首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Yang JT  Huang KJ  Lin YC 《Lab on a chip》2005,5(10):1140-1147
The effects of geometric parameters on the mixing performance of a staggered herringbone mixer (SHM) with patterned grooves are numerically investigated. Combining use of the software package CFD-ACE+ and the Taguchi method provides a powerful and systematic approach for research on microfluidics. An orthogonal array L9(3(4)) is established for parameters introduced by the groove geometry; in total 9 cases are simulated. Analyses of the mixing phenomena, geometric parameter, pressure loss and flow rate through grooves are conducted. The modes of fluid motion and dominant mechanisms of mixing within the SHM are observed and ascertained. Although the depth ratio and the asymmetry index of the groove are found to be dominant geometric parameters, the rate of flow within the groove is verified to be the most significant factor that affects the mixing performance of a SHM. To date, the effects of the parameters are evaluated within specified ranges, and the true optimum design has yet to be discovered.  相似文献   

2.
Forbes TP  Kralj JG 《Lab on a chip》2012,12(15):2634-2637
We developed a computational model and theoretical framework to investigate the geometrical optimization of particle-surface interactions in a herringbone micromixer. The enhancement of biomolecule- and particle-surface interactions in microfluidic devices through mixing and streamline disruption holds promise for a variety of applications. This analysis provides guidelines for optimizing the frequency and specific location of surface interactions based on the flow pattern and relative hydraulic resistance between a groove and the effective channel. The channel bottom, i.e., channel surface between grooves, was identified as the dominant location for surface contact. In addition, geometries that decrease the groove-to-channel hydraulic resistance improve contact with the channel top. Thus, herringbone mixers appear useful for a variety of surface-interaction applications, yet they have largely not been employed in an optimized fashion.  相似文献   

3.
An analytical model of mixing in the staggered herringbone mixer (SHM) was derived to estimate mixing parameters and provide practical expressions to guide mixer design and operation for a wide range of possible solutes and flow conditions. Mixing in microfluidic systems has historically been characterized by the mixing of a specific solute system or by the redistribution of flow streams; this approach does not give any insight into the ideal operational parameters of the mixer with an arbitrary real system. For Stokes-flow mixers, mixing can be computed from a relationship between solute diffusivity, flow rate, and mixer length. Confocal microscopy and computational fluid dynamics (CFD) modeling were used to directly determine the extent of mixing for several solutes in the staggered herringbone mixer over a range of Reynolds numbers (Re) and Péclet numbers (Pe); the results were used to develop and evaluate an analytical model of its behavior. Mixing was found to be a function of only Pe and downstream position in the mixer. Required mixer length was proportional to log(Pe); this analytical model matched well with the confocal data and CFD model for Pe<5 x 10(4), at which point the experiments reached the limit of resolution. For particular solutes, required length and mixing time depend upon Re and diffusivity. This analytical model is applicable to other solute systems, and possibly to other embodiments of the mixer, to enable optimal design, operation, and estimation of performance.  相似文献   

4.
A computational "toolbox" for the a priori design of optimized microfluidic components is presented. These components consist of a microchannel under low-Reynolds number, pressure-driven flow, with an arrangement of grooves cut into the top and bottom to generate a tailored cross-channel flow. An advection map for each feature (i.e., groove of a particular shape and orientation) predicts the lateral transport of fluid within the channel due to that feature. We show that applying these maps in sequence generates an excellent representation of the outflow distribution for complex designs that combine these basic features. The effect of the complex three-dimensional flow field can therefore be predicted without solving the governing flow equations through the composite geometry, and the resulting distribution of fluids in the channel is used to evaluate how well a component performs a specified task. The generation and use of advection maps is described, and the toolbox is applied to determine optimal combinations of features for specified mixer sizes and mixing metrics.  相似文献   

