首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
This paper describes an electrochemiluminescent (ECL) based method for chiral recognition and detection of both glutamate (Glu) enantiomers. The luminophore luminol (Lum) was used as both the reductant and stabilizer of Ag nanoparticles (AgNP-Lum) which were combined with carbon quantum dots (C-dots) and placed on a glassy carbon electrode (GCE) along with the enzyme glutamate oxidase (GluOx). The use of these materials is found to result in strong amplification of ECL. The nanomaterials used were characterized by transmission electron microscopy (TEM) and Fourier transform infrared (FTIR). The stepwise fabrication of the electrode was verified by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Under optimized conditions and by applying a typical potential of 0.6 V, the ECL increases linearly in the 5.0 μM to 5.0 mM Glu concentration range, with a 1.6 μM lower detection limit and satisfactory selectivity. A Glu logic gate idea has been designed that is based on this enzymatic biosensor.
Graphical abstract Schematic presentation of the electrochemiluminescent (ECL) biosensor. A glassy carbon electrode (GCE) was modified with C-dots and silver nanoparticles which were deoxidized by luminol (AgNP-Lum) for enzymatic specific detection.
  相似文献   

2.
Hydrothermal treatment of a mixture of ethylene diamine, phosphoric acid and citric acid under ambient pressure generates fluorescent carbon dots that are co-doped with phosphorus and nitrogen. These have features such as (a) both green fluorescence (peaking at 430 nm; 30% quantum yield) and red fluorescence (peaking at 500 nm, quantum yield 78%), (b) wavelength-dependent emission peaks, and (c) insensitivity to changes of pH values, dot concentration and ionic strength. The C-dots are useful for both fluorescent (FL) and photoacoustic (PA) imaging of living tissue. PA imaging warrants better spatial resolution and allows deeper tissues to be imaged compared to most optical imaging techniques. It is essential to assign a photoacoustic contrast agent as most of the diseases do not show a natural photoacoustic contrast in their early stage. The dually emitting C-dots are shown to be a useful contrast agent for PA and FL imaging of mice tumors. Intravenous administration of the C-dots resulted in strong signals in both PA and FL imaging.
Graphical abstract Photographs of the excitation wavelength-dependent fluorescence of P,N-doped C-dots obtained from ethylenediamine, phosphoric acid and citric acid. Intravenous administration of the C-dots resulted in strong signals in both photoacoustic (PA) and fluorescent (FL) imaging.
  相似文献   

3.
We describe the preparation of carbon quantum dots (C-dots) by a one-step hydrothermal method starting from o-aminophenol as the precursor. The C-dots exhibit bright both blue fluorescence (with excitation/emission peaks at 300/410 nm and with quantum yield of 0.40) and green fluorescence (420/500 nm; QY 0.28) without any other element doping. The unique emission properties are attributed to a synergistic effect of amino and hydroxy groups on the surface of the C-dots. The C-dots are shown to be viable fluorescent probes for heparin. The positively charged surface amino groups are assumed to interact with sulfate and carboxy groups in heparin via electrostatic interactions and hydrogen bonding. This causes the blue fluorescence of C-dots to be turned off (quenched). Fluorescence is strongest at a pH value of 6. The fluorometric calibration plot is linear in the 10 to 100 nM concentration range, with an 8.2 nM detection limit (at a signal-to-noise ratio of 3).
Graphical abstract Carbon quantum dots with dual fluorescence emission bands were synthesized and are shown to be a viable fluorescent probe for heparin.
  相似文献   

