首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
建立了毛细管电泳电化学法对盐酸克伦特罗、特布他林和沙丁胺醇进行分离检测。方法采用胶束电泳体系,以铂圆盘为工作电极,考察了检测电位、缓冲液浓度和pH、十二烷基硫酸钠(SDS)浓度、分离电压等因素的影响。3个分离物在10 kV的分离电压、缓冲体系为15 mmol/L(pH 9.0)硼砂+20 mmol/L SDS条件下得到分离。盐酸克伦特罗、特布他林和沙丁胺醇的线性范围分别为2.0~400,3.5~700,5.0~1000μg/L。方法已用于猪肉样品的检测。  相似文献   

2.
Liu S  Wu X  Xie Z  Lin X  Guo L  Yan C  Chen G 《Electrophoresis》2005,26(12):2342-2350
An improved technique, pressurized capillary electrochromatography (pCEC) coupling with end-column amperometric detection (AD), was developed and used for the separation and determination of estrogens. The effects of pH value, composition of mobile phase, concentration of the surfactant sodium dodecyl sulfate (SDS) and applied voltage on separation were investigated. The electrochemical oxidation of diethylstilbestrol (DES), dienestrol (DE), and hexestrol (HEX) could be reliably monitored with a carbon electrode at 0.9 V (vs. Ag/AgCl). The pCEC analyses were performed on a capillary separation column packed with 3 microm C18 particles with an acetonitrile/water (31%: 69%) mobile phase containing Tris buffer (5 mmol/L, pH 4.5) and 4 mmol/L SDS. High voltage up to 12 kV reduced the retention time dramatically and still provided a baseline resolution. In addition, supplementary pressure prevented bubble formation and provided reliability and reproducibility of the pCEC performance. The detection limits for the three estrogens ranged from 1.2 to 2.2x10(-7) mol/L, about 10 20-fold lower than those obtained with pCEC-UV detection. To evaluate the feasibility and reliability of this system, the proposed pCEC-AD method was further demonstrated with fish muscle samples spiked with estrogens.  相似文献   

3.
You T  Liu Z  Yang X  Wang E 《Talanta》1999,49(3):517-521
A rapid and sensitive method is described for the detection of melatonin in rat pineal gland and melatonin tablets. Capillary electrophoresis (CE) with electrochemical detection (EC) was used. This method had high sensitivity and good reproducibility. The detection limit of melatonin was as low as 1.3x10(-9) mol/l (0.30 fg). There was a linear range of concentration from 3.9x10(-7) to 3.25x10(-5) mol/l with a correlation coefficient of 0.999. The linear equation was Y=8.27+0.0042X with a slope of 0.0042 pA/nM. The relative standard deviations of the peak current response and the migration time for 16 continuous injections of 6.5 muM melatonin were 4.5 and 0.48%, respectively. The proposed method was applied to detect melatonin in the rat pineal gland and the melatonin tablets. Good results were obtained compared with previous reports.  相似文献   

4.
微流控芯片电泳分离血清中小而密低密度脂蛋白的研究   总被引:3,自引:3,他引:0  
应用微流控芯片电泳,以40 mmol/L Tricine(pH9.8)作为电泳缓冲体系,十二烷基硫酸钠(SDS)作为添加剂(0.1 mmol/L SDS样品溶液,0.02 mmol/L SDS分离缓冲液),分离血清小而密低密度脂蛋白(sdLDL)。研究荧光染料硝基苯并噁二唑-C6-酰基鞘胺醇(NBD C6-ceramide)与脂蛋白结合的特异性、饱和性以及血清保存和检测时间对脂蛋白电泳行为的影响;探讨SDS有效降低蛋白吸附,提高血清脂蛋白分辨率的作用。冠心病(CHD)组sdLDL检出率(75%)显著高于对照组(6%,P<0.01)。该法具有简易、快速、高效等优点,可望成为CHD危险性评估的常规分析手段。  相似文献   

5.
建立了微乳电动毛细管色谱分离3种氯丙醇的方法。以十二烷基硫酸钠(SDS)作为表面活性剂,系统考察了pH值、缓冲溶液类型和浓度、SDS浓度、助表面活性剂浓度、油相浓度、温度和运行电压对3-氯-1,2-丙二醇(3-MCPD),1,3-二氯-2-丙醇(1,3-DCP),2,3-二氯-1-丙醇(2,3-DCP)分离的影响。结果表明,最佳微乳缓冲液为1%(V/V)正庚烷,100 mmol/L SDS,10%(V/V)正丁醇和8 mmol/L磷酸二氢钠-硼砂溶液(pH 8.50),检测波长为192 nm,温度20℃,分离电压为15 kV。3种氯丙醇的线性范围为2.0×10-6~3.2×10-5 mol/L,相关系数大于0.996,检出限(S/N=3)为0.95~1.9μmol/L。酱油样品经乙醚液液萃取,萃取平均回收率为93.2%~103.0%,相对标准偏差小于6.5%。本方法应用于实际样品和加标后样品中三氯丙醇的检测,结果满意。  相似文献   

