首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《先进技术聚合物》2018,29(7):1930-1938
Low‐density polyethylene (LDPE) and polystyrene (PS) films with hydrophilic surface were prepared by photochemical grafting of sulfobetaine‐based copolymer containing photolabile moiety, and long‐term stability of the hydrophilic nature of the surfaces in seawater was proved. The sulfobetaine‐based copolymer was prepared by copolymerization of N,N‐dimethyl‐N‐(3‐(methacryloylamino)propyl)‐N‐(3‐sulfopropyl) ammonium betaine with 2 or 5 mol% of N‐methacryloyl‐4‐azidoaniline, and the resulted polymers were grafted onto the plasma pretreated LDPE and PS films. The contact angle measurements were used to prove the modification as well as to follow the changes in the hydrophilicity during storage at room temperature under air atmosphere as well as in seawater at 32°C. The stability of the polymer layer was confirmed also by FTIR and AFM. Polysulfobetaine‐modified LDPE and PS surfaces exhibited significantly higher long‐term hydrophilicity compared with only plasma treated LDPE and PS surfaces.  相似文献   

2.
The surface of low density polyethylene (LDPE) was modified by grafting a photoinitiator on it, after an Ar plasma treatment. The functionalisation was characterized by contact angle measurements, XPS analyses and AFM. The grafted LDPE was then coated with a UV-curable formulation based on highly fluorinated oligomers. Although the surface tension of the coating is very low, a good adhesion onto the substrate was obtained due to the surface treatment which was applied.  相似文献   

3.
The effect of argon, oxygen, and nitrogen plasma treatment of solvent cast EPDM rubber films has been investigated by means of atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS), and surface energy measurements. Plasma treatment leads to changes in the surface energy from 25 to 70 mN/m. Treatment conditions influenced both the changes in surface energy and the stability, and it became more difficult to obtain good contact angle measurements after longer (> ca. 4 min) treatment times, probably because of an increasingly uneven surface structure. XPS analyses revealed that up to 20 at. % oxygen can be easily incorporated and that variations of approximately 5% can be controlled by the plasma conditions. Oxygen was mainly found in hydroxyl groups, but also as carbonyl and carboxyl. XPS analyses showed more stable surfaces than expected from contact angles, probably because XPS analysis is less surface sensitive than contact angle measurements. AFM measurements revealed different surface structures with the three gases. The surface roughness increased generally with treatment time, and dramatic changes could be observed at longer times. At short times, surface energy changes were much faster than the changes in surface structure, showing that plasma treatment conditions can be utilized to tailor both surface energies and surface structure of EPDM rubber.  相似文献   

4.
A two‐step process based on a low‐pressure helium plasma treatment followed by acrylic acid‐grafting copolymerization was used for the surface modification of expanded polytetrafluoroethylene (ePTFE) films. The effects of plasma treatment power and treatment time on the hydrophilicity of the film surface were investigated. The wettability of the ePTFE film surface was characterized by water contact angle, and the surface compositions of the untreated and treated ePTFE samples were evaluated by atomic force microscopy and XPS. Contact angle measurements revealed that the hydrophilicity of the ePTFE film surface was greatly enhanced by the combined actions of the plasma treatment and acrylic acid grafting, and the contact angle decreased from 145° to 66°. Atomic force microscopy analyses showed that the surface roughness increased after the plasma treatment. XPS analyses showed substantial increase in the concentration of carbon and oxygen atoms and a decrease in the concentration of fluorine atoms at the film surface. T‐peel strength showed an improved bonding strength between the film and an adhesive tape after the treatment. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

