 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new analytical approach is used in the design of disc-like gradient coils suitable for magnet geometries with main field direction perpendicular to the surface of the disc. An inverse procedure is used to optimize the coil's characteristics, subject to the restrictions imposed by the desired field behavior over a certain set of constraint points inside a predetermined imaging volume. Excellent agreement between the expected values of the gradient magnetic field and the numerical values generated by applying the Biot-Savart law to a discrete current pattern of the perspective disc coil was found. A Finite Element Analysis package was used to predict the fringe gradient field levels for a non-shielded axial disc coil and for a self-shielded transverse disc coil in the vicinity of the magnet poles. The numerical results indicate that for the self-shielded design the gradient fringe field is 1000 times smaller than the corresponding fringe field for the non-shielded disc case. Also no significant spatial dependence was noticed for the shielded coil's fringe field.  相似文献   

2.
A permanent magnet assembly in which the flux density can be altered by a mechanical operation is often significantly smaller than comparable electromagnets and also requires no electrical power to operate. In this paper five permanent magnet designs in which the magnetic flux density can be altered are analyzed using numerical simulations, and compared based on the generated magnetic flux density in a sample volume and the amount of magnet material used. The designs are the concentric Halbach cylinder, the two half Halbach cylinders, the two linear Halbach arrays and the four and six rod mangle. The concentric Halbach cylinder design is found to be the best performing design, i.e. the design that provides the most magnetic flux density using the least amount of magnet material. A concentric Halbach cylinder has been constructed and the magnetic flux density, the homogeneity and the direction of the magnetic field are measured and compared with numerical simulation and a good agrement is found.  相似文献   

3.
A special focused magnet, designed for the use in the magnetic targeted drug delivery system, was constructed. The theoretical calculation of the adhesion condition for a magnetic fluid drop in magnetic field with obtained design showed that the constructed focused magnet generates a sufficient magnetic force for the capture of a magnetic drop on the vessel wall and can be used 1.5–2 cm deeper in an organism compared with the prism permanent magnet, which can enable non-invasivity of the magnetic drug targeting procedure. The maximal values for magnetic field and gradient of magnetic field are 0.38 T and 101 T/m, respectively.  相似文献   

4.
The aim of this work is to design a set of gradient coils with an optimal geometry for magnetic resonance microscopy studies. Designs for a three-axis gradient coil system particularly suited for studies with small radiofrequency coils are presented. The novel geometry involves a planar section with concentric return paths to keep the coil short. Reduction of the external field has been attempted by varying the positions of the return paths using a simulated annealing algorithm. A biplanar version of x- and z-directed prototype gradients was built and tested. A 2D-MR image of a grid phantom has been obtained on a 7-T MR instrument to demonstrate the theory. A three-axis set used as a surface gradient set has also been built and used to obtain high-resolution MR images.  相似文献   

5.
This paper describes a hybrid numerical method for the design of asymmetric magnetic resonance imaging magnet systems. The problem is formulated as a field synthesis and the desired current density on the surface of a cylinder is first calculated by solving a Fredholm equation of the first kind. Nonlinear optimization methods are then invoked to fit practical magnet coils to the desired current density. The field calculations are performed using a semi-analytical method. A new type of asymmetric magnet is proposed in this work. The asymmetric MRI magnet allows the diameter spherical imaging volume to be positioned close to one end of the magnet. The main advantages of making the magnet asymmetric include the potential to reduce the perception of claustrophobia for the patient, better access to the patient by attending physicians, and the potential for reduced peripheral nerve stimulation due to the gradient coil configuration. The results highlight that the method can be used to obtain an asymmetric MRI magnet structure and a very homogeneous magnetic field over the central imaging volume in clinical systems of approximately 1.2 m in length. Unshielded designs are the focus of this work. This method is flexible and may be applied to magnets of other geometries.  相似文献   

6.
To be able to perform a two-dimensional study of free radical distribution by the continuous-wave electron paramagnetic resonance method in the X-band, special coils producing a magnetic gradient of 8 G/mm have been designed and constructed. The EPR spectra recorded for this gradient were subjected to the procedure of deconvolution in order to elicit information on the concentration of the radical distribution. The data obtained were used as the source file of the program reconstructing the image. The reconstruction was based on the iterative simultaneous algebraic reconstruction technique (Andersen A.H., Kak A.C.: Ultrason. Imag. 6, 81–94, 1984). The quality of the generated images depends on the angle of the sample axis to the gradient direction set by a goniometer and on the deconvolution procedures applied. The first tests on artificially generated phantoms indicated a dependence of the obtained images on the magnetic field gradients applied. The determined spatial distribution of radicals has confirmed their uniform distribution in the sample. The preliminary tests were performed for diphenyl-picrylhydrazyl. Having proved the reliability of the method, analogous measurements were also performed for plyphenylene sulphide PPS-V1 and indicated a homogeneous distribution of radicals in the whole volume of the sample. The images obtained confirmed the uniform distribution of the radicals.  相似文献   

