首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The theory of multiple headspace solid-phase microextraction (HS-SPME) and a method based on multiple HS-SPME for the quantitative determination of volatile organic compounds (VOCs) in packaging materials is presented. The method allows the direct analysis of solid samples without using organic solvents to extract analytes. Multiple headspace solid-phase microextraction is a stepwise method proposed to eliminate the influence of the sample matrix on the quantitative analysis of solid samples by HS-SPME. Different amounts of packaging and different volumes of standard solution were studied in order to remove a substantial quantity of analytes from the headspace at each extraction and obtain the theoretical exponential decay of the peak area of the four successive extractions and, thus, the total area was calculated from these four extractions. In addition, two fibres were compared: carboxen-polydimethylsiloxane (CAR-PDMS) and divinylbenzene-carboxen-polydimethylsiloxane (DVB-CAR-PDMS), as they showed differences in the linearity of the exponential decay with the number of extractions depending on the compound. The CAR-PDMS fibre was better for the VOCs with a low molecular mass, whereas the DVB-CAR-PDMS fibre was better for the VOCs with a high molecular mass. Finally, the method was characterised in terms of linearity, detection limit and reproducibility and applied to analyse four multilayer packaging samples with different VOCs contents.  相似文献   

2.
Theoretical aspects of multiple solid-phase microextraction are described and the principle is illustrated with the extraction of lidocaine from aqueous solutions. With multiple extraction under non-equilibrium conditions considerably less time is required in order to obtain an extraction yield that is equal to that of one extraction at equilibrium. On the other side, the extraction yield can be increased if multiple extraction is performed with the same total time as is needed for one extraction at equilibrium time. The effect of multiple extraction is strongly dependent on the value of the partition constant and for practical use the length of the desorption time is important. A good agreement between theoretical and experimental data has been obtained. Chromatograms are presented showing the potential of multiple solid-phase microextraction.  相似文献   

3.
自制离子液体固相微萃取涂层分析人体尿液中的五氯酚   总被引:1,自引:0,他引:1  
胡庆兰 《应用化学》2013,30(3):323-328
建立了顶空固相微萃取与气相色谱法(HS-SPME-GC)测定人体尿液中五氯酚(PCP)的新方法。 采用溶胶-凝胶法,加入自制的离子液体键合固相微萃取涂层,优化了萃取温度、萃取时间、pH值、离子强度及解吸时间。 结果表明,样品中加入3 g NaCl,溶液的pH值为2,并以一定速度搅拌的条件下,在80 ℃顶空萃取50 min,300 ℃下解吸5 min,方法的检测限为5.0 ng/L,线性范围为0.05~100 μg/L,相对标准偏差(RSD)为5.9%,加标回收率为106.6%。  相似文献   

4.
A new solid-phase microextraction fiber based on alumina/titania sol-gel-coated on copper wire for headspace sampling of chlorinated organic solvents (chloroform, carbon tetrachloride, trichloroethene, and tetrachloroethene) from urine samples is introduced. The influences of fiber coating composition and microextraction conditions (extraction temperature, extraction time, and ionic strength of the sample matrix) on the fiber performance were investigated. Also, the influence of temperature and time on desorption of analytes from fiber was studied. The proposed fiber has high capacity and demonstrates fast sampling of chlorinated organic solvents from urine samples with high sensitivity. The relative standard deviation (RSD, n=5) for all analytes was below 6.5%.  相似文献   

5.
In-tube solid-phase microextraction (SPME) based on a poly(methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary column was investigated for the extraction of amphetamine, methamphetamine and their methylenedioxy derivatives. The monolithic capillary column showed high extraction efficiency towards target analytes, which could be attributed to its larger loading amount of extraction phase than conventional open-tubular extraction capillaries and the convective mass transfer procedure provided by its monolithic structure. The extraction mechanism was studied, and the results indicated that the extraction process of the target analytes was involved with hydrophobic interaction and ion-exchange interaction. The polymer monolith in-tube SPME-HPLC system with UV detection was successfully applied to the determination of amphetamine, methamphetamine and their methylenedioxy derivatives in urine samples, yielding the detection limits of 1.4 - 4.0 ng/mL. Excellent method reproducibility (RSD < 2.9%) was found over a linear range of 0.05-5 microg/mL, and the time for the whole analysis was only approximately 25 min. The monolithic capillary column was reusable in coping with the complicated urine samples.  相似文献   