6.
胶束电动毛细管色谱分离氨基酸和磷酸化氨基酸   总被引:2,自引:0,他引:2  
本文报道了胶束电动毛细管色谱分离、汞灯诱导荧光电荷耦合器件检测分析氨基酸和磷酸化氨基酸的 4-氟 - 7-硝基苯 - 2 - 口恶 - 1 ,3-丫唑衍生物。研究表明 ,在 p H9.35的 1 0 mmol/L硼砂和 1 0 mmol/L十二烷基硫酸钠的电泳缓冲介质中 ,5种氨基酸和 3种磷酸化氨基酸在 1 0 min内完全分离 ,检测灵敏度为 1 .2 1× 1 0 - 8~ 5 .2 1×1 0 - 8mol/L ,分离效率达 7.3× 1 0 5~ 3.0× 1 0 5/m理论塔板数 ,结果令人满意  相似文献   

7.
微流控芯片测定盐酸金刚烷胺片中的盐酸金刚烷胺   总被引:1,自引:0,他引:1  
建立了微流控芯片非接触电导检测片剂中盐酸金刚烷胺的分析方法.对缓冲液和添加剂的种类及浓度、分离电压、进样时间等进行了优化.实验采用1 mmol/L HAc+2 mmol/L NaAc(pH 4.5)+0.1 mmol/LSDS的缓冲体系,于2.00kV的分离电压下进样10 s,在1 min内实现了盐酸金刚烷胺的快速检测...  相似文献   

8.
建立了胶束电动毛细管色谱结合电化学安培检测同时分析中药马齿苋中多巴胺和去甲肾上腺素的方法。考察了缓冲液的浓度、pH值、十二烷基硫酸钠(SDS)浓度以及工作电极电势对分离检测的影响。在优化的条件下,多巴胺和去甲肾上腺素在1.0×10-6~5 0×10-4mol/L范围内有良好线性,浓度检测限(S/N=3)分别为8 7×10-7mol/L和4 2×10-7mol/L,质量检测限分别为1 45fmol和0 41fmol。该方法组分定性可靠,不需要衍生处理,选择性好。将该法应用于中药马齿苋样品的分析,获得了较好的结果。  相似文献   

9.
建立了微乳液毛细管电动色谱同时分析消炎利胆片中穿心莲内酯和脱水穿心莲内酯的方法。考察了缓冲溶液的浓度、pH值、十二烷基硫酸钠(SDS)以及助表面活性剂的含量对分离测定的影响。在由乙酸乙酯-SDS-正丁醇-30 mmol/L硼砂缓冲液(pH 9.5)(质量比为0.5∶0.6∶6.0∶92.9)组成的微乳液体系中,两种内酯在6 min内完成分离。该法简便、快速、选择性好,用于实际样品中穿心莲内酯和脱水穿心莲内酯的分析,获得了满意的结果。  相似文献   

10.
利用微流控芯片非接触电导检测法测定片剂中盐酸地芬尼多的含量.采用1 mmol/L HAc+2 mmol/L NaAc(pH 4.5)为缓冲溶液,0.2 mmol/L 十二烷基硫酸钠(SDS)为添加剂,在分离电压为2.20 kV,进样时间为10 s下,1 min内实现组分快速分离和检测.盐酸地芬尼多线性范围为5~160 ...  相似文献   

11.
咖啡因及其9种类似物的胶束电动毛细管分析研究   总被引:3,自引:0,他引:3  
周春喜  廖杰  黎力 《色谱》2002,20(3):233-236
 以十二烷基硫酸钠 (SDS)胶束为准固定相 ,考察了咖啡因及其 9种类似物在胶束电动毛细管 (MECC)分离模式下的分离行为。研究了运行缓冲液的 pH值、磷酸盐浓度、SDS浓度、甲醇体积分数、分离电压、分离温度等因素对这 10种化合物的迁移时间和分离效果的影响。结果发现 ,这些因素对上述 10种化合物的分离有显著的影响 ,尤以pH值为最。它不仅影响化合物的迁移时间和分离效率 ,还改变其出峰顺序 ,这与碱性条件下化合物仲胺基上氢的电离有关。优化后的分离条件 :运行缓冲液为 2 0mmol/L磷酸盐 2 0mmol/LSDS(pH 11 0 ) ,分离电压为2 5kV。  相似文献   