5.
Jun Yang  Li Qi  Yi Chen  Huimin Ma 《中国化学》2012,30(8):1793-1796
In this work, a 3D mixer has been conceived based on the splitting and recombining mechanism with simple topology structure. This mixer can present excellent performance at extremely low Reynolds number, which is very important for the practical use. Further research exhibits that the mixing also can be realized via the chaotic advection that occurred at decreased aspect ratio of channel. Thus, the changeable mechanism of mixer shows potential of being used widely. Meanwhile, mixing process has been confirmed in a fabricated structure. The simulated flow patterns reappear in a scaled‐up mixer and full mixing can be achieved in 8 mm channel length at varied flow rate. Due to the high efficiency and easy fabrication, this 3D mixer possesses great prospect for a large number of microfluidic systems.  相似文献   

6.
Design and evaluation of a Dean vortex-based micromixer   总被引:2,自引:0,他引:2  
A mixer, based on the Dean vortex, is fabricated and tested in an on-chip format. When fluid is directed around a curve under pressure driven flow, the high velocity streams in the center of the channel experience a greater centripetal force and so are deflected outward. This creates a pair of counter-rotating vortices moving fluid toward the inner wall at the top and bottom of the channel and toward the outer wall in the center. For the geometries studied, the vortices were first seen at Reynolds numbers between 1 and 10 and became stronger as the flow velocity is increased. Vortex formation was monitored in channels with depth/width ratios of 0.5, 1.0, and 2.0. The lowest aspect ratio strongly suppressed vortex formation. Increasing the aspect ratio above 1 appeared to provide improved mixing. This design has the advantages of easy fabrication and low surface area.  相似文献   

7.
A three-dimensional random walk model was developed to evaluate the impact of column geometry on separation efficiency in chromatography systems driven by electroosmotic flow. Contributions of injection plug length, cross-sectional area of channels, and aspect ratio of rectangular channels were examined in these simulation studies. Sample plug length had no impact on efficiency until it exceeded roughly 0.4% of the channel length. Plate height increased rapidly with increasing k' as expected, almost doubling in going from k'=0.25 to 0.35. Channel geometry also had a major effect on efficiency. Plate height increased sharply in rectangular channel columns until the channel aspect ratio reached 4-8. But the effect of channel depth was even more dramatic. Minimum plate height (Hmin) was roughly half that of the channel depth in ideal cases. Hmin in a 10x2 microm channel was at 1.6 mm s(-1). Rectangular channels comparable to those obtained by microfabrication are equivalent to packed column capillary electrochromatography columns in all cases.  相似文献   

8.
Submicrometer-scale periodic structures consisting of parallel grooves were prepared on azobenzene-containing multiarm star polymer films by laser interference. The wetting characteristics on the patterned surfaces were studied by contact angle measurements. Macroscopic distortion of water drops was found on such small-scale surface structures, and the contact angles measured from the direction parallel to the grooves were larger than those measured from the perpendicular direction. A thermodynamic model was developed to calculate the change in the surface free energy as a function of the instantaneous contact angle when the three-phase contact line (TPCL) moves along the two orthogonal directions. It was found that the fluctuations, i.e., energy barriers, on the energy versus contact angle curves are crucial to the analysis of wetting anisotropy and contact angle hysteresis. The calculated advancing and receding contact angles from the energy versus contact angle curves were in good agreement with those measured experimentally. Furthermore, with the groove depth increasing, both the degree of wetting anisotropy and the contact angle hysteresis perpendicular to the grooves increased as a result of the increase in the energy barrier. The theoretical critical value of the groove depth, above which the anisotropic wetting appears, was determined to be 16 nm for the grooved surface with a wavelength of 396 nm. On the other hand, the effect of the groove wavelength on the contact angle hysteresis perpendicular to the grooves was also interpreted on the basis of the thermodynamic model. That is, with the wavelength decreasing, the contact angle hysteresis increased due to the increase in the number of energy barriers. These results may provide theoretical evidence for the design and application of anisotropic wetting surface.  相似文献   