6.
Feng J  Sun M  Liu H  Li J  Liu X  Jiang S 《Journal of chromatography. A》2010,1217(52):8079-8086
A novel solid-phase microextraction fiber based on a stainless steel wire coated with Au nanoparticles was prepared and has been applied, coupled with gas chromatography, to the extraction of aromatic hydrophobic organic chemical pollutants in rainwater and soil extract. The solid-phase microextraction fiber exhibited excellent extraction efficiency and selectivity. Effects of extraction time, extraction temperature, ionic strength, stirring rate and desorption conditions were investigated and optimized. Single fiber repeatability and fiber-to-fiber reproducibility were less than 7.90% and 26.40%, respectively. The calibration curves were linear in a wide range for all analytes. Correlation coefficients ranged from 0.9941 to 0.9993. The as-established SPME-GC method was used successfully to two real natural samples. Recovery of analytes spiked at 10 μg L(-1) and 100 μg L(-1) ranged from 78.4% to 119.9% and the relative standard deviations were less than 11.3%.  相似文献   

7.
In the present work, an analytical method for the simultaneous determination of seven non steroidal anti-inflammatory drugs (naproxen, ketoprofen, diclofenac, piroxicam, indomethacin, sulindac and diflunisal) and the anticonvulsant carbamazepine is reported. The method involves preconcentration and clean-up by solid-phase microextraction using polydimethylsiloxane/divinylbenzene fibers, followed by liquid chromatography with diode array detection analysis. Parameters that affect the efficiency of the solid-phase microextraction step such as soaking solvent, soaking period, desorption period, stirring rate, extraction time, sample pH, ionic strength, organic solvent and temperature were investigated using a Plackett-Burman screening design. Then, the factors presenting significant positive effects on the analytical response (soaking period, stirring rate, stirring time) were considered in a further central composite design to optimize the operational conditions for the solid phase microextraction procedure. Additionally, multiple response simultaneous optimization by using the desirability function was used to find the optimum experimental conditions for the on-line solid-phase microextraction of analytes in river water samples coupled to liquid chromatography and diode array detection. The best results were obtained using a soaking period of 5 min, stirring rate of 1400 rpm and stirring time of 44 min. The use of solid-phase microextraction technique avoided matrix effect and allowed to quantify the analytes in river water samples by using Milli-Q based calibration graphs. Recoveries ranging from 71.6% to 122.8% for all pharmaceuticals proved the accuracy of the proposed method in river water samples. Method detection limits were in the range of 0.5-3.0 microgL(-1) and limits of quantitation (LOQs) were between 1.0 and 4.0 microgL(-1) for pharmaceutical compounds in river water samples. The expanded uncertainty associated to the measurement of the concentration ranged between 8.5% and 29.0% for 20 microgL(-1) of each analyte and between 9.0% and 29.5% for the average of different concentration levels. The main source of uncertainty was the calibration step in both cases.  相似文献   

8.
The coextraction of acidic and basic compounds from different mediums is a significant concept in sample preparation. In this work, simultaneous extraction of acidic, basic, and neutral analytes in a single step was carried out for the first time. This procedure employed the dispersive solid‐phase microextraction of analytes with magnetic graphene oxide (graphene oxide/Fe3O4) sorbent followed by gas chromatography with flame ionization detection. After the adsorption of analytes by vortexing and decantation of the supernatant with a magnet, the sorbent was eluted with acetonitrile/methanol (2:1) mixture. The parameters affecting the extraction efficiency were optimized and obtained as follows: sorbent amount 60 mg, desorption time 1 min, extraction time 5 min, pH of the sample 7, sample volume 20 mL, and elution solvent volume 0.3 mL. Under the optimum conditions, linear dynamic ranges were achieved in the range of 0.5–4, 0.25–4, and 0.25–2 μg/mL and limits of detection were 0.341, 0.110, and 0.167 μg/mL for aniline, phenol, and naphthalene, respectively. The relative standard deviations were in the range of 3.3–5.7% in eight repeated extractions. Finally, the applicability of the method was evaluated by the extraction and determination of analytes in stream water and drinking water samples and satisfactory results were obtained.  相似文献   

