首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The speciation of tellurium was carried out using atomic fluorescence spectrometry as an element‐specific detector in hybridization with liquid chromatography and hydride generation. Good resolution could be obtained by anion‐exchange chromatography with complexing agents, using a mobile phase with 8 mM EDTA and 2 mM potassium hydrogenphthalate. Analysis time was less than 6 min. Calibration graphs were linear between 2 and 100 µg l?1. Detection limits were 0.6 µg l?1 and 0.7 µg l?1 for tellurium(VI) and tellurium(IV) respectively. The method was applied to the speciation of tellurium in drinking water and wastewater samples from different metallurgical industries. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

2.
In this work, the determination of total As in seawater by hydride generation atomic fluorescence spectrometry was studied. The influence of the chemical, flow and instrumental parameters were investigated and optimized. The pre-reduction of As(V) to As(III) was performed using KI plus ascorbic acid in 3.5 mol L− 1 HCl medium. No multiplicative interference was present and external aqueous calibration could be used. The limit of detection was 36 ng L− 1, while the repeatability was 2% (n = 10), at a 500 ng L− 1 concentration level. The sample throughput was 15 h− 1 if triplicate measurements were made. The accuracy was assessed by the analysis of a seawater certified reference material and excellent agreement between the obtained and certified values was verified. The procedure was used for the analysis of seawater offshore samples collected at the Brazilian coast and results ranging from 860 to 1200 ng L− 1 were found.  相似文献   

3.
大气沉降物中砷的测定传统方法干扰多,本文针对大气沉降物样品的复杂性,在样品中加入盐酸、硝酸、高氯酸于电热板上加热消解,能有效的消除大量有机质对测量结果的干扰,为大气沉降物研究工作提供更为精准的检测数据。该方法能有效的消除基体干扰,分析成本低,测定的精密度高、准确性好,相对标准偏差(RSD)低于2.0%,样品加标回收率高于90%。  相似文献   

4.
A highly sensitive procedure has been developed for total arsenic and antimony determination in milk samples by hydride generation atomic fluorescence spectrometry after microwave-assisted sample digestion. The discrete introduction of 2 ml of digested sample in the automated continuous flow hydride generation system allows us to reduce drastically the sample and HCl consume and to determine several elements from a same sample digestion. The method provides detection limits of 0.006 and 0.003 ng ml−1, a sensitivity of 2390 and 2840 fluorescence units per ng ml−1 for As and Sb respectively, and average relative standard deviation of 2.3% for As and 4.8% for Sb. The analysis of cow milk samples, obtained from the Spanish market evidenced the presence of As at concentration levels from 3.4 to 11.6 ng g−1 and Sb levels from 3.5 to 11.9 ng g−1, thus in a proportion near to 1:1, which is in contrast with the 10:1 natural ratio between As and Sb and could evidence the effect of the introduction of new alloys and polymer materials in the industrial process of milk. The method was validated by the comparison of data found for commercial samples by using the proposed procedure and reference methods based on dry-ashing and AFS, and microwave-assisted digestion and inductively coupled plasma mass spectrometry determination.  相似文献   

5.
Continuous flow hydride generation coupled with laser induced fluorescence spectrometry (HG-LIF) has been used for the determination of Pb in aqueous samples. Lead hydride is generated in K3Fe(CN)6-HCl medium using NaBH4 as the reducing agent. Parameters such as acidity and the concentrations of oxidising and reducing agents have been studied in order to obtain the highest sensitivity. Laser excitation of Pb has been performed at 283.306 nm and fluorescence has been detected at 365 nm and 405.8 nm. The limit of detection calculated for the optimised conditions (1% K3Fe(CN)6 in 0.3% Oxalic Acid, 0.055 mol L?1 HCl, 1% NaBH4 in 0.1% NaOH) is 0.3 ng mL?1. However, a significant Pb background was observed for blank measurements, which degraded the limit of detection. The limit of detection that is estimated for a Pb free blank was determined by detuning the laser to a wavelength of 282.806 nm and was found to be 0.45 pg mL?1. Method repeatability is 3.5% RSD at the 10 ng mL?1 level. The accuracy of this method has been evaluated by analysis of a water reference material. The results obtained for a multielement standard determined using the HG-LIF approach have been found to be in agreement with those obtained by using a comparison ICP-AES approach. The HG-LIF approach has been applied to the measurement of Pb in a contaminated sediment sample material. The results of this study demonstrate that a small tunable laser system combined with hydride generation sample introduction can be used to measure Pb with high sensitivity, precision and selectivity in different sample matrices.  相似文献   