7.
王龙庆  王为民 《中国物理 B》2014,23(2):28703-028703
Significant high magnetic gradient field strength is essential to obtaining high-resolution images in a benchtop mag- netic resonance imaging (BT-MRI) system with permanent magnet. Extending minimum wire spacing and maximum wire width of gradient coils is one of the key solutions to minimize the maximum current density so as to reduce the local heating and generate higher magnetic field gradient strength. However, maximum current density is hard to optimize together with field linearity, stored magnetic energy, and power dissipation by the traditional target field method. In this paper, a new multi-objective method is proposed to optimize the maximum current density, field linearity, stored magnetic energy, and power dissipation in MRI gradient coils. The simulation and experimental results show that the minimum wire spacings are improved by 159% and 62% for the transverse and longitudinal gradient coil respectively. The maximum wire width increases from 0.5 mm to 1.5 mm. Maximum gradient field strengths of 157 mT/m and 405 mT/m for transverse and lon- gitudinal coil are achieved, respectively. The experimental results in BT-MRI instrument demonstrate that the MRI images with in-plane resolution of 50 ~tm can be obtained by using the designed coils.  相似文献   

8.
Portable equipment for nuclear magnetic resonance (NMR) is becoming increasingly attractive for use in a variety of applications. One of the main scientific challenges in making NMR portable is the design of light-weight magnets that possess a strong and homogeneous field. Existing NMR magnets can provide such magnetic fields, but only for small samples or in small regions, or are rather heavy. Here we show a simple yet elegant concept for a Halbach-type permanent magnet ring, which can be opened and closed with minimal mechanical force. An analytical solution for an ideal Halbach magnet shows that the magnetic forces cancel if the structure is opened at an angle of 35.3° relative to its poles. A first prototype weighed only 3.1 kg, and provided a flux density of 0.57 T with a homogeneity better than 200 ppm over a spherical volume of 5mm in diameter without shimming. The force needed to close it was found to be about 20 N. As a demonstration, intact plants were imaged and water (xylem) flow measured. Magnets of this type (NMR-CUFF = Cut-open, Uniform, Force Free) are ideal for portable use and are eminently suited to investigate small or slender objects that are part of a larger or immobile whole, such as branches on a tree, growing fruit on a plant, or non-metallic tubing in industrial installations. This new concept in permanent-magnet design enables the construction of openable, yet strong and homogeneous magnets, which aside from use in NMR or MRI could also be of interest for applications in accelerators, motors, or magnetic bearings.  相似文献   

9.
This paper evaluates a new, low-frequency finite-difference time-domain method applied to the problem of induced E-fields/eddy currents in the human body resulting from the pulsed magnetic field gradients in MRI. In this algorithm, a distributed equivalent magnetic current is proposed as the electromagnetic source and is obtained by quasistatic calculation of the empty coil's vector potential or measurements therein. This technique circumvents the discretization of complicated gradient coil geometries into a mesh of Yee cells, and thereby enables any type of gradient coil modelling or other complex low frequency sources. The proposed method has been verified against an example with an analytical solution. Results are presented showing the spatial distribution of gradient-induced electric fields in a multi-layered spherical phantom model and a complete body model.  相似文献   

10.
We present an optimized uniplanar magnetic resonance gradient design specifically tailored for MR imaging applications in developmental biology and histology. Uniplanar gradient designs sacrifice gradient uniformity for high gradient efficiency and slew rate, and are attractive for surface imaging applications where open access from one side of the sample is required. However, decreasing the size of the uniplanar gradient set presents several unique engineering challenges, particularly for heat dissipation and thermal insulation of the sample from gradient heating. We demonstrate a new three-axis, target-field optimized uniplanar gradient coil design that combines efficient cooling and insulation to significantly reduce sample heating at sample-gradient distances of less than 5 mm. The instrument is designed for microscopy in horizontal bore magnets. Empirical gradient current efficiencies in the prototype coils lie between 3.75 G/cm/A and 4.5 G/cm/A with current and heating-limited maximum gradient strengths between 235 G/cm and 450 G/cm at a 2% duty cycle. The uniplanar gradient prototype is demonstrated with non-linearity corrections for both high-resolution structural imaging of tissue slices and for long time-course imaging of live, developing amphibian embryos in a horizontal bore 7 T magnet.  相似文献   

