as the drift gas. Finally, the analytical parameters obtained for ethion, metalaxyl, and tributylamine indicated the high performance of the instrument for quantitative analysis.  相似文献   

14.
An ion mobility cell of a novel type was coupled to an orthogonal injection time-of-flight (TOF) mass spectrometer. The mobility cell operates at low-pressure and contains a segmented RF ion guide providing an axial electric field that drives the ions towards the exit. A flow of gas is arranged inside the ion guide in such a way that the gas drag counteracts the force exerted by the axial field. Ions with different mobility coefficients can be scanned out of the ion guide by ramping the axial field strength. The ions can be analyzed intact or fragmented in a collision cell before introduction into an orthogonal TOF mass spectrometer. An ion source with matrix assisted laser desorption/ionization (MALDI) was attached to the instrument. The setup was evaluated for the analysis of peptide and protein mixture, with sequential fragmentation of multiple precursor ions from a protein digest and with mobility separation of fragment ions formed by in-source fragmentation of pure peptides. The mobility resolution for peptides was observed to be three times higher than the theoretical resolution predicted for a classical mobility setup with similar operating conditions (pressure, field strength, and length).  相似文献   

15.
Ion mobility-mass spectrometry is starting to be considered as a useful tool in the deconvolution of complex oil and petroleum samples. While ultrahigh resolution mass spectrometry is the incumbent technology in this field, ion mobility offers complementary information related to species size and shape, and also the ability to resolve structural isomers. In this work, a sample of the resins portion of the Saturates, Aromatics, Resins, and Asphaltenes (SARA) fractions of crude oil was analysed using an orthogonal acceleration quadrupole time-of-flight mass spectrometer (oa-QToF MS) that incorporates a travelling wave ion mobility spectrometry (TWIMS) region. The ion mobility data were compared with previously acquired ultrahigh resolution Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) data and various nitrogen containing families were identified. Ion mobility data were processed in the typical way for the oil and petroleum industry; and the use of high resolution exact mass coupled with mobility data to provide enhanced species resolution was examined. Double bond equivalence (DBE) and carbon number groups were identified using patterns in the ion mobility data, which demonstrated the utility of ion mobility for discovering species relationships within the crude oil sample. The ability to calibrate the ion mobility cell and generate sizes for the detected ions was also recognised as potentially having particular value for the implementation of conversion or hydrotreatment processes in the oil industry.  相似文献   

16.
The time‐dependent reacceleration of product ions produced as a result of dissociation of a single precursor ion in a tandem time‐of‐flight mass spectrometer is considered for the first time. Analytical expressions for the shapes of electric pulses bringing all the kinetic energies of the product ions to the same value are derived for two cases: forward acceleration mode and deceleration, followed by re‐acceleration in the reversed direction (reversed mode). Secondary time‐of‐flight focusing resulting from the re‐acceleration in the reversed mode is shown to be mass‐dependent and, when averaged over a wide mass range, the focusing is tight enough to provide mass resolution exceeding 10 000. After time‐dependent re‐acceleration, additional compression of the ion packet width leading to better mass resolution can be obtained by decelerating the ions in a constant field. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

17.
A new miniaturized ion mobility spectrometer (microIMS) has been constructed and evaluated. The results obtained for a selected group of volatile organic compounds have been compared with those provided by an IMS of bigger dimensions with satisfactory conclusions. Moreover, its performance in terms of analytes resolution is better than those values given for other miniaturized instruments described in the literature. The possibility of an adjustable shutter opening time and the low intensity of the radiation source are also remarkable characteristics of the miniaturized detector. The small size of the microIMS enables its portability and its wide-range of applications as a sensor device. Six different substances supposed as respiratory markers of different diseases have been selected to prove the feasibility of the spectrometer constructed.  相似文献   

18.
Ion mobility spectrometry is a well-known method for fast trace gas detection. Detection limits in the very low ppb- and even ppt-range, fast response times down to a second and good separation power combined with a reasonable instrumental effort make ion mobility spectrometry more and more attractive. Aiming for higher separation power we investigate the ion specific lifetime of different ion species in a field free reaction region of a drift tube ion mobility spectrometer equipped with a pulsed non-radioactive electron gun. When turning off the electron gun ionization stops and the total ion concentration in the reaction region starts to decrease, while different ion species have different decay times. By varying the time delay between the end of the ionization and the injection pulse transferring all remaining ions of one polarity from the reaction region into the drift region the individual decay times can be measured. Our experimental data show that the lifetime of ion species in a field free reaction region mainly depends on ion-ion-recombination and charge transfer reactions leading to significant lifetime differences. Therefore, short-lived ions can be effectively suppressed in the reaction region by introducing a sufficient time delay between the end of the ionization and the injection pulse. This allows detecting even smallest concentrations of long-lived ions in a complex short-lived background. From our experimental data it can be also concluded that wall losses and the ion transport within the sample gas stream out of the reaction region just play a minor role in the ion loss.  相似文献   

19.
The use of ion mobility separation to determine the collision cross-section of a gas-phase ion can provide valuable structural information. The introduction of travelling-wave ion mobility within a quadrupole/time-of-flight mass spectrometer has afforded routine collision cross-section measurements to be performed on a range of ionic species differing in gas-phase size/structure and molecular weight at physiologically relevant concentrations. Herein we discuss the technical advances in the second-generation travelling-wave ion mobility separator, which result in up to a four-fold increase in mobility resolution. This improvement is demonstrated using two reverse peptides (mw 490 Da), small ruthenium-containing anticancer drugs (mw 427 Da), a cisplatin-modified protein (mw 8776 Da) and the noncovalent tetradecameric chaperone complex GroEL (mw 802 kDa). What is also shown are that the collision cross-sections determined using the second-generation mobility separator correlate well with the previous generation and theoretically derived values.  相似文献   

20.
An efficient ion transport system that interfaces external ion sources with a commercial dual-cell Fourier transform mass spectrometry (FTMS) system so as to retain maximum experimental flexibility has been constructed. Electrostatic lenses were used for ion transfer with potentials less than 200 V to preclude discharges. Spectra were recorded by thermal ionization and by electrospray ionization. Other high pressure ionization methods can be easily added to the external ion source chamber, making this a general solution for ion transport into an FTMS system. The efficiency of ion transfer was measured to be approximately 30%. A pressure ratio of 105 between the external ion source chamber and the second cell has been demonstrated. The system incorporates a computer-controlled gate valve to isolate the cell regions from the external ion source chamber, permitting optimal conditions for ion injection and accumulation, and then after closing the valve, recording spectra at low pressure with high resolution. Spectra of Gramicidin S (resolution 90,000 at m/z 1164), aprotinin (resolution 410,000 at m/z 1304), and horse heart cytochrome c (resolution 50,000 at m/z 1546) are shown.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号