6.
流动注射在线共沉淀HG-AFS测定痕量铅   总被引:2,自引:0,他引:2  
建立了流动注射在线共沉淀HG-AFS测定痕量铅的分析方法。方法基于铅在碱性介质中与氢氧化镁共沉淀,沉淀收集在锥形沉淀腔中,用HCl溶洗沉淀和NaBH4反应,产生的氢化物被载气引入原子化器中进行测定。测定铅的RSD为3%(5ng/mL,n=10),检出限为0.01ng。检出限较直接进样降低了11倍。对国家标准物质中铅的测定结果与标准值相符。  相似文献   

7.
A rapid, accurate, and precise method is described for the determination of Pb in wine using continuous-flow hydride generation atomic fluorescence spectrometry (CF-HGAFS). Sample pretreatment consists of ten-fold dilution of wine followed by direct plumbane generation in the presence of 0.1 mol L−1 HCl and 1% m/v K3[Fe(CN)6] with 1% m/v NaBH4 as reducing agent. An aqueous standard calibration curve is recommended for Pb quantification in wine sample. The method provides a limit of detection and a limit of quantification of 0.3 μg L−1 and 1 μg L−1, respectively. The relative standard deviation varies between 2–6% (within-run) and 4–11% (between-run) at 3–30 μg L−1 Pb levels in wine. Good agreement has been demonstrated between results obtained by CF-HGAFS and direct electrothermal atomic absorption spectrometry in analyses of red and white wines within the concentration range of 9.2–25.8 μg L−1 Pb.  相似文献   

8.
An electrochemical hydride generation system was developed for the detection of Te by coupling an electrochemical hydride generator with atomic fluorescence spectrometry. Since TeH2 is unstable and easily decomposes in solution, a reticular W filament cathode was used in the present system. The TeH2 generated on the cathode surface was effectively driven out by sweeping gas from the cathode chamber. In addition, a low temperature electrochemical cell (10 °C) was applied to reduce the decomposition of TeH2 in solution. The limit of detection (LOD) was 2.2 ng ml− 1 and the relative standard deviation (RSD) was 3.9% for nine consecutive measurements of standard solution. This method was successfully employed for determination of Te in soldering tin material.  相似文献   

9.
Hydride generation atomic fluorescence spectrometry was for the first time utilized to determine trace toxic element arsenic in the skeleton fossils of four dinosaurs unearthed in Sichuan Province of China. The instrumental limit of detection (LOD) for arsenic was 0.03 μg/L under optimal experimental conditions, which compared favorably to that by ICP-AES and ETAAS. The samples were digested with aqua regia in boiling water bath. The recoveries of standard addition were found to be from 97 to 109%, and the analytical results were found in good agreement with those by ICP-AES. It is a simple, reliable, sensitive yet relatively inexpensive analytical method, compared to ICP-AES, ICP-MS or ETAAS. Interesting analytical results were found that the arsenic concentrations were all abnormally high in the skeleton fossils. The established analytical method and the analytical results may be helpful in revealing the mystery of the mass extinction of the dinosaur fauna. The analytical results, together with other data available to date, supported the argument that the arsenic toxicosis could be a contributing factor for the mass extinction of the dinosaur fauna in Sichuan Province of China.  相似文献   

10.
氢化物发生-原子荧光光谱法测定中草药中的微量铅   总被引:1,自引:0,他引:1  
采用水煎煮法提取中草药,HNO3-H2O2密闭消解体系消解样品,应用氢化物发生-原子荧光光谱法测定中草药及其提取液中的微量铅;优化了仪器工作及实验条件,荧光强度与Pb质量浓度在0.49~400 μg/L范围内呈线性关系,相关系数:0.9996,检出限:0.49 μg/L;发现部分提取液中Pb量比原中草药样品中Pb量有明显降低.  相似文献   

