首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
As we know, there are usually some problems in electrochemical analysis with bare electrode to detect neurotransmitters. One is low electron transfer rate and the other is interfering compounds, such as ascorbic acid. So some kinds of modified electrodes have been successfully employed to promote the efficiency of electrochemical analysis1-4, such as Nafion modified electrode5,6 and SAM modified electrode7. They can attract positively-charged neurotransmitters while repulse negatively-cha…  相似文献   

2.
郭宪厚  王学亮  郁章玉 《应用化学》2014,31(12):1465-1471
利用循环伏安法制备了石墨烯/铂纳米粒子杂化膜修饰电极,并利用该修饰电极研究了肾上腺素(EP)的电化学行为,建立了测定肾上腺素的电化学方法。 分别利用扫描电子显微镜(SEM)和循环伏安法对电极表面的形貌和电化学性能进行了表征。 试验优化了修饰电极制备过程中影响电极性能的条件和EP的测定条件。 试验结果表明,石墨烯/铂纳米粒子修饰电极对肾上腺素有明显的电催化作用。 在pH=5.0的柠檬酸 磷酸氢二钠缓冲溶液中,EP的氧化峰电流与其浓度在4.4×10-8~2.2×10-6 mol/L的范围内呈良好的线性关系。 线性方程为ipa(10 μA)=0.0753c(mol/L)+3.7653×10-5,r=0.9989,检出限为2.2×10-9 mol/L(S/N=3)。 修饰电极表具有良好的重现性,可用于实际样品的测定。  相似文献   

3.
Poly(o-aminobenzoic acid) (o-ABA) film is deposited on glassy-carbon electrode (GCE) by electropolymerization in pH 7.0 phosphate buffer solution (PBS). Electrochemical behavior of modified electrode is investigated by electrochemical impedance spectroscopy (EIS), different pulse voltammetry (DPV), and cyclic voltammetry (CV). The results indicate that there is a greater resistance during the electron transfer process in poly(o-ABA) film than in bare GCE for the redox of [Fe(CN)6]3−/[Fe(CN)6]4−. Further research indicates that epinephrine (EP) can be strongly absorbed on the surface of the poly(o-ABA) film-modified electrode. The modified electrode shows an excellent electrocatalytical activity on EP oxidation. The EP cathodic peak potential shifts negatively with a slope of −53.5 mV/pH, indicating that equal amounts of proton and electron are involved in the electrode reaction process. In pH 7.0 PBS, the peak current of EP and the concentration has a linear relationship from 0 to 65 μM by amperometric current-time curve. __________ From Elektrokhimiya, Vol. 41, No. 9, 2005, pp. 1059–1065. Original English Text Copyright ? 2005 by Cheng, Jin, Zhang. The text was submitted by the authors in English.  相似文献   

4.
This paper describes the simultaneous determination of epinephrine (EP), uric acid (UA) and xanthine (XN) in the presence of ascorbic acid (AA) using electropolymerized ultrathin film of 5-amino-1,3,4-thiadiazole-2-thiol (p-ATT) modified glassy carbon (GC) electrode in 0.2 M phosphate buffer solution (pH 5). Although bare GC electrode resolves the voltammetric signals of AA and XN, it fails to resolve the voltammetric signals of EP and UA in a mixture. However, the p-ATT modified electrode not only separates the voltammetric signals of AA, EP, UA and XN with potential difference of 150, 120 and 400 mV between AA-EP, EP-UA and UA-XN, respectively but also shows higher oxidation current for these molecules. The p-ATT modified electrode exhibits excellent selectivity towards the oxidation of EP, UA and XN in the presence of 40-fold higher concentration of AA. Further, the p-ATT modified electrode was also used for the selective determination of EP in the presence of 40-fold higher concentrations of AA, UA and XN. Using amperometric method, we achieved the lowest detection of 40 nM EP and 60 nM each UA and XN. The amperometric current response was increased linearly with increasing EP concentration in the range of 4.0 × 10−8 to 4.0 × 10−5 M and the detection limit was found to be 27 × 10−11 M (S/N = 3). The practical application of the present modified electrode was demonstrated by determining the concentration of EP in epinephrine tartrate injection and XN in human urine samples.  相似文献   