4.
A composite material obtained by ultrasonication of graphene oxide (GO) and multi-walled carbon nanotubes (MWCNTs) was loaded with manganese dioxide (MnO2), poly(diallyldimethylammonium chloride) and gold nanoparticles (AuNPs), and the resulting multilayer hybrid films were deposited on a glassy carbon electrode (GCE). The microstructure, composition and electrochemical behavior of the composite and the modified GCE were characterized by transmission electron microscopy, Raman spectra, energy-dispersive X-ray spectroscopy, electrochemical impedance spectroscopy and cyclic voltammetry. The electrode induces efficient electrocatalytic oxidation of dopamine at a rather low working voltage of 0.22 V (vs. SCE) at neutral pH values. The response is linear in the 0.5 μM to 2.5 mM concentration range, the sensitivity is 233.4 μA·mM ̄1·cm ̄2, and the detection limit is 0.17 μM at an SNR of 3. The sensor is well reproducible and stable. It displays high selectivity over ascorbic acid, uric acid and glucose even if these are present in comparable concentrations.
Graphical abstract Gold nanoparticles were self-assembled onto the surface of the MnO2 decorated graphene oxide-carbon nanotubes composites with poly(diallyldimethylammonium chloride) (PDDA) as a coupling agent. Further, a sensitive electrochemical sensor of dopamine was developed via immobilizing this nanocomposite on a glassy carbon electrode (GCE).
  相似文献   

5.
Reduced graphene oxide hollow microspheres (rGO HMS) were encapsulated with gold nanoparticles (AuNPs) by spray drying. Scanning electron microscopy, transmission electron microscopy, X-ray diffraction and Raman spectroscopy were used to characterize the AuNP/rGO HMS. When placed on a glassy carbon electrode (GCE), it exhibits excellent electrochemical catalytic properties towards the oxidation of nitrite. The electrocatalytic properties were studied using various electrochemical techniques. Compared to AuNP-decorated graphene sheet based electrodes documented in the literature, the one presented here provides a larger surface area. This enhances the catalytic activity towards nitrite. The electrode, typically operated at a working potential of 0.82 V (vs. SCE), has a linear response in the 5.0 μM to 2.6 mM nitrate concentration range, and a detection limit as low as 0.5 μM (at an S/N ratio of 3).
Graphical abstract Schematic presentation of the synthesis of graphene hollow microspheres encapsulated with of gold nanoparticles (AuNP/rGO HMS) through a spray drying technique. The material was applied to the electrochemical determination of nitrite.
  相似文献   

6.
A colorimetric and fluorescent pH probe was designed by doping carbon dots (C-dots) with Eu(III), Tb(III) and 2,6-pyridinedicarboxylic acid (DPA). The resulting nanoparticles were applied as fluorescent indicators for pH values (best detected at excitation/emission wavelengths of 272/545, 614 nm). The pH induced optical effects are due to pH induced variations in energy transfer. The fluorescence of the probe shows a continuous color variation, and a linear change with pH values in the range from 3.0 to 10.0 can be established by using a Commission Internationale de L’Eclairage (CIE) chromaticity diagram. This new kind of pH nanoprobe is more accurate than previously reported pH indicator probes because the pH value can be calculated by using chromaticity coordinates that only depend on the chromaticity. The pH nanoprobe was applied to visualize pH values in human breast adenocarcinoma cells (MCF-7).
Graphical abstract Carbon dots modified with Eu(III) and Tb(III) complexes of 2,6-pyridinedicarboxylic acid (DPA) were prepared. The doped carbon dots were used as a pH-sensitive nanosensor. The fluorescence chromaticity of the nanoparticles changes with the variation of pH value.
  相似文献   

7.
A conducting polymer composite was prepared from nano-sized hydroxyaptite (nHAp) doped into poly(3,4-ethylenedioxythiophene) (PEDOT) and then electrodeposited on a glassy carbon electrode (GCE). The nHAp carries carboxy groups and therefore is negatively charged at moderate pH value. When doped into PEDOT (PEDOT-nHAp), it forms a uniform and stable film that exhibits low electrochemical impedance, a large specific surface, and high activity toward the electrochemical oxidation of nitrite. Under optimized conditions and at a relatively low working potential of 0.78 V (vs. SCE), the modified GCE exhibited a linear amperometric response in the 0.25 μM to 1.05 mM nitrite concentration range, and the limit of detection is as low as 83 nM.
Graphical abstract A highly sensitive nitrite sensor was developed based on conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) doped with carboxyl group functionalized hydroxyapatite nanoparticles, which exhibited a large surface area and good conductivity and stability.
  相似文献   