11.
采用HNO3/HClO4(体积比10∶1)消解冶金废水样品,经6mol.L-1 HCl溶液酸化后,加入碘化钾(3%)、抗坏血酸(1%)及硫脲(1%)混合溶液进行还原,用氢化物-原子吸收光谱法(HG-AAS)测定了样品中的As含量.结果表明,该方法的检出限为0.297μg/L,相对标准偏差RSD为5.463%,样品加标回收率为93%~108%;其操作方便、选择性好、灵敏度高、干扰少,适合于复杂废水中微量和痕量As的测定.  相似文献   

12.
A digestion mixture of H2SO4/HNO3/H2O2/HF/V2O5 was investigated for decomposition of plant samples and sensitive detection of selenium was achieved by hydride generation atomic fluorescence spectrometry (HG-AFS). The method was found to be accurate and reproducible, with a low detection limit (DL) (0.14 ng g−1 solution). The repeatability of the determination was mostly around 10%, the reproducibility over a period of 8 months for determination of selenium in the standard reference material Trace Elements in Spinach Leaves, NIST 1570a, was 9% and the relative measurement uncertainty was 7% using a coverage factor of 2.3 at 95% probability. The average recovery of the whole procedure was 90%. The characteristics of this method are simple and inexpensive equipment, low consumption of chemicals and the ability to analyse many samples in a short time. The whole procedure was carried out in the same PTFE tube, and in addition only a simple cleaning procedure is needed. As a consequence of all these advantages, the described method is suitable for environmental and nutritional studies. The selenium content was determined in 44 vegetable samples from different regions of Slovenia and the contents found were in the range 0.3-77 ng g−1 wet weight.  相似文献   

13.
A fast, sensitive and simple non-chromatographic analytical method was developed for the speciation analysis of toxic arsenic species in cereal samples, namely rice and wheat semolina. An ultrasound-assisted extraction of the toxic arsenic species was performed with 1 mol L− 1 H3PO4 and 0.1% (m/v) Triton XT-114. After extraction, As(III), As(V), dimethylarsinic acid (DMA) and monomethylarsonic acid (MMA) concentrations were determined by hydride generation atomic fluorescence spectrometry using a series of proportional equations corresponding to four different experimental reduction conditions. The detection limits of the method were 1.3, 0.9, 1.5 and 0.6 ng g− 1 for As(III), As(V), DMA and MMA, respectively, expressed in terms of sample dry weight. Recoveries were always greater than 90%, and no species interconversion occurred. The speciation analysis of a rice flour reference material certified for total arsenic led to coherent results, which were also in agreement with other speciation studies made on the same certified reference material.  相似文献   

14.
The determinations of As, Bi, Ge, Sb and Se were performed by atomic fluorescence spectrometry following their electrochemical hydride generation. An electrochemical hydride generator based on a screw-thread seal arrangement, working in a continuous flow mode was used. The effects of cathode material, shape and area of material, catholyte, sample flow rate, applied current, catholyte solution concentration and interference of transition metals on signal intensity were studied. Five kinds of materials including lead, graphite, copper, tungsten and platinum with different shapes were tested as cathode materials. The signal obtained from a 3-dimensional electrode was higher than that from a 2-dimensional electrode under the same conditions. The signal intensity of Ge in HNO3 medium within a narrow concentration range of 0.05–0.10 mol L− 1 was stronger than that in other acidic medium, such as HCl and H2SO4. However, the signal intensity of Ge was rapidly decreased with HNO3, HCl and H2SO4 concentration increasing, and then reached approximately zero. In general, limits of detection and a precision were improved using a graphite cathode in H3PO4 medium. The analysis of the reference materials showed good agreement with the certified values for As, Bi, Ge, Sb and Se. The method was successfully applied in the determination of As, Bi, Ge, Sb and Se in traditional Chinese medicine samples.  相似文献   

15.
采用三毛细管微型在线氢化发生技术和装置, 建立了氢化物发生-电热石英管原子吸收法测定纺织品中痕量As、 Sb的分析方法. 研究了共存离子对As、 Sb检测的干扰及消除方法. 结果表明: 该方法除Co、 Sn对As和Ni对Sb有干扰外, 其它干扰元素允许量都较大. 采用酒石酸和KI混合掩蔽剂可抑制Co、 Sn对As和Ni对 Sb的干扰. As和Sb的检出限分别为0.7和0.4 ng/L, 已用于测定纺织品中痕量As和Sb的分析.  相似文献   