5.
A carbon paste electrode modified with electropolymerized fills of isonicotinic acid was developed.The modified electrode shows excellent electrocatalytic activity toward the oxidation of both dopamine(DA)and epinephrine(EP).Separation of the reduction peak potentials for dopamine and epinephrine was about 357 mV in pH 5.3 phosphate buffer solution(PBS)and the character was used for the detection DA and EP simultaneously.The peak currents increase linearly with DA and EP concentration over the range of 8.0×10-5 to 7.0×10-4 mol/L and 5.0×10-6 to 1.0×10-4 mol/L with detection limits of 2 × 10-5 and 1×10-6 mol/L,respectively.The interference studies showed that the modified electrode exhibits excellent selectivity in the presence of large excess of ascorbic acid(AA).  相似文献   

6.
Gold nanoparticles were self-assembled to the modified glassy carbon electrode (GC) with cysteamine (CA) to prepare the nano-Au/CA/GC modified electrode. The electrochemical behavior of epinephrine (EP) on the modified electrode was explored with cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Epinephrine gave a pair of redox peaks at Epa = 0.190 mV and Epc = −0.224 mV (versus SCE), respectively. The nano-Au/CA/GC modified electrode shows an excellent electrocatalytic activity for the oxidation of EP. The modified electrode could be used to determine EP in the presence of ascorbic acid (AA). The response of catalytic current with EP concentration shows a linear relation in the range of 1.0 × 10−7 to 5.0 × 10−4 mol L−1 with the correlation coefficient of 0.998. The detection limit is 4.0 × 10−8 mol L−1. The modified electrode exhibited a good reproducibility, sensitivity and stability for the determination of EP injection.  相似文献   

7.
用循环伏安法制备银掺杂聚L-酪氨酸修饰玻碳电极,研究了多巴胺、肾上腺素和抗坏血酸在其电极上的电化学行为,建立了同时测定多巴胺、肾上腺素和抗坏血酸的新方法。当3种组分共存时,在磷酸盐缓冲溶液(pH6.0)中,扫描速率为140mV/s,多巴胺和肾上腺素在修饰电极上分别产生还原峰,峰电位分别为0.198和-0.205V,多巴胺和肾上腺素氧化峰重叠,峰电位为0.313V(vs.Ag/AgCl);抗坏血酸产生一个氧化峰,峰电位0.108V(vs.Ag/AgCl)。多巴胺和肾上腺素的ΔEpc=0.403V,抗坏血酸的氧化峰与多巴胺和肾上腺素的ΔEpa=0.205V,用还原峰和氧化峰可同时测定多巴胺、肾上腺素和抗坏血酸,3种组分同时测定的线性范围分别为5.0×10-6~1.0×10-4mol/L,8.0×10-6~1.0×10-4mol/L和3.0×10-5~1.0×10-3mol/L;检出限分别为5.0×10-7,8.0×10-7和5.0×10-6mol/L。本方法用于人尿液中多巴胺、肾上腺素和抗坏血酸的同时测定,结果满意。  相似文献   

8.
Aspartic acid was covalently grafted on to a glassy carbon electrode (GCE) by amine cation radical formation in the electrooxidation of the amino-containing compound. X-ray photoelectron spectroscopic (XPS) measurement and cyclic voltammetric experiments proved the aspartic acid was immobilized as a monolayer on the GCE. Electron transfer to Fe(CN)64– in solution of different pH was studied by cyclic voltammetry. Changes in solution pH resulted in the variation of the charge state of the terminal group; surface pKa values were estimated on the basis of these results. Because of electrostatic interactions between the negatively charged groups on the electrode surface and dopamine (DA) and ascorbic acid (AA), the modified electrode was used for electrochemical differentiation between DA and AA. The peak current for DA at the modified electrode was greatly enhanced and that for AA was significantly reduced, which enabled determination of DA in the presence of AA. The differential pulse voltammetric (DPV) peak current was linearly dependent on DA concentration over the range 1.8×10–6–4.6×10–4 mol L–1 with slope (nA mol–1 L) and intercept (nA) of 47.6 and 49.2, respectively. The detection limit (3) was 1.2×10–6 mol L–1. The high selectivity and sensitivity for dopamine was attributed to charge discrimination and analyte accumulation. The modified electrode has been used for determination of DA in samples, in the presence of AA, with satisfactory results.  相似文献   

