首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 672 毫秒
1.
《Electroanalysis》2006,18(6):605-612
This paper reports the construction, characterization and use of copper solid amalgam electrode in the study of the electrochemical behavior of atrazine and ametryne herbicides by square‐wave voltammetry. This study was used as basis for the development of sensitive analytical methods for the determination of these herbicides in natural water, avoiding the use of mercury, by means of a solid electrode that presents high sensitivity and minimizes any environment contamination with mercury residues. The experimental and voltammetric conditions were evaluated and the results showed a reduction peak for atrazine at ?0.98 and at ?1.1 V vs. Ag/AgCl 3.0 mol L?1 for ametryne, both with characteristic of an irreversible electrode reaction in an electrochemical diffusion controlled process, involving two electrons for each herbicide reduction. Based on voltammetric studies, it has been demonstrated that the most possible mechanism for the reduction of herbicides involved reduction of bond carbon‐chloride for atrazine and the reduction of bond carbon–SCH3 for ametryne. The detection limit of herbicides obtained in pure water (laboratory samples) was shown to be lower than the maximum limit of residue established for natural water by the Brazilian Environmental Agency, demonstrating that this methodology is very suitable for determining any contamination by atrazine and ametryne residues in different samples, proving a good substitute for mercury electrodes.  相似文献   

2.
Square-wave voltammetry with the hanging drop mercury electrode as the working electrode was used for the determination of ultratraces of explosives in aqueous solution. It was shown that the strong pressure dependence of the pneumatically controlled multimode electrode system of a conventional Metrohm apparatus could be compensated by an additional pressure regulation, through which the pressure variations could be decreased when switching from deaeration to the static measurements. By using square-wave voltammetry with this electrode system after this modification the limits of detection for 2,4,6-trinitrotoluene (TNT) and other TNT-metabolites could be decreased down to 0.2 μg L−1 when using a measurement time of 6 min. Also a simultaneous determination of TNT and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) was shown to be possible over a wide linear range and the detection limits then were 2.2 μg L−1 for TNT and 25 μg L−1 for RDX. By applying the highly stable and adjustable pressure as mentioned before, the calibrations could be kept stable over a period of up to 1 week.  相似文献   

3.
For the determination of progesterone (P4) electroanalytical studies were performed using mercury electrode (HMDE) and screen-printed boron-doped diamond electrode (BDD-SPE). The effects of pH, supporting electrolyte, accumulation potential and time (Eacc, tacc) were studied in both systems. The optimum conditions were: i) HMDE: pH 7,0; Eacc: −0,1 V and tacc: 40 s, ii) BDD-SPE: 0,5 mol L−1 H2SO4; Eacc: 0,0 V and tacc: 120 s. Under these conditions, the detection limit was 3.1 μg L−1 for HMDE and 45.6 μg L−1 for BDD-SPE. Both methods were validated and applied in the P4 determination on pharmaceutical formulations and milk samples.  相似文献   

4.
An anodic stripping voltammetric procedure for the determination of Cu(II) at an in situ-plated stannum film electrode (SnFE) was described. The results indicated that the SnFE had an attractive electroanalytical performance, with two distinct voltammetric stripping signals for copper and stannum, and showed the superior advantage for the determination of copper compared with the bismuth film electrode. Several experimental parameters were optimized. The SnFE exhibited highly linear behavior in the concentration range from 1.0 to 100.0 μg L−1 of Cu(II) (r = 0.994) with the detection limit of 0.61 μg L−1 (S/N = 3), and the relative standard deviation for a solution containing 40.0 μg L−1 Cu(II) was 2.2% (n = 8). The procedure has been successfully applied for the determination of Cu(II) in lake water sample.  相似文献   

5.
This work describes the application of an ordinary pyrolitic graphite electrode modified by metallophthalocyanine allied to square wave voltammetry for the study of the electrochemical behavior of the herbicide paraquat and the development of a method for its analytical determination in natural water samples. Preliminary experiments indicated that the best responses, considering the intensities of the current and voltammetric profile for the paraquat reduction process, were obtained when the electrode modified by cobalt phthalocyanine was employed, which had a better catalytic activity as a result of this modification compared with that for an unmodified electrode and electrodes modified by iron, manganese and the acid form of the phthalocyanines. Studies of the concentration of cobalt phthalocyanine and the adsorption time showed that 1.0 × 10−4 mol L−1 cobalt phthalocyanine with an adsorption time of 10 min was sufficient to obtain reliability and stability of modification for employment in the development of the electroanalytical procedure for paraquat determination in natural water samples. The variation in pH of a 0.10 mol L−1 Britton–Robinson buffer solution and the square wave parameters indicated that the best conditions to reduce paraquat were pH 7.0, a frequency of 100 s−1, a scan increment of 2 mV and a square wave amplitude of 50 mV. Under such conditions, the variation of paraquat concentrations from 5.00 × 10−7 to 2.91 × 10−5 mol L−1 showed a linear relation, with detection and quantification limits of 26.53 and 88.23 μg L−1; those values were lower than the maximum limits for drinking water permitted by the Brazilian Environmental Council (100 μg L−1), indicating that the method could be employed to analyze paraquat in drinking water samples.  相似文献   