9.
《Electrophoresis》2018,39(12):1452-1459
Harvesting rare circulating tumor cells (CTCs) from human blood is distinctly substantial to monitor tumor stage and evaluate therapeutic efficacy. As a proof‐of‐concept study, a microfluidic chip with twin‐layer herringbone grooves was developed to isolate and recover tumor cells with high efficiency based on the immunoreaction between cells and antibody‐conjugated microbeads (MBs) under local magnetic field. Functional MBs were initially localized onto the internal channel wall through the magnetic guidance. Then, infused tumor cells were deviated into the herringbone groove via passive microvortex and were further trapped through an irreversible interaction with MBs. Upon the removal of magnet, the captured cells and residual MBs were released from the channel and collected for further analysis in cell adhesion and proliferation in vitro. Capture efficiency of tumor cells reached up to ∼90% and limit of detection was down to 50 cells per mL based on this approach. Furthermore, recovery rate of tumor cells was as high as ∼94%, and potencies of cell attachment and proliferation was well maintained in retrieved cells. Hence, the present technique has a great potential for the isolation, quantitation and recovery of CTCs for cancer theranostic guidance and biomolecular analysis.  相似文献   

10.
A new microfluidic mixer is presented consisting of a rectangular channel with grooves placed in the top and bottom. This not only increases the driving force behind the lateral flow, but allows for the formation of advection patterns that cannot be created with structures on the bottom alone. Chevrons, pointing in opposite directions on the top and bottom, are used to create a pair of vortices positioned side by side. Stripes running the width of the channel generate a pair of vertically stacked vortices. Computational fluid dynamics (CFD) simulations are used to model the behavior of the systems and provide velocity maps at cross-sections within the mixer. Experiments demonstrate the mixing that results when two segregated species enter the mixer side-by-side and pass through two cycles of the mixer (i.e., two alternating sets of four stripes and four chevrons).  相似文献   

11.
Rapid droplet mixers for digital microfluidic systems   总被引:3,自引:0,他引:3  
Paik P  Pamula VK  Fair RB 《Lab on a chip》2003,3(4):253-259
The mixing of analytes and reagents for a biological or chemical lab-on-a-chip is an important, yet difficult, microfluidic operation. As volumes approach the sub-nanoliter regime, the mixing of liquids is hindered by laminar flow conditions. An electrowetting-based linear-array droplet mixer has previously been reported. However, fixed geometric parameters and the presence of flow reversibility have prevented even faster droplet mixing times. In this paper, we study the effects of varying droplet aspect ratios (height:diameter) on linear-array droplet mixers, and propose mixing strategies applicable for both high and low aspect ratio systems. An optimal aspect ratio for four electrode linear-array mixing was found to be 0.4, with a mixing time of 4.6 seconds. Mixing times were further reduced at this ratio to less than three seconds using a two-dimensional array mixer, which eliminates the effects of flow reversibility. For lower aspect ratio (相似文献   

12.
The present paper reports on an experimental study of the possibility to use a micro-machined detection groove to enhance the detection sensitivity in flat-rectangular nano-channels for ultra-rapid liquid chromatography separations. Transversally running detection grooves with three different axial widths (respectively, 2, 4 and 6mum) and one depth (4.75mum) were tested in glass and silicon channels for the whole range of detectable fluorescein isothiocyanate isomer I, FITC, concentrations. The groove with the most square-like cross-section (i.e., 4mum wide and 4.75mum deep) yielded the best combination of detection gain and minimal additional band broadening. In a 1cm long channel, the effective plate loss caused by the 4mum wide groove would only be of the order of 20%, while the gain in S/N-ratio was of the order of a factor of 5. The detection groove concept yields larger gains in silicon channel substrates than in glass channel substrates, due to the larger stray light losses occurring in the latter.  相似文献   