11.
For a superconducting magnet of magnetic resonance imaging (MRI), the novel approach presented in this paper allows the design of cylindrical gradient and shim coils of finite length. The method is based on identification of the weighting of harmonic components in the current distribution that will generate a magnetic field whose z-component follows a chosen spherical harmonic function. Mathematical expressions which relate the harmonic terms in the cylindrical current distribution to spherical harmonic terms in the field expansion are established. Thus a simple matrix inversion approach can be used to design a shim coil of any order pure harmonic. The expressions providing a spherical harmonic decomposition of the field components produced by a particular cylindrical current distribution are novel. A stream function was applied to obtain the discrete wire distribution on the cylindrical-surface. This method does not require the setting of the target-field points. The discussion referring to matrix equations in terms of condition numbers proves that this novel approach has no ill-conditioned problems. The results also indicate that it can be used to design cylindrical-surface shim coils of finite length that will generate a field variation which follows a particular spherical harmonic over a reasonably large-sized volume.  相似文献   

12.
前列腺区域的精确分割是提高计算机辅助前列腺癌诊断准确率的重要前提.本文提出了一种新的精确的前列腺区域分割模型,分为4个步骤:首先,读取T2加权磁共振(MR)图像;其次,利用半径为5个像素的8邻域模板(8x5)的局部二值模式(LBP)特征模板计算前列腺磁共振图像的LBP特征图;然后,利用改进的距离正则化水平集(DRLSE)模型对特征图进行分割,提取前列腺粗轮廓;最后将原始水平集能量函数进行优化,构造一个新的能量函数,提取局部灰度信息和梯度信息,并在此新的能量函数的基础上,将粗轮廓迭代演化为最终的细轮廓.本文将该模型在203组来自于国际光学与光子学学会-美国医学物理学家协会-国家癌症研究所(SPIE-AAPM-NCI)前列腺MR分类挑战数据库的T2W磁共振图像上进行了测试,并与医生手工分割结果进行了比较,结果表明本文提出模型得到的分割结果的Dice系数为0.94±0.01,相对体积差(RVD)为-1.21%±2.44%,95% Hausdorff距离(HD)为6.15±0.66 mm;与文献中现有的分割模型相比,使用本文提出的模型得到的前列腺区域分割结果更接近于手工分割的结果.  相似文献   

13.
Fast Optimization of a Biplanar Gradient Coil Set   总被引:1,自引:0,他引:1  
This work presents an approach for fast optimization of gradient coils, using the simulated annealing method. The shielding condition derived from a target field method and the analytical evaluation of the fields produced by simple geometries were used to reduce the computing time. This method is applied to the optimization of a shielded biplanar gradient coil set. Efficiency, inductance, and homogeneity of the gradient fields produced by the optimized geometries were studied as a function of the number of wires, for the longitudinal and transverse gradient coils. A prototype of the gradient set was made to test the proposed design method. The resulting experimental values of coil efficiency, inductance, field linearity, and shielding performance exhibit good agreement between theory and experiment.  相似文献   

14.
何川  王秋良  白烨 《低温与超导》2006,34(3):183-185,209
文中把目标场法引入到悬浮超导球体的球形线圈设计中,根据目标场法产生均匀磁场的原理,通过离散化绕组来近似处理球形线圈在超导球体和球形线圈的间隙内产生均匀磁场的电流密度分布规律。利用有限元分析和验证,在超导球体与球形线圈之间的间隙内产生了具有很好均匀性的悬浮磁场,这会明显提高超导球体悬浮的刚度和稳定性。  相似文献   

15.
研究了用于锶原子光晶格光钟原子冷却的塞曼减速器,应用增添补偿线圈的方法可以延长减速器的有效减速距离和增大减速器末端的磁场梯度,进而增加一级冷却俘获锶原子的数目,理论分析采用该方法实现的塞曼减速器较使用单一线圈塞曼减速器可以增加31.17%的俘获原子数目;飞行时间法测量了减速前后原子束中原子的速度分布,原子的最可几速度由380m/s降为43m/s,分布线宽相应变窄。荧光法测量俘获原子数目表明在相同实验条件下,应用补偿线圈后磁光阱俘获原子数目从1.26×106提高到1.81×106,增加30.4%。  相似文献   