8.
A strategy was developed for the voltammetric determination of the antibiotic drug levofloxacin (LV) based on a glassy carbon electrode modified with a composite consisting of poly(o-aminophenol) and graphene quantum dots (PoAP/GQD) that was fabricated by electropolymerization. The PoAP/GQD composite provides a large surface area and sensing interface and strongly promotes the oxidation current of LV. Under optimal conditions, the modified GCE displays an oxidation peak current (best measured at a working voltage of 1.05 V vs. SCE) that is linearly related to the levofloxacin concentration in the range from 0.05 to 100 μM, and the detection limit is 10 nM (at an S/N of 3). The method was applied to the determination of levofloxacin in spiked milk samples where is gave recoveries between 96.0 and 101.0 %.
Graphical Abstract We describe a one-step electrochemical polymerization method to synthesize a layer of conductive film of poly(o-aminophenol) and graphene quantum dots (PoAP/GQD) onto a glassy carbon electrode (GCE) surface. The composite film exhibited high electro catalytic activity for the quantitative determination of levofloxacin by stripping voltammetry.
  相似文献   

9.
A glassy carbon electrode (GCE) was modified with gold nanoparticles (AuNPs) coated on monolayer graphene (AuNP/MG) by direct in situ sputtering of AuNPs on CVD-generated graphene. This process avoids complicated polymer transfer and polymer cleaning processes and affords AuNPs with a clean surface. The monolayer graphene is ductile and well dispersed. The clean surface of the AuNPs renders this sensor superior to GCEs modified with AuNPs on reduced graphene oxide in terms of the amperometric non-enzymatic determination of hydrogen peroxide. The detection limit is 10 nM (S/N = 3) at 0.55 V (vs. SCE), which is lower than that for similar methods, and the response time is as short as 2 s. Another attractive feature of the sensor is its feasibility for large-scale production via CVD and sputtering.
Graphical abstract Gold nanoparticles deposited onto monolayered graphene generated by chemical vapor deposition (CVD) are used for electrochemical sensing of H2O2, with the detection limit of 10 nM (S/N = 3) and response time of less than 2 s.
  相似文献   

10.
The work describes a hybrid electrochemical sensor for highly sensitive detection of the anesthetic lidocaine (LID). Porous carbon (PC) was synthesized from an isoreticular metal-organic framework-8 (IRMOF-8) and drop cast onto a glassy carbon electrode (GCE). A layer of a molecularly imprinted polymer (MIP) layer was then fabricated in situ on the modified GCE by electro-polymerization, with LID acting as the template and resorcinol as the functional monomer. Hexacyanoferrate is used as an electrochemical probe. The electrical signal (typically acquired at 0.335 V vs. SCE) increases linearly in the 0.2 pM to 8 nM LID concentration range, with a remarkable 67 fM detection limit (at an S/N ratio of 3). The sensor is stable and selective. Eventually, rapid and accurate detection of LID in spiked real samples was successfully realized.
Graphical abstract ?
  相似文献   

11.
A glassy carbon electrode (GCE) modified with polymeric nanocomposite consisting of palladium nanoparticles and a conductive polymeric ionic liquid was prepared. The modified GCE was applied to sensitive and fairly selective electrochemical determination of the mycotoxin zearalenone. Electrocatalytic oxidation is performed in a solution containing 20 % (V/V) acetonitrile and 80 % (V/V) of 1 M perchloric acid. Cyclic voltammetry and square wave voltammetry revealed a well-defined electrocatalytic peak current at overpotential of +0.69 V versus Ag/AgCl. Under optimized experimental conditions, there is a linear relationship between anodic peak current and zearalenone concentration in the range from 0.03 to 35 ng?mL ̄1, and the detection limit is 0.01 ng?mL ̄1. The method was successfully applied to the analysis of zearalenone in spiked food samples and gave recoveries between 95.6 and 104.0 %.
Graphical abstract The nanocomposite (PdVC-PIL) was prepared by polymerization of ionic liquid monomer (PIL) in presence of Pd nanoparticles on Vulcan XC-72R carbon (PdVC). The solution containing nanocomposite was placed on the glassy carbon electrode (GCE). The voltammetry activity of modified electrode (PdVC-PIL/GCE) was compared to a bare GCE for zearalenone determination.
  相似文献   