5.
Surface modification with dielectric barrier discharge (DBD) plasma was carried out at atmospheric pressure (argon as the discharge gas) to improve the biocompatibility of hydrophobic acrylate intraocular lens (IOL). Changes of the plasma-treated IOL surface in chemical composition, morphology and hydrophilicity were comprehensively evaluated by X-ray photoelectron spectroscopy (XPS), field emission scanning electron microscopy (FESEM), atomic force microscopy (AFM) and water contact angle (WCA) measurements. The surface biocompatibility of the untreated and plasma-treated IOLs was compared with the adhesion behavior of platelets, macrophages and lens epithelial cells (LECs) in vitro. After DBD plasma treatment, the hydrophilicity of the IOL surface was obviously improved. The changes in WCA with treatment extension may be attributed to both the introduction of oxygen or/and nitrogen-containing polar groups and the increase of surface roughness induced by plasma etching effect. The existence of low molecular weight oxidized material (LMWOM) was proved on the plasmatreated IOL which was caused by the chain scission effect of the plasma treatment. The plasma-treated IOLs resisted the adhesion of platelets and macrophages significantly. The LECs spreading and proliferation were postponed on the IOLs plasma-treated for more than 180 s, with a well maintained epithelial phenotype of LECs. The IOL biocompatibility was improved after the DBD plasma treatment. We speculate that slighter foreign-body reaction and later incidence of anterior capsule opacification (ACO) may be expected after implantation of the argon DBD plasma-treated IOL. Supported by the Zhejiang Natural Science Foundation of China (Grant No. 2004C23003)  相似文献   

6.
A plasma treatment that renders asymmetric polysulfone membranes permanently hydrophilic is reported. Our modification strategy entails treating these membranes downstream from an inductively coupled rf plasma source. Contact angle measurements confirm that the membranes are completely wettable with water as a result of H2O plasma treatment. More importantly, the hydrophilic modification is permanent as plasma-treated membranes remain wettable for more than 16 months after plasma treatment. This treatment achieves the desired change in wettability for microporous as well as ultrafiltration polysulfone membranes, illustrating the universality of this method. XPS analysis of treated membranes demonstrates this dramatic change in wettability is a result of chemical changes in the membrane induced by plasma treatment. Moreover, the membrane modification is complete as the plasma penetrates the thickness of the membrane, thereby modifying the entire membrane cross-section.  相似文献   

7.
The surface modification of polyethylene (PE) by neutral nitrogen species (ground and excited state N2 as well as atomic N; modified nitrogen plasma treatment) has been compared to the effect of nitrogen ion bombardment using X-ray Photoelectron Spectroscopy (XPS) and contact angle measurements. XPS results indicate that a greater nitrogen concentration was grafted during the modified nitrogen plasma treatment of PE, an effect that was attributed to surface sputtering during ion beam modification. The distribution of nitrogen-containing functionalities was strongly dependent upon the treatment strategy; the modified nitrogen plasma treatment lead predominantly to imine groups being formed at the PE surface, while amine groups were the dominant species produced during ion beam modification. The presence of electron irradiation during the modified nitrogen plasma treatment of PE did not modify the rate of nitrogen incorporation or change the nature of N-containing functional groups produced but did lead to a systematic decrease in contact angle.  相似文献   

8.
In this paper, we present a study on the surface modification of polyethyleneterephthalate (PET) polymer by plasma treatment. The samples were treated by nitrogen and oxygen plasma for different time periods between 3 and 90 s. The plasma was created by a radio frequency (RF) generator. The gas pressure was fixed at 75 Pa and the discharge power was set to 200 W. The samples were treated in the glow region, where the electrons temperature was about 4 eV, the positive ions density was about 2 × 1015 m?3, and the neutral atom density was about 4 × 1021 m?3 for oxygen and 1 × 1021 m?3 for nitrogen. The changes in surface morphology were observed by using atomic force microscopy (AFM). Surface wettability was determined by water contact angle measurements while the chemical composition of the surface was analyzed using XPS. The stability of functional groups on the polymer surface treated with plasma was monitored by XPS and wettability measurements in different time intervals. The oxygen‐plasma‐treated samples showed much more pronounced changes in the surface topography compared to those treated by nitrogen plasma. The contact angle of a water drop decreased from 75° for the untreated sample to 20° for oxygen and 25° for nitrogen‐plasma‐treated samples for 3 s. It kept decreasing with treatment time for both plasmas and reached about 10° for nitrogen plasma after 1 min of plasma treatment. For oxygen plasma, however, the contact angle kept decreasing even after a minute of plasma treatment and eventually fell below a few degrees. We found that the water contact angle increased linearly with the O/C ratio or N/C ratio in the case of oxygen or nitrogen plasma, respectively. Ageing effects of the plasma‐treated surface were more pronounced in the first 3 days; however, the surface hydrophilicity was rather stable later. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