13.
Wang AB  Lin IC  Hsieh YW  Shih WP  Wu GW 《Lab on a chip》2011,11(20):3499-3507
To improve the existing trial-and-error process in designing a microfluidic T-junction, a systematic study of the geometrical (mainly the channel length) effects on the generated bubbly/slug flow was conducted to figure out basic design guidelines based on experimental and theoretical analyses. A driving system with dual constant pressure sources, instead of the commonly used dual constant volume-rate sources (such as two syringe pumps), was chosen in this study. The newly proposed effective pressure ratio (P(e)*) has revealed its advantages in excluding the surface tension effect of fluids. All the data of generated bubbly/slug flow for a given geometry collapse excellently into the same relationship of void fraction and effective pressure ratio. This relationship is insensitive to the liquid viscosity and the operation range is strongly affected by the geometrical effect, i.e., the channel length ratio of downstream to total equivalent length of the main channel in a T-junction chip. As to the theoretical design and analysis of gas-liquid-flow characteristics in a microfluidic T-junction, which is still sporadic in the literature, the proposed semi-empirical model has successfully predicted the operation boundaries and the output flow rate of bubbly/slug flow of different investigated cases and demonstrated its usability.  相似文献   

14.
We visualized in real time electrodeposition-driven colloid crystal growth on patterned conductive surfaces. The electrode was patterned with dielectric ribs and conductive grooves; the groove width was commensurate or incommensurate with a two-dimensional colloid crystal lattice. Electrodeposition was carried out against gravity to decouple sedimentation and electrodeposition of colloid particles. Our experiments reveal the following: (i) Colloid crystal growth occurs under the action of electrohydrodynamic forces, in contrast with colloid assembly under the action of capillary forces. (ii) Confinement of the colloid arrays reduces the size of particle clusters. Small clusters easily undergo structural rearrangements to produce close-packed crystals when the groove width is commensurate or nearly commensurate with the 2D lattice. (iii) Incommensurability between the two-dimensional crystalline lattice and the groove width exceeding ca. 15% leads to the formation of non-close-packed structures and the distortion of colloid arrays.  相似文献   

15.
Micromixing of miscible liquids in segmented gas-liquid flow   总被引:2,自引:0,他引:2  
We present an integrated microfluidic system that achieves efficient mixing between two miscible liquid streams by introducing a gas phase, forming a segmented gas-liquid (slug) flow, and completely separating the mixed liquid and gas streams in a planar capillary separator. The recirculation motion associated with segmented flow enhances advection in straight microchannels without requiring additional fabrication steps. Instantaneous velocity fields are quantified by microscopic particle image velocimetry (muPIV). Velocities in the direction normal to the channel amount to approximately 30% of the bulk liquid velocity inside a liquid segment. This value depends only weakly on the length of a liquid segment. Spatial concentration fields and the extent of mixing (EOM) are obtained from pulsed-laser fluorescence microscopy and confocal scanning microscopy measurements. The mixing length is reduced 2-3-fold in comparison with previously reported chaotic micromixers that use three-dimensional microchannel networks or patterned walls. Segmented gas-liquid microflows allow mixing times to be varied over several orders of magnitude between milliseconds and second time scales.  相似文献   

16.
Transparent, biodegradable, mechanically robust, and surface‐patterned silk films were evaluated for the effect of surface morphology on human corneal fibroblast (hCF) cell proliferation, orientation, and ECM deposition and alignment. A series of dimensionally different surface groove patterns were prepared from optically graded glass substrates followed by casting poly(dimethylsiloxane) (PDMS) replica molds. The features on the patterned silk films showed an array of asymmetric triangles and displayed 37–342 nm depths and 445–3 582 nm widths. hCF DNA content on all patterned films were not significantly different from that on flat silk films after 4 d in culture. However, the depth and width of the grooves influenced cell alignment, while the depth differences affected cell orientation; overall, deeper and narrower grooves induced more hCF orientation. Over 14 d in culture, cell layers and actin filament organization demonstrated that confluent hCFs and their cytoskeletal filaments were oriented along the direction of the silk film patterned groove axis. Collagen type V and proteoglycans (decorin and biglycan), important markers of corneal stromal tissue, were highly expressed with alignment. Understanding corneal stromal fibroblast responses to surface features on a protein‐based biomaterial applicable in vivo for corneal repair potential suggests options to improve corneal tissue mimics. Further, the approaches provide fundamental biomaterial designs useful for bioengineering oriented tissue layers, an endemic feature in most biological tissue structures that lead to critical tissue functions.