16.
This work presents a simple design for a mobile single-sided nuclear magnetic resonance (NMR) apparatus with a relatively homogeneous static magnetic field (B0) distribution. In the proposed design, the B0 magnetic field of the apparatus is synthesized using only two permanent magnet blocks, i.e., a cube (main) magnet and a small shim magnet placed above the main magnet. The magnetic flux of the shim magnet partially cancels out that of the main magnet, subsequently creating a smooth B0 profile above the shim magnet where low-resolution NMR experiments are performed. Compared with many previously published designs, this straightforward design simplifies the construction of the apparatus and simultaneously generates a B0 field parallel to the apparatus surface, allowing the use of a simple loop-type radiofrequency (RF) coil. Additionally, an apparatus prototype is constructed according to the proposed design. Weighing only 1.8 kg, the constructed apparatus has a compact structure and can be held in the palm of a hand. The apparatus generates a B0 strength of about 0.0746 T. Within a B0 field deviation of 3 mT, the region with a relatively homogeneous B0 distribution extends to about 11 mm above the shim magnet. The proposed apparatus can detect a clear Hahn echo or Carr-Purcell-Meiboom-Gill (CPMG) echoes of a pencil eraser block or a bottle of oil placed on the apparatus in 5 s with signal averaging using an RF transmitter power of only 19 W; the detection range of the apparatus exceeds 6 mm. The strength of the residual static magnetic field gradient of the apparatus is roughly estimated at 0.58 T/m. Applying different CPMG echo spacings in this residual static gradient leads to various transverse relaxation time (T2) contrasts for liquids with distinct viscosities such as water and oil. Two nondestructive inspection applications of the apparatus, including correlating the concentrations of magnetic nanoparticle solutions with their measured transverse relaxation rates (R2) and monitoring the outgassing from an opened bottle of oxygen-supersaturated water by measuring its longitudinal relaxation rate (R1), are also demonstrated.  相似文献   

17.
A new centric scan imaging methodology for density profiling of materials with short transverse relaxation times is presented. This method is shown to be more robust than our previously reported centric scan pure phase encode methodologies. The method is particularly well suited to density imaging of low gyro-magnetic ratio non-proton nuclei through the use of a novel dedicated one-dimensional magnetic field gradient coil. The design and construction of this multi-layer, water cooled, gradient coil is presented. Although of large diameter (7.62 cm) to maximize sample cross section, the gradient coil has an efficiency of several times that offered by conventional designs (6 mT/m/A). The application of these ideas is illustrated with high resolution density-weighted proton (1H) images of hazelnut oil penetration into chocolate, and lithium ion (7Li) penetration into cement paste. The methods described in this paper provide a straightforward and reliable means for imaging a class of samples that, until now, have been very difficult to image.  相似文献   

18.
A new pulsed field gradient multi-echo imaging technique to encode position in the phase of every echo generated by a CPMG sequence in the presence of a strongly inhomogeneous static magnetic field is presented. It was applied to improve the sensitivity in an imaging experiment by adding the echo train acquired during the CPMG sequence and to spatially resolve relaxation times of inhomogeneous specimens using single-sided probes. The sequence was implemented in a new bar-magnet MOUSE equipped with a gradient coil system to apply a pulsed magnetic field with a constant gradient along one spatial coordinate. An important reduction by a factor larger than two orders of magnitude in the acquisition time was obtained compared to the previously published single-point imaging technique.  相似文献   

19.
A new, portable NMR magnet with a tailored magnetic field profile and a complementary radio frequency sensor have been designed and constructed for the purpose of probing in situ the sub-surface porosity of cement based materials in the built environment. The magnet is a one sided device akin to a large NMR-MOUSE with the additional design specification of planes of constant field strength /B0/ parallel to the surface. There is a strong gradient G in the field strength perpendicular to these planes. As with earlier GARField magnets, the ratio G//:B0/ is a system constant although the method of achieving this condition is substantially different. The new magnet as constructed is able to detect signals 50mm (1H NMR at 3.2 MHz) away from the surface of the magnet and can profile the surface layers of large samples to a depth of 35-40 mm by moving the magnet, and hence the resonant plane of the polarising field, relative to the sample surface. The matching radio frequency excitation/detector coil has been designed to complement the static magnetic field such that the polarising B0 and sensing B1 fields are, in principal, everywhere orthogonal. Preliminary spatially resolved measurements are presented of cement based materials, including two-dimensional T1-T2 relaxation correlation spectra.  相似文献   

20.
Magnetic field gradients play a fundamental role in MR imaging and localized spectroscopy. The MRI experiment, in particular fast MRI, relies on precise gradient switching, which has become more demanding with the constantly growing number of fast imaging techniques. Here we present a simple MR method to measure the behavior of a magnetic field gradient waveform in an MR scanner. The method employs excitation of a thin slice, followed by application of the studied gradient and simultaneous FID acquisition. Measurements of different gradient waveforms were performed with a spherical phantom filled with doped water and positioned at the isocenter of the gradient set. The presented experiments demonstrate the capability of the technique to measure different gradient waveforms with an estimated error of less than 200 microT/m.  相似文献   