9.
A polyaniline–multiwalled carbon nanotubes composite fiber was electrodeposited onto a platinum wire using cyclic voltammetry. This fiber was used for headspace solid-phase microextraction combined with gas chromatography and flame ionization detector of trace levels of benzaldehyde in some injectable pharmaceutical formulations. Three solid-phase microextraction parameters including temperature, time and stirring rate were investigated simultaneously using a three-level-three-factor Box–Behnken as experimental design on the extraction capability. The as-made fiber has a lifetime of over 300 extractions without any obvious decline in extraction efficiency. At the optimum conditions (extraction temperature 60°C, extraction time 15 min, stirring rate 700 rpm), the method displays excellent linearity over the concentration range of 25–1000 ng/mL of benzaldehyde with RSD values ranging from 1.0 to 6.8%. The limits of quantitation and detection were 25 and 10 ng/mL, respectively.  相似文献   

10.
C18-MCM-41新型涂层在固相微萃取中的应用   总被引:2,自引:1,他引:1  
固相微萃取(SPME)是集采样、萃取和富集于一体的样品前处理技术,该技术于1990年由Pawliszyn提出。由于其不使用有机溶剂,且简便、快速、样品用量少,因而,倍受分析工作者的青睐。  相似文献   

11.
In this study, an electrochemically enhanced solid-phase microextraction (EE-SPME) approach based on molecularly imprinted polypyrrole/multi-walled carbon nanotubes (MIPPy/MWCNTs) composite coating on Pt wire was developed for selective extraction of fluoroquinolone antibiotics (FQs) in aqueous samples. During the extraction, a direct current potential was applied to the MIPPy/MWCNTs/Pt fiber as working electrode in a standard three-electrode system, FQ ions suffered electrophoretic transfer to the coating surface and then entered into the shape-complimentary cavities by hydrogen-bonding and ion-exchange interactions. After EE-SPME extraction, the fiber was desorbed with desorption solvent for high-performance liquid chromatography (HPLC) analysis. Some parameters influencing EE-SPME extraction such as applied potential, extraction time, solution pH, ionic strength, and desorption solvent were optimized. EE-SPME showed good selectivity and higher extraction efficiency to FQs compared with that of traditional solid-phase microextraction. EE-SPME coupled with HPLC to determine FQs in water samples, the limits of detection (S/N = 3) for the selected FQs are 0.5–1.9 μg L−1. The proposed method was successfully used to the analysis of FQs spiked urine and soil samples, with recoveries of 85.1–94.2% for the urine samples and 89.8–95.5% for the soil samples.  相似文献   

12.
This study presents the use of molecularly imprinted polymer (MIP) as packing material for microextraction by packed syringe (MEPS) to achieve higher extraction selectivity. Pentycaine was used as template for MIP. Development and validation of the determination of lidocaine, ropivacaine, mepivacaine and bupivacaine in human plasma and urine samples utilizing MIP‐MEPS and liquid chromatography–tandem mass spectrometry (LC‐MS/MS) were carried out. The MEPS MIP‐cartridge could be used for 100 extractions before it was discarded. The extraction recovery ranged from 60 to 80%. The correlation coefficients values were >0.999 for all assays using lidocaine, ropivacaine, mepivacaine and bupivacaine in the calibration range 5–2000 nmol/L. The accuracy of the studied compounds, given as a percentage variation from the nominal concentration values, ranged from ‐4.9 to 8.4% using plasma and urine samples. The between‐batch precision, given as the relative standard deviation, at three different concentrations (quality control samples) was ranged from ?4.7 to 14.0% and from 1.8 to 12.7% in plasma and urine, respectively. The lower limit of quantification and limit of detection of the studied substances were 5.0 and 1.0 nm , respectively. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