9.
任旺  张英  李敏娇 《电化学》2011,17(3):343-346
应用电沉积方法制备柠檬酸修饰电极(CA/GC), 差分脉冲法研究多巴胺(DA)和肾上腺素(EP)在该修饰电极上的电化学行为.结果表明, 两样品DA、EP在该电极的还原峰电位差380 mV, 而抗坏血酸(AA)在此电位区无还原峰, 因此可实现该修饰电极对DA和EP的同时检测, 而且高浓度AA不发生干扰.在pH 6.0的磷酸盐缓冲液中, DA和EP还原峰电流与其浓度分别在1.0×10-6 ~ 6.0×10-5 mol•L-1和2.0×10-6 ~ 6.0×10-5 mol•L-1 范围内呈线性关系.CA/GC电极制备简单, 重现性好, 可望用于多巴胺针剂(DA)和肾上腺素针剂(EP)的同时检测  相似文献   

10.
利用配对试剂将二茂铁酰胺键合在L-半胱氨酸自组装单层膜(SAM)表面, 制成稳定的二茂铁/L-半胱氨酸修饰电极, 该电极在pH 7.0的磷酸盐缓冲液中有一对很好的氧化还原峰. 运用循环伏安法和交流阻抗谱详细研究了修饰电极的电化学行为, 测得电子转移系数为0.66, 表观电极反应速率常数为6.86 s-1. 该修饰电极对肾上腺素有很好的催化作用, 峰电流与肾上腺素浓度在2.0×10-7~1.0×10-5 mol·dm-3范围内呈现良好的线性关系.  相似文献   

11.
A sensitive and selective electrochemical method for the determination of epinephrine(EP) was developed using a modified carbon paste electrode(MCPE) with 2,2’-[3,6-dioxa-1,8-octanediylbis(nitriloethylidyne)]-bis-hydroquinone(DOH).Cyclic voltammetry was used to investigate the redox properties of this modified electrode at various solution pH values and at various scan rates.In differential pulse voltammetry,the modified electrode could separate the oxidation peak potentials of EP and uric acid(UA) present in the solution but at the unmodified CPE the peak potentials were indistinguishable.This method was also examined for determination of EP in EP injection.  相似文献   

12.
An electropolymerized film of eriochrome black T (EBT) has been prepared at a glassy carbon electrode (GCE) by cyclic voltammetry (CV). The poly(EBT) membrane at GCE exhibits an excellent electrocatalytic activity towards the oxidation of epinephrine (EP), ascorbic acid (AA) and uric acid (UA) in acidic solution and reduced the overpotential for the oxidation of EP. The poly(EBT)-coated electrode could separately detect EP, AA and UA in their mixture with the potential differences of 180 and 160 mV for EP-AA and UA-EP, respectively, which are large enough to allow for determination of EP in the presence of AA and UA. Using differential pulse voltammetry, the peak current of EP recorded in pH 3.5 solution was linearly dependent on EP's concentration in the range of 2.5 - 50 microM. Due to its good selectivity and stability, the polymer-coated GCE was successfully applied to the determination of EP in real samples.  相似文献   

13.
《Electroanalysis》2005,17(11):941-945
A glassy carbon electrode (GCE) was modified with electropolymerized films of cresol red in pH 5.6 phosphate buffer solution (PBS) by cyclic voltammetry (CV). The modified electrode shows an excellent electrocatalytic effect on the oxidation of norepinephrine (NE). The peak current increases linearly with the concentration of NE in the range of 3×10?6–3×10?5 M by the differential pulse voltammetry. The detection limit was 2×10?7 M. The modified electrode can also separate the electrochemical responses of norepinephrine and ascorbic acid (AA). The separation between the anodic peak potentials of NE and AA was 190 mV by the cyclic voltammetry. And the responses to NE and AA at the modified electrode were relatively independent.  相似文献   

