1.
Recently, in vivo feasibility of tissue harmonic imaging with a mechanically rotated intravascular ultrasound (IVUS) catheter was experimentally demonstrated. To isolate the second harmonic signal content, a combination of pulse inversion and analog filtering was used. In this paper the development of a simulation tool to investigate nonlinear IVUS beams is reported, and the influence of transducer rotation and axial catheter-to-tissue motion on the efficiency of PI signal processing is evaluated. Nonlinear beams were simulated in homogeneous tissue-mimicking media at a transmit frequency of 20 MHz, which resulted in second harmonic pressure fields at 40 MHz. The competing effects of averaging and decorrelation between neighboring rf lines on the signal-to-noise ratio (SNR) were studied for a single point scatterer. An optimal SNR was achieved when lines were combined over 3 degrees - 3.75 degrees. When the transducer was rotated with respect to point scatterers, simulating the acoustic response of tissue, the fundamental frequency suppression using PI degraded rapidly with increasing interpulse angles. The effect of axial catheter-to-tissue motion on the efficiency of pulse inversion seemed to be of less influence for realistic motion values. The results of this study will aid in the optimization of harmonic IVUS imaging systems.  相似文献   

2.
Recently, the in vivo feasibility of tissue harmonic imaging (THI) with a mechanically-rotated intravascular ultrasound (IVUS) catheter was experimentally demonstrated. To isolate the second harmonic signal content, both pulse inversion (PI) and analog filtering were used. In the present paper, we report the development of a simulation tool to investigate nonlinear IVUS beams and the influence of rotation on the efficiency of PI signal processing. Nonlinear 20 MHz beams were simulated in a homogeneous tissue-mimicking medium, resulting in second harmonic pressure fields at 40 MHz. The acoustic response from tissue was simulated by summing radio-frequency (RF) pulse-echo responses from many point-scatterers. When the transducer was rotated with respect to the point-scatterers, the fundamental frequency suppression using PI degraded rapidly with increasing inter-pulse angles. The results of this study will aid in the optimization of harmonic IVUS imaging systems.  相似文献   

3.
Behar V  Adam D 《Ultrasonics》2004,42(10):1101-1109
A linear array imaging system with coded excitation is considered, where the proposed excitation/compression scheme maximizes the signal-to-noise ratio (SNR) and minimizes sidelobes at the output of the compression filter. A pulse with linear frequency modulation (LFM) is used for coded excitation. The excitation/compression scheme is based on the fast digital mismatched filtering. The parameter optimization of the excitation/compression scheme includes (i) choice of an optimal filtering function for the mismatched filtering; (ii) choice of an optimal window function for tapering of the chirp amplitude; (iii) optimization of a chirp-to-transducer bandwidth ratio; (iv) choice of an appropriate n-bit quantizer. The simulation results show that the excitation/compression scheme can be implemented as a Dolph–Chebyshev filter including amplitude tapering of the chirp with a Lanczos window. An example of such an optimized system is given where the chirp bandwidth is chosen to be 2.5 times the transducer bandwidth and equals 6 MHz: The sidelobes are suppressed to −80 dB, for a central frequency of 4 MHz, and to −94 dB, for a central frequency of 8 MHz. The corresponding improvement of the SNR is 18 and 21 dB, respectively, when compared to a conventional short pulse imaging system. Simulation of B-mode images demonstrates the advantage of coded excitation systems of detecting regions with low contrast.  相似文献   