6.
Specific polyclonal antibodies against s-triazine herbicides were obtained by preparing immunogens coupling home-synthesized haptens derivatives of simazine (6-chloro-N-ethyl-N′-ethyl-1,3,5-triazine-2,4-diamine) to lysine groups of hemocyanin from keyhole limpets and bovine serum albumin carrier proteins. Three highly sensitive rabbit antisera were obtained and evaluated with a battery of six enzyme tracers derived from triazine structures in an optimized ELISA format. The antiserum As8 and the HRP-2f tracer, which yield the best assay sensitivity for simazine (detection limit 0.11 ± 0.02 μg L−1, IC50 0.88 ± 0.04 μg L−1), were applied to the development of a sensitive flow-through immunoassay for the analysis of this herbicide. The automated assay was based on a direct competitive immunosorbent assay and fluorescence detection. The optimized method presents an IC50 value of 0.35 ± 0.04 μg L−1 with a detection limit of 1.3 ± 0.9 ng L−1 and a dynamic range from 0.010 to 7.5 μg L−1 simazine. The generic nature of the antiserum was shown by good relative cross-reactivities with other triazines such as atrazine (420%) or propazine (130%) and a lower response to terbutylazine (6.4%) and desethyl-atrazine (2.2%). No cross-reactivity was obtained for nonrelated pesticides such as 2,4-dichlorophenoxyacetic acid or linuron and the assay could be applied as a screening method for triazine herbicides. The total analysis time was 30 min per determination and the immunosensor could be reused for more than 150 cycles without significant loss of activity. The immunosensor has been successfully applied to the direct analysis of simazine in surface water samples at the nanogram per liter level. The results obtained by comparative analysis of the immunosensor with a chromatographic procedure for triazines showed a close correspondence.  相似文献   

7.
The electrochemical behaviour of the pesticide metam (MT) at a glassy carbon working electrode (GCE) and at a hanging mercury drop electrode (HMDE) was investigated. Different voltammetric techniques, including cyclic voltammetry (CV) and square wave voltammetry (SWV), were used. An anodic peak (independent of pH) at +1.46 V vs AgCl/Ag was observed in MT aqueous solution using the GCE. SWV calibration curves were plotted under optimized conditions (pH 2.5 and frequency 50 Hz), which showed a linear response for 17–29 mg L−1. Electrochemical reduction was also explored, using the HMDE. A well defined cathodic peak was recorded at −0.72 V vs AgCl/Ag, dependent on pH. After optimizing the operating conditions (pH 10.1, frequency 150 Hz, potential deposition −0.20 V for 10 s), calibration curves was measured in the concentration range 2.5×10−1 to 1.0 mg L−1 using SWV. The electrochemical behaviour of this compound facilitated the development of a flow injection analysis (FIA) system with amperometric detection for the quantification of MT in commercial formulations and spiked water samples. An assessment of the optimal FIA conditions indicated that the best analytical results were obtained at a potential of +1.30 V, an injection volume of 207 μL and an overall flow rate of 2.4 ml min−1. Real samples were analysed via calibration curves over the concentration range 1.3×10−2 to 1.3 mg L−1. Recoveries from the real samples (spiked waters and commercial formulations) were between 97.4 and 105.5%. The precision of the proposed method was evaluated by assessing the relative standard deviation (RSD %) of ten consecutive determinations of one sample (1.0 mg L−1), and the value obtained was 1.5%.  相似文献   

8.
An adsorptive stripping voltammetric method for the determination of the pesticide dinoseb (2-sec.-butyl-4,6-dinitrophenol) at the mercury film electrode is described. The deposition of the mercury film on a glassy carbon disk electrode was optimized. The temperature, at which the mercury film was deposited, was demonstrated to have a strong influence on the stripping peaks, the first one being much more intense than the second. A systematic study of the variables affecting the stripping response was carried out by differential pulse voltammetry. The results obtained have been compared with those at the HMDE; a significant improvement in the sensitivity of the method developed with the MFE was observed. Using a 300 s accumulation time, the limits of determination and detection were 3.6 × 10–10 and 1.1 × 10–10 mol L–1, respectively. The effect of the presence of several herbicides on the dinoseb response was also tested. The method has been applied to the determination of the pesticide in spiked apple juice at two concentration levels: 12.0 and 1.2 g L–1 of juice.  相似文献   