16.
The optimisation of an on-line decomposition based on UV photooxidation for the analysis of organoarsenic species by coupling cation-exchange chromatography and atomic fluorescence spectrometry with hydride generation, is described. In this study, special consideration is given to the compatibility of mobile phases with post-column treatments. Results show that the most commonly used mobile phase, aqueous pyridine solutions, decreases species conversion efficiency, leading to a significant loss of sensitivity. New fully-compatible chromatographic conditions are proposed to separate arsenobetaine, arsenocholine, trimethylarsine oxide and tetramethylarsonium ion within 20 min. The very low absolute limits of detection, 4-12 pg(As), allow speciation at trace levels. Analysis of a certified reference fish tissue (DORM-2) and other seafood samples (French and Chilean oysters and mussel) highlights the robustness and the accuracy of the optimised system.  相似文献   

17.
通过电解氢化物发生技术结合原子荧光光谱仪,采用自行设计的管式电解池,研究了管状阴极材料以及电解质种类、电解条件等因素对Cd的电解还原氢化物发生情况的影响。方法检出限为0.26μg/L,相对标准偏差为3.3%(n=11)。对标准物质海带及几种海产品中的Cd进行了测定,回收率在93%~110%之间。  相似文献   

18.
设计了一种新的电化学氢化物发生装置, 用于测定不同价态的硒. 通过对传统的平板电解池的改进, 设计了全新的圆盘电解池并采用螺纹密封的方式, 极大地缩短了电解池的装配时间, 提高了电解池的使用寿命和密封性能. 结合热水浴在线还原技术, 将 Se(Ⅵ)在高浓度HCl介质中120 s内还原成Se(Ⅳ), 通过电化学氢化物发生技术生成氢化物, 成功的进行硒的在线价态分析. 对各种实验参数进行了详细的研究, Se(Ⅳ) 和Se(Ⅵ)的相对标准偏差分别为2.6% 和 3.1% (n=11);Se(Ⅳ)和总硒的检出限分别为0.32和0.27 μg/L (3σ).  相似文献   

19.
A rapid, high sensitivity method has been developed for the determination of As(III), As(V), Sb(III) and Sb(V) in milk samples by using hydride generation atomic fluorescence spectrometry. The method is based on the leaching of As and Sb from milk through the sonication of samples with aqua regia followed by direct determination of the corresponding hydrides both before and after reduction with KI. It was confirmed by recovery experiments on spiked commercially available samples that neither the reduced nor the oxidized forms of the elements under study or mixtures of the two oxidation states were modified by the room temperature sample treatment with aqua regia. The methodologies developed provided 3σ limit of detection values of 8.1, 10.3, 5.4 and 7.7 ng l−1 for As(III), As(V), Sb(III) and Sb(V) in the diluted samples. Average relative standard deviation values of 5.7, 5.5, 8.2 and 4.7% were found for determination of As(III), As(V), Sb(III) and Sb(V) in commercially available samples of different composition and origin containing from 3.5 to 13.6 ng g−1 total As and from 4.9 to 11.8 ng g−1 total Sb, it being confirmed that As(V) and Sb(V) are the main species present in the samples analyzed (62±5 and 73±5%, respectively). The time required to determine As and Sb species in milk involves 10 min sonication and 30 min prereduction but these steps can be carried out for several sample simultaneously. Additionally the fluorescence measurement step involves less than 20 min for three replicates of all the four measurements required. So, in less than 2 h it is possible to determine the content of As(III), As(V), Sb(III) and Sb(V) in four samples.  相似文献   

20.
A method was proposed for the determination of zinc by atomic fluorescence spectrometry with hydride generation from surfactant-based organized media. The ability of different nature micelles to improve hydride generation of zinc was investigated using an intermittent flow hydride generator and the possible mechanism was discussed. The advantages of hydride generation from the organized media of cetyltrimethylammonium bromide (CTAB) were contrasted with that from aqueous media in sensitivity and precision of the zinc determination. The micellar media of CTAB improved the hydride generation processes of zinc both thermodynamically and kinetically. In addition some transition metals, presumably metal borides, were found to catalyze the hydrogenation of zinc. The proposed method has been validated by the determination of zinc in the certified reference materials using the standard addition method with satisfactory result.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