4.
In this study, the phenomenon of higher harmonic thickness resonance of a piezoelectric transducer was used to investigate potentially additional sensitivity at the third harmonic frequency for conventional medical transducers. The motivation for this research is that some applications in medical ultrasound (e.g. third harmonic transmit phasing and contrast imaging) need probes which are sensitive around both the fundamental and third harmonic frequencies, and that these higher harmonic thickness modes, although often considered as undesired, might be used beneficially. The novelty aspect in this study is the presented transmit and receive potential at both the fundamental and third harmonic of a conventional cardiac probe with modified electrical tuning. Elements of an experimental PZT-based phased-array probe (fc = 3 MHz, 64 elements, element width = 0.3 mm, elevation aperture = 13 mm) were electrically retuned with series inductors around the third harmonic resonance frequency at 10 MHz. Hydrophone measurements with 10-MHz-tuned elements showed that, as compared to a conventionally tuned element, the transmit transfer function at the third harmonic increased more than 23 dB, while the sensitivity at the fundamental frequency was only 6 dB lower. Pulse-echo measurements showed that the two-way transfer function of a 10-MHz-tuned element resulted in 20 dB increased sensitivity around the third harmonic as compared to an untuned element. Simulated transfer functions, from both a 1D KLM and 2D finite element model of an element of the experimental array transducer, confirmed the measured sensitivity peaks at the fundamental and third harmonic. In conclusion, this study demonstrated the effect of changing the electrical tuning on a conventional array transducer which increased the sensitivity around the third harmonic resonance frequency, while maintaining good sensitivity at the fundamental frequency.  相似文献   

5.

Objective and motivation

The goal of this work was to test experimentally that exposing air bubbles or ultrasound contrast agents in water to amplitude modulated wave allows control of inertial cavitation affected volume and hence could limit the undesirable bioeffects.

Methods

Focused transducer operating at the center frequency of 10 MHz and having about 65% fractional bandwidth was excited by 3 μs 8.5 and 11.5 MHz tone-bursts to produce 3 MHz envelope signal. The 3 MHz frequency was selected because it corresponds to the resonance frequency of the microbubbles used in the experiment. Another 5 MHz transducer was used as a receiver to produce B-mode image. Peak negative acoustic pressure was adjusted in the range from 0.5 to 3.5 MPa. The spectrum amplitudes obtained from the imaging of SonoVueTM contrast agent when using the envelope and a separate 3 MHz transducer were compared to determine their cross-section at the - 6 dB level.

Results

The conventional 3 MHz tone-burst excitation resulted in the region of interest (ROI) cross-section of 2.47 mm while amplitude modulated, dual-frequency excitation with difference frequency of 3 MHz produced cross-section equal to 1.2 mm.

Conclusion

These results corroborate our hypothesis that, in addition to the considerably higher penetration depth of dual-frequency excitation due to the lower attenuation at 3 MHz than that at 8.5 and 11.5 MHz, the sample volume of dual-frequency excitation is also smaller than that of linear 3-MHz method for more spatially confined destruction of microbubbles.  相似文献   

6.
Current medical diagnostic echo systems are mostly using harmonic imaging. This means that a fundamental frequency (e.g., 2 MHz) is transmitted and the reflected and scattered higher harmonics (e.g., 4 and 6 MHz), produced by nonlinear propagation, are recorded. The signal level of these harmonics is usually low and a well-defined transfer function of the receiving transducer is required. Studying the acoustic response of a single contrast bubble, which has an amplitude in the order of a few Pascal, is another area where an optimal receive transfer function is important.

We have developed three methods to determine the absolute transfer function of a transducer. The first is based on a well-defined wave generated by a calibrated source in the far field. The receiving transducer receives the calibrated wave and from this the transfer functions can be calculated. The second and third methods are based on the reciprocity of the transducer. The second utilizes a calibrated hydrophone to measure the transmitted field. In the third method, a pulse is transmitted by the transducer, which impinges on a reflector and is received again by the same transducer. In both methods, the response combined with the transducer impedance and beam profiles enables the calculation of the transfer function.

The proposed methods are useful to select the optimal piezoelectric material (PZT, single crystal) for transducers used in reception only, such as in certain 3D scanning designs and superharmonic imaging, and for selected experiments like single bubble behavior.

We tested and compared these methods on two unfocused single element transducers, one commercially available (radius 6.35 mm, centre frequency 2.25 MHz) the other custom built (radius 0.75 mm, centre frequency 4.3 MHz). The methods were accurate to within 15%.  相似文献   


7.
Shen CC  Shi TY 《Ultrasonics》2011,51(5):554-560

Background

Ultrasound tissue harmonic signal generally provides superior image quality as compared to the linear signal. However, since the generation of the tissue harmonic signal is based on finite amplitude distortion of the propagating waveform, the penetration and the sensitivity in tissue harmonic imaging are markedly limited because of the low signal-to-noise ratio (SNR).