14.
《Electroanalysis》2004,16(23):1977-1983
2,2‐bis(3‐Amino‐4‐hydroxyphenyl)hexafluoropropane (BAHHFP) was electro‐polymerized oxidatively on glassy carbon by cyclic voltammetry. The activity of the modified electrode towards ascorbic acid (AA), uric acid (UA) and dopamine (DA) was characterized with cyclic voltammetry and differential puls voltammetry (DPV). The findings showed that the electrode modification drastically suppresses the response of AA and shifts it towards more negative potentials. Simultaneously an enhancement of reaction reversibility is seen for DA and UA. Unusual, selective preconcentration features are observed for DA when the polymer‐modified electrode is polarized at negative potential. In a ternary mixture containing the three analytes studied, three baseline resolved peaks are observed in DPV mode. At physiological pH 7.4, after 5 min preconcentration at ?300 mV, peaks positions were ?0.073, 0.131 and 0.280 V (vs. Ag/AgCl) for AA, DA and UA, respectively. Relative selectivities DA/AA and UA/AA were over 4000 : 1 and 700 : 1, respectively. DA response was linear in the range 0.05–3 μM with sensitivity of 138 μA μM?1 cm?2 and detection limit (3σ) of 5 nM. Sensitive quantification of UA was possible in acidic solution (pH 1.8). Under such conditions a very sharp peak appeared at 630 mV (DPV). The response was linear in the range 0.5–100 μM with sensitivity of 4.67 μA μM?1 cm?2 and detection limit (3σ) of 0.1 μM. Practical utility was illustrated by selective determination of UA in human urine.  相似文献   

15.
Li J  Lin XQ 《Analytica chimica acta》2007,596(2):222-230
A novel biosensor was fabricated by electrochemical deposition of gold nanoclusters on ultrathin overoxidized polypyrrole (PPyox) film, formed a nano-Au/PPyox composite on glassy carbon electrode (nano-Au/PPyox/GCE). The properties of the nanocomposite have been characterized by field emission scanning electron microscope (FE-SEM), X-ray photoelectron spectroscopy (XPS), powder X-ray diffraction (XRD) and electrochemical investigations. The nano-Au/PPyox/GCE had strongly catalytic activity toward the oxidation of epinephrine (EP), uric acid (UA) and ascorbic acid (AA), and resolved the overlapping voltammetric response of EP, UA and AA into three well-defined peaks with a large anodic peak difference. The catalytic peak currents obtained from differential pulse voltammetry increased linearly with increasing EP and UA concentrations in the range of 3.0 × 10−7 to 2.1 × 10−5 M and 5.0 × 10−8 to 2.8 × 10−5 M with a detection limit of 3.0 × 10−8 and 1.2 × 10−8 M (s/n = 3), respectively. The results showed that the modified electrode can selectively determine EP and UA in the coexistence of a large amount of AA. In addition, the sensor exhibited excellent sensitivity, selectivity and stability. The nano-Au/PPyox/GCE has been applied to determination of EP in epinephrine hydrochloride injection and UA in urine samples with satisfactory results.  相似文献   

16.
We report on a sensor for epinephrine (EP) that is based on an ITO electrode modified with multi-walled carbon nanotubes pre-coated with a polymerized ionic liquid (PIL-MWNTs). A chitosan film was then electrodeposited on the ITO electrode in the presence of EP (the template) and the PIL-MWNTs. This film acts as an excellent recognition matrix due to its excellent film-forming ability and the many functional groups that favor hydrogen bond formation with the target (EP). The PIL-MWNTs, in turn, can improve the sensing performance due to their good electrical conductivity, high dispersity, and large surface area. The imprinted films were characterized by scanning electron microscopy, X-ray diffraction, Fourier transform IR spectroscopy, and thermogravimetric analysis. The electrochemistry of the imprinted electrode was investigated by cyclic voltammetry, electrochemical impedance spectroscopy, differential pulse voltammetry and chronoamperometry. The response to EP is linear in the 0.2 μM to 0.67 mM concentration range, and the detection limit is as low as 60 nM (at an S/N of 3). The electrode is reusable and offers good reproducibility and stability.
Figure
An epinephrine imprinted electrode was facile achieved by electrodepositing chitosan on ITO surface in the presence of epinephrine and polymerized ionic liquid-functionalized carbon nanotubes, followed by removal of the epinephrine template molecule. Specific recognition of EP molecule and its determination were realized at this imprinted sensor.  相似文献   