12.
Huang Y  Duan J  Chen Q  Chen G 《Electrophoresis》2004,25(7-8):1051-1057
Eight enkephalin-related peptides were derivatized using fluorescein isothiocyanate (FITC), and the derivatization products were separated and detected by capillary electrophoresis with laser-induced fluorescence detection. The optimum molar ratio of FITC and peptide for derivatization was found to be 40:1, and 5 mmol/L sodium borate buffer (pH 9.2) was selected as derivatization media in order to get the high efficiency. Enkephalin-related peptides were completely separated in the pH range of 10.51-10.60 in a running buffer consisting of 100 mmol/L sodium borate and 60 mmol/L sodium dodecyl sulfate (SDS). The detection limit for these eight enkephalins ranged from 0.18 to 2.25 nmol/L, and the linear response range was 1.0 x 10(-6) to 1.0 x 10(-9) mol/L with correlation coefficients between 0.9947-0.9988. A separation efficiency as high as 380000 theoretical plates could be obtained for these analytes.  相似文献   

13.
解娜  丁晓静  宋宝花  李佳  王志 《色谱》2013,31(1):64-70
建立了邻苯二甲醛(OPA)、对氯间二甲基苯酚(PCMX)和三氯生3种杀菌剂同时分离测定的胶束电动毛细管色谱(MEKC)新方法。详细研究了影响上述3种杀菌剂同时分离与准确定量的因素: 如分离缓冲溶液的浓度及pH,十二烷基硫酸钠(SDS)浓度、样品缓冲溶液等。以40.2 cm (有效长度: 30 cm)×50 μm未涂层熔融石英毛细管为分离柱,20 mmol/L硼砂-80 mmol/L SDS(无需调pH)为分离缓冲溶液,2 mmol/L硼砂-8 mmol/L SDS (含体积分数为10%甲醇)为样品缓冲溶液,检测波长为214 nm。3种杀菌剂的校正峰面积的相对标准偏差(RSD)在1.1%~ 3.8%范围内,迁移时间的RSD均小于0.9%, OPA、PCMX和三氯生的检出限(LOD,信噪比为3)分别为4.0、0.4、0.4 mg/L,定量限(LOQ,信噪比为10)分别为12、1.2、1.2 mg/L,校正峰面积与相应的质量浓度分别在12~2 000 mg/L、1.2~200 mg/L和1.2~200 mg/L范围内具有良好的线性关系,相关系数分别为0.9994、0.9993和0.9995。该法前处理简单,可快速、准确地同时测定3种组分,非常适合常规实验室分析。  相似文献   

14.
The sequential simplex strategy has been used to optimize the mobile phase used for separation of inorganic anions by micellar chromatography on a C(18)- micro Bondapak column, with absorption detection at 230 nm. The amount of acetonitrile and the concentration of phosphate buffer (pH 6.0) were chosen for optimization. The optimum mobile phase was found to be 38% acetonitrile in 18.2 mmol L(-1) phosphate buffer (pH 6.0) containing 10 mmol L(-1) cetyltrimethylammonium bromide (CTAB); this optimum was achieved within seven experiments. The separation of the five anions (nitrite, nitrate, iodide, thiocyanate, and thiosulfate) was accomplished in 18 min.  相似文献   

15.
建立了胶束电动毛细管色谱分离和测定大黄及其制剂三黄片中蒽醌类活性组分的方法.考察了背景电解质pH、表面活性剂浓度、有机改性剂种类和浓度对分离的影响.实验结果表明:在缓冲液pH为9.5、SDS浓度为25mmol/L、乙氰浓度为20%时的优化条件下,大黄及三黄片中蒽醌类活性组分得到基线分离且方法具有较好的重现性.  相似文献   

16.
以在线扫集-胶束毛细管电动色谱法(Sweeping-MEKC)测定了复方氨酚烷胺胶囊中的马来酸氯苯那敏、咖啡因和对乙酰氨基酚3种有效成分。考察了缓冲溶液pH值、SDS浓度、分离电压及进样时间等对分离效果的影响。优化条件:以未涂层熔融石英毛细管(55 cm×50μm,有效柱长35 cm)为分离柱;环境温度25℃;80 mmol/L十二烷基磺酸钠+20 mmol/L NaH2PO4(pH 2.2)+15%乙腈为缓冲体系,分离电压-20kV,进样时间60 s(H=20.0 cm),测量波长210 nm。在该条件下氯苯那敏、咖啡因和对乙酰氨基酚在25min内出峰,峰面积RSD均小于4%;线性范围分别为2.45~39.17、1.61~25.76、1.58~25.28 mg/L;检出限(S/N=3)分别达139、34、24μg/L,回收率分别为96%~101%、98%~102%、96%~102%。  相似文献   