9.
The introduction of antibacterial property, conductivity, wettability and antithrombogenicity into polyolefin‐based membranes has evoked much attention, which can be achieved by coating hydrophilic polymers. Therefore, it is necessary to modify the roughness and hydrophilicity of polyolefin‐based membranes to enhance the coating ability. In this paper, three kinds of plasma methods, including inductively coupled (ICP) plasma, radio frequency low pressure (RFP) plasma and atmospheric dielectric barrier discharge (DBD) plasma, were used to modify the surface of the polyethylene (PE), polypropylene (PP) and polyester‐polypropylene (PET–PP) membranes. The surface roughness of the plasma‐modified PE, PP and PET–PP films was investigated by scanning electron microscopy (SEM) and atomic force microscope (AFM). The polar functional groups of films were observed by energy dispersive spectrometer (EDX) and X‐ray photoelectron spectroscopy (XPS). Besides, the hydrophilicity of the plasma‐modified PE, PP and PET–PP films was evaluated by water contact angle measurement. It was found that the surface roughness and hydrophilicity of plasma‐modified PE, PP and PET–PP films increased with the generation of oxygen‐containing functional groups (i.e. C―O, and C?O). The PET–PP membranes were treated by RFP plasma at different processing powers and times. These results indicated that plasma is an effective way to modify films, and the treatment time and power of plasma had a certain accumulation effect on the membranes' hydrophilicity. As for the roughness and hydrophilicity, the DBD plasma modifies the PE film, which is the optimum way to get the ideal roughness and hydrophilicity. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

10.
This paper is focused on the chemical and morphology changes in the surface of poly(1-butene) (PB-1) generated by plasma treatment. The radio frequency capacitively coupled plasma (air, argon, argon then allylamine, argon containing ammonia and argon with octafluorocyclobutane) was used. Modified surface of PB-1 was characterized by contact angle measurements, X-ray photoelectron spectroscopy, and atomic force microscopy. The surface hydrophilization by air and argon with ammonia plasmas was evaluated as most sufficient. Oppositely, a high level of hydrophobicity of PB-1 surface was reached by combination of argon with octafluorocyclobutane plasma. Upon plasma modification, hydrophilicity/hydrophobicity of treated surfaces remained stable within three days under air atmosphere and then values of contact angle slowly recovered to those of unmodified PB-1. However, morphology and surface chemical composition of plasma-modified samples remained generally unchanged during observed time. Changes in surface hydrophilicity/hydrophobicity of plasma-treated PB-1 were attributed to variance of conformation of the surface molecules.  相似文献   

11.
Heterogeneous nucleation and growth of calcium phosphate (CaP) on sol-gel derived TiO(2) coatings was investigated in terms of surface topography and surface energy. The topography of the coatings was derived from AFM measurements, while the surface energy was determined with contact angle measurements. The degree of precipitation was examined with scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). The precipitation of CaP was found to be dependent on both topography and surface energy. A high roughness value when combining the RMS roughness parameter S(q) with the number of local maxima per unit area parameter S(ds) enhances CaP formation. The hydrophilicity of the coating was also found to be of importance for CaP formation. We suggest that the water contact angle, which is a direct measure of the hydrophilicity of the surface, may be used to evaluate the surface energy dependent precipitation kinetics rather than using the often applied Lewis base parameter.  相似文献   

12.
PVDF/(PEI‐C/PAA)n functional membranes were prepared by layer‐by‐layer (LbL) assembly, and their heavy metal ions adsorption capability was investigated. The changes in the chemical compositions of membrane surfaces were determined by X‐ray photoelectron spectroscopy (XPS). XPS results show that the surface of the PVDF membrane can be alternatively functionalized by PEI‐C and PAA. The membrane surface hydrophilicity was evaluated through water contact angle measurement. Contact angle results show that the surface hydrophilicity of the membrane surface depends on the outermost deposited layer. Morphological changes of membrane surfaces were observed by scanning electron microscopy (SEM). The water fluxes for these membranes were elevated after modification. The performances of the PVDF/(PEI‐C/PAA)n membranes on the adsorption of copper ions (Cu2+) from aqueous solutions were investigated by inductively coupled plasma (ICP). The results indicate that the PVDF/(PEI‐C/PAA)n functional membranes show high copper ions adsorption ability. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