13.
采用固相微萃取-气相色谱质谱法联用测定了水体中痕量多环麝香类化合物。对固相微萃取条件和解析条件进行了优化,确定了微萃取条件为:选用65μmPDMS-DVB萃取头、顶空萃取模式(HS),在800 r/min,60℃条件下,萃取45 min;萃取过程中保持pH 7并且不加入NaCl;解析条件为:解析时间为3 min,插入GC深度为4 cm,进样口温度为250℃。方法的检测限为0.29~0.37 ng/L,线性范围5~1000ng/L,相对标准偏差1.5%~2.2%。对实际污水厂不同类型的水样使用优化后的实验条件进行了验证试验,目标化合物的回收率在82.5%~92.8%之间,表明优化后的试验条件适用于实际水体中痕量多环麝香类化合物的分析测定。  相似文献   

14.
In this paper the most recent developments in the microextraction of polar analytes from aqueous environmental samples are critically reviewed. The particularities of different microextraction approaches, mainly solid-phase microextraction (SPME), stir-bar-sorptive extraction (SBSE), and liquid-phase microextraction (LPME), and their suitability for use in combination with chromatographic or electrically driven separation techniques for determination of polar species are discussed. The compatibility of microextraction techniques, especially SPME, with different derivatisation strategies enabling GC determination of polar analytes and improving their extractability is revised. In addition to the use of derivatisation reactions, the possibility of enhancing the yield of solid-phase microextraction methods for polar analytes by using new coatings and/or larger amounts of sorbent is also considered. Finally, attention is also focussed on describing the versatility of LPME in its different possible formats and its ability to improve selectivity in the extraction of polar analytes with acid-base properties by using separation membranes and buffer solutions, instead of organic solvents, as the acceptor solution.  相似文献   

15.
Quantification of trace concentrations of transformation products of rocket fuel unsymmetrical dimethylhydrazine (UDMH) in water requires complex analytical instrumentation and tedious sample preparation. The goal of this research was to develop a simple and automated method for sensitive quantification of UDMH transformation products in water using headspace (HS) solid-phase microextraction (SPME) in combination with GC-MS and GC-MS/MS. HS SPME is based on extraction of analytes from a gas phase above samples by a micro polymer coating followed by a thermal desorption of analytes in a GC inlet. Extraction by 85 µm Carboxen/polydimethylsiloxane fiber at 50 °C during 60 min provides the best combination of sensitivity and precision. Tandem mass spectrometric detection with positive chemical ionization improves method accuracy and selectivity. Detection limits of twelve analytes by GC-MS/MS with chemical ionization are about 10 ng L?1. GC-MS provides similar detection limits for five studied analytes; however, the list of analytes detected by this method can be further expanded. Accuracies determined by GC-MS were in the range of 75–125% for six analytes. Compared to other available methods based on non-SPME sample preparation approaches (e.g., liquid–liquid and solid-phase extraction), the developed method is simpler, automated and provides lower detection limits. It covers more UDMH transformation products than available SPME-based methods. The list of analytes could be further expanded if new standards become available. The developed method is recommended for assessing water quality in the territories affected by space activities and other related studies.  相似文献   

16.
Kim S  Park JH  Myung SW  Lho DS 《The Analyst》1999,124(11):1559-1562
Carphedon is a phenyl derivative of nootropil and is effective in increasing physical endurance and cold resistance, and is used for amnesia treatment. Carphedon was extracted from human urine samples by solid-phase microextraction with a 65 microns carbowax-divinylbenzene-coated fiber. This analysis was performed by using capillary gas chromatography with nitrogen-phosphorus detection and optimized at pH 9.6, 30% NaCl, immersion time 10 min and desorption in the GC injector at 250 degrees C for 3 min. The regression equation for carphedon showed good linearity in the range from 0.1 to 10 micrograms ml-1 for human urine samples. The limit of detection was 0.01 microgram ml-1. The developed method is more sensitive and simpler in sample preparation than liquid-liquid extraction and can be applied to doping analysis for stimulants.  相似文献   