Methods

The method of third harmonic (3f0) transmit phasing can improve the tissue harmonic SNR by transmitting at both the fundamental (2.25 MHz) and the 3f0 (6.75 MHz) frequencies to achieve mutual enhancement between the frequency-sum and the frequency-difference components of the second harmonic signal. To further increase the SNR without excessive transmit pressure, coded excitation can be incorporated in 3f0 transmit phasing to boost the tissue harmonic generation.

Results

Our analyses indicate that the phase-encoded Golay excitation is suitable in 3f0 transmit phasing due to its superior transmit bandwidth efficiency. The resultant frequency-sum and frequency-difference components of tissue harmonic signal can be simultaneously Golay-encoded for SNR improvement. The increase of the main-lobe signal with the Golay excitation in 3f0 transmit phasing are consistent between the tissue harmonic measurements and the simulations. B-mode images of the speckle generating phantom also demonstrate the increases of tissue harmonic SNR for about 11 dB without noticeable compression artifacts.

Conclusion

For tissue harmonic imaging in combination with the 3f0 transmit phasing method, the Golay excitation can provide further SNR improvement. Meanwhile, the axial resolution can be effectively restored by pulse compression while the lateral resolution remains unchanged.  相似文献   

8.
The feasibility of ultrahigh-resolution coherence spectroscopy with a train of picosecond light pulses from a synchronously pumped mode-locked and cavity-dumped dye laser is demonstrated. Narrow resonances of periodic pulse excitation are observed whenever the pulse repetition rate of the laser of a higher harmonic coincides with the frequency splitting of coherently excited levels. The zero-field hyperfine splitting of the Na-ground state (1771.6 MHz) could be measured in the 2100th order of the excitation rate with a resonance halfwidth of 800 Hz.  相似文献   

9.
An acoustic microscopy system was designed to perform 2D imaging in the C-plane with a single-element transducer. The ultrasound transducer was fabricated by polishing bulk lithium niobate (LiNbO(3)) to the required thickness (approximately 60 or 45 micro) for the desired operating frequency (55 or 75 MHz). The polished LiNbO(3) was attached to acoustic backing and matching layers. Finally, an epoxy lens was applied and the transducer mounted in a housing. The transducer was mounted in a 3D motorized positioning stage and operated by a high-frequency pulser/receiver. Received echoes were sampled with a 2 GHz ADC card and displayed on a PC using software developed in the Matlab environment. Transducer frequency and bandwidth were measured off a steel plate positioned at the focal length. A penny was scanned initially to confirm expected performance before acquiring data from liver (n=3) and spleen (n=3) specimens. For the first probe, the peak frequency was 54.05 MHz with a -6 dB bandwidth of 6.76 MHz. The axial and lateral resolutions were estimated to be 114 and 188 microm, respectively. For the second probe, the peak frequency was measured to 82 MHz with a -6 dB bandwidth of approximately 23 MHz. The axial and lateral resolutions were estimated to be around 33 and 81 microm, respectively. C-scans of the penny clearly showed detailed structures on front and back, while the capsule and the trabecular structures of the splenic tissues could easily be separated in different layers. In conclusion, an acoustic microscopy system operating at 55-75 MHz has been constructed and the feasibility of obtaining high-resolution images of tissue specimens demonstrated.  相似文献   