17.
李旭菲  杨燕英  周考文 《色谱》2012,30(9):938-942
建立了同时检测氯丙嗪、异丙嗪及其主要代谢物的毛细管电泳电致化学发光新方法。最佳实验条件为: 检测电位1.20 V,钌联吡啶浓度5 mmol/L,检测池磷酸缓冲溶液40 mmol/L (pH 6.5),分离磷酸缓冲溶液18 mmol/L (pH 4.8),进样电压11 kV,进样时间8 s,分离电压13.5 kV。方法的检出限(3σ)分别为氯丙嗪8.3×10~7 g/L、异丙嗪7.2×10~6 g/L、氯丙嗪亚砜1.9×10~5g/L和异丙嗪亚砜3.7×10~6g/L,各组分的电化学发光强度和迁移时间的相对标准偏差(RSD)分别不超过3%和1%。本方法具有简便、快速、灵敏、进样量少和不受共存物干扰等特点,可在不必预分离的情况下直接同时连续测定家犬尿样中的氯丙嗪、异丙嗪、氯丙嗪亚砜和异丙嗪亚砜。  相似文献   

18.
胶束电动毛细管色谱法检测红曲米中的莫纳可林K   总被引:3,自引:1,他引:2  
张良  许杨  李燕萍 《色谱》2010,28(4):393-396
建立了测定红曲米中莫纳可林K含量的胶束电动毛细管色谱(MEKC)方法。考察了运行缓冲液的种类、pH及其浓度、有机添加剂、十二烷基硫酸钠(SDS)的浓度和分离电压等实验条件对电泳分离效果及检测灵敏度的影响。在优化的实验条件下,以20 mmol/L硼砂(pH 10.6,含10%(体积分数)乙醇和40 mmol/L SDS)作为缓冲溶液,莫纳可林K能在23 min内实现很好的基线分离,线性范围为5.00~100.00 mg/L,线性相关系数为0.9976,检出限(以信噪比(S/N)为3计)为0.13 mg/L,加标回收率为98.5%~99.5%。精密度和稳定性试验中,峰面积和迁移时间的相对标准偏差均小于3%,表明重复性良好。该方法简便、快速、灵敏,可用于红曲米中莫纳可林K含量的测定。  相似文献   

19.
刘文叶  乔宏  赵珊  李疆  丁晓静 《色谱》2016,34(3):332-339
建立了双胶束电动毛细管色谱(MEKC)分离测定复方化学消毒剂中有效成分聚六亚甲基单胍(PHMG)、聚六亚甲基双胍(PHMB)、醋酸洗必泰(CHA)及苄索氯铵(BTC)的新方法。以50.2 cm(有效长度:40 cm)×50 μm i.d.未涂层熔融石英毛细管为分离柱,20 mmol/L硼砂+30 mmol/L十二烷基硫酸钠(SDS)+5 mmol/L脱氧胆酸钠(SD)+0.8 g/L聚乙二醇 20000为分离缓冲溶液。详细研究了分离缓冲溶液中各组分浓度、样品提取液对分离的影响。4种物质的检出限和定量限均分别为1 mg/L和3 mg/L。4种物质的校正峰面积与相应质量浓度在3~140 mg/L范围内,均具有良好的线性关系,相关系数均大于0.999。回收率在84.1%~109.6%间,相对标准偏差(RSD)均低于6%。用该法测定了11件复方化学消毒剂样品中PHMG、PHMB、CHA和BTC,与产品标识值基本吻合。该法可成功区分单胍与双胍,且操作简单,适用于消毒产品的质量监督。  相似文献   

20.
苑广信  何巧红  陈恒武  方群  张燕冰 《分析化学》2006,34(12):1693-1696
研究用芯片毛细管电泳激光诱导荧光检测系统分离测定经7-chloro-4-n itrobenzo-2-oax-1,3-d iazole(NBD-C l)衍生的麻黄碱和伪麻黄碱的实验条件。采用胶束毛细管电动色谱分离体系(12 mmol/L SDS 10mmol/L硼砂缓冲液,pH 9.0),在45 mm长的通道上实现了麻黄碱和伪麻黄碱的快速分离,一次分离小于1.5m in。10~100 mg/L范围内,峰高与浓度呈良好的线性关系,麻黄碱、伪麻黄碱的检出限分别是0.83 mg/L和1.10 mg/L。所建立的方法应用于尿中麻黄碱和伪麻黄碱的分离测定,取得满意的结果。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号