12.
Europium(III)-doped carbon dots (Eu-CDs) were prepared from citric acid and europium nitrate via a one-pot pyrolytic method. The Eu-CDs emit intense blue fluorescence (with excitation/emission peaks at 365/465 nm), are water soluble and biocompatible. On addition of 2,6-dipicolinic acid (DPA; an anthrax biomarker), ligand-to-ion energy transfer occurs from DPA to Eu(III) which has a red emission peaking at 615 nm. This results in an increase of the intensity of the red fluorescence. DPA can be detected by the ratio of fluorescence intensities at 616 and 475 nm. The method has an analytical range that extends from 5 to 700 nmol·L?1, with a 5 nmol·L?1 detection limit. The Eu-CDs also were incorporated into a test paper for visual detection of DPA with a portable UV lamp and a smartphone. In this case, the detection limit is 1 μmol·L?1. The Eu-CDs internalize well into HeLa cells, and this paves the way to bioimaging.
Graphical abstract Schematic of a method for visual detection of 2,6-dipicolinic acid (DPA, an anthrax biomarker) by using a test stripe impregnated with europium(III)-doped carbon dots (Eu-CDs).
  相似文献   

13.
This article reports on a novel aptamer-based platform for the quantitation of urea by using an aptamer with high affinity and selectivity for urea. The surface of a glassy carbon electrode (GCE) was modified by drop casting a cocktail consisting of carbon nanotubes and reduced graphene oxide (rGO) decorated with platinum-gold nanoparticles. The urea aptamer was then immobilized on the nanocomposite via covalent conjugation. Cyclic voltammetry and electrochemical impedance spectroscopy were employed to trace the modification of the GCE. Binding of urea caused the aptamer to be folded, and this result in an inhibition of the interfacial charge transfer rate when using hexacyanoferrate as an electrochemical redox probe. The change in redox current was quantified by differential pulse voltammetry, typically at a working voltage of 0.22 V vs. Ag/AgCl. The assay has a 1.9 pM detection limit, and the response is linear up to 150 nM concentration of urea. The superior selectivity and affinity of aptamer-modified GCE makes it a most useful tool for analysis of urea present in very low concentrations.
Graphical abstract Schematic representation of different steps of aptasensor fabrication.
  相似文献   

14.
A nanocomposite consisting of polyaniline and multiwalled carbon nanotubes was tethered with a thiolated thrombin-specific aptamer and placed on a glassy carbon electrode (GCE) to obtain a biosensor for thrombin that has a limit of detection of 80 fM. Tethering was accomplished via a thiol-ene reaction between thiolated thrombin aptamer (TTA) and oxidized polyaniline (PANI) that was chemically synthesized in the presence of solution-dispersed multiwalled carbon nanotubes (MWCNTs). The modified GCE exhibits a pair of well-defined redox peaks (at 50/?25 mV) of self-doped PANI in neutral solution, and the tethered TTA-thrombin interaction gives a decreased electrochemical signal. Cyclic voltammetry, scanning electron microscopy and ultraviolet visible spectroscopy were used to characterize the film properties. This amperometric aptasensor is sensitive, selective and reproducible. It was applied to the determination of thrombin in spiked human serum (0.2 to 4 nM) and gave recoveries that ranged from 95 to 102%.
Graphical abstract A nanocomposite consisting of polyaniline (PANI) and multiwalled carbon nanotubes (MWCNTs) was tethered with a thiolated thrombin aptamer (TTA) and placed on a glassy carbon electrode (GCE) to obtain a biosensor for thrombin that has a 80 f. detection limit.
  相似文献   

15.
A nanocomposite consisting of cadmium oxide decorated with carbon nanotubes (CdO.CNT NC) was prepared by a wet-chemical technique, and its optical, morphological, and structural properties were characterized by FTIR, UV/Vis, FESEM coupled to XEDS, XPS, and XRD methods. A flat glassy carbon electrode was modified with the nanocomposite to obtain a sensor for L-glutathione (GSH) which displays improved sensitivity, a large dynamic range and good long-term stability. The calibration plot (best acquired at a voltage of 0.5 V) is linear (r 2 = 0.99) in the 0.1 nM to 0.01 M GSH concentration range. The detection limit is as low as 30.0 pM, and the sensitivity is ~9.49 μA?μM?1?cm?2. To the best of our knowledge, this is the first report on the determination of GSH using such a modified glassy carbon electrode (GCE) in combination with I-V method. The GCE was applied to the selective determination of GSH in spiked rabbit serum samples and gave acceptable results.
Graphical abstract A selective glutathione biosensor based on wet-chemically prepared CdO.CNT/Nafion/GCE was fabricated by reliable I-V method and shows good analytical parameters such as high sensitivity, low detection limit, long-term stability, and large dynamic range.
  相似文献   

16.
A highly selective electrochemical sensor was fabricated based on a modified carbon paste electrode with zinc ferrite nanoparticles (ZnFe2O4 NPs). The nanocomposite has attractive properties such as high surface-to-volume ratio and good electrocatalytic activity towards the drugs acetaminophen (AC), epinephrine (EP), and melatonin (MT), best at working voltages of 0.35, 0.09 and 0.55 V (vs. Ag/AgCl), respectively. The linear ranges (and detection limits) are 6.5–135 (0.4) μmol L?1 for AC, 5–100 (0.7) μmol L?1 for EP, and 6.5–145 (3) μmol L?1 for MT.
Graphical abstract A novel electrochemical sensor based on a modified carbon paste electrode with zinc ferrite nanoparticles (ZnFe2O4) for the simultaneous detection of the acetaminophen, epinephrine and melatonin was fabricated
  相似文献   

17.
Polyimide (PI) sheets were laser etched to obtain graphene-based carbon nanomaterials (LEGCNs). These were analyzed by scanning electron microscopy, X-ray diffraction and Raman spectroscopy which confirmed the presence of stacked multilayer graphene nanosheets. Their large specific surface and large number of edge-plane active sites facilitate the accumulation of metal ions. A glassy carbon electrode (GCE) with an in-situ plated bismuth film was modified with the LEGCNs to give a sensor with satisfactory response for the simultaneous determination of cadmium(II) and lead(II) by means of square wave anodic stripping voltammetry. It appears that is the first report on an electrochemical sensor based on the use of laser etched graphene for determination of heavy metal ions. Figures of merit for detection of Cd(II) include (a) a low and well separated working potential of ?0.80 V (vs. Ag/AgCl), (b) a wide linear range (from 7 to 120 μg·L?1), and a low detection limits 0.47 μg·L?1. The respective data for Pb(II) are (a) -0.55 V, (b) 5 to 120 μg·L?1, and (c) 0.41 μg·L?1. The modified GCE displays remarkable repeatability, reproducibility, selectivity and stability. The sensor was applied to the simultaneous determination of Cd(II) and Pb(II) in spiked real water samples. The results confirm that the laser etching technique is an efficient tool for the preparation of carbon nanomaterials with high quality and great sensing performance.
Graphical abstract Bismuth film and laser etched graphene-modified glassy carbon electrode (BF-LEGCN/GCE) for the simultaneous determination of cadmium(II) and lead(II) by square wave anodic stripping voltammetry.
  相似文献   

18.
Core-shell Au@Ag nanorods (Ag@GNRs) were synthesized and utilized to construct a voltammetric biosensor for trichloroacetic acid (TCA). The biosensor was prepared by immobilizing hemoglobin (Hb) on a glassy carbon electrode (GCE) that was modified with the Ag@GNRs. Cyclic voltammetry revealed a pair of symmetric redox peaks, indicating that direct electron transfer occurs at the Hb on the Ag@GNR-film. The electron transfer rate constant is as high as 2.32 s?1. The good electrocatalytic capability and large surface area of the Ag@GNR-film is beneficial in terms of electron transfer between Hb and the underlying electrode. The modified GCE, best operated at ?0.4 V (vs. SCE), exhibits electrocatalytic activity toward TCA in the 0.16 μM to 1.7 μM concentration range, with a 0.12 μM detection limit (at an S/N ratio of 3).
Graphical abstract Core-shell Au@Ag nanorods (Ag@GNRs) were synthesized and used to immobilize hemoglobin to construct an effective biosensor for trichloroacetic acid.
  相似文献   

19.
A glassy carbon electrode (GCE) was modified with a nanocomposite consisting of tetraoctylammonium bromide (TOAB), C60 fullerene, and palladium nanorods (PdNRs). The PdNRs were hydrothermally prepared and had a typical width of 20 ± 2 nm. The nanocomposite forms stable films on the GCE and exhibits a reversible redox pair for the C60/C60 ? system while rendering the surface to be positively charged. The modified GCE was applied to fabricate an electrochemical biosensor for detecting acetylcholinesterase (AChE) by measurement of the amount of thiocholine formed from acetylthiocholine, best at a working voltage of ?0.19 V (vs. SCE). The detection scheme is based on (a) measurement of the activity of ethyl paraoxon-inhibited AChE, and (b) measurement of AChE activity after reactivation with pralidoxime (2-PAM). Compared to the conventional methods using acetylthiocholine as a substrate, the dual method presented here provides data on the AChE activity after inhibition and subsequent reactivation, thereby yielding credible data on reactivated enzyme activity. The linear analytical range for AChE activity extends from 2.5 U L?1 to 250 kU·L?1, and the detection limit is 0.83 U L?1.
Graphical abstract Cyclovoltammetric acetylcholinesterase (AChE) activity assay is constructed based on the palladium nanorods composited with functionalized C60 fullerene (PdNR/C60 + TOAB), which aims to measure the signal change between ethyl paraoxon-inhibited and subsequent pralidoxime (2-PAM)-reactivated AChE activity.
  相似文献   

20.
Carbon quantum dots doped with nitrogen and phosphorus were prepared from adenosine 5′-monophosphate (AMP) in a single simple synthesis step. The nitrogen and phosphorus doped C-dots (N,P-C-dots) were characterized by transmission electron microscopy, Fourier transform infrared spectroscopy, fluorescence spectroscopy, X-ray photoelectron spectroscopy and X-ray powder diffraction. These carbon dots display blue fluorescence, with excitation/emission maxima at 360/430 nm, a quantum yield of 26.5% and an average decay time of 4.3 ns. Fluorescence is strongest at neutral pH values but quenched at very high and very low pH values. It is also quenched by ferric ions which suggests the use of the N,P-C-dots as fluorescent probes for Fe(III). A hemolysis test inferred favorable blood compatibility. The fluorescence of the doped C-dots is excitation wavelength dependent and also is susceptible to 2-photon excitation. The nanoparticles were applied in the fluorescent multicolor bioimaging of A549 (adenocarcinomic alveolar basal epithelial) cells under different excitation wavelengths, typically at 405, 488 and 543 nm. Emission colors ranging from blue to green and red can be adjusted in this way.
Graphical abstract Nitrogen and phosphorus doped carbon dots were synthesized and showed excitation wavelength-dependent behavior. They were applied to multi-color fluorescence imaging of adenocarcinomic alveolar basal epithelial cells.
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号