13.
In this work, low pressure glow discharge O2 plasma has been used to increase wettability in a LDPE film in order to improve adhesion properties and make it useful for technical applications. Surface energy values have been estimated using contact angle measurements for different exposure times and different test liquids. In addition, plasma-treated samples have been subjected to an aging process to determine the durability of the plasma treatment. Characterization of the surface changes due to the plasma treatment has been carried out by means of Fourier transformed infrared spectroscopy (FTIR) to determine the presence of polar species such as carbonyl, carboxyl and hydroxyl groups. In addition to this, atomic force microscopy (AFM) analysis has been used to evaluate changes in surface morphology and roughness. Furthermore, and considering the semicrystalline nature of the LDPE film, a calorimetric study using differential scanning calorimetry (DSC) has been carried out to determine changes in crystallinity and degradation temperatures induced by the plasma treatment. The results show that low pressure O2 plasma improves wettability in LDPE films and no significant changes can be observed at longer exposure times. Nevertheless, we can observe that short exposure times to low pressure O2 plasma promote the formation of some polar species on the exposed surface and longer exposure times cause slight abrasion on LDPE films as observed by the little increase in surface roughness.  相似文献   

14.
In this work, polycarbonate-TiO2 nanocomposite films were prepared with different percentages. The aim was to consider the effect of O2 LF plasma (50 Hz) on the hydrophilicity, surface energy, and surface morphology of polycarbonate and polycarbonate-TiO2 nanocomposite. Structure of samples was determined by using X-ray diffraction analysis. In comparison with the reference sample, the samples’ structure did not change after plasma treatment. Surface properties of polycarbonate and polycarbonate-TiO2 nanocomposite films were studied by X-ray photoelectron spectroscopy (XPS), contact angle measurement, atomic force microscopy (AFM), and Vickers microhardness tester. XPS analysis showed that the surface of samples became more oxidized due to plasma treatment. The water contact angle significantly decreased from 88° to 15° after plasma treatment. It was observed that the hardness of the nanocomposite films was not modified after plasma treatment.  相似文献   

15.
通过低温等离子体表面改性技术对疏水性聚丙烯酸酯人工晶状体进行表面改性, 并对改性前后材料的表面结构、形貌和光学性能进行了表征. 静态水接触角结果显示, 经过氨等离子体处理后的人工晶状体亲水性效果最好, 同时最佳的改性时间为120 s, 改性功率为150 W. XPS分析结果进一步证实, 经等离子体处理后, 在人工晶状体表面引入了极性基团. 原子显微镜观察结果显示, 改性后材料表面更加凹凸不平, 粗糙度显著增加而透光率变化很小, 但过大功率改性的样品透光率明显下降. 时效性测试结果表明, 人工晶状体在改性14 d后疏水性恢复趋于稳定.  相似文献   

16.
In this study CO2, H2/H2O and H2O low pressure plasma treatment of poly(tetrafluoroethylene) (PTFE) foils and of thin plasma deposited fluorocarbon polymer (PDFP) films with a structure close to PTFE was investigated. The properties of the plasma were analyzed by mass spectroscopy (MS) and optical emission spectroscopy (OES). The modified fluorocarbon surfaces were characterized by X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), fourier transform infrared (FTIR) spectroscopy, spectroscopic ellipsometry, electrokinetic measurements and dynamic contact angle measurements in order to find optimized treatment conditions. The results of the surface modification were compared with respect to the efficiency of the plasma treatment and the stability of the modification effect at different ambient conditions. It was shown that the H2O plasma treatment is the most effective process for the intended modification. The hydrophobic PTFE surface was converted into a more hydrophilic one. The introduced radicals after the H2O plasma treatment can be utilized subsequently for post plasma reactions such as grafting processes.  相似文献   