9.
Summary Eight triazine herbicides, prometon, propazine, atrazine, simazine, prometryn, ametryn, metribuzin, and cyanazine, have been extracted from human whole blood and urine samples by headspace solid-phase microextraction (SPME) with a polydimethylsiloxane-coated fiber and quantified by capillary gas chromatography with nitrogen-phosphorus detection. Extraction efficiencies for all compounds were 0.21–0.99% for whole blood, except for cyanazine (0.06%). For urine, the extraction efficiencies for prometon, propazine, atrazine, prometryn and ametryn were 13.6–38.1%, and those of simazine, metribuzin and cyanazine were 1.35–8.73%. The regression equations for the compounds extracted from whole blood were linear within the concentration ranged 0.01–1 μg (0.5 mL)−1 for prometon, propazine, atrazine, prometryn, and ametryn, and 0.02–1 μg (0.5 mL)−1 for simazine, metribuzin, and cyanazine. For urine, regression equations for all compounds were linear within the concentration range 0.005–0.25 μg mL−1. Compound detection limits were 2.8–9.0 ng (0.5 mL)−1 and 0.4–2.0 ng mL−1 for whole blood and urine, respectively. The coefficients of within-day and day-to-day variation were satisfactory for all the compounds, and not greater than 10.3 and 14.2%, respectively. Data obtained from determination of atrazine in rat whole blood after oral administration of the compound are also presented.  相似文献   

10.
Summary This paper describes a study of the potential of large-volume on-column injection for the determination of triazine herbicides in clean water samples (ground-water). The sensitivity of chromatographic determination has been increased by two orders of magnitude by injection of up to 200 μL of pesticide solutions and nitrogen-phosphorus detection. Analytical characteristics expressed as precision, linear range and limit of detection have been determined, the results indicating adequate analytical performance and the ruggedness of the injection technique. As an application, gas chromatography with large-volume on-column injection and nitrogen-phosphorus detection was combined with off-line liquid-liquid micro-extraction with hexane (1 mL water/1 mL hexane). The procedure was applied to spiked groundwater samples at two concentration levels (1 and 10 μg L−1) with good recoveries (between 81 and 103%, except for deethylatrazine) and repeatability (better than 15% at the 1 μg L−1 level). Limits of detection of the triazine herbicides studied ranged from 0.08 to 0.16 μgL−1.  相似文献   

11.
The optimal process of pre-treatment and activation of gold rotating disc electrode (AuRDE) before voltammetric determination of mercury is proposed. This treatment encompasses polishing of the electrode surface, electrochemical cycling, and activation. This procedure both increases determination sensitivity as well as improves determination reproducibility. The detection limit on the working electrode achieved using this approach amounted to 8.26·10−10 mol L−1for direct mercury determination in water solution (applying 200 s running accumulation). The procedure of the quantitative mercury isolation from complicated sample matrix was developed as well. It provides better selectivity and significant increase of sensitivity of mercury determination. In case of mercury isolation from one liter of water the detection limit is 6.23·10−11 mol L−1 (analyzing a greater sample volume the determined concentration could be lower).   相似文献   

12.
There is an increasing need to assess the harmful effects of heavy-metal-ion pollution on the environment. The ability to detect and measure toxic contaminants on site using simple, cost effective, and field-portable sensors is an important aspect of environmental protection and facilitating rapid decision making. A screen-printed gold sensor in a three-electrode configuration has been developed for analysis of lead(II) by square-wave stripping voltammetry (SWSV). The working electrode was fabricated with gold ink deposited by use of thick-film technology. Conditions affecting the lead stripping response were characterised and optimized. Experimental data indicated that chloride ions are important in lead deposition and subsequent analysis with this type of sensor. A linear concentration range of 10–50 μg L−1 and 25–300 μg L−1 with detection limits of 2 μg L−1 and 5.8 μg L−1 were obtained for lead(II) for measurement times of four and two minutes, respectively. The electrodes can be reused up to 20 times after cleaning with 0.5 mol L−1 sulfuric acid. Interference of other metals with the response to lead were also examined to optimize the sensor response for analysis of environmental samples. The analytical utility of the sensor was demonstrated by applying the system to a variety of wastewater and soil sample extracts from polluted sites. The results are sufficient evidence of the feasibility of using these screen-printed gold electrodes for the determination of lead(II) in wastewater and soil extracts. For comparison purposes a mercury-film electrode and ICP–MS were used for validation.  相似文献   