  相似文献   


17.
Lok KS  Kwok YC  Nguyen NT 《The Analyst》2011,136(12):2586-2591
This paper reports a microchip with an integrated passive micromixer based on chaotic advection. The micromixer with staggered herringbone structures was used for luminol-peroxide chemiluminescence detection. The micromixer was examined to assess its suitability for chemiluminescence reaction. The relationship between the flow rate and the location of maximum chemiluminescence intensity was investigated. The light intensity was detected using an optical fiber attached along the mixing channel and a photon detector. A linear correlation between chemiluminescence intensity and the concentration of cobalt(ii) ions or hydrogen peroxide was observed. This microchip has a potential application in environmental monitoring for industries involved in heavy metals and in medical diagnostics.  相似文献   

18.
We have demonstrated a novel way to form thickness‐controllable polyelectrolyte‐film/nanoparticle patterns by using a plasma etching technique to form, first, a patterned self‐assembled monolayer surface, followed by layer‐by‐layer assembly of polyelectrolyte‐films/nanoparticles. Octadecyltrimethoxysilane (ODS) and (3‐aminopropyl)triethoxysilane (APTES) self‐assembled monolayers (SAMs) were used for polyelectrolyte‐film and nanoparticle patterning, respectively. The resolution of the proposed patterning method can easily reach approximately 2.5 μm. The height of the groove structure was tunable from approximately 2.5 to 150 nm. The suspended lipid membrane across the grooves was fabricated by incubating the patterned polyelectrolyte groove arrays in solutions of 1,2‐dioleoyl‐sn‐glycero‐3‐phosphocholine (DOPC) giant unilamellar vesicles (GUVs). The method demonstrated here reveals a new path to create patterned 2D or 3D structures.  相似文献   

19.
High-density Pd line arrays with 55 nm line-width were obtained using nanocontact-printed dendrimer monolayers. Elastomeric PDMS stamps for nanocontact printing were replicated from silicon master molds which were fabricated by UV nanoimprinting in combination with reactive ion etching. The fabrication method effectively controlled the aspect ratios of high-density lines for resolving the problems encountered in both replicating silicon masters to PDMS stamps and printing with the replicated PDMS stamps. Using the PDMS nanostamp with an optimized aspect ratio, a self-assembled monolayer of dendrimer was patterned on a Pd film via nanocontact printing, which was facilitated by the strong interaction between Pd and amine groups of the dendrimer. The patterned self-assembled monolayer was used as an etch-resist mask against the wet etchant of Pd, leaving behind a high-density Pd line array over large areas. The resulting functional Pd nanopattern is of practical significance in microelectronics and bio- or gas-sensing devices.  相似文献   

20.
Recently, a series of slanted wells on the floor of a microfluidic channel were experimentally shown to successfully induce off-axis transport and mixing of two confluent streams when operating under electroosmotic (EO) flow. This paper will further explore, through numerical simulations, the parameters that affect off-axis transport under EO flow with an emphasis on optimizing the mixing rate of (a). two confluent streams in steady-state or (b). the transient scenario of two confluent plugs of material, which simulates mixing after an injection. For the steady-state scenario, the degree of mixing was determined to increase by changing any of the following parameters: (1). increasing the well depth, (2). decreasing the well angle relative to the axis of the channel, and (3). increasing the EO mobility of the well walls relative to the mobility of the main channel. Also, it will be shown that folding of the fluid can occur when the well angle is sufficiently reduced and/or when the EO mobility of the wells is increased relative to the channel. The optimum configuration for the transient problem of mixing two confluent plugs includes shallow wells to minimize the well residence time, and an increased EO mobility of the well walls relative to the main channel as well as small well angles to maximize off-axis transport. The final design reported here for the transient study reduces the standard deviation of the concentration across the channel by 72% while only increasing the axial dispersion of the injected plug by 8.6 % when compared to a plug injected into a channel with no wells present. These results indicate that a series of slanted wells on the wall of a microchannel provides a means for controlling and achieving a high degree of off-axis transport and mixing in a passive manner for micro total analysis system (microTAS) devices that are driven by electroosmosis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号