10.
Nonlinear contrast imaging modes such as second harmonic imaging (HI) and subharmonic imaging (SHI) are increasingly important for clinical applications. However, the performance of currently available transducers for HI and SHI is significantly constrained by their limited bandwidth. To bypass this constraint, a novel transducer concept termed multi-frequency harmonic transducer arrays (MFHA's) has been designed and a preliminary evaluation has been conducted. The MFHA may ultimately be used for broadband contrast enhanced HI and SHI with high dynamic range and consists of three multi-element piezo-composite sub-arrays (A-C) constructed so the center frequencies are 4f(A) = 2f(B) = f(C) (specifically 2.5/5.0/10.0 MHz and 1.75/3.5/7.0 MHz). In principle this enables SHI by transmitting on sub-array C receiving on B and, similarly, from B to A as well as HI by transmitting on A receiving on B and, likewise, from B to C. Initially transmit and receive pressure levels of the arrays were measured with the elements of each sub-array wired in parallel. Following contrast administration, preliminary in vitro HI and SHI signal-to-noise ratios of up to 40 dB were obtained. In conclusion, initial design and in vitro characterization of two MFHA's have been performed. They have an overall broad frequency bandwidth of at least two octaves. Due to the special design of the array assembly, the SNR for HI and SHI was comparable to that of regular B-mode and better than commercially available HI systems. However, further research on multi-element MFHA's is required before their potential for in vivo nonlinear contrast imaging can be assessed.  相似文献   

11.
The application of ultrasound contrast agents aims to detect low velocity blood flow in the microcirculation. To enhance discrimination between tissue and blood containing the contrast agent, harmonic imaging is used. Harmonic imaging requires the application of narrow-band signals and is obscured by high levels of native harmonics generated in an intervening medium. To improve discrimination between contrast agent and native harmonics, a pulse inversion technique has been proposed. Pulse inversion allows wide-band signals, thus preserving the axial resolution. The present study examines the interference of native harmonics and discusses the practical difficulties of wide-band pulse inversion measurements of harmonics by a single transducer. Native harmonics are not eliminated by pulse inversion. Furthermore, only even harmonics remain and are amplified by 6 dB, alleviating the requirement for selective filtering. Finally, it is shown that the contaminating third harmonic contained in the square wave activation signal leaks through in the emitted signal. The spectral location of the contaminating third harmonic is governed by the transducer spectral characteristics while the location of the native and contrast agent second harmonics is not. Thus the contaminating third harmonic and the native and contrast agent second harmonics may overlap and interfere. Optimal discrimination requires a balance between maximal sensitivity for the second harmonic at reception and minimal interference from the contaminating third harmonic.  相似文献   

12.
The second harmonic and subharmonic components, the frequencies of which are twice and one half the fundamental frequency, are included in echoes from contrast agents. An imaging method, which employs a second harmonic (second harmonic imaging), is widely used in medical diagnoses. On the other hand, subharmonic is expected to provide a higher contrast between biological tissues and blood flow because echo signals are generated only from blood containing the contrast agents. However, the subharmonic component echo signal power from contrast agents is relatively low. This has resulted in little progress in the field of subharmonic imaging. In this study, a new imaging method is proposed using amplitude-modulated waves as transmitted waves combined with the pulse inversion method to enhance subharmonic echo signals. Two optimal frequencies are set, including the modulated waves, F(1) and F(2), so that the subharmonic frequency of F(1) and the second harmonic frequency of F(2) may result in the same value. This allows a more powerful signal at the frequency band because the second harmonic and subharmonic components are integrated. Furthermore, a B-mode ultrasound image of an agar phantom that imitated biological tissue and showed the effectiveness of our method was reconstructed. As a result, the echo power of the subharmonic component was enhanced by approximately 11.8 dB more than the conventional method and the signal to noise ratio showed an improvement of 7.6 dB.  相似文献   