17.
Polyacrylonitrile fibers were treated with a nitrogen glow-discharge plasma. The surfaces of untreated and treated fibers were examined with contact angle measurements, atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS). Surface energy calculations of the fibers were carried out from contact angle measurements using the relationships developed by Fowkes. It is found that plasma treatment causes a reduction in water contact angle on the fiber surfaces. The dispersion component of surface energy changes slightly, while the polar component is increased significantly from 14.6 mN/m to 58.7 mN/m and the total surface energy increase is 139%. The increase of surface energy is mainly caused by the introduction of hydrophilic groups on the fiber surfaces after plasma treatment.  相似文献   

18.
Low density polyethylene (LDPE) was modified by plasma immersion ion implantation (PIII) with nitrogen ions of 20 keV. Surface energy and structural transformations were observed during storage of the modified LDPE in air after PIII, by wettability measurements and FTIR-ATR spectra respectively. The appearance of oxygen-containing groups has some kinetic stages with characteristic times from hours to days. The surface energy values attained and comparison with the kinetics of oxidation reveal that the initial changes in the surface energy of LDPE are caused mainly by free radicals and to a lesser extent by oxygen-containing groups. The final surface energies observed after the process known as hydrophobic recovery and the surface energies stabilize are attributable to oxygen-containing groups. The modified surface is “living” and an investigation of the wettability, surface energy, unsaturated and oxygen-containing groups in the surface layer of ion beam modified polymers is incomplete if the kinetics of structural transformations after modification is not taken into account.  相似文献   

19.
A d.c. oxygen glow discharge was used to modify medical‐grade poly(vinyl chloride) (PVC) to study how surface chemistry and hydrophilicity influence Pseudomonas aeruginosa adhesion. The effects of plasma exposure time on the resulting surface, including chemical composition, wettability and roughness, were assessed using x‐ray photoelectron spectroscopy, contact angle measurements and atomic force microscopy analysis. A significant alteration in the hydrophilicity of the native PVC surface was observed after oxygen glow discharge treatment. The water contact angle decreased from ~80° to 8–20°, with a weak dependence of the exposure time used. The change in surface wettability resulted from the incorporation of oxygenated functional groups, including esters, ketones and acids, as indicated by XPS analysis. The amount of oxygen incorporation was shown to be essentially independent of plasma exposure time. However, prolonged plasma exposure resulted in increased surface roughness. Bacterial adhesion efficiency was evaluated for PVC modified by 120 s of plasma exposure, because this exposure time was determined to yield the maximum decrease in contact angle. Oxygen plasma treatment of native PVC was found to yield a 70% reduction in bacterial adhesion for the four strains of Pseudomonas aeruginosa tested. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

20.
Polymethylmethacrylate (PMMA) films were modified by RF oxygen plasma with various powers applied for different periods, and the effects of these parameters on the surface properties such as hydrophilicity, surface free energy (SFE), chemistry, and topography were investigated by water contact angle, goniometer, X‐ray photoelectron spectroscopy (XPS), and atomic force microscopy, and the types of the created free radicals and their decay were detected by electron spin resonance spectroscopy (ESR). SFE and contact angle results varied depending on the plasma parameters. Oxygen plasma treatment (100 W–30 min) enhanced the hydrophilicity of PMMA surface as shown by decreasing the water contact angle from 70° to 26°. XPS analysis showed the change in the amounts of the present functionalities as well as formation of new groups as free carbonyl and carbonate groups. The roughness of the surface increased considerably from ~2 nm to ~75 nm after 100 W–30 min oxygen plasma treatment. ESR analysis indicated the introduction of peroxy radicals by oxygen plasma treatment, and the intensity of the radicals increased with increasing the applied power. Significant decrease in radical concentration was observed especially for the samples treated with higher powers when the samples were kept under the atmospheric conditions. As a conclusion, RF plasma, causes changes in the chemical and physical properties of the materials depending on the applied parameters, and can be used for the creation of specific groups or radicals to link or immobilize active molecules onto the surface of a material. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号