13.
《Electroanalysis》2006,18(2):186-194
The complex of osmium tetroxide with 2,2′‐bipyridine has been utilized as a probe of DNA structure and an electroactive marker of DNA in DNA hybridization sensors. It produces several voltammetric signals, the most negative of them has been observed only at mercury electrodes. This signal is of catalytic nature affording a high sensitivity of DNA determination. The catalytic current due to evolution of hydrogen in voltammetry of DNA modified by complex of osmium tetroxide with 2,2′‐bipyridine (DNA‐Os,bipy) was studied. Solid amalgam electrodes (modified with mercury menisci) of silver (m‐AgSAE), copper (m‐CuSAE), gold, and of combined bismuth and silver, were used as possible substitutes for mercury electrodes. Besides the hanging mercury drop electrode (HMDE), the catalytic current was observed only on m‐AgSAE and m‐CuSAE. Electrodes of gold and bismuth amalgams did not give the catalytic current. The detection limit of DNA‐Os,bipy on HMDE was 0.1 ng mL?1 (RSD=2.3 %, N=11), and on m‐AgSAE 0.2 ng mL?1 (RSD=3.1%, N=11). The m‐AgSAE was successfully applied as a detection electrode in double‐surface DNA hybridization experiments offering highly specific discrimination between complementary (target) and nonspecific DNAs, as well as determination of the length of a repetitive DNA sequence. The m‐AgSAE has proved a convenient alternative to the HMDE or carbon electrodes used for similar purposes in previous work.  相似文献   

14.
Summary Two procedures, based on large-volume injection with a programmed-temperature vaporizer (PTV), have been developed for the determination of several triazine and organophosphorus pesticides. The use of PTV for injection in gas chromatography (GC) has enabled the introduction of up to 200 μL sample extract into the GC, thus increasing the sensitivity of the method. PTV injection has been combined off-line with two different microextraction procedures—liquid-liquid partition and solid-phase extraction. A simple and rapid off-line liquid-liquid microextraction procedure (5 mL water/1 mL methyltert-butyl ether) was applied to surface water samples spiked at levels between 0.01 and 5μg L−1. Recoveries of the overall procedure were >80% and the precision was better than 15%. Detection limits were <30 ngL−1 from 200-μL injections in GC-NPD analysis of triazines and GC-FPD analysis of organophosphorus pesticides. Off-line automated solid-phase extraction with C18 cartridges has been applied to water samples (50 mL) spiked at 0.01, 0.1 and 1 μg L−1. The overall procedure was satisfactory (recoveries >80% and coefficients of variation <12%) and the limits of detection ranged from 1 to 9 ng L−1. Finally, several surface water samples were anlysed, and triazine herbicides were detected at concentrations of approx. 0.1–0.2 μg L−1. The results were similar to those obtained by conventional solvent extraction then GC-MSD after splitless injection of 2 μL.  相似文献   

15.
 Adsorptive voltammetry was employed for the determination of copper and molybdenum in manganese compounds. As working electrode the hanging mercury drop electrode (HMDE) was used. The method was applied in aqueous solutions of MnCl2 and Mn(NO3)2, as well as in pre-treated manganese dioxide and manganese ores. The detection limits are 3 μg/g for copper and 5 μg/g for molybdenum in the sample. The RSDs at concentration level of 8 μg/g are 2.2 and 3.2% for copper and molybdenum, respectively.  相似文献   

16.
The square-wave voltammetric technique was used to explore the adsorption properties of the astemizole drug. The analytical methodology used was based on the adsorptive preconcentration of the drug on a hanging mercury drop electrode (HMDE), followed by the electrochemical reduction process which yielded a well-defined cathodic peak at −1.184 V (vs. the Ag/AgCl electrode). To achieve high sensitivity, various experimental and instrumental variables were investigated such as the supporting electrolyte, pH, accumulation time and potential, drug concentration, scan rate, SW frequency, pulse amplitude, convection rate, and the working electrode area. Under the optimized conditions, the AdSV peak current was proportional over the analyte concentration range of 5 × 10−7 to 2.5 × 10−6 mol L−1 (r = 0.998) with the detection limit of 1.4 × 10−8 mol L−1 (6.4 ng mL−1). The precision of the proposed method in terms of RSD was 2.4 %, whereas the method accuracy was indicated by the mean recovery of 100.1 %. Possible interferences of several substances usually present in the pharmaceutical tablets and formulations were also evaluated. The applicability of this electroanalytic approach was illustrated by the determination of astemizole in tablets and biological fluids.  相似文献   