17.
This article describes the highly sensitive and selective determination of epinephrine (EP) using self‐assembled monomolecular film (SAMF) of 1,8,15,22‐tetraamino‐phthalocyanatonickel(II) (4α‐NiIITAPc) on Au electrode. The 4α‐NiIITAPc SAMF modified electrode was prepared by spontaneous adsorption of 4α‐NiIITAPc from dimethylformamide solution. The modified electrode oxidizes EP at less over potential with enhanced current response in contrast to the bare Au electrode. The standard heterogeneous rate constant (k°) for the oxidation of EP at 4α‐NiIITAPc SAMF modified electrode was found to be 1.94×10?2 cm s?1 which was much higher than that at the bare Au electrode. Further, it was found that 4α‐NiIITAPc SAMF modified electrode separates the voltammetric signals of ascorbic acid (AA) and EP with a peak separation of 250 mV. Using amperometric method the lowest detection limit of 50 nM of EP was achieved at SAMF modified electrode. Simultaneous amperometric determination of AA and EP was also achieved at the SAMF modified electrode. Common physiological interferents such as uric acid, glucose, urea and NaCl do not interfere within the potential window of EP oxidation. The present 4α‐NiIITAPc SAMF modified electrode was also successfully applied to determine the concentration of EP in commercially available injection.  相似文献   

18.
利用电聚合方法在石墨烯修饰的玻碳电极表面制备了聚亚甲基蓝/石墨烯修饰电极(PMB/GH/GCE)。采用循环伏安法(CV)和差分脉冲伏安法(DPV)研究了多巴胺(DA)和抗坏血酸(AA)在该修饰电极上的电化学行为。在pH 6.9的磷酸盐缓冲溶液中,DA和AA分别在0.208 V和-0.108 V处产生灵敏的氧化峰,与其在聚亚甲基蓝和石墨烯单层修饰电极上的电化学行为相比,两者的峰电流明显增加,峰电位差达316 mV。研究表明,电聚合方法使亚甲基蓝牢固地非共价修饰到石墨烯上,并产生协同增效作用,较好地提高了电极的灵敏度和分子识别性能,有利于在大量AA存在下实现对DA的选择性测定。在1.00×10-3mol/L AA的存在下,DA的差分脉冲伏安法峰电流与其浓度在1.00×10-7~5.00×10-3mol/L范围内呈良好的线性关系,检出限达1.00×10-8mol/L。将该方法用于盐酸多巴胺注射液的测定,结果满意。  相似文献   

19.
A glassy carbon electrode was modified with an electropolymerized film of 1‐naphthylamine in aqueous solution. The electrocatalytic properties of this modified electrode (ME) were investigated using ascorbic acid (AA) as probe molecule. The electrochemical behavior of AA in buffer solution was examined by voltammetry and amperometry. The results showed that the ME exhibited good electrocatalytic activity towards the oxidation of AA, as a consequence, it can be used as amperometric sensor of this analyte in a flow injection system with good sensitivity. Calibration curves were linear over the concentration range 0.05–1.50 mM with a phosphate buffer solution pH 3 as the carrier, the detection limit was 1 ppm (S/N=3). The methods were applied to the determination of AA in beverages and pharmaceutical products. A good correlation with a reference method was attained.  相似文献   

20.
A new chemically modified electrode is constructed based on iron(III) doped zeolite modified carbon paste electrode (Fe(3+)Y/ZCME). The electrode was evaluated as a sensor for sub-micromolar determination of tryptophan (Trp), uric acid (UA) and ascorbic acid (AA) in aqueous solutions. The measurements were carried out by application of the differential pulse voltammetry (DPV) method in phosphate buffer solution with pH 3.5. Iron(III) loaded in zeolite can increase anodic peak currents by adsorption of Trp, UA and AA on electrode surface The analytical performance was evaluated with respect to the carbon paste composition, pH of solution, accumulation time and accumulation potential. The prepared electrode shows voltammetric responses with high sensitivity and selectivity for Trp, UA and AA in optimal conditions, which makes it very suitable for simultaneous determination of these compounds. The linear calibration range for AA in the presence of 50muM UA and 50muM Trp was 0.6muM to 100muM, with a correlation coefficient of 0.9992, and a detection limit of 0.21muM (S/N=3). A linear relationship was found for UA in the range of 0.3-700muM containing 10muM AA and 50muM Trp, with a correlation coefficient of 0.9990 and a detection limit of 0.08muM. The linear calibration range for Trp in the presence of 10muM AA and 50muM UA was 0.2-150muM, with a correlation coefficient of 0.9996, and a detection limit of 0.06muM. The proposed method was successfully applied for determination Trp, UA and AA in biological systems and pharmaceutical samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号