13.
Jeong JS  Chang JH  Shung KK 《Ultrasonics》2012,52(6):730-739
In an ultrasound image-guided High Intensity Focused Ultrasound (HIFU) surgery, reflected HIFU waves received by an imaging transducer should be suppressed for real-time simultaneous imaging and therapy. In this paper, we investigate the feasibility of pulse compression scheme combined with notch filtering in order to minimize these HIFU interference signals. A chirp signal modulated by the Dolph-Chebyshev window with 3-9 MHz frequency sweep range is used for B-mode imaging and 4 MHz continuous wave is used for HIFU. The second order infinite impulse response notch filters are employed to suppress reflected HIFU waves whose center frequencies are 4 MHz and 8 MHz. The prototype integrated HIFU/imaging transducer that composed of three rectangular elements with a spherically con-focused aperture was fabricated. The center element has the ability to transmit and receive 6 MHz imaging signals and two outer elements are only used for transmitting 4 MHz continuous HIFU wave. When the chirp signal and 4 MHz HIFU wave are simultaneously transmitted to the target, the reflected chirp signals mixed with 4 MHz and 8 MHz HIFU waves are detected by the imaging transducer. After the application of notch filtering with pulse compression process, HIFU interference waves in this mixed signal are significantly reduced while maintaining original imaging signal. In the single scanline test using a strong reflector, the amplitude of the reflected HIFU wave is reduced to −45 dB. In vitro test, with a sliced porcine muscle shows that the speckle pattern of the restored B-mode image is close to that of the original image. These preliminary results demonstrate the potential for the pulse compression scheme with notch filtering to achieve real-time ultrasound image-guided HIFU surgery.  相似文献   

14.
Vibro-acoustography is an imaging method based on audio-frequency harmonic vibrations induced in the object by the radiation force of focused ultrasound. The purpose of this study is to investigate features of vibro-acoustography images and manifestation of various tissue structures and calcifications in such images. Our motivation for this study is to pave the way for further in vitro and in vivo applications of vibro-acoustography. Here, vibro-acoustography images of excised prostate and in vivo breast are presented and compared with images obtained with other modalities. Resulting vibro-acoustography images obtained with a 3 MHz ultrasound transducer and at a vibration frequency of 50-60 kHz show soft tissue structures, tissue borders, and microcalcifications with high contrast, high resolution, and no speckle. It is concluded that vibro-acoustography offers features that may be valuable for diagnostic purposes.  相似文献   

15.
Chirp-encoded excitation has been utilized for increased signal-to-noise ratio (SNR) in both linear and harmonic imaging. In either case, it is necessary to isolate the relevant frequency band to avoid artifacts. In contrast, the present study isolates and then combines the fundamental and the higher harmonics, treating them as a single, extended bandwidth. Pulse-inverted sum and difference signals are first used to isolate even and odd harmonics. Matched filters specific to the source geometry and the transmit signal are then separately applied to each harmonic band. Verification experiments are performed using up to the third harmonic resulting from an underwater chirp excitation. Analysis of signal peaks after scattering from a series of steel and nylon wires indicates increased compression using the extended bandwidth, as compared to well-established methods for fundamental and second harmonic chirp compression. Using third harmonic bands, a mean pulse width of 56% relative to fundamental compression and 48% relative to second harmonic compression was observed. Further optimization of the compression by altering the transmission indicated 17% additional reduction in the pulse width and a 47% increase in peak-to-sidelobe ratio. Overall, results establish the feasibility of extended bandwidth signal compression for simultaneously increasing SNR and signal resolution.  相似文献   

16.
脉冲超声激励下SonoVue微泡的瞬态空化特性   总被引:1,自引:0,他引:1       下载免费PDF全文
林玉童  秦鹏 《声学学报》2018,43(2):202-208
将SonoVue微泡从临床疾病诊断拓展至治疗引起了诸多研究人员的兴趣。为了平衡治疗效率和生物安全性,深入理解声学参数和SonoVue微泡瞬态空化的关系至关重要。本研究自行制备仿体容器放置SonoVue微泡,使用1 MHz发射换能器激励其产生空化效应,另一个7.5 MHz的聚焦换能器接收声信号,经放大及高速数据采集后送上位机处理。通过深入分析信号的时频域特征,我们提出以宽带信号的能量及其随时间变化曲线的半高宽来表征瞬态空化的剂量(ICD)和相对持续时间(ICP),并确定:瞬态空化的发生和ICD依赖于峰值负声压,但ICP随峰值负声压的增加而减小;脉冲重复频率和脉冲持续时间都和ICD及ICP正相关;且脉冲持续时间的影响较大。这些结果有望为SonoVue微泡的治疗应用提供理论支持。   相似文献   