17.
Summary Selective on-line solid phase extraction (SPE) and liquid chromatography determination (HPLC) of diquat, paraquat and difenzoquat from environmental water samples has been accomplished with Graphitized Carbon Black (GCB) as both extraction and analytical columns. The method involved passing of 50 mL of water through a cartridge filled with Carbograph. In the elution step, the herbicides were transferred from the cartridge to the analytical column (Hypercarb) by mean of a gradient of pH 3 aqueous solution of tetramethylammonium hydroxide (TMAOH) and ammonium sulphate and methanol. Hypercarb columns were found to give a low probability of false positives for bypiridylium herbicides and are very selective for polar compounds. Recovery was better than 80 %. The breakthrough volume was studied with distilled water spiked with the herbicides at various concentration levels (from 0.1 to 20 μg L−1). The limits of quantification of the method were lower than 0.1 μg L−1. The total analytical method was applied to surface waters from Torreblanca Nature Park (Castelló, Spain). Presented at the 21st ISC held in Stuttgart, Germany, 15th–20th September, 1996.  相似文献   

18.
A survey of contamination of surface and drinking waters around Lake Maggiore in Northern Italy with polar anthropogenic environmental pollutants has been conducted. The target analytes were polar herbicides, pharmaceuticals (including antibiotics), steroid estrogens, perfluorooctanesulfonate (PFOS), perfluoroalkyl carboxylates (including perfluorooctanoate PFOA), nonylphenol and its carboxylates and ethoxylates (NPEO surfactants), and triclosan, a bactericide used in personal-care products. Analysis of water samples was performed by solid-phase extraction (SPE) then liquid chromatography–triple-quadrupole (tandem) mass spectrometry (LC–MS–MS). By extraction of 1-L water samples and concentration of the extract to 100 μL, method detection limits (MDLs) as low as 0.05–0.1 ng L−1 were achieved for most compounds. Lake-water samples from seven different locations in the Southern part of Lake Maggiore and eleven samples from different tributary rivers and creeks were investigated. Rain water was also analyzed to investigate atmospheric input of the contaminants. Compounds regularly detected at very low concentrations in the lake water included: caffeine (max. concentration 124 ng L−1), the herbicides terbutylazine (7 ng L−1), atrazine (5 ng L−1), simazine (16 ng L−1), diuron (11 ng L−1), and atrazine-desethyl (11 ng L−1), the pharmaceuticals carbamazepine (9 ng L−1), sulfamethoxazole (10 ng L−1), gemfibrozil (1.7 ng L−1), and benzafibrate (1.2 ng L−1), the surfactant metabolite nonylphenol (15 ng L−1), its carboxylates (NPE1C 120 ng L−1, NPE2C 7 ng L−1, NPE3C 15 ng L−1) and ethoxylates (NPE n Os, n = 3-17; 300 ng L−1), perfluorinated surfactants (PFOS 9 ng L−1, PFOA 3 ng L−1), and estrone (0.4 ng L−1). Levels of these compounds in drinking water produced from Lake Maggiore were almost identical with those found in the lake itself, revealing the poor performance of sand filtration and chlorination applied by the local waterworks.  相似文献   

19.
The present work reports the critical comparison about the employment of three different supporting electrolytes (0.1 mol L−1 HClO4, 0.01 mol L−1 EDTA-Na2 + 0.06 mol L−1 NaCl + 2.0 mol L−1 HClO4 and 0.1 mol L−1 KSCN + 0.001 mol L−1 HClO4) and their instrumental and chemical optimisation for the simultaneous voltammetric determination of total mercury(II) and copper(II) in sediments and sea water at gold electrode, especially discussing the reciprocal interference problems.  相似文献   

20.
Summary An ion-chromatographic procedure is described for the determination of selenium (VI) at μg L−1 level in the presence of anions and heavy metal ions. Maximum permissible concentrations and effects from each interfering substance were investigated for the Se concentration range 12.5–1,000 μg L−1. The method, optimized for the detection of SeO 4 2− , gives results suitable for speciation analysis. Total selenium can be determined after complete conversion to selenate ion by oxidation with KMnO4. The detection limit of selenium is 4.8 μg L−1 (0.96 ng for 200 μL sample). Paper presented at the 41st Pittsburgh Conference, New York, March 5–9, 1990.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号