17.
Wang G  Tang H  Chen D  Feng J  Li L 《色谱》2012,30(2):135-140
建立了香水中5种合成麝香的顶空固相微萃取-气相色谱-质谱联用分析方法。实验选用65 μm的聚二甲基硅氧烷-二乙烯基苯(PDMS-DVB)萃取纤维,在磁力搅拌600 r/min条件下,考察了萃取温度、平衡时间、萃取时间、解吸时间、进样口温度和盐效应6个方面对实验结果的影响。优化后的条件为: 10 mL顶空瓶中加入适量用水稀释过的样品,于60 ℃平衡3 min后,顶空萃取20 min,随即插入气相色谱进样口,于250 ℃解吸3 min进行定性、定量分析。5种合成麝香在0.05~1.00 μg/g范围内线性关系良好,检出限(LOD)为0.6~2.1 ng/g。空白样品在3个浓度加标水平下(0.05, 0.50, 1.00 μg/g)的回收率为82.0%~103.3%,相对标准偏差(RSD)为1.8%~9.4%。本方法简便、准确、快速、灵敏,适用于香水中合成麝香的分析检验工作。  相似文献   

18.
The construction of a new solid-phase microextraction/surfaced enhanced laser desorption/ionization-ion mobility spectrometry (SPME/SELDI-IMS) device is reported here. A polypyrrole (PPY) coated SPME/SELDI fiber was employed as the extraction phase and SELDI surface to introduce analytes into the IMS. Analytes were directly ionized from the PPY coated fiber tip by a Nd:YAG laser without the addition of a matrix. Optimal experimental parameters, such as extraction conditions and laser parameters, were investigated. The use of a SPME/SELDI fiber simplified the sampling and sample preparation for IMS. Verapamil could be directly extracted from urine sample and analyzed by IMS without any further sample cleanup. This technique could be used for the analysis of drugs and other non-volatile compounds.  相似文献   

19.
A solid-phase microextraction method has been developed for the determination of 19 chlorophenols (CPs) in environmental samples. The analytical procedure involves direct sampling of CPs from water using solid-phase microextraction (SPME) and determination by liquid chromatography with electrochemical detection (LC-ED). Three kinds of fibre [50 microm carbowax-templated resin (CW-TPR), 60 microm polydimethylsiloxane-divinylbenzene (PDMS-DVB) and 85 microm polyacrylate (PA)] were evaluated for the analysis of CPs. Of these fibres, CW-TPR is the most suitable for the determination of CPs in water. Optimal conditions for both desorption and absorption SPME processes, such as composition of the desorption solvent (water-acetonitrile-methanol, 20:30:50) and desorption time (5 min), extraction time (50 min) and temperature (40 degrees C) as well as pH (3.5) and ionic strength (6 g NaCl) were established. The precision of the SPME-LC-ED method gave relative standard deviations (RSDs) of between 4 and 11%. The method was linear over three to four orders of magnitude and the detection limits, from 3 to 8 ng l(-1), were lower than the European Community legislation limits for drinking water. The method was applied to the analysis of CPs in drinking water and wood samples.  相似文献   

20.
A fully automated combination of solid-phase microextraction and on-fiber derivatization coupled with gas chromatography-mass spectrometry was developed to determine 17 chlorophenols in aqueous samples. Optimal parameters for the automated process, such as fiber coating (polyacrylate), derivatization reagent (N,O-bis(trimethylsilyl) trifluoroacetamide), extraction time (60 min), derivatization time (5 min), incubation temperature (35°C), sample pH (3), and ionic strength (300 g L(-1) of NaCl), as well as desorption time (5 min) and desorption temperature (270°C) were established. The whole procedure took only 90 min and was performed automatically. The shortcomings of silylation derivatives, like incompleteness and instability, were overcome by using solid-phase microextraction on-fiber silylation in this study. The results from both pure water and river water samples showed that the method had a good linearity (r(2) = 0.9993-1.0000), ranging from 0.01 to 100 μg L(-1). The related standard deviations were between 3.6 and 10.0%. The limits of detections and qualifications ranged from 0.03 to 3.11 ng L(-1) and 0.09 to 10.4 ng L(-1) for the CPs, respectively. The proposed method is superior to traditional solid phase extraction procedure.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号