17.
张志甜  张超  王文炎  马廷锋  刘岩  冯冠平 《中国物理 B》2010,19(9):97701-097701
This paper investigates the properties of thickness extension mode excited by lateral electric field on LiNbO3 by using the extended Christoffel-Bechmann method. It finds that the lateral field excitation coupling factor for amode (quasi-extensional mode) reaches its maximum value of 28% on X-cut LiNbO3. The characteristics of a lateral field excitation device made of X-cut LiNbO3 have been investigated and the lateral field excitation device is used for the design of a high frequency ultrasonic transducer. The time and frequency domain pulse/echo response of the LiNbO3 lateral field excitation ultrasonic transducer is analysed with the modified Krimholtz-Leedom-Matthae model and tested using traditional pulse/echo method. A LiNbO3 lateral field excitation ultrasonic transducer with the centre frequency of 33.44 MHz and the -6 dB bandwidth of 33.8% is acquired, which is in good agreement with the results of the Krimholtz-Leedom-Matthae model. Further analysis suggests that the LiNbO3 lateral field excitation device has great potential in the design of broadband high frequency ultrasonic transducers.  相似文献   

18.
《Ultrasonics》1986,24(3):117-132
This paper describes the design, construction and performance of a set of immersion probes which provided useful frequency coverage in the range 3–170 MHz by simple methods, that is harmonic excitation of commercially available lead zirconate titanate and quartz piezoelectric elements. A comparison of the two transducer materials and a comprehensive study of their output power as a function of frequency are presented.  相似文献   

19.
《Ultrasonics》2005,43(2):79-85
Nonlinear contrast imaging modes such as second harmonic imaging (HI) and subharmonic imaging (SHI) are increasingly important for clinical applications. However, the performance of currently available transducers for HI and SHI is significantly constrained by their limited bandwidth. To bypass this constraint, a novel transducer concept termed multi-frequency harmonic transducer arrays (MFHA's) has been designed and a preliminary evaluation has been conducted. The MFHA may ultimately be used for broadband contrast enhanced HI and SHI with high dynamic range and consists of three multi-element piezo-composite sub-arrays (A–C) constructed so the center frequencies are 4fA=2fB=fC (specifically 2.5/5.0/10.0 MHz and 1.75/3.5/7.0 MHz). In principle this enables SHI by transmitting on sub-array C receiving on B and, similarly, from B to A as well as HI by transmitting on A receiving on B and, likewise, from B to C. Initially transmit and receive pressure levels of the arrays were measured with the elements of each sub-array wired in parallel. Following contrast administration, preliminary in vitro HI and SHI signal-to-noise ratios of up to 40 dB were obtained. In conclusion, initial design and in vitro characterization of two MFHA's have been performed. They have an overall broad frequency bandwidth of at least two octaves. Due to the special design of the array assembly, the SNR for HI and SHI was comparable to that of regular B-mode and better than commercially available HI systems. However, further research on multi-element MFHA's is required before their potential for in vivo nonlinear contrast imaging can be assessed.  相似文献   

20.
Elasticity imaging is an emerging medical imaging modality. Methods involving acoustic radiation force excitation and pulse-echo ultrasound motion detection have been investigated to assess the mechanical response of tissue. In this work new methods for dynamic radiation force excitation and motion detection are presented. The theory and model for harmonic motion detection of a vibrating reflective target are presented. The model incorporates processing of radio frequency data acquired using pulse-echo ultrasound to measure harmonic motion with amplitudes ranging from 100 to 10,000 nm. A numerical study was performed to assess the effects of different parameters on the accuracy and precision of displacement amplitude and phase estimation and showed how estimation errors could be minimized. Harmonic pulsed excitation is introduced as a multifrequency radiation force excitation method that utilizes ultrasound tonebursts repeated at a rate f(r). The radiation force, consisting of frequency components at multiples of f(r), is generated using 3.0 MHz ultrasound, and motion detection is performed simultaneously with 9.0 MHz pulse-echo ultrasound. A parameterized experimental analysis showed that displacement can be measured with small errors for motion with amplitudes as low as 100 nm. The parameterized numerical and experimental analyses provide insight into how to optimize acquisition parameters to minimize measurement